Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Viricidal and bactericidal exciplex barrier-discharge lamps

A brief review is presented of investigations performed in 2002 – 2020 on ultraviolet inactivation of bacteria, vital cells, and viruses by using excilamps. The excilamp models that have been developed at the Institute of High-Current Electronics, SB RAS are briefly described. Scientific data acquired by now show that excilamps on KrCl{sup *}, KrBr{sup *}, and XeBr{sup *} molecules are an alternative to low-pressure mercury lamps with respect to optical parameters. These sources of optical radiation exhibit a bactericidal effect, and emission of KrCl and KrBr excilamps demonstrates viricidal action. The latter is actual due to expansion of coronavirus disease. (paper)

60 APPLIED LIFE SCIENCES↗

Source of the optical red-slope in iron-rich meteorites

The relationship between ordinary chondrites and S-type asteroids is an unresolved issue in meteorite science. S-type asteroids exhibit a positively red-sloped spectrum that is interpreted to indicate the presence of elemental iron on the surfaces. The characteristic red-sloped spectrum of iron-rich meteorites is produced by only the specular component of the reflectance. Complex metallic surfaces can be modeled as linear mixtures of specular and nonspecular components. It is the geometry of the metal on a surface and its interaction with surrounding material, rather than the absolute amount of metal, that determine the redness of resulting spectra. In order to distinguish between ordinary chondrite and differentiated parent bodies it is important to understand how regolith processes affect the nature and form of metal on asteroid surfaces.

Britt, Daniel T.↗

Phase-Length Optical Phase-Locked-Loop Sensor (PLOPS)

PLOPS system designed to provide high-resolution measurement of change in optical length from optical-system source to any optical reflector, including diffuse reflector. Serves as adjustable optical ruler, providing high resolution in measurements of small and large changes in distance to target. Use is broad and includes most measurement situations requiring information on length, vibration, and their derivatives. Applications include building dynamics, remote sensing of vibrations in such systems as turbine-based machinery, monitoring of structural dynamics, noncontacting sensing of surface contours, measurement of large strains as in earthquake monitoring, measurement of atmospheric dynamics and turbulence, high-resolution sensing of humidity, detection of surface acoustic waves by optical microscopy, and related areas.

Heyman, Joseph S.↗

Self-irradiated cooling condensations - The source of the optical line emission from cooling flows

The optical filaments seen at the centers of clusters of galaxies, which cannot be explained by standard photoionization or shock models, can be straightforwardly interpreted as self-irradiated cooling condensations. Fully developed (about 10,000 K) condensations embedded in thermally unstable 10 million K gas will be bathed in a powerful EUV/soft X-ray flux emanating from the surrounding condensing regions. The present models of the condensation/irradiation process give line ratios and luminosities similar to those observed. Because it is assumed that the condensations arise from linear perturbations, which grow significantly only when the local cooling time is less than the free-fall time, condensing regions of the type modeled here should arise only in cooling flows of central pressure less than about 1 billion ergs/cu cm and should extend only over the inner regions of the cluster.

Voit, G. Mark↗

Accurate radio and optical positions for southern radio sources

Accurate radio positions with a precision of about 0.01 arcsec are reported for eight compact extragalactic radio sources south of -45-deg declination. The radio positions were determined using VLBI at 8.4 GHz on the 9589 km Tidbinbilla (Australia) to Hartebeesthoek (South Africa) baseline. The sources were selected from the Parkes Catalogue to be strong, flat-spectrum radio sources with bright optical QSO counterparts. Optical positions of the QSOs were also measured from the ESO B Sky Survey plates with respect to stars from the Perth 70 Catalogue, to an accuracy of about 0.19 arcsec rms. These radio and optical positions are as precise as any presently available in the far southern sky. A comparison of the radio and optical positions confirms the estimated optical position errors and shows that there is overall agreement at the 0.1-arcsec level between the radio and Perth 70 optical reference frames in the far south.

Harvey, Bruce R.↗

On three-dimensional reconstruction of optically thin solar emission sources

Calculations are given for constructing the three dimensional distribution of optically thin EUV emission sources associated with solar active regions, from two dimensional observations (projections) recorded by the spectroheliograph on the OSO 7 satellite. The relation of the method to other image reconstruction methods is briefly discussed as well as the special requirements imposed in the solar case such as a knowledge of the true solar rotation function. A useful correlation criterion for establishing the physical validity of solutions is given.

