Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical clocks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

High-Power Clock Laser Spectrally Tailored for High-Fidelity Quantum State Engineering

Highly frequency-stable lasers are ubiquitous tools for optical-frequency metrology, precision interferometry, and quantum information science. While making a universally applicable laser is unrealistic, spectral noise can be tailored for specific applications. Here we report a high-power 698-nm clock laser with a maximum output of 4W and minimized frequency noise up to a few kHz Fourier frequency, together with long-term instability of 3.5 × 10 −17 at one to thousands of seconds. The laser-frequency noise is precisely characterized with atom-based spectral analysis that employs a pulse sequence designed to suppress sensitivity to intensity noise. This method provides universally applicable tunability of the spectral response and analysis of quantum sensors over a wide frequency range. With the optimized laser system characterized by this technique, we achieve an average single-qubit Clifford gate fidelity of up to 𝐹$^2_1$ = 0.999⁢64⁢(3) when simultaneously driving 3000 optical qubits with a homogeneous Rabi frequency ranging from 10 Hz to 1 kHz. This result represents the highest single optical-qubit-gate fidelity for a large number of atoms.

atomic gases↗

Cold Atom Source Containing Multiple Magneto-Optical Traps

An apparatus that serves as a source of a cold beam of atoms contains multiple two-dimensional (2D) magneto-optical traps (MOTs). (Cold beams of atoms are used in atomic clocks and in diverse scientific experiments and applications.) The multiple-2D-MOT design of this cold atom source stands in contrast to single-2D-MOT designs of prior cold atom sources of the same type. The advantages afforded by the present design are that this apparatus is smaller than prior designs.

Ramirez-Serrano, Jaime↗

Four-shooter - A large format charge-coupled device camera for the Hale telescope

The Hale telescope has employed an astronomical camera using four 800x800 CCDs in an optical arrangement that allows the imaging of a contiguous 1600-pixel-square region of the sky; reimaging optics are then used to yield a scale of 0.33 arcsec/pixel. Optical coatings are incorporated to yield a throughput at peak efficiency of nearly 50 percent, including telescope losses. This camera can be used in a scanning mode, in which the telescope tracking rate is offset and the charge is clocked in the chips in such a way that the charge image remains aligned with the optical image. Attention is given to the results of a survey for high-redshift quasars using this equipment, which has produced images for the most distant galaxy clusters yet discovered.

Gunn, James E.↗

Ion-Atom Cold Collisions and Atomic Clocks

Collisions between ultracold neutral atoms have for some time been the subject of investigation, initially with hydrogen and more recently with laser cooled alkali atoms. Advances in laser cooling and trapping of neutral atoms in a Magneto-Optic Trap (MOT) have made cold atoms available as the starting point for many laser cooled atomic physics investigations. The most spectacularly successful of these, the observation of Bose-Einstein Condensation (BEC) in a dilute ultra-cold spin polarized atomic vapor, has accelerated the study of cold collisions. Experimental and theoretical studies of BEC and the long range interaction between cold alkali atoms is at the boundary of atomic and low temperature physics. Such studies have been difficult and would not have been possible without the development and advancement of laser cooling and trapping of neutral atoms. By contrast, ion-atom interactions at low temperature, also very difficult to study prior to modern day laser cooling, have remained largely unexplored. But now, many laboratories worldwide have almost routine access to cold neutral atoms. The combined technologies of ion trapping, together with laser cooling of neutrals has made these studies experimentally feasible and several very important, novel applications might come out of such investigations . This paper is an investigation of ion-atom interactions in the cold and ultra-cold temperature regime. Some of the collisional ion-atom interactions present at room temperature are very much reduced in the low temperature regime. Reaction rates for charge transfer between unlike atoms, A + B(+) approaches A(+) + B, are expected to fall rapidly with temperature, approximately as T(sup 5/2). Thus, cold mixtures of atoms and ions are expected to coexist for very long times, unlike room temperature mixtures of the same ion-atom combination. Thus, it seems feasible to cool ions via collisions with laser cooled atoms. Many of the conventional collisional interactions, exploited as a useful tool at room temperature and higher, are greatly enhanced at low energy. For example, collisional spin transfer from one species of polarized atoms to another has long been a useful method for polarizing a sample of atoms where no other means was available. Because optical pumping cannot be used to polarize the nuclear spin of Xe-129 or He-3 (for use in nmr imaging of the lungs), the nuclear spins are polarized via collisions with an optically pumped Rb vapor in a cell containing both gases. In another case, a spin polarized thermal Cs beam was used to polarize the hyperfine states of trapped He(+)-3 ions in order to measure their hyperfine clock transition frequency. The absence of an x-ray light source to optically pump the ground state of the He(+)-3 ion necessitated this alternative state preparation. Similarly, Cd(+) and Sr(+) ions were spin-oriented via collisions in a cell with optically pumped Rb vapor. Resonant RF spin changing transitions in the ground state of the ions were detected by changes in the Rb resonance light absorption. Because cold collision spin exchange rates scale with temperature as T(sup -1/2) this technique is expected to be a far more powerful tool than the room temperature counterpart. This factor of 100 or more enhancement in spin exchange reaction rates at low temperatures is the basis for a novel trapped ion clock where laser cooled neutrals will cool, state select and monitor the ion clock transition. The advantage over conventional direct laser cooling of trapped ions is that the very expensive and cumbersome UV laser light sources, required to excite the ionic cooling transition, are effectively replaced by simple diode lasers.

