Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Acousto-optic tunable filter imaging spectrometers

A remote sensing multispectral imaging instrument is being developed that uses a high resolution, fast programmable acoustooptic tunable filter (AOTF) as the spectral bandpass filter. A compact and fully computer controllable AOTF-based imaging spectrometer that operates in the visible wavelength range (0.5-0.8 microns) has been built and tested with success. A second imaging spectrometer operating in the near-infrared wavelength range (1.2-2.4 microns) is also under experimental investigation. The design criteria meeting various system issues, such as imaging quality, spectral response, and field of view (FOV), are discussed. An experiment using this AOTF imaging spectrometer breadboard is described.

Chao, Tien-Hsin↗

Dual purpose optical instrument capable of simultaneously acting as spectrometer and diffractometer

A dual purpose optical instrument is described capable of simultaneously acting as a spectrometer and diffractometer to respectively perform elemental and structural analysis of an unknown sample. The diffractometer portion of the instrument employs a modified form of Seeman-Bohlin focusing which involves providing a line source of X-rays, a sample, and a detector, all on the same focal circle. The spectrometer portion of the instrument employs a fixedly mounted X-ray energy detector mounted outside of the plane of the focal circle.

Dasgupta, K.↗

Characterizing the performance of a POPS miniaturized optical particle counter when operated on a quadcopter drone

We first validate the performance of the Portable Optical Particle Spectrometer (POPS), a small light-weight and high sensitivity optical particle counter, against a reference scanning mobility particle sizer (SMPS) for a month-long deployment in an environment dominated by biomass burning aerosols. Subsequently, we examine any biases introduced by operating the POPS on a quadcopter drone, a DJI Matrice 200 V2. We report the root mean square difference (RMSD) and mean absolute difference (MAD) in particle number concentrations (PNCs) when mounted on the UAV and operating on the ground and when hovering at 10 m. When wind speeds are low (less than 2.6 m s –1 ), we find only modest differences in the RMSDs and MADs of 5 % and 3 % when operating at 10 m altitude. When wind speeds are between 2.6 and 7.7 m s –1 the RMSDs and MADs increase to 26.2 % and 19.1 %, respectively, when operating at 10m altitude. No statistical difference in PNCs was detected when operating on the UAV in either ascent or descent. We also find size distributions of aerosols in the accumulation mode (defined by diameter, d, where 0.1 ≤ d ≤ 1 µm) are relatively consistent between measurements at the surface and measurements at 10 m altitude, while differences in the coarse mode (here defined by d > 1 µm) are universally larger. Our results suggest that the impact of the UAV rotors on the POPS PNCs are small at low wind speeds, but when operating under a higher wind speed of up to 7.6 m s –1 , larger discrepancies occur. In addition, it appears that the POPS measures sub-micron aerosol particles more accurately than super-micron aerosol particles when airborne on the UAV. These measurements lay the foundations for determining the magnitude of potential errors that might be introduced into measured aerosol particle size distributions and concentrations owing to the turbulence created by the rotors on the UAV.

47 OTHER INSTRUMENTATION↗

Use of a Fourier transform spectrometer on a balloon-borne telescope and at the multiple mirror telescope (MMT)

The design and use of an infrared Fourier transform spectrometer which has been used for observations of laboratory, stratospheric, and astronomical spectra are described. The spectrometer has a spectral resolution of 0.032/cm and has operated in the mid-infrared (12 to 13 microns) as well as the far-infrared (40 to 140 microns), using both bolometer and photoconductor cryogenic detectors. The spectrometer is optically sized to accept an f/9 beam from the multi-mirror telescope (MMT). The optical and electronic design are discussed, including remote operation of the spectrometer on a balloon-borne 102-cm telescope. The performance of the laser-controlled, screw-driven moving cat's-eye mirror is discussed. Segments of typical far-infrared balloon flight spectra, lab spectra, and mid-infrared MMT spectra are presented. Data reduction, interferogram processing, artifact removal, wavelength calibration, and intensity calibration methods are discussed. Future use of the spectrometer is outlined.