Kastner, S. O.↗

Optical linear algebra processors - Noise and error-source modeling

The modeling of system and component noise and error sources in optical linear algebra processors (OLAPs) are considered, with attention to the frequency-multiplexed OLAP. General expressions are obtained for the output produced as a function of various component errors and noise. A digital simulator for this model is discussed.

Casasent, D.↗

Procedures for dealing with certain types of noise and systematic errors common to many Hadamard transform optical systems

Sources of noise and error correcting procedures characteristic of Hadamard transform optical systems were investigated. Reduction of spectral noise due to noise spikes in the data, the effect of random errors, the relative performance of Fourier and Hadamard transform spectrometers operated under identical detector-noise-limited conditions, and systematic means for dealing with mask defects are among the topics discussed. The distortion in Hadamard transform optical instruments caused by moving Masks, incorrect mask alignment, missing measurements, and diffraction is analyzed and techniques for reducing or eliminating this distortion are described.

Harwit, M.↗

High-temperature optically activated GaAs power switching for aircraft digital electronic control

Gallium arsenide high-temperature devices were fabricated and assembled into an optically activated pulse-width-modulated power control for a torque motor typical of the kinds used in jet engine actuators. A bipolar heterojunction phototransistor with gallium aluminum arsenide emitter/window, a gallium arsenide junction field-effect power transistor and a gallium arsenide transient protection diode were designed and fabricated. A high-temperature fiber optic/phototransistor coupling scheme was implemented. The devices assembled into the demonstrator were successfully tested at 250 C, proving the feasibility of actuator-located switching of control power using optical signals transmitted by fibers. Assessments of the efficiency and technical merits were made for extension of this high-temperature technology to local conversion of optical power to electrical power and its control at levels useful for driving actuators. Optical power sources included in the comparisons were an infrared light-emitting diode, an injection laser diode, tungsten-halogen lamps and arc lamps. Optical-to-electrical power conversion was limited to photovoltaics located at the actuator. Impedance matching of the photovoltaic array to the load was considered over the full temperature range, -55 C to 260 C. Loss of photovoltaic efficiency at higher temperatures was taken into account. Serious losses in efficiency are: (1) in the optical source and the cooling which they may require in the assumed 125 C ambient, (2) in the decreased conversion efficiency of the gallium arsenide photovoltaic at 260 C, and (3) in impedance matching. Practical systems require improvements in these areas.

Berak, J. M.↗

Planets as background noise sources in free space optical communications

Background noise generated by planets is the dominant noise source in most deep space direct detection optical communications systems. Earlier approximate analyses of this problem are based on simplified blackbody calculations and can yield results that may be inaccurate by up to an order of magnitude. Various other factors that need to be taken into consideration, such as the phase angle and the actual spectral dependence of the planet albedo, in order to obtain a more accurate estimate of the noise magnitude are examined.

Katz, J.↗

Study of optical properties of X-ray sources

A series of optical and X-ray observations of Sco X-1 and Cyg X-2 by UHURU satellite is reported. Results for Sco X-1 show a definite correlation between optical and X-ray intensity and thus indicate a common emitting region with the source being quiet and having no short term fluctuations bigger than 10%. Spectra reveal the presence of a high excitation complex at wavelength 4650 due to N III-C III. Spectra of a faint 15-mag red object NW of the radio position indicate that Cyg X-1 is associated with a bright B supergiant star. The flux from the edges of the Cygnus Loop in the coronal line at wavelength 5303 was measured to be less than five times ten to the minus nine power erg/sq cm/sterad/sec (0.017 R) in a 3-A band centered on the line. This indicates substantial broadening of the line profile by mass motion or that the temperature is somewhat higher than the present estimate from X-ray data.

