Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Field Validation of Cloud Properties Sensor (SAIL Field Campaign Report)

The purpose of the Field Validation of Cloud Properties Sensor – SAIL campaign was to deploy Aerodyne’s extended-wavelength TWST cloud optical properties sensor (TWST-CPS) in an operationally relevant environment with co-located, externally validated sensors. Colocation with The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s deployment of its second Mobile Facility (AMF2) on the Surface Atmosphere Integrated Field Laboratory (SAIL) campaign at Crested Butte, Colorado was ideal because of the variety of operational sensors that can measure some of the same cloud properties using different modalities. While cloud property sensors have long existed, they tend to be costly to produce and maintain. Our sensor measures absolute spectral radiance over 440-1700 nm and retrieves cloud optical depth (COD), droplet effective radius (Reff), and thermodynamic phase (Phase). Our prototype is built predominantly from off-the-shelf components and uses uncooled spectrometers. A low-cost, easy-to-use sensor such as this could allow deployment at many more sites for greater spatial coverage. Instrument deployment to test robust operations and a new stray-light baffle design, and the continued development of analysis and retrieval algorithms using the data from this deployment, are central technical objectives of Aerodyne Research’s U.S. Department of Energy Small Business Innovative Research Phase 2 contract (DE-SC0020473, Low-cost shortwave spectroradiometer for retrieval of cloud properties).

54 ENVIRONMENTAL SCIENCES↗

Field Validation of Cloud Properties Sensor – SAIL Field Campaign Report

The purpose of the Field Validation of Cloud Properties Sensor – SAIL campaign was to deploy Aerodyne’s extended-wavelength TWST cloud optical properties sensor (TWST-CPS) in an operationally relevant environment with co-located, externally validated sensors. Colocation with The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s deployment of its second Mobile Facility (AMF2) on the Surface Atmosphere Integrated Field Laboratory (SAIL) campaign at Crested Butte, Colorado was ideal because of the variety of operational sensors that can measure some of the same cloud properties using different modalities. While cloud property sensors have long existed, they tend to be costly to produce and maintain. Our sensor measures absolute spectral radiance over 440-1700 nm and retrieves cloud optical depth (COD), droplet effective radius (Reff), and thermodynamic phase (Phase). Our prototype is built predominantly from off-the-shelf components and uses uncooled spectrometers. A low-cost, easy-to-use sensor such as this could allow deployment at many more sites for greater spatial coverage. Instrument deployment to test robust operations and a new stray-light baffle design, and the continued development of analysis and retrieval algorithms using the data from this deployment, are central technical objectives of Aerodyne Research’s U.S. Department of Energy Small Business Innovative Research Phase 2 contract (DE-SC0020473, Low-cost shortwave spectroradiometer for retrieval of cloud properties).

54 ENVIRONMENTAL SCIENCES↗

Design and Construction of a High-Resolution Hodoscope for the GlueX Experiment with High-Statistics Analysis of the p0, ¿, and ¿1 Photoproduction Cross Sections from the RadPhi Experiment

Differential cross sections for forward-angle photoproduction of p0, ¿, and ¿ 1 pseudoscalar mesons were measured using data from the RadPhi experiment conducted in Hall B at Jef ferson Lab. RadPhi utilized a tagged bremsstrahlung photon beam incident on a stationary 9Be target, with a detector system configured to trigger on a recoil proton in coincidence with multiple neutral showers in the calorimeter. Events were reconstructed and subjected to kinematic constraints, with background suppressed via sideband subtraction guided by Monte Carlo modeling of background contributions. Cross sections were extracted over the photon energy range 4.4– 5.4 GeV and binned in invariant momentum transfer t, providing measurements from one of the first high-statistics experiments of forward ¿ and ¿1 pro duction from a nuclear target at these energies. Acceptance corrections were applied using a detailed GEANT-based simulation of the detector geometry and response. The resulting cross sections are consistent with 2020 CLAS results, when scaled by the number of protons in beryllium, and show broad agreement with other data and theoretical models. In parallel, a high-resolution photon tagger detector, the Tagger Microscope (TAGM), was designed, constructed, and commissioned for the GlueX experiment in Hall D at Jefferson Lab. The TAGM was developed to provide high-rate tagging capability in the coherent bremsstrahlung peak by detecting post-bremsstrahlung electrons across a one GeV range along the focal plane of the tagging spectrometer. The detector consists of a 5ˆ102 array of 2ˆ2 mm2 square BCF-20 plastic scintillating fibers thermally fused to BCF-98 light guide fibers optically coupled to silicon photomultipliers. These fibers are mounted in a precision machined framework enabling fine positional adjustments to maintain precise alignment with post-bremsstrahlung electron trajectories, while ensuring mechanical rigidity, thermal stability, optical isolation, minimal inactive area, and radiation shielding for electronics. The construction effort involved extensive testing of fiber quality, light transmission, thermal fusing, radiation hardness, and defect analysis using SEM and EDX techniques. Following its installation and commissioning, the TAGM became a critical component of the GlueX beamline, enabling high-rate tagging essential for studies of hybrid mesons and gluonic ex citations.