Traub, W. A.↗

Miniature Incandescent Lamps as Fiber-Optic Light Sources

Miniature incandescent lamps of a special type have been invented to satisfy a need for compact, rapid-response, rugged, broadband, power-efficient, fiber-optic-coupled light sources for diverse purposes that could include calibrating spectrometers, interrogating optical sensors, spot illumination, and spot heating.

Tuma, Margaret↗

Fabrication of optical components for the ultraviolet spectrometer and polarimeter on the Solar Maximum Mission

The Solar Maximum Mission (SMM) satellite was launched in February 1980 into a 573 km high circular orbit. It contains X-ray, UV, and optical instruments for the simultaneous observation of solar flares. The ultraviolet spectrometer and polarimeter (UVSP) is one of these instruments. The objectives of the UVSP require the employment of a raster scanning telescope to study the spatial dynamics of flares, the use of a high resolution spectrometer to select and scan spectral lines for temperature and velocity diagnostics, and the utilization of a polarimeter to measure magnetic fields in the solar transition zone. The present paper has the objective to provide a description of the optical fabrication techniques developed for the instrument. Attention is given to telescope mirrors, metering rods, the Ebert mirror, grating blanks, a four-mirror polarizer, beam splitter assemblies, beam splitter fabrication, deflector mirrors, and shipping containers.

Spencer, R. S.↗

Heterodyne spectrometer sensitivity limit for quantum networking

We report optical heterodyne detection-based spectrometers are attractive due to their relatively simple construction and ultrahigh resolution. Here we demonstrate a proof-of-principle single-mode optical-fiber-based heterodyne spectrometer that has picometer resolution and quantum-limited sensitivity around 1550 nm. Moreover, we report a generalized quantum limit of detecting broadband multispectral-temporal-mode light using heterodyne detection, which provides a sensitivity limit on a heterodyne detection-based optical spectrometer. We then compare this sensitivity limit to several spectrometer types and dim light sources of interest such as spontaneous parametric downconversion, Raman scattering, and spontaneous four-wave mixing. We calculate that the heterodyne spectrometer is significantly less sensitive than a single-photon detector and is unable to detect these dim light sources, except for the brightest and narrowest-bandwidth examples.

47 OTHER INSTRUMENTATION↗

Use of aerosol microphysical measurements to model IR backscatter in support of GLOBE

Data on the concentration and composition of free tropospheric aerosol over the Pacific Ocean, collected during the GAMETAG program in 1977-1978 (Davis, 1980 and Patterson et al., 1980) are used to model values of aerosol optical extinction coefficients (sigma) at two wavelengths (0.55 and 1 micron) and values of volume backscatter coefficients (beta) at four wavelengths (1 micron, 9.11 microns, 9.25 microns, and 10.6 microns) and to investigate the relationship between these parameters. The mass concentrations inferred from the GAMETAG measurements with optical particle spectrometers agreed with the results of simultaneous chemical measurements. The study of the relationships among the optical parameters indicates that visible and near-visible values of beta and sigma may be useful in predicting 9.11- and 10.6-micron backscatter.

Patterson, Edward M.↗

Beam Shape Effects on Grating Spectrometer Resolution

The collimated optical beam in a grating spectrometer may be circular or elliptical in cross section, so that different parts of the beam illuminate different numbers of grooves on the grating. Here we estimate the consequent loss in spectral resolution relative to that obtained with a beam which illuminates a fixed number of grooves. For representative diffraction resolution functions, the effect is to reduce the intrinsic resolving power of the spectrometer by about 13%, exclusive of other contributions such as finite entrance slit width.

