Search NASA⌕ Search

SEARCH · Search NASA

Results for “parameter optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Power Saving Optimization for Linear Collider Interaction Region Parameters

Optimization of Interaction Region parameters of a TeV energy scale linear collider has to take into account constraints defined by phenomena such as beam-beam focusing forces, beamstrahlung radiation, and hour-glass effect. With those constraints, achieving a desired luminosity of about 2E34 would require use of e{sup +}e{sup -} beams with about 10 MW average power. Application of the 'travelling focus' regime may allow the required beam power to be reduced by at least a factor of two, helping reduce the cost of the collider, while keeping the beamstrahlung energy loss reasonably low. The technique is illustrated for the 500 GeV CM parameters of the International Linear Collider. This technique may also in principle allow recycling the e{sup +}e{sup -} beams and/or recuperation of their energy.

43 PARTICLE ACCELERATORS↗

Optimization of plasma parameters with magnetic filter field and pressure to maximize H{sup −} ion density in a negative hydrogen ion source

Transverse magnetic filter field as well as operating pressure is considered to be an important control knob to enhance negative hydrogen ion production via plasma parameter optimization in volume-produced negative hydrogen ion sources. Stronger filter field to reduce electron temperature sufficiently in the extraction region is favorable, but generally known to be limited by electron density drop near the extraction region. In this study, unexpected electron density increase instead of density drop is observed in front of the extraction region when the applied transverse filter field increases monotonically toward the extraction aperture. Measurements of plasma parameters with a movable Langmuir probe indicate that the increased electron density may be caused by low energy electron accumulation in the filter region decreasing perpendicular diffusion coefficients across the increasing filter field. Negative hydrogen ion populations are estimated from the measured profiles of electron temperatures and densities and confirmed to be consistent with laser photo-detachment measurements of the H{sup −} populations for various filter field strengths and pressures. Enhanced H{sup −} population near the extraction region due to the increased low energy electrons in the filter region may be utilized to increase negative hydrogen beam currents by moving the extraction position accordingly. This new finding can be used to design efficient H{sup −} sources with an optimal filtering system by maximizing high energy electron filtering while keeping low energy electrons available in the extraction region.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Analytic Framework for Optimal Milling Parameter Selection

The selection of optimal parameters is an important step in machining process definition. This paper presents a decision analytic framework for completing this task. The approach is demonstrated for titanium milling. An influence diagram showing the decision situation, the corresponding uncertainties, and the value is presented. The optimization objective is the selection of machining parameters that minimize cost while considering uncertainty in tool life and stability. The uncertainties are characterized using a probability distribution taking into account all available information. The cost associated with tool failure and unstable cutting conditions is incorporated in the cost formulation. A process probability tree showing the uncertainties and the corresponding costs is constructed. The optimization results show a 90% reduction in machining cost as compared to tool manufacturer-recommended parameters. The proposed framework is normative and robust and can be applied for optimizing process parameters in conventional (such as milling and turning) and non-conventional (such as electric discharge machining, electro-chemical machining) processes. A discussion section regarding inference, experimental design, and risk aversion is included.

Karandikar, Jaydeep↗

Uncertainty quantification and optimization of precipitating hydrometeor parameters for winter precipitation in a cloud microphysics scheme

The precipitating hydrometeor parameters used in cloud microphysics schemes carry inherent uncertainties. The quantification of these uncertainties, together with parameter optimization, can significantly improve precipitation forecasts. This study investigates the effects of 13 parameters in the Weather Research and Forecasting (WRF) Double-Moment 6-class (WDM6) microphysics scheme, which define the hydrometeor characteristics such as fall velocity–diameter and mass–diameter relationships, as well as the shape parameter of the drop size distribution for precipitating particles such as rain, snow, and graupel on simulated winter precipitation. A comparison between the model's pre-defined parameters and observations from the International Collaborative Experiments for the PyeongChang 2018 Olympic and Paralympic winter games (ICE-POP 2018) field campaign reveals that the fall velocity–diameter relationship for rain, the mass–diameter relationships for snow and graupel, and the shape parameters for all precipitating particles in the WDM6 scheme deviate from the median values observed by the two-dimensional video disdrometer (2DVD). To quantify parameter sensitivities, a perturbed parameter ensemble (PPE) of 256 simulations was conducted within parameter ranges constrained by 2DVD observations for three winter precipitation cases. Bayesian optimization was then applied to identify parameter sets that minimized the root mean square error (RMSE) for each case, achieving reductions of up to 30.2 %. These results demonstrate that ensemble-based uncertainty quantification and parameter optimization can help identify key parameters and provide a pathway to improving precipitation simulation performance. In addition, measurement sites can be strategically selected based on regions that show high sensitivity to variations in hydrometeor characteristic parameters.