McIntyre, James [Univ. of Connecticut, Storrs, CT ↗

First field test of a novel optical gas analyser in the exhaust of Wendelstein 7-X

A novel optical gas analyser, designed for isotope-resolved exhaust composition measurement, was field-tested at Wendelstein 7-X (W7-X) to validate its laboratory-proven concept under operational fusion experiment conditions. The system, Optix, comprises a cold cathode remote plasma generator and a high-resolution Fabry–Perot spectrometer and was deployed in the exhaust line of W7-X during the OP2.3 campaign. The injection of 3 He and 4 He for minority ion-cyclotron heating provided a test case for helium isotope discrimination. Despite limitations due to background gas and low partial pressures of the target species, isotope-resolved spectral signatures were successfully observed, demonstrating the fundamental viability of the Optix approach. Additionally, the spectrometer was evaluated for plasma emission measurements from both core and edge sightlines. While helium line emission was detectable, interpretation was hindered by complex background signals, highlighting the benefits of controlled remote plasma generators for spectroscopy. This first deployment provides critical insight into pressure requirements, spectral resolution, and operational constraints, informing future applications of optical exhaust diagnostics in fusion devices.

magnetic confinement fusion↗

Understanding the Impacts of Stellar Companions on Planet Formation and Evolution: A Survey of Stellar and Planetary Companions within 25 pc

We explore the impact of outer stellar companions on the occurrence rate of giant planets detected with radial velocities. We searched for stellar and planetary companions to a volume-limited sample of solar-type stars within 25 pc. Using adaptive optics imaging observations from the Lick 3 m and Palomar 200″ Telescopes, we characterized the multiplicity of our sample stars, down to the bottom of the main sequence. With these data, we confirm field star multiplicity statistics from previous surveys. We additionally combined three decades of radial velocity (RV) data from the California Planet Search with newly collected RV data from Keck/HIRES and the Automated Planet Finder/Levy Spectrometer to search for planetary companions in these same systems. Using an updated catalog of both stellar and planetary companions, as well as detailed injection/recovery tests to determine our sensitivity and completeness, we measured the occurrence rate of planets among the single- and multiple-star systems. We found that planets with masses in the range of 0.1–10 M {sub J} and with semimajor axes of 0.1–10 au have an occurrence rate of 0.18{sub −0.03}{sup +0.04} planets per star when they orbit single stars and an occurrence rate of 0.12 ± 0.04 planets per star when they orbit a star in a binary system. Breaking the sample down by the binary separation, we found that only one planet-hosting binary system had a binary separation <100 au, and none had a separation <50 au. These numbers yielded planet occurrence rates of 0.20{sub −0.06}{sup +0.07} planets per star for binaries with separation a {sub B} > 100 au and 0.04{sub −0.02}{sup +0.04} planets per star for binaries with separation a {sub B} < 100 au. The similarity in the planet occurrence rate around single stars and wide primaries implies that wide binary systems should actually host more planets than single-star systems, since they have more potential host stars. We estimated a system-wide planet occurrence rate of 0.3 planets per wide binary system for binaries with separations a {sub B} > 100 au. Finally, we found evidence that giant planets in binary systems have a different semimajor-axis distribution than their counterparts in single-star systems. The planets in the single-star sample had a significantly higher occurrence rate outside of 1 au than inside 1 au by nearly 4σ, in line with expectations that giant planets are most common near the snow line. However, the planets in the wide binary systems did not follow this distribution, but rather had equivalent occurrence rates interior and exterior to 1 au. This may point to binary-mediated planet migration acting on our sample, even in binaries wider than 100 au.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chirped-grating spectrometer-on-a-chip