Vandenbout, P. A.↗

Radio optical reference frame. 6: Additional source positions in the northern hemisphere

Radio and optical positions for northern hemisphere extragalactic sources are reported. Milliarcsecond (mas) accurate radio positions of 106 sources north of -2 deg declination are derived from Mark III Very Long Baseline Interferometry (VLBI) observations taken during ten experiments from 1990 January through 1990 October. The results presented supplement an ongoing project to define and maintain an all-sky radio/optical reference frame of 400 or more extragalactic sources with mas accurate radio and optical positions. Radio positions for 34 new sources are presented along with improved radio positions for 72 sources already in the reference frame catalog. An additional nine sources have been determined to be unsuitable reference frame objects. Radio observations of nine calibration sources tie the new positions to the existing catalogue. The radio positions of the new sources have formal mean errors of approximately 0.7 mas in right ascension and approximately 1.0 mas in declination. Sources for which we report improved radio positions now have formal mean errors of approximately 0.5 mas in both coordinates, an improvement in some cases by as much as 75%. Positions in the FK5 system have also been obtained for the optical counterparts of an additional five northern hemisphere radio sources using prime focus plates from the Kitt Peak National Observatory's 4 m telescope and a Ritchey-Chretien focus plate from the Calar Alto 2.2 m telescope. The optical positions have internal accuracies of about 0.03 sec and differ from the radio positions by about 0.07 sec on the average.

Fey, A. L.↗

Concentrator optical characterization using computer mathematical modelling and point source testing

The optical characteristics of a paraboloidal solar concentrator are analyzed using the intercept factor curve (a format for image data) to describe the results of a mathematical model and to represent reduced data from experimental testing. This procedure makes it possible not only to test an assembled concentrator, but also to evaluate single optical panels or to conduct non-solar tests of an assembled concentrator. The use of three-dimensional ray tracing computer programs to calculate the mathematical model is described. These ray tracing programs can include any type of optical configuration from simple paraboloids to array of spherical facets and can be adapted to microcomputers or larger computers, which can graphically display real-time comparison of calculated and measured data.

Dennison, E. W.↗

Measuring the Cryogenic Optical Alignment Between the Telescope Element and the Instruments Module of the James Webb Space Telescope

The alignment between the Aft Optical Subsystem (AOS) and the Integrated Science Instruments Module (ISIM) is non-adjustable in orbit, so the alignment must be carefully verified in a cryogenic vacuum environment prior to launch. Optical point source locations calibrated by optical metrology instruments are imaged through the AOS onto the Science Instruments to determine focal, lateral, and clock angle alignment. The pupil image of the AOS is overlaid onto the pupil image of the NIRCam to determine the tip and tilt alignment. In addition, an image from fiducial lights at the Primary Mirror checks the pupil alignment between the telescope entrance pupil, the telescope pupil mask, and the NIRCam aperture stop. The image positions are combined to determine the relative alignment between the Optical Telescope Element (OTE) and the ISIM in all six degrees of freedom with corresponding alignment uncertainties. Uncertainties in the position of focused images of the test sources and images from the pupils are derived from sensitivities of an optical model of the system and the Science Instrument sensing capability. Additional uncertainty in the pupil alignment measurement is due to uncertainty in the analytical removal of gravity effects that simulate the on-orbit alignment environment.

Whitman, Tony↗

Optical polarization of a complete sample of radio sources

The radio and optical properties of a complete 5 GHz sample of strong radio sources are studied. High polarization is strongly correlated with the fraction of the total 5 GHz flux density found in a milliarcsec core. The detection rate of radio galaxies containing optical cores with high polarization is consistent with the hypothesis that all radio sources contain optically polarized cores, with strength proportional to the core radio flux density. High optical polarization, optical power-law fraction, line-to-continuum ratio, emission lines of small equivalent widths, and large amplitude flux variability are all strongly correlated with the fraction of the 5 GHz radio flux density that is unresolved on VLBI scales. The distributions of these properties are well matched by a model where radio and optical radiation have the same beaming geometry and with Doppler boosting of a factor of 10-100 in the optical. A striking alignment of the position angle of the VLBI structure axis and the position angle of optical polarization in highly polarized sources is confirmed.

