Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Parallel image logical operations using cross correlation

Methods are presented for counting areas in an image in a parallel manner using noncoherent optical techniques. The techniques presented include the Levialdi algorithm for counting, optical techniques for binary operations, and cross-correlation.

Strong, J. P., III↗

Development of Grazing Incidence Optics for Neutron Imaging and Scattering

Because of their wave nature, thermal and cold neutrons can be reflected from smooth surfaces at grazing incidence angles, be reflected by multilayer coatings or be refracted at boundaries of different materials. The optical properties of materials are characterized by their refractive indices which are slightly less than unity for most elements and their isotopes in the case of cold and thermal neutrons as well as for x-rays. The motivation for the optics use for neutrons as well as for x-rays is to increase the signal rate and, by virtue of the optic's angular resolution, to improve the signal-to-noise level by reducing the background so the efficiency of the existing neutron sources use can be significantly enhanced. Both refractive and reflective optical techniques developed for x-ray applications can be applied to focus neutron beams. Typically neutron sources have lower brilliance compared to conventional x-ray sources so in order to increase the beam throughput the neutron optics has to be capable of capturing large solid angles. Because of this, the replicated optics techniques developed for x-ray astronomy applications would be a perfect match for neutron applications, so the electroformed nickel optics under development at the Marshall Space Flight Center (MSFC) can be applied to focus neutron beams. In this technique, nickel mirror shells are electroformed onto a figured and superpolished nickel-plated aluminum cylindrical mandrel from which they are later released by differential thermal contraction. Cylindrical mirrors with different diameters, but the same focal length, can be nested together to increase the system throughput. The throughput can be increased further with the use of the multilayer coatings deposited on the reflectivr surface of the mirror shells. While the electroformed nickel replication technique needs to be adopted for neutron focusing, the technology to coat the inside of cylindrical mirrors with neutron multilayers has to be developed. The availability of these technologies would bring new capabilities to neutron instrumentation and, hence, lead to new scientific breakthroughs. We have established a program to adopt the electroformed nickel replication optics technique for neutron applications and to develop the neutron multilayer replication technology.

Gubarev, M. V.↗

X-ray optics - A technique for high resolution imaging

Both scattering and figure errors in grazing incidence optics are larger in the plane of incidence than out-of-plane by a factor equal to 1/sin theta, where theta is the graze angle. When the full annular aperture of a grazing incidence telescope is stopped down, the point spread function becomes highly elliptical with a width as much as sin theta times narrower than the full image. In practice, this means that improvements in resolution of up to 100 times can be achieved, and effective resolution can approach the diffraction limit. Laboratory data demonstrating the effect are presented.

Cash, Webster↗

The development of optical microscopy techniques for the advancement of single-particle studies