We demonstrate an on-chip spectrometer readily integrable with CMOS electronics. The structure is comprised of a SiO 2 /Si 3 N 4 /SiO 2 waveguide atop a silicon substrate. A transversely chirped grating is fabricated, in a single-step optical lithography process, on a portion of the waveguide to provide angle and wavelength dependent coupling to the guided mode. The spectral and angular information is encoded in the spatial dependence of the grating period. A uniform pitch grating area, separated from the collection area by an unpatterned propagation region, provides the out-coupling to a CMOS detector array. A resolution of 0.3 nm at 633 nm with a spectral coverage tunable across the visible and NIR (to ∼ 1 µm limited by the Si photodetector) by changing the angle of incidence, is demonstrated without the need for any signal processing deconvolution. This on-chip spectrometer concept will cost effectively enable a broad range of applications that are beyond the reach of current integrated spectroscopic technologies.

Nezhadbadeh, Shima↗

A beamline for ultrafast extreme ultraviolet magneto-optical spectroscopy in reflection near the shot noise limit

High harmonic generation (HHG) makes it possible to measure spin and charge dynamics in materials on femtosecond to attosecond timescales. However, the extreme nonlinear nature of the high harmonic process means that intensity fluctuations can limit measurement sensitivity. Here we present a noise-canceled, tabletop high harmonic beamline for time-resolved reflection mode spectroscopy of magnetic materials. We use a reference spectrometer to independently normalize the intensity fluctuations of each harmonic order and eliminate long term drift, allowing us to make spectroscopic measurements near the shot noise limit. Here, these improvements allow us to significantly reduce the integration time required for high signal-to-noise (SNR) measurements of element-specific spin dynamics. Looking forward, improvements in the HHG flux, optical coatings, and grating design can further reduce the acquisition time for high SNR measurements by 1–2 orders of magnitude, enabling dramatically improved sensitivity to spin, charge, and phonon dynamics in magnetic materials.

47 OTHER INSTRUMENTATION↗

Temperature-dependent optical constants of vanadium dioxide thin films deposited on polar dielectrics

Coating polar dielectrics with thin film vanadium dioxide (VO 2 ) enables one to exploit the temperature-dependent phase transition within VO 2 to actively tune and modulate surface phonon polaritons at mid-infrared. However, controlling the behavior of such systems requires intimate knowledge of the temperature-dependent optical constants of VO 2 , which depend greatly on the growth conditions and substrate material. Here, in this work, we accurately determine the complex optical constants of VO 2 on polar dielectrics across the insulator-to-metal phase transition (IMT) using only normal incident reflectance spectra by analyzing the reflectance with Kramers–Kronig relations and thin film Fresnel equations. This non-ellipsometry technique offers an advantage in determining the refractive index using a standard infrared spectrometer.

36 MATERIALS SCIENCE↗

Design and implementation of a portable diagnostic system for Thomson scattering and optical emission spectroscopy measurements

A diagnostic system, which has a design goal of high-portability, has been designed at Oak Ridge National Laboratory (ORNL). This project aims at providing measurements of key plasma parameters (ne, Te, ni, Ti) for fusion-relevant devices, utilizing Thomson scattering (TS) and optical emission spectroscopy (OES). The innovative design employs mostly commercial off-the-shelf instrumentation and a traveling team of researchers to conduct measurements at various magnetic-confinement plasma devices. The TS diagnostic uses a Quantel Q-smart 1500 Nd:YAG laser with a 2ω harmonic generator to produce up to 850 mJ of 532 nm laser pulses at 10 Hz. Collection optics placed at the detection port consists of an 11 × 3 optical fiber bundle, where the TS diagnostic uses an 11 × 1 subset array of the fibers, the OES diagnostic uses another 11 fibers, and the remaining fibers are available to the host institution. The detection system is comprised of two separate IsoPlane-320 spectrometers with triple-grating turrets of various line spacing and two PI-MAX 4 intensified CCD detectors, used simultaneously to measure a broad range of ion, impurity, and electron parameters. The self-contained diagnostic package also includes a data processing and storage system. The design and initial implementation of the TS-OES diagnostic system are described. The experiments from the proof-of-principle operation of the portable package on a high density (∼2.5 × 1022 m−3) and low-temperature (∼5 eV) electrothermal arc source at ORNL are also discussed.