Impey, C. D.↗

Changes in SSL Device Efficiency and Optical Performance Under Accelerated Aging Conditions

Lighting application efficiency (LAE) describes the efficient delivery of light from the light source to the lighted task and is viewed as a new frontier—increasing energy savings with solid-state lighting (SSL) technologies. The framework for LAE that is proposed by the U.S. Department of Energy (DOE) consists of four major elements: light source efficiency, optical delivery efficiency, spectral efficiency, and intensity effectiveness. This report focuses on a sampling of the available SSL products that can be broadly defined as having modified spectral output because the method of spectra modification has a significant impact on light source efficiency and long-term optical delivery and spectral efficiencies. This report focused on the changes in light source, optical delivery, and spectral efficiencies that occur during aging of SSL devices. An accelerated stress test (AST) regiment was developed for the devices under test (DUTs) examined in this report to provide insights into how the performance of SSL devices change with aging. The AST protocols demonstrate that the SSL products discussed in this report often reduce light source efficiency to achieve different spectral characteristics. In addition, aging of the optical components (e.g., lenses, solder masks) in SSL devices can produce increased light absorption, which negatively impacts optical delivery efficiency and light source efficiency. The modified spectral outputs of the selected SSL products discussed in this report come in a variety of form factors and achieve enhanced optical performance by using a variety of methods. All of the products examined in this study use mid-power light-emitting diodes (MP-LEDs), although the number, configuration, phosphor content, and light-emitting diode (LED) pump of the MP-LEDs differ. Product MS-1 is a 60-watt (W) replacement A19 lamp with a hermetically sealed glass globe, which contains an embedded optical filter to absorb green and yellow emissions, thereby creating a “sunlike” modified spectrum. Product MS-2 is a 60-W replacement A19 lamp with 30 MP-LEDs, and it uses a violet LED pump, along with green and red phosphor emissions, to produce a “healthy” spectrum. This spectrum omits blue emissions in an effort to reduce melanopic lux. Product MS-3 is an LED module consisting of 21 MP-LEDs that use a violet LED pump, along with blue, green, and red phosphors, to produce a “sunlike” spectrum. Products MS-4 and MS-5 are both 6-inch (in) downlights that use a manual switching mechanism so that users can select application-specific correlated color temperatures before installation. Products MS-4 and MS-5 both contain two LED primaries (2,700 Kelvin [K] and 5,000 K) for spectral tuning. Product MS-4 contains 12 MP-LEDs for each LED primary, and Product MS-5 contains 10 MP-LEDs for each LED primary. This report summarizes the overall findings from up to 8,000 hours (hrs) of AST on the lamp DUTs (Products MS-1 and MS-2); up to 5,000 hrs of AST on the LED light engine DUTs (Product MS-3); and up to 7,000 hrs of AST on the downlight DUTs (Products MS-4 and MS-5). The AST procedures used in this study included a room temperature operational life (RTOL) test, an operational life test conducted at 45 degrees Celsius (°C; 45OL) test, an operational life test conducted at 75°C (75OL), a wet high-temperature operational life test performed at 65°C and 90% relative humidity (6590), and a wet high-temperature operational life test performed at 75°C and 75% relative humidity (7575). The AST procedures used for Products MS-1 and MS-2 were RTOL, 45OL, and 6590. The AST procedures used for Products MS-3, MS-4, and MS-5 were RTOL, 75OL, and 7575. During the ASTs described herein, separate populations of each product (three DUTs in each population for Products MS-1, MS-2, MS-4, and MS-5; four DUTs in each population for Product MS-3) were subjected to power cycling of 1 hr on and 1 hr off. The key findings from this study include the following. Enhanced optical performance came at the cost of reduced light source efficiency for the lamps and light engines examined in this study. The optical filter used to produce a “sunlike” spectrum for Product MS-1 reduced light source efficiency by 26%, from 113 lumens per watt (lm/W) to 85 lm/W. Products MS-2 and MS-3 that used a violet-pumped LED to achieve “healthy” and “sunlike” enhanced optical performance, respectively, suffered the largest reduction in initial light source efficiency (49 lm/W for Product MS-2 and 68 lm/W for Products MS-3) perhaps because of the use of violet LED as the optical pump. Product MS-2 also had the poorest color fidelity because of undersaturation of blues and oversaturation of greens and yellows. Chromaticity maintenance of the products in this study was generally good, with parametric failure only occurring for one product at one AST condition (i.e., Product MS-3 at 7575). The chromaticity shift for Product MS-3 in 7575 test conditions resulted from reduced emissions of the broad green and red phosphors used to mimic sunlight in the 500–750 nanometer (nm) range. As a result of these phosphor emission losses, chromaticity shifted toward the more stable violet-pumped LED and blue phosphor. Although chromaticity maintenance was acceptable for most products tested, different chromaticity shift mechanisms were observed for temperature and humidity tests compared with temperature alone for Products MS-1, MS-2, and MS-3. For Product MS-1, a relative increase in green emissions was observed with humidity, which may indicate humidity-accelerated degradation of the optical filter at green wavelengths (optical delivery efficiency reduction) or degradation of the emitters in the red region (spectral efficiency reduction). The violet-pumped products (i.e., MS-2 and MS-3) exhibited different chromaticity shift behavior in the temperature-humidity environments, with Product MS-2 shifting generally yellow because of photo-induced oxidation of the plastic globe (i.e., a reduction of optical delivery efficiency) and Product MS-3 shifting toward violet and blue emitters because of faster loss of emission from green and red phosphors (i.e., a reduction in spectral efficiency). Because of an initial drop in power consumption, the light source efficiency of downlights (Products MS-4 and MS-5) increased at RTOL throughout the test duration. The light source efficiency initially increased during 75OL until a decay in luminous flux maintenance (LFM) dominated light source efficiency, whereas the light source efficiency decreased for the entire 7575 test duration. It was found that increasing the ambient environment of an SSL device from 25°C to 75°C decreases the LFM by 2.7 to 5.5, depending on design of the SSL device. Adding humidity to the system (75OL to 7575) was found to decrease LFM by another factor of approximately 3.0. A common location of failure was identified for the downlights (Products MS-4 and MS-5) operated in the 7575 environment. This failure abruptly occurred between 3,000 to 5,000 hrs of testing on the film capacitor of the electromagnetic interference (EMI) filter near the diode bridge for 11 of the 12 downlights. It is likely that this failure was caused by a combination of the high electrical voltage across the capacitor, the location of the capacitor near the heat sources (e.g., transformers, diode bridges, power resistors), and the high stress environment of 7575. Longer test times are needed to fully understand the LFM, luminous efficacy changes, and chromaticity shifts for some of the products. Because of the high reliability, light source efficiency, and spectral tuning capabilities of LEDs, the expectations of LAE for SSL products are greatly increased over traditional lighting products. The data gathered in this report begin to provide an understanding of the tradeoffs that current SSL products undergo when optimizing the different efficiency elements of LAE. As discussed in this report, the findings from the tests conducted show that the optimization of spectral efficiency can come at the cost of initial light source efficiency. Furthermore, the introduction of violet LEDs can promote long-term optical delivery efficiency degradation, and the introduction of optical filters or new phosphors can lead to unwanted spectral efficiency changes because the ratio of phosphor emitters changes with aging. The data presented in this report also identified a common failure location in 6-in downlights. The results regarding long-term behavior of the modified spectra devices studied provide valuable information about changes to the light source, spectral, and optical delivery efficiencies as the devices age. This information can be used to improve future SSL designs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