Single particle orientation and rotational tracking (SPORT) has recently become a powerful optical microscopy tool that can expose many molecular motions. Unfortunately, there is not yet a single microscopy technique that can decipher all particle motions in all environmental conditions, thus there are limitations to current technologies. Within, the two powerful microscopy tools of total internal reflection and interferometry are advanced to determine the position, orientation, and optical properties of metallic nanoparticles in a variety of environments. Total internal reflection is an optical phenomenon that has been applied to microscopy to produce either fluorescent or scattered light. The non-invasive far-field imaging technique is coupled with a near-field illumination scheme that allows for better axial resolution than confocal microscopy and epi-fluorescence microscopy. By controlling the incident illumination angle using total internal reflection fluorescence (TIRF) microscopy, a new type of imaging probe called “non-blinking” quantum dots (NBQDs) were super-localized in the axial direction to sub-10-nm precision. These particles were also used to study the rotational motion of microtubules being propelled by the motor protein kinesin across the substrate surface. The same instrument was modified to function under total internal reflection scattering (TIRS) microscopy to study metallic anisotropic nanoparticles and their dynamic interactions with synthetic lipid bilayers. Utilizing two illumination lasers with opposite polarization directions at wavelengths corresponding to the short and long axis surface plasmon resonance (SPR) of the nanoparticles, both the in-plane and out-of-plane movements of many particles could be tracked simultaneously. When combined with Gaussian point spread function (PSF) fitting for particle super-localization, the binding status and rotational movement could be resolved without degeneracy. TIRS microscopy was also used to find the 3D orientation of stationary metallic anisotropic nanoparticles utilizing only long-axis SPR enhancement. The polarization direction of the illuminating light was rotated causing the relative intensity of p-polarized and s-polarized light within the evanescent field to change. The interaction of the evanescent field with the particles is dependent on the orientation of the particle producing an intensity curve. This curve and the in-plane angle can be compared with simulations to accurately determine the 3D orientation. Differential interference contrast (DIC) microscopy is another non-invasive far-field technique based upon interferometry that does not rely on staining or other contrast enhancing techniques. In addition, high numerical aperture condensers and objectives can be used to give a very narrow depth of field allowing for the optical tomography of samples, which makes it an ideal candidate to study biological systems. DIC microscopy has also proven itself in determining the orientation of gold nanorods in both engineered environments and within cells. Many types of nanoparticles and nanostructures have been synthesized using lithographic techniques on silicon wafer substrates. Traditionally, reflective mode DIC microscopes have been developed and applied to the topographical study of reflective substrates and the imaging of chips on silicon wafers. Herein, a laser-illuminated reflected-mode DIC was developed for studying nanoparticles on reflective surfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of GLAD technique on optical properties of ZnS multilayer antireflection coatings

Highlights: • ZnS multi-layer antireflection coatings have been prepared by GLAD technique. • XRD analysis depicts that all the multi-layer samples are crystallized in cubic structure. • FESEM images confirmed the multi-layer and inclined formation of specimens. • Transmission increment and refractive index decrement obtained for the multi-layer samples. • Incredible impression of GLAD technique on multi-layer coatings is realized. - Abstract: In this work, we prepared Zinc sulfide (ZnS) multi-layer antireflection coatings applying glancing angle deposition (GLAD) technique by physical vapor deposition method. By comparing the structural and optical properties of the samples prepared at normal and inclined single layer coatings, salient effect of multi-layer coatings composed of normal and inclined layers are observed. Relative improvement in crystallinity of the GLAD produced films with respect to inclined single layer resulted from X-ray diffraction (XRD) studies. Despite high increment in average transmission, explicit reduction in refractive index of the multilayer specimens are obtained by Ultraviolet–visible spectroscopy (UV–VIS) analysis. Both the abovementioned changes are in the direction of improving the anti-reflectivity features.

36 MATERIALS SCIENCE↗

Transient Heat Transfer in Zero Gravity Environment

The objective is to provide computer codes and/or correlations for application in the design of transient heat transfer systems. The mathematical models in the computer codes are being tested by experimental data obtained in the laboratory using optical techniques. The elimination of natural convection (buoyancy) in the experimental data obtained in zero-g (KC-135) facilitates the study of thermal expansion effects which is of interest in the development and testing of the mathematical models of the transient heat transfer. Initial flight in the KC 135 (June 1983) suggested some modifications to the experimental apparatus and the data acquisition technique (high speed video will replace high speed movies for recording optical records generated during the experiments). A series of KC-135 flights with this experiment on board are scheduled for summer/fall 1984. The acquisition of the aforementioned data using interferometry and beam deflection optical techniques is anticipated. The measurements provide time dependent temperature fields above a horizontal heater surface submerged in a static fluid (Freon 13). The heater surface is electrically heated for a time interval approximately 0.100 sec. during which the data are optically recorded.