Kafle, N. (ORCID:000000028144787X)↗

Single-Cell Metabolomics with Rapid Determination of Chemical Formulas from Isotopic Fine Structures

Metabolomic measurements can provide functional readouts of cellular states and phenotypes. Here, we present a protocol for single-cell metabolomics that permits direct untargeted detection of a broad number of metabolites under ambient conditions, without the need for sample processing, and with high confidence in the discovery and identification of the molecular formulas for detected metabolites. This protocol describes combining fiber-based laser ablation electrospray ionization (f-LAESI) with a 21 Tesla Fourier transform ion cyclotron resonance mass spectrometer (21T-FTICR-MS) to obtain high confidence molecular formula information about detected metabolites. The f-LAESI source utilizes mid-infrared laser ablation through a sharp optical fiber tip, affording direct ambient analysis of cells without the need for sample processing. Using the 21T-FTICR-MS as a mass analyzer enabled measurement of the isotopic fine structure (IFS) for numerous metabolites simultaneously from single cells, and the IFSs were in turn computationally processed to rapidly determine the corresponding elemental compositions. This metabolomics technique complements other single cell omics measurement methods, helping to resolve complex molecular interactions that take place within cells unattainable from single cell transcriptomic and proteomics methods.

mass spectrometry, FTICR, FTMS, ultrahigh mass res↗

Considerations in upconversion: A practical guide to sum-frequency generation spectrometer design and implementation

Here, in this tutorial review, we discuss how the choice of upconversion pulse shape in broadband vibrational sum-frequency generation (SFG) spectrometer design impacts the chemical or physical insights one can obtain from a set of measurements. A time-domain picture of a vibrational coherence being mapped by a second optical field is described and the implications of how this mapping, or upconversion process, takes place are given in the context of several popular and emerging approaches found in the literature. Emphasis is placed on broadband frequency-domain measurements, where the choice of upconversion pulse enhances or limits the information contained in the SFG spectrum. We conclude with an outline for a flexible approach to SFG upconversion using pulse-shaping methods and a simple guide to design and optimize the associated instrumentation.

47 OTHER INSTRUMENTATION↗

Optical Microscopy-Guided Laser Ablation Electrospray Ionization Ion Mobility Mass Spectrometry: Ambient Single Cell Metabolomics with Increased Confidence in Molecular Identification

Single cell analysis is a field of increasing interest as new tools are continually being developed to understand intercellular differences within large cell populations. Laser-ablation electrospray ionization mass spectrometry (LAESI-MS) is an emerging technique for single cell metabolomics. Over the years, it has been validated that this ionization technique is advantageous for probing the molecular content of individual cells in situ. Here, we report the integration of a microscope into the optical train of the LAESI source to allow for visually informed ambient in situ single cell analysis. Additionally, we have coupled this ‘LAESI microscope’ to a drift-tube ion mobility mass spectrometer to enable separation of isobaric species and allow for the determination of ion collision cross sections in conjunction with accurate mass measurements. This combined information helps provide higher confidence for structural assignment of molecules ablated from single cells. Here, we show that this system enables the analysis of the metabolite content of Allium cepa epidermal cells with high confidence structural identification together with their spatial locations within a tissue.

59 BASIC BIOLOGICAL SCIENCES↗

The Experimental Programs on Light Pseudoscalar Meson Decays

The decays of the low-lying pseudoscalar mesons (?0, ?, and ??) allow access to a plethora of physics probes, from measurements of fundamental properties of matter such as the up-down quark mass ratio, to studies of channels that access higher-order terms in Chiral Perturbation theory, to tests of fundamental symmetries and searches for signatures of physics beyond the Standard Model. Several experiments have studied pseudoscalar decays: these experiments include PrimEx in Hall B at Jefferson Lab, A2 at the MAMI electron accelerator facility, the KLOE-II experiment at the DA?NE ?-factory, WASA-at-COSY at the cooler synchrotron COSY storage ring, and BESIII at the Beijing charm factory. In Hall D at Jefferson Lab, PrimEx-eta uses the Primakoff process to measure the ? radiative width using the GlueX spectrometer. In the near future the Jefferson Lab Eta Factory (JEF) experiment will use the GlueX spectrometer with an upgraded forward calorimeter to study ?(?) decay channels with a focus on all-neutral final states. Finally, a proposal for a new experiment, ``Rare Eta Decays with a TPC for Optical Photons'' (REDTOP) utilizing a proton beam on fixed targets, is under development. Highlights from previous and ongoing experiments and plans for future experiments will be presented.

