LIvermore SEM image Tools

Scanning Electron Microscopy (SEM) images provide a variety of structural and morphological information for the characterization of the nanomaterials. This code offers automatic recognition and quantitative analysis of SEM images in a high-throughput manner using computer vision and machine learning techniques. The main function of this application is to extract particle size and morphology information of overlapping nanoparticles and core-shell nanostructures in a user friendly interface. The code is written in C++ with QT environment, and has been tested on MacOSX.

KIM, HYOJIN↗

Deep electric field predictions by drift-reduced Braginskii theory with plasma-neutral interactions based upon experimental images of boundary turbulence

We present 2-dimensional turbulent electric field calculations via physics-informed deep learning consistent with (i) drift-reduced Braginskii theory under the framework of an axisymmetric fusion plasma with purely toroidal field and (ii) experimental estimates of the fluctuating electron density and temperature obtained from analysis of gas puff imaging of a discharge on the Alcator C-Mod tokamak. The inclusion of effects from the locally puffed atomic helium on particle and energy sources within the reduced plasma turbulence model are found to strengthen correlations between the electric field and electron pressure. The neutrals are also directly associated with an observed broadening in the distribution of turbulent field amplitudes and increased E×B shearing rates.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental Measurements of the Wake of a Sphere at Subcritical Reynolds Numbers

This work experimentally investigated the flow phenomena and vortex structures in the wake of a sphere located in a water loop at Reynolds numbers of Re = 850, 1,250, and 1,700. Velocity fields in the wake region were obtained by applying the time-resolved stereoscopic particle image velocimetry (TR-SPIV) technique. From the acquired TR-SPIV velocity vector fields, the statistical values of mean and fluctuating velocities were computed. Spectral analysis, two-point velocity–velocity cross-correlation, proper orthogonal decomposition (POD) and vortex identification analyses were also performed. The velocity fields show a recirculation region that decreases in length with an increase of Reynolds numbers. The power spectra from the spectral analysis had peaks corresponding to a