Giarratano, P. G.↗

Neutron, fluorescence, and optical imaging: An in situ combination of complementary techniques

An apparatus which enables the simultaneous combination of three complementary imaging techniques, optical imaging, fluorescence imaging, and neutron radiography, is presented. While each individual technique can provide information on certain aspects of the sample and their time evolution, a combination of the three techniques in one setup provides a more complete and consistent data set. The setup can be used in transmission and reflection modes and thus with optically transparent as well as opaque samples. Its capabilities are illustrated with two examples. A polymer hydrogel represents a transparent sample and the diffusion of fluorescent particles into and through this polymer matrix is followed. In reflection mode, the absorption of solvent by a nile red-functionalized mesoporous silica powder and the corresponding change in fluorescent signal are studied.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Review of grazing incidence optics fabrication techniques for X-ray astronomy

This paper covers the various techniques that are currently being used and developed to fabricate grazing incidence X-ray optics for the energy range from about 0.2 to 20 keV. Techniques covered will include diamond turning, thin foils, epoxy/carbon-fiber replication, electroforming replication, and float glass/Kirkpatrick-Baez techniques.

Ulmer, Melville P.↗

Electro-Optical Measurement Techniques

Utilize the unique characteristics of photons across different regions of the electromagnetic spectrum to probe the optical and electronic properties of chemical systems, materials and devices for energy conversion technologies.

absorption↗

Optical data processing analysis of stream patterns exhibited on ERTS-1 imagery

The purpose of the investigation described in this paper has been the analysis of large-scale geologic ground patterns in Kansas using ERTS-1 imagery and optical data processing techniques. Optical spatial frequency data provide a repeatable quantitative means of specifying ground pattern characteristics.

Egbert, D.↗

Correlation of Predicted and Observed Optical Properties of Multilayer Thermal Control Coatings

Thermal control coatings on spacecraft will be increasingly important, as spacecraft grow smaller and more compact. New thermal control coatings will be needed to meet the demanding requirements of next generation spacecraft. Computer programs are now available to design optical coatings and one such program was used to design several thermal control coatings consisting of alternating layers of WO3 and SiO2. The coatings were subsequently manufactured with electron beam evaporation and characterized with both optical and thermal techniques. Optical data were collected in both the visible region of the spectrum and the infrared. Predictions of solar absorptance and infrared emittance were successfully correlated to the observed thermal control properties. Functional performance of the coatings was verified in a bench top thermal vacuum chamber.

Jaworske, Donald A.↗

Development of Optical Diagnostic Techniques for Microgravity Materials Processing

Materials processing including crystal growth, either under a gravity environment on ground or a microgravity environment in space, involves complicated phenomena of fluid motions in gas or liquid phases as well as interaction of various species. To obtain important physical insight, it is very necessary to provide gross-field optical diagnostics for monitoring various physical properties. Materials processing inhibits easy access by ordinary instruments and thus characterizing gross-field physical properties is very challenging. Typical properties of importance can be fluid velocity, temperature, and species concentration for fluids, and surface topology and defects for solids. Observing surface grow rate during crystal growth is also important. Material microstructures, i.e., integrity of crystal structures, is strongly influenced by the existence of thermally-induced flow as well as local nucleation of particles during solidification, which may act in many detrimental ways. In both ground-based and microgravity experiments, the nature of product property changes resulting from three-dimensional fluid or particle motions need be characterized. Gross-field diagnostics is thus required to identify their effects on product defects and process deficiencies. The quantitative visualization techniques can also be used for validation of numerical modeling. For optical nonintrusive gross-field diagnostic techniques, two approaches were developed as summer projects. One optical approach allows us to provide information of species concentration and temperature for monitoring in real time. The other approach, that is, the concept which is formulated for detection of surface topography measurement can provide unprecedented spatial resolution during crystal growth.

Cha, Soyoung Stephen↗

Cophasing segmented mirrors with large surface errors using physical and geometrical ray-based techniques

Phasing an array with steep slopes and large surface errors, such as in NASA's Precision Segmented Reflector (PSR) Program for submillimeter astrophysics, is difficult using conventional optical techniques because the surface errors on the panels are large as compared with optical wavelengths. This paper extrapolates a procedure proposed by the Keck Observatory whereby physical optical techniques phase the edges of the panels, but with this technique they are phased with respect to a reference surface obtained from a high-quality central panel. A full-surface height-map is thereby obtained by integrating slope measurements, and full-surface phasing can be achieved using the modified and conventional Shack-Hartmann camera.