Erickson, Edwin F.↗

Design and Performance of a Spectrometer for Deployment on MISSE 7

A spectrometer for reflectance and transmission measurements of samples exposed to the space environment has been developed for deployment on the Materials on the International Space Station Experiment (MISSE) 7. The instrument incorporates a miniature commercial fiber optic coupled spectrometer with a computer control system for detector operation, sample motion and illumination. A set of three spectrometers were recently integrated on the MISSE7 platform with launch and deployment on the International Space Station scheduled for summer of this year. The instrument is one of many active experiments on the platform. The performance of the instrument prior to launch will be discussed. Data from samples measured in the laboratory will be compared to those from the instrument prior to launch. These comparisons will illustrate the capabilities of the current design. The space environment challenges many materials. When in operation on the MISSE 7 platform, the new spectrometer will provide real time data on the how the space environment affects the optical properties of thermal control paints and optical coatings. Data obtained from comparison of pre and post flight measurements on hundreds of samples exposed on previous MISSE platforms have been reported at these meetings. With the new spectrometer and the ability to correlate measured changes with time on orbit and the occurrence of both natural events and human activities, a better understanding of the processes responsible for degradation of materials in space will be possible.

Pippin, Gary↗

Characterization facility for magneto-optic media and systems

Objectives of this research are: (1) to measure the hysteresis loop, Kerr rotation angle, anisotropy energy profile, Hall voltage, and magnetoresistance of thin-film magneto-optic media using our loop-tracer; (2) measure the wavelength-dependence of the Kerr rotation angle, Theta(sub k), and ellipticity, epsilon(sub k), for thin-film media using our magneto-optic Kerr spectrometer (MOKS); (3) measure the dielectric tensor of thin-film and multilayer samples using our variable-angle magneto-optic ellipsometer (VAMOE); (4) measure the hysteresis loop, coercivity, remanent magnetization, saturation magnetization, and anisotropy energy constant for thin film magnetic media using vibrating sample magnetometry; (5) observe small magnetic domains and investigate their interaction with defects using magnetic force microscopy; (6) perform static read/write/erase experiments on thin-film magneto-optic media using our static test station; (7) integrate the existing models of magnetization, magneto-optic effects, coercivity, and anisotropy in an interactive and user-friendly environment, and analyze the characterization data obtained in the various experiments, using this modeling package; (8) measure focusing- and tracking-error signals on a static testbed, determine the 'feedthrough' for various focusing schemes, investigate the effects of polarization and birefringence, and compare the results with diffraction-based calculations; and (9) measure the birefringence of optical disk substrates using two variable angle ellipsometers.

Mansuripur, M.↗

NPFTURBULENCE: Best Estimate Aerosol Size Distribution by airborne measurements

The original data were collected during the field campaign of “Turbulent layers promoting New Particle Formation” experiment (NPFTURBULENCE; https://www.arm.gov/research/campaigns/aaf2024npfturbulence) over the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) Atmospheric Observatory (https://www.arm.gov/capabilities/observatories/sgp ) in north-central Oklahoma. The ARM Aerial Facility ArcticShark uncrewed aerial system (UAS) was based at Blackwell–Tonkawa Municipal Airport (IATA: BWL, ICAO: KBKN, FAA LID: BKN, 36.74475° N, 97.34918° W, 313.9 m MSL), for the field campaign from May 5 through May 29, 2024. The ArcticShark UAS performed 11 flights, including 10 research flights over the Central Facility of the ARM SGP to measure atmospheric state, turbulence, surface IT temperature and imagery, aerosol number concentration and size distribution. The current data set presents Best Estimate Aerosol Size Distribution: a merged aerosol size distribution composed of the data from 2 sensors: miniaturized Scanning Electrical Mobility Sizer (mSEMS) and Portable Optical Particle Spectrometer (POPS). The mSEMS data were interpolated to 1 second from “native” time resolution of about 15 second to match the other probe. The POPS data were converted from equivalent optical size into geometric size using value of aerosol refractive index of 1.477 from the HISCALE field campaign (same geographical area, altitudes, and time of year; http://www.arm.gov/campaigns/aaf2016hiscale ).