Taylor, Simon↗

Performance Optimization of the IOTA Duoplasmatron Proton Source

We present results from online optimization studies of a duoplasmatron ion source designed to produce 50~keV protons for acceleration to 2.5~MeV and subsequent injection into the Integrable Optics Test Accelerator (IOTA) at Fermilab. Using a Bayesian exploration technique, we developed multi-parameter models of the source s proton current and employed these models to optimize its performance. Depending on the spectrometer configuration used to isolate the proton beam and the chosen optimization objective, we identified three candidate operating points, achieving normalized 50~\% emittances between 0.57 and 1.3~\textmu m and a maximum proton current of $14.5 \pm 0.6$~mA.

Banerjee, Nilanjan [Fermilab] (ORCID:0000000344660↗

Moderate spectral resolution solar irradiance measurements, aerosol optical depth, and solar transmission, from 360 to 1070 nm, using the refurbished rotating shadow band spectroradiometer (RSS)

Abstract. This paper reports on a third-generation rotating shadow band spectroradiometer (RSS) used to measure global and diffuse horizontal plus direct normal irradiances and transmissions at 1002 wavelengths between 360 and 1070 nm. The prism-dispersed spectral data are from the Atmospheric Radiation Measurement (ARM) Southern Great Plains site in north-central Oklahoma (36.605∘ N, 97.486∘ W) and cover dates between August 2009 and February 2014. The refurbished RSS isolates the detector in a vacuum chamber with pressures near 10−7 torr. This prevents the deposition of outgassed vapors from the interior of the spectrometer shell on the cooled detector that affected the operation of the first commercial RSS. Methods for (1) ensuring the correct wavelength registration of the data and (2) deriving extraterrestrial responses over the entire spectrum, including throughout strong water vapor and oxygen bands, are described. The resulting data produced are archived as ARM data records and include cloud-screened aerosol optical depths, spectral irradiances and direct normal solar transmission, as well as normalized diffuse and global irradiances.

54 ENVIRONMENTAL SCIENCES↗

Mid- to long-wave infrared computational spectroscopy with a graphene metasurface modulator

In recent years there has been much interest concerning the development of modulators in the mid- to long-wave infrared, based on emerging materials such as graphene. These have been frequently pursued for optical communications, though also for other specialized applications such as infrared scene projectors. Here we investigate a new application for graphene modulators in the mid- to long-wave infrared. We demonstrate, for the first time, computational spectroscopy in the mid- to long-wave infrared using a graphene-based metasurface modulator. Furthermore, our metasurface device operates at low gate voltage. To demonstrate computational spectroscopy, we provide our algorithm with the measured reflection spectra of the modulator at different gate voltages. We also provide it with the measured reflected light power as a function of the gate voltage. The algorithm then estimates the input spectrum. We show that the reconstructed spectrum is in good agreement with that measured directly by a Fourier transform infrared spectrometer, with a normalized mean-absolute-error (NMAE) of 0.021.

36 MATERIALS SCIENCE↗

Li Isotope Signatures using Optical Spectroscopies

The primary goal of this work is to investigate the detection capabilities of laser ablation molecular isotopic spectrometry (LAMIS) and Raman spectroscopy for lithium isotopic determination as related to Li enrichment activities. LAMIS is an emerging spectroscopic technique that takes advantage of the fact that molecules exhibit much larger isotopic wavelength shifts in molecular emission spectra than their atomic counterparts. Raman spectroscopy has been shown to exhibit isotopic shifts if a given molecular vibration involves the isotope of interest. Both techniques are comprised of the same basic hardware: a spectrometer, a laser system (pulsed for LAMIS, pulsed or CW for Raman), and an intensified charge-coupled device (ICCD). Shifts in Raman spectra due to lithium isotopes in Li 2 C0 3 and LiOH*H 2 0 were observed. LAMIS measurements of the same compounds have not been successful yet, as no lithium containing molecular emissions have been identified to this point. However, an isotopic shift of the self-reversal of an atomic lithium emission was observed, which is another optical technique used to measure isotopes.

07 ISOTOPE AND RADIATION SOURCES↗