Prestage, John D.↗

Free Space Ramsey Spectroscopy in Rubidium with Noise below the Quantum Projection Limit

In this work, we demonstrate the utility of optical cavity generated spin-squeezed states in free space atomic fountain clocks in ensembles of 390 000 87 Rb atoms. Fluorescence imaging, correlated to an initial quantum nondemolition measurement, is used for population spectroscopy after the atoms are released from a confining lattice. For a free fall time of 4 milliseconds, we resolve a single-shot phase sensitivity of 814(61) microradians, which is 5.8(0.6) decibels (dB) below the quantum projection limit. We observe that this squeezing is preserved as the cloud expands to a roughly 200 μ m radius and falls roughly 300 μm in free space. Ramsey spectroscopy with 240 000 atoms at a 3.6 ms Ramsey time results in a single-shot fractional frequency stability of 8.4(0.2) × 10 –12 , 3.8(0.2) dB below the quantum projection limit. The sensitivity and stability are limited by the technical noise in the fluorescence detection protocol and the microwave system, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dr. Sahar Said Allam (1964-2022): A Memoriam

In this short talk, we memorialize the scientific life of AAS member Dr. Sahar Said Allam (1964-2022), an alumna of Cairo University and the National Research Institute of Astronomy \& Geophysics (NRIAG). Her scientific career took her to the Universitaet Potsdam (Germany), New Mexico State University (USA), the Space Telescope Science Institute (USA), and the Fermi National Accelerator Laboratory (Fermilab; USA), as well as to astronomical observatories in New Mexico, Arizona, Hawaii, Chile, and Australia. Among other projects, she worked on the Sloan Digital Sky Survey (SDSS) and the Dark Energy Survey (DES), achieving the coveted “Builders” status on both these projects. She was the discoverer of the (at the time) brightest known Lyman Break Galaxy, the strongly lensed “8 O’Clock Arc”, and played an important role in the discovery of the optical counterpart to the gravitational wave event GW170817. During her final illness, she began work as a Data Preview 0 (“DP0”) De legate for the Vera C. Rubin Legacy Survey of Space & Time (LSST) and was even the Principal Investigator on a successful observing proposal submitted posthumously. The asteroid “135979 Allam” is named after her.

Tucker, Douglas L.↗

QPPM receiver for free-space laser communications

A prototype receiver developed at NASA Lewis Research Center for direct detection and demodulation of quaternary pulse position modulated (QPPM) optical carriers is described. The receiver enables dual-channel communications at 325-Megabits per second (Mbps) per channel. The optical components of the prototype receiver are briefly described. The electronic components, comprising the analog signal conditioning, slot clock recovery, matched filter and maximum likelihood data recovery circuits are described in more detail. A novel digital symbol clock recovery technique is presented as an alternative to conventional analog methods. Simulated link degradations including noise and pointing-error induced amplitude variations are applied. The bit-error-rate performance of the electronic portion of the prototype receiver under varying optical signal-to-noise power ratios is found to be within 1.5-dB of theory. Implementation of the receiver as a hybrid of analog and digital application specific integrated circuits is planned.

Budinger, J. M.↗

Verification and Calibration of Spectroscopy and Polarization modes for the Roman Coronagraph Instrument

As part of its technology demonstration, the Nancy Grace Roman Space Telescope Coronagraph Instrument (CGI) will demonstrate point source spectroscopy and polarization measurements of disks. The spectroscopy mode is a zero-deviation Amici prism and slit to a confirmed planet after an imaging detection. The Wollaston prism polarization optics allow for imaging two orthogonal polarization states simultaneously. The CGI spectral characterization modes, designed and built at Goddard Space Flight Center (GSFC), have a spectral resolution of R50 in two 15% bandpass centered at 660nm and 730nm intended to capture key methane absorption features. There are duplicate Wollaston prism channels, clocked 45 degrees with respect to one another covering 10% bandpasses at 575 and 825nm, but the optics meet performance requirements across the full CGI bandpass. The Wollaston design and optical elements are a contribution by the Japanese Aerospace Exploration Agency, with final alignment and testing being done at GSFC. We highlight the requirements for these modes, the ground-to-orbit calibration process, and the operations required to use a deployable slit on a CGI point source in the presence of pointing error. We also provide further detail on the optomechanical design, testing results from the final as-built flight units, verification process, and performance of the as-built flight assemblies.

Tyler D. Groff↗

Dynamic Self-Locking of an OEO Containing a VCSEL

A method of dynamic self-locking has been demonstrated to be effective as a means of stabilizing the wavelength of light emitted by a vertical-cavity surface-emitting laser (VCSEL) that is an active element in the frequency-control loop of an optoelectronic oscillator (OEO) designed to implement an atomic clock based on an electromagnetically- induced-transparency (EIT) resonance. This scheme can be considered an alternative to the one described in Optical Injection Locking of a VCSEL in an OEO (NPO-43454), NASA Tech Briefs, Vol. 33, No. 7 (July 2009), page 33. Both schemes are expected to enable the development of small, low-power, high-stability atomic clocks that would be suitable for use in applications involving precise navigation and/or communication. To recapitulate from the cited prior article: In one essential aspect of operation of an OEO of the type described above, a microwave modulation signal is coupled into the VCSEL. Heretofore, it has been well known that the wavelength of light emitted by a VCSEL depends on its temperature and drive current, necessitating thorough stabilization of these operational parameters. Recently, it was discovered that the wavelength also depends on the microwave power coupled into the VCSEL. This concludes the background information. From the perspective that led to the conception of the optical injection-locking scheme described in the cited prior article, the variation of the VCSEL wavelength with the microwave power circulating in the frequency-control loop is regarded as a disadvantage and optical injection locking is a solution of the problem of stabilizing the wavelength in the presence of uncontrolled fluctuations in the microwave power. The present scheme for dynamic self-locking emerges from a different perspective, in which the dependence of VCSEL wavelength on microwave power is regarded as an advantageous phenomenon that can be exploited as a means of controlling the wavelength. The figure schematically depicts an atomic-clock OEO of the type in question, wherein (1) the light from the VCSEL is used to excite an EIT resonance in selected atoms in a gas cell (e.g., 87Rb atoms in a low-pressure mixture of Ar and Ne) and (2) the power supplied to the VCSEL is modulated by a microwave signal that includes components at beat frequencies among the VCSEL wavelength and modulation sidebands. As the VCSEL wavelength changes, it moves closer to or farther from a nearby absorption spectral line, and the optical power transmitted through the cell (and thus the loop gain) changes accordingly. A change in the loop gain causes a change in the microwave power and, thus, in the VCSEL wavelength. It is possible to choose a set of design and operational parameters (most importantly, the electronic part of the loop gain) such that the OEO stabilizes itself in the sense that an increase in circulating microwave power causes the VCSEL wavelength to change in a direction that results in an increase in optical absorption and thus a decrease in circulating microwave power. Typically, such an appropriate choice of operational parameters involves setting the nominal VCSEL wavelength to a point on the shorter-wavelength wing of an absorption spectral line.

Strekalov, Dmitry↗

SIREN: Scaling Ion-Traps by REquiring iNnovative Heterogenous Integration

The SIREN (Scaling Ion Traps by Requiring iNnovative heterogenous integration) project explores the feasibility of heterogeneous integration (HI) as a transformative approach to scaling ion traps, a critical technology for advancing quantum computers and atomic clocks. Traditional ion trap architectures face significant challenges in scalability due to limitations in optical access, fabrication techniques, and material constraints. SIREN addresses these challenges by leveraging HI, which combines different materials and fabrication processes to create more complex and efficient ion trap structures. HI integrated structures can be manufactured without compromising the process to maintain compatibility to ion traps. This project focuses on integrating a separately fabricated waveguide with a fully functional ion trap. The respective alignment between the pieces needs to be accurate to less than 2 µm to ensure that the light from the waveguide can overlap with the trapping region. The fine alignment must also be maintained through an ultra-high vacuum bake, a critical step in preparing an ion trap experiment. The project's outcomes suggest that heterogeneous integration is a promising pathway for overcoming current scalability barriers, paving the way for the next generation of quantum technologies. SIREN's findings contribute significantly to the field, offering a scalable solution that could accelerate the development of practical quantum computers and highly accurate atomic clocks.

42 ENGINEERING↗

Generalised hyper-Ramsey spectroscopy of two-level atoms in an optically dense medium

The peculiarities of Ramsey resonance and its sensitivity to the light shift from an optically dense medium of cold atoms are investigated. Different composite pulse protocols for clock spectroscopy, including hyper-Ramsey, modified and generalised hyper-Ramsey schemes, are compared. Error signals change significantly due to the processes of absorption and dispersion in the atomic medium. The dependence of the position of the central fringe resonance with a residual uncompensated light shift of the atomic transition is studied with the attenuation of the radiation intensity in the medium taken into account. It is shown that using a combination of generalised hyper-Ramsey error signals allows one to suppress the sensitivity to the light shift for any length of the medium. (laser cooling of atoms)

74 ATOMIC AND MOLECULAR PHYSICS↗

(abstract) Precision Time and Frequency Transfer Utilizing SONET OC-3

An innovative method of distributing precise time and reference frequency to users located several kilometers from a frequency standard and master clock has been developed by the Timing Solutions Corporation of Boulder, CO. The Optical Two-Way Time Transfer System (OTWTTS) utilizes a commercial SONET OC-3 facility interface to physically connect a master unit to multiple slave units at remote locations. Optical fiber is a viable alternative to standard copper cable and microwave transmission. This paper discusses measurements of frequency and timing stability over the OTWTTS.

optical fiber precision time standards frequency r↗

Holographic optical interconnects for VLSI

This paper introduces new applications and design trade-offs anticipated for free-space optical interconnections of VLSI chips. New implementation s of VLSI functions are described that use the capability of making optical inputs at any point on a chip and take advantage of greater flexibility in on-chip signal routing. These include n-port addressable memories, CPU clock phase distribution, hardware multipliers, and dynamic memory refresh, as well as enhanced testability. Fault tolerance and production yields may be improved by reprogramming the optical imaging system to circumvent defective elements. These attributes, as well as those related to performance alone, will affect the design methodology of future VLSI ICs. This paper focuses on identifying the design issues, their possible solutions, and their impact on VLSI design techniques and, finally, presents some preliminary measurements on various system components.

Bergman, L. A.↗

Measuring the Cryogenic Optical Alignment Between the Telescope Element and the Instruments Module of the James Webb Space Telescope

The alignment between the Aft Optical Subsystem (AOS) and the Integrated Science Instruments Module (ISIM) is non-adjustable in orbit, so the alignment must be carefully verified in a cryogenic vacuum environment prior to launch. Optical point source locations calibrated by optical metrology instruments are imaged through the AOS onto the Science Instruments to determine focal, lateral, and clock angle alignment. The pupil image of the AOS is overlaid onto the pupil image of the NIRCam to determine the tip and tilt alignment. In addition, an image from fiducial lights at the Primary Mirror checks the pupil alignment between the telescope entrance pupil, the telescope pupil mask, and the NIRCam aperture stop. The image positions are combined to determine the relative alignment between the Optical Telescope Element (OTE) and the ISIM in all six degrees of freedom with corresponding alignment uncertainties. Uncertainties in the position of focused images of the test sources and images from the pupils are derived from sensitivities of an optical model of the system and the Science Instrument sensing capability. Additional uncertainty in the pupil alignment measurement is due to uncertainty in the analytical removal of gravity effects that simulate the on-orbit alignment environment.

Whitman, Tony↗

Generation of Optical Combs in a WGM Resonator from a Bichromatic Pump

Optical combs generated by a monolithic resonator with Kerrmedium can be used in a number of applications, including orbital clocks and frequency standards of extremely high accuracy, such as astronomy, molecular spectroscopy, and the like. The main difficulty of this approach is the relatively high pump power that has to be used in such devices, causing undesired thermorefractive effects, as well as stimulated Raman scattering, and limiting the optical comb quality and utility. In order to overcome this problem, this innovation uses a different approach to excitation of the nonlinear oscillations in a Kerr-nonlinear whispering gallery mode (WGM) resonator and generation of the optical comb. By coupling to the resonator two optical pump frequencies instead of just one, the efficiency of the comb source can be increased considerably. It therefore can operate in a lowerpower regime where the undesirable effects are not present. This process does not have a power threshold; therefore, the new optical component can easily be made strong enough to generate further components, making the optical comb spread in a cascade fashion. Additionally, the comb spacing can be made in an arbitrary number of the resonator free spectral ranges (FSR). The experimental setup for this innovation used a fluorite resonator with OMEGA= 13.56 GHz. This material has very low dispersion at the wavelength of 1.5 microns, so the resonator spectrum around this wavelength is highly equidistant. Light was coupled in and out of the resonator using two optical fibers polished at the optimal coupling angle. The gap between the resonator and the fibers, affecting the light coupling and the resonator loading, was controlled by piezo positioners. The light from the input fiber that did not go into the resonator reflected off of its rim, and was collected by a photodetector. This enabled observation and measurement of the (absorption) spectrum of the resonator. The input fiber combined light from two lasers centered at around 1,560 nanometers. Both laser frequencies were simultaneously scanned around the selected WGMs of the same family. However, they were separated by one, two, three, or ten FSRs. This was achieved by fine-tuning each laser frequency offset until the selected resonances overlap on the oscilloscope screen. The resonator quality factor Q = 7 x 10(exp 7) was relatively low to increase the linewidth and, therefore, the duty cycle of both lasers simultaneously coupled into their WGMs. The optical spectrum analyzer (OSA) connected to the output fiber was continuously acquiring data, asynchronously with the laser scan. The instrument was set to retain the peak power values; therefore, a trace recorded for a sufficiently long period of time reflected the situation with both lasers maximally coupled to the WGMs.

Strekalov, Dmitry V.↗

Simulating Future GPS Clock Scenarios with Two Composite Clock Algorithms

Using the GPS Toolkit, the GPS constellation is simulated using 31 satellites (SV) and a ground network of 17 monitor stations (MS). At every 15-minutes measurement epoch, the monitor stations measure the time signals of all satellites above a parameterized elevation angle. Once a day, the satellite clock estimates the station and satellite clocks. The first composite clock (B) is based on the Brown algorithm, and is now used by GPS. The second one (G) is based on the Greenhall algorithm. The composite clock of G and B performance are investigated using three ground-clock models. Model C simulates the current GPS configuration, in which all stations are equipped with cesium clocks, except for masers at USNO and Alternate Master Clock (AMC) sites. Model M is an improved situation in which every station is equipped with active hydrogen masers. Finally, Models F and O are future scenarios in which the USNO and AMC stations are equipped with fountain clocks instead of masers. Model F is a rubidium fountain, while Model O is more precise but futuristic Optical Fountain. Each model is evaluated using three performance metrics. The timing-related user range error having all satellites available is the first performance index (PI1). The second performance index (PI2) relates to the stability of the broadcast GPS system time itself. The third performance index (PI3) evaluates the stability of the time scales computed by the two composite clocks. A distinction is made between the "Signal-in-Space" accuracy and that available through a GNSS receiver.

global positioning system↗

WFIRST CGI: Prism and Polarizer Characterization Modes

As part of its technology demonstration, the WFIRST coronagraph instrument (CGI) will demonstrate point source spectroscopy and polarization measurements of disks. The specific implementation of spectroscopy is a zero-deviation Amici prism and slit to be placed on the planet after high contrast has been achieved by CGI. The polarization optics are a set of Wollaston prisms so that orthogonal polarization states can be measured simultaneously. The CGI spectral characterization mode, being designed and built and Goddard Space Flight Center (GSFC), has a spectral resolution of R50 and is designed to accommodate a 15% bandpass spanning 610-785nm. In order to recover Stokes information, there are two sets of Wollaston prisms clocked 45 degrees with respect to one another with each measurement taken in series. The Wollaston design and optical elements are a contribution by the Japanese Aerospace Exploration Agency, with final alignment and testing being done at GSFC. The spectroscopy mode is designed to target Methane absorption features around 730nm, keeping the spectral resolution as low as possible to improve the signal-to-noise ratio and hence reduce detection time. We highlight the requirements for these modes and address the challenge of on-orbit spectral calibration for a deployable slit in the presence of pointing drifts. Of unique interest is how the observatory error budget couples into good stellar spectrum calibration and subsequent speckle subtraction. We also provide further detail on the optomechanical design, its stability based on thermal and structural predictions, modeled performance, and operations concept. These performance metrics are simulated to demonstrate how a slit located at an arbitrary field point is homed onto the planet and converted to a calibrated spectrum.

Tyler D Groff↗

Implementation of quantum key distribution and quantum clock synchronization via time bin encoding

Quantum key distribution allows for a provably secure transmission of cryptographic keys over an optical channel. Encoded polarization states or time-bin degree of freedom have been used for successful demonstrations. However, photon losses in long fibers, slow single photon detectors, and detector dark counts significantly limit the overall bit rate. Improving key throughput and reducing the overhead of key reconciliation remain as major challenges. Methods which utilize multiple time bins allow for multiple key bits to be encoded in a single photon, thus increasing the fidelity of transmitted keys and decreasing the overhead of key reconciliation in real-world conditions. Previous implementations of these methods required that Alice and Bob share a time reference by sharing a dedicated classical channel used for synchronization. This work presents a technique that allows two parties to exchange time-bin encoded photons without the need for synchronized time references. Our technique uses a framing protocol which allows Alice to encode a time reference along with a key which is determined by Alice before transmission. Security can be achieved by monitoring the visibility of a pair of Franson interferometers, using decoy pulses and measuring the round trip time between Alice and Bob. The bit rate of this technique is limited only by the recovery time of the detector and the speed of the modulation electronics. We experimentally demonstrate a raw bit rate of 5Mb/s over an optical channel with 55dB of loss, which is competitive with current research. We also demonstrate absolute timing synchronization with an accuracy of 20ps.

encryption↗