Manhart, Paul K.↗

A simplified CARS measurement system for rapid determination of temperature and oxygen concentration

A new spectroscopic concept for the rapid determination of temperature and oxygen concentration by CARS (Coherent Anti-Stokes Raman Spectroscopy) was described. The ratio of two spectral regions in the broadband Q-branch spectrum was detected by photomultipliers in a monochromator, which ratio depends on temperature and species concentration. The comparison of the measured data with theory was made using a flat flame burner and an electric furnace, with reasonable results. Various optical techniques for alignment were introduced including a highly efficient, stable dye oscillator. The combination of the spectroscopic concept and the optical techniques will make the CARS measurement system rapid in data processing and simple in optical parts.

Fujii, Shoichi↗

Development of a High-Pressure Gaseous Burner for Calibrating Optical Diagnostic Techniques

In this work-in-progress report, we show the development of a unique high-pressure burner facility (up to 60 atm) that provides steady, reproducible premixed flames with high precision, while having the capability to use multiple fuel/oxidizer combinations. The highpressure facility has four optical access ports for applying different laser diagnostic techniques and will provide a standard reference flame for the development of a spectroscopic database in high-pressure/temperature conditions. Spontaneous Raman scattering (SRS) was the first diagnostic applied, and was used to successfully probe premixed hydrogen-air flames generated in the facility using a novel multi-jet micro-premixed array burner element. The SRS spectral data include contributions from H2, N2, O2, and H2O and were collected over a wide range of equivalence ratios ranging from 0.16 to 4.9 at an initial pressure of 10-atm via a spatially resolved point SRS measurement with a high-performance optical system. Temperatures in fuel-lean to stoichiometric conditions were determined from the ratio of the Stokes to anti-Stokes scattering of the Q-branch of N2, and those in fuel-rich conditions via the rotational temperature of H2. The SRS derived temperatures using both techniques were consistent and indicated that the flame temperature was approximately 500 K below that predicted by adiabatic equilibrium, indicating a large amount of heat-loss at the measurement zone. The integrated vibrational SRS signals show that SRS provides quantitative number density data in high-pressure H2-air flames.

Kojima, Jun↗

Spatial Temporal Image Correlation Spectroscopy (STICS) for Flow Analysis with Application for Blood Flow Mapping

It is important for surgeons to be able to measure blood flow in exposed arterioles during surgery. We report our progress in the development of an optical technique that will measure blood flow in surgically exposed blood vessels and enable previously difficult measurements. By monitoring optical fluctuations, the optical technique, based on Spatial Temporal Image Correlation (STICS), will directly measure the velocity of micron-scale particles--such as red blood cells. It will complement existing technology and provide qualitative measurements that were not previously possible. It relies on the concept that blood, when viewed on a small enough scale, is an inhomogeneous substance. Individual blood cells passing between a near-infrared light source and a detector will cause fluctuations in the transmitted optical signal. The speed, direction, and flow pattern of blood cells can be determined from these optical fluctuations. We present a series of computer simulations and experiments on phantom and animal systems to test this technique's ability to map complex flow patterns.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optical Measurement Techniques for Rocket Engine Testing and Component Applications: Digital Image Correlation and Dynamic Photogrammetry

NASA Marshall Space Flight Center (MSFC) has been advancing dynamic optical measurement systems, primarily Digital Image Correlation, for extreme environment rocket engine test applications. The Digital Image Correlation (DIC) technology is used to track local and full field deformations, displacement vectors and local and global strain measurements. This technology has been evaluated at MSFC through lab testing to full scale hotfire engine testing of the J-2X Upper Stage engine at Stennis Space Center. It has been shown to provide reliable measurement data and has replaced many traditional measurement techniques for NASA applications. NASA and AMRDEC have recently signed agreements for NASA to train and transition the technology to applications for missile and helicopter testing. This presentation will provide an overview and progression of the technology, various testing applications at NASA MSFC, overview of Army-NASA test collaborations and application lessons learned about Digital Image Correlation.

Gradl, Paul↗