54 ENVIRONMENTAL SCIENCES↗

Diurnal and Seasonal Solar Induced Chlorophyll Fluorescence and Photosynthesis in a Boreal Scots Pine Canopy

Solar induced chlorophyll fluorescence has been shown to be increasingly an useful proxy for the estimation of gross primary productivity (GPP), at a range of spatial scales. Here, we explore the seasonality in a continuous time series of canopy solar induced fluorescence (hereafter SiF) and its relation to canopy gross primary production (GPP), canopy light use efficiency (LUE), and direct estimates of leaf level photochemical efficiency in an evergreen canopy. SiF was calculated using infilling in two bands from the incoming and reflected radiance using a pair of Ocean Optics USB2000+ spectrometers operated in a dual field of view mode, sampling at a 30 min time step using custom written automated software, from early spring through until autumn in 2011. The optical system was mounted on a tower of 18 m height adjacent to an eddy covariance system, to observe a boreal forest ecosystem dominated by Scots pine. (Pinus sylvestris) A Walz MONITORING-PAM, multi fluorimeter system, was simultaneously mounted within the canopy adjacent to the footprint sampled by the optical system. Following correction of the SiF data for O2 and structural effects, SiF, SiF yield, LUE, the photochemicsl reflectance index (PRI), and the normalized difference vegetation index (NDVI) exhibited a seasonal pattern that followed GPP sampled by the eddy covariance system. Due to the complexities of solar azimuth and zenith angle (SZA) over the season on the SiF signal, correlations between SiF, SiF yield, GPP, and LUE were assessed on SZA <50° and under strictly clear sky conditions. Correlations found, even under these screened scenarios, resulted around ~r2 = 0.3. The diurnal responses of SiF, SiF yield, PAM estimates of effective quantum yield (ΔF/Fm′), and meteorological parameters demonstrated some agreement over the diurnal cycle. The challenges inherent in SiF retrievals in boreal evergreen ecosystems are discussed.

photosynthetic↗

Design of the ion-optics for the MRSt neutron spectrometer at the National Ignition Facility (NIF)

A new Magnetic Recoil Spectrometer (MRSt) is designed to provide time-resolved measurements of the energy spectrum of neutrons emanating from an inertial confinement fusion implosion at the National Ignition Facility. At present, time integrated parameters are being measured using the existing magnet recoil and neutron time-of-flight spectrometers. The capability of high energy resolution of 2 keV and the extension to high time resolution of about 20 ps are expected to improve our understanding of conditions required for successful fusion experiments. The layout, ion-optics, and specifications of the MRSt will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity of Inherent Optical Properties from Ocean Reflectance Inversion Models to Satellite Instrument Wavelength Suites

The Earth science community seeks to develop climate data records (CDRs) from satellite measurements of ocean color, a continuous data record that now exceeds 20 years. Space agencies will launch additional instruments in the coming decade that will continue this data record, including the NASA PACE spectrometer. Inherent optical properties (IOPs) quantitatively describe the absorbing and scattering constituents of seawater and can be estimated from satellite-observed spectroradiometric data using semi-analytical algorithms (SAAs). SAAs exploit the contrasting optical signatures of constituent matter at spectral bands observed by satellite sensors. SAA performance, therefore, depends on the spectral resolution of the satellite spectroradiometer. A CDR spanning SeaWiFS, MODIS, OLCI, and PACE, for example, would include IOPs derived using varied wavelength suites if all available wavelengths were considered. Here, we explored differences in derived IOPs that stem simply from the use of (eight) different wavelength suites of input radiometric measurements. Using synthesized data and SeaWiFS Level-3 mission-long composites, we demonstrated equivalent SAA performance for all wavelength suites, but that IOP retrievals vary by several percent across wavelength suites and as a function of water type. The differences equate to roughly ≤ 6, 12, and 7% for a(sub dg)(443), a(sub ph)(443), and b(sub bp)(443), respectively, for waters with C(sub a) ≤ 1 mg -cu m. These values shrink for sensors with similar wavelength suites (e.g., SeaWiFS, MODIS, and MERIS) and rise to substantially larger values for higher C(sub a) waters. Our results also indicate that including 400 nm (in the case of OLCI) influences the derived IOPs, using longer wavelengths (>600 nm) influences the derived IOPs when there is a red signal, and, including additional spectral information shows potential for improved IOP estimation, but not without revisiting SAA parameterizations and execution. While modest in scope, we believe this study contributes to the knowledge base for CDR development. The implication of ignoring such an analysis as CDRs continue to be developed is a prolonged inability to distinguish between algorithmic and environmental contributions to trends and anomalies in the IOP time-series.