Bayesian optimization↗

Computational and human observer image quality evaluation of low dose, knowledge-based CT iterative reconstruction

Purpose: Aims in this study are to (1) develop a computational model observer which reliably tracks the detectability of human observers in low dose computed tomography (CT) images reconstructed with knowledge-based iterative reconstruction (IMR™, Philips Healthcare) and filtered back projection (FBP) across a range of independent variables, (2) use the model to evaluate detectability trends across reconstructions and make predictions of human observer detectability, and (3) perform human observer studies based on model predictions to demonstrate applications of the model in CT imaging. Methods: Detectability (d′) was evaluated in phantom studies across a range of conditions. Images were generated using a numerical CT simulator. Trained observers performed 4-alternative forced choice (4-AFC) experiments across dose (1.3, 2.7, 4.0 mGy), pin size (4, 6, 8 mm), contrast (0.3%, 0.5%, 1.0%), and reconstruction (FBP, IMR), at fixed display window. A five-channel Laguerre–Gauss channelized Hotelling observer (CHO) was developed with internal noise added to the decision variable and/or to channel outputs, creating six different internal noise models. Semianalytic internal noise computation was tested against Monte Carlo and used to accelerate internal noise parameter optimization. Model parameters were estimated from all experiments at once using maximum likelihood on the probability correct, P{sub C}. Akaike information criterion (AIC) was used to compare models of different orders. The best model was selected according to AIC and used to predict detectability in blended FBP-IMR images, analyze trends in IMR detectability improvements, and predict dose savings with IMR. Predicted dose savings were compared against 4-AFC study results using physical CT phantom images. Results: Detection in IMR was greater than FBP in all tested conditions. The CHO with internal noise proportional to channel output standard deviations, Model-k4, showed the best trade-off between fit and model complexity according to AIC{sub c}. With parameters fixed, the model reasonably predicted detectability of human observers in blended FBP-IMR images. Semianalytic internal noise computation gave results equivalent to Monte Carlo, greatly speeding parameter estimation. Using Model-k4, the authors found an average detectability improvement of 2.7 ± 0.4 times that of FBP. IMR showed greater improvements in detectability with larger signals and relatively consistent improvements across signal contrast and x-ray dose. In the phantom tested, Model-k4 predicted an 82% dose reduction compared to FBP, verified with physical CT scans at 80% reduced dose. Conclusions: IMR improves detectability over FBP and may enable significant dose reductions. A channelized Hotelling observer with internal noise proportional to channel output standard deviation agreed well with human observers across a wide range of variables, even across reconstructions with drastically different image characteristics. Utility of the model observer was demonstrated by predicting the effect of image processing (blending), analyzing detectability improvements with IMR across dose, size, and contrast, and in guiding real CT scan dose reduction experiments. Such a model observer can be applied in optimizing parameters in advanced iterative reconstruction algorithms as well as guiding dose reduction protocols in physical CT experiments.

60 APPLIED LIFE SCIENCES↗

Parametric study of critical constraints for a canard configured medium range transport using conceptual design optimization

Constrained parameter optimization was used to perform optimal conceptual design of both canard and conventional configurations of a medium range transport. A number of design constants and design constraints were systematically varied to compare the sensitivities of canard and conventional configurations to a variety of technology assumptions. Main landing gear location and horizontal stabilizer high-lift performance were identified as critical design parameters for a statically stable, subsonic canard transport.

Arbuckle, P. D.↗

SU-D-12A-06: A Comprehensive Parameter Analysis for Low Dose Cone-Beam CT Reconstruction

Purpose: There is always a parameter in compressive sensing based iterative reconstruction (IR) methods low dose cone-beam CT (CBCT), which controls the weight of regularization relative to data fidelity. A clear understanding of the relationship between image quality and parameter values is important. The purpose of this study is to investigate this subject based on experimental data and a representative advanced IR algorithm using Tight-frame (TF) regularization. Methods: Three data sets of a Catphan phantom acquired at low, regular and high dose levels are used. For each tests, 90 projections covering a 200-degree scan range are used for reconstruction. Three different regions-of-interest (ROIs) of different contrasts are used to calculate contrast-to-noise ratios (CNR) for contrast evaluation. A single point structure is used to measure modulation transfer function (MTF) for spatial-resolution evaluation. Finally, we analyze CNRs and MTFs to study the relationship between image quality and parameter selections. Results: It was found that: 1) there is no universal optimal parameter. The optimal parameter value depends on specific task and dose level. 2) There is a clear trade-off between CNR and resolution. The parameter for the best CNR is always smaller than that for the best resolution. 3) Optimal parameters are also dose-specific. Data acquired under a high dose protocol require less regularization, yielding smaller optimal parameter values. 4) Comparing with conventional FDK images, TF-based CBCT images are better under a certain optimally selected parameters. The advantages are more obvious for low dose data. Conclusion: We have investigated the relationship between image quality and parameter values in the TF-based IR algorithm. Preliminary results indicate optimal parameters are specific to both the task types and dose levels, providing guidance for selecting parameters in advanced IR algorithms. This work is supported in part by NIH (1R01CA154747-01)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