First Search for an X-Ray-Optical Reverberation Signal in an Ultraluminous X-Ray Source

Using simultaneous optical (VLT/FORS2) and X-ray (XMM-Newton) data of NGC 5408, we present the first ever attempt to search for a reverberation signal in an ultraluminous X-ray source (NGC 5408 X-1). The idea is similar to active galactic nucleus broad line reverberation mapping where a lag measurement between the X-ray and the optical flux combined with a Keplerian velocity estimate should enable us to weigh the central compact object. We find that although NGC 5408 X-1ʼs X-rays are variable on a timescale of a few hundred seconds (rms of 9.0 +/- 0.5%), the optical emission does not show any statistically significant variations. We set a 3σ upper limit on the rms optical variability of 3.3%. The ratio of the X-ray to the optical variability is an indicator of X-ray reprocessing efficiency. In X-ray binaries, this ratio is roughly 5. Assuming a similar ratio for NGC 5408 X-1, the expected rms optical variability is approximately equal to 2%, which is still a factor of roughly two lower than what was possible with the VLT observations in this study. We find marginal evidence (3 sigma) for optical variability on an approximately 24 hr timescale. Our results demonstrate that such measurements can be made, but photometric conditions, low sky background levels, and longer simultaneous observations will be required to reach optical variability levels similar to those of X-ray binaries.

: accretion↗