ocean color satellites↗

A rare gas optics-free absolute EUV photon spectrometer for solar system studies

We have developed a prototype spectrometer for space applications which require long term absolute EUV photon flux measurements. In this recently developed spectrometer, the energy spectrum of the incoming photons is transformed directly into an electron energy spectrum by taking advantage of the photoelectric effect in one of several rare gases at low pressures. Using an electron energy spectrometer operating at a few eV, and followed by an electron multiplying detector, pulses due to individual electrons are counted. The overall efficiency of this process is essentially independent of gain drifts in the signal path, and the secular degradation of optical components which is often a problem in other techniques is avoided.

Daybell, M. D.↗

The SHMS 11 GeV/c spectrometer in Hall C at Jefferson Lab

The Super High Momentum Spectrometer (SHMS) has been built for Hall C at the Thomas Jefferson National Accelerator Facility (Jefferson Lab). With a momentum capability reaching 11 GeV/ c , the SHMS provides measurements of charged particles produced in electron-scattering experiments using the maximum available beam energy from the upgraded Jefferson Lab accelerator. The SHMS is an ion-optics magnetic spectrometer comprised of a series of new superconducting magnets which transport charged particles through an array of triggering, tracking, and particle-identification detectors that measure momentum, energy, angle and position in order to allow kinematic reconstruction of the events back to their origin at the scattering target. The detector system is protected from background radiation by a sophisticated shielding enclosure. The entire spectrometer is mounted on a rotating support structure which permits measurements to be taken with a large acceptance over laboratory scattering angles from 5.5° to 40°, thus allowing a wide range of low cross-section experiments to be conducted. Finally, these experiments complement and extend the previous Hall C research program to higher energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

CNO Processing in Massive Algol Binaries

This program, used ultraviolet observations by the IUE Observatory along with other tools to search for abundance anomalies indicative of CNO processing in the secondary (mass-donating) stars of six interacting binary systems. Related IUE-based activities were also undertaken under this grant. Two Supplements to the grant were awarded. Supplement No. 1 was in connection with the NASA Grant Supplements for Education program, for a workshop for elementary school science teachers. The two sessions of the workshop were held October 24 and November 14, 1992. Eighteen school teachers from central Pennsylvania, grades 1-7, participated in the workshop, for which they received one unit of in-service training credit from their Intermediate Unit. Supplement No. 2 was awarded for additional IUE observations of the Algol stars V342 Aql and TU Mon. Observations of all six candidate stars were made with IUE, and attention was narrowed to TU Mon in particular, for which further IUE observations were made using Director's discretionary time. Observations of TU Mon were also carried out with the Voyager UV spectrometers, and optical spectroscopy was obtained on several occasions at Penn State's Black Moshannon Observatory. Photometric data on TU Mon were acquired by Dr. Paul Etzel at Mt. Laguna Observatory (MLO). McGouldrick was employed part-time during the Fall academic semester to assist in accessing the IUE Archive, and to correlate data on some cataclysmic variables and related objects that were observed with both IUE and the Voyager Far Ultraviolet Spectrometers. Approximately 21 relevant binary systems were observed with the Voyager UVS over the past decade, and a paper is being prepared for eventual publication that will serve as an index to the UVS data archive on these stars, providing observation dates, mean count rates in far and extreme UV bands, and a discussion of the relevant literature concerning the far UV behavior (including correlative IUE information from the archive and the literature). Much of the activity under the grant was in connection with V342 Aquilae, a 3.39 day Algol system thought to be in a state of rapid mass transfer. The goal was to combine optical and ultraviolet data to arrive at a robust, informative interpretation of this unique binary system. Complete orbital phase coverage of V342 Aql was obtained spectroscopically and photometrically.

Wade, Richard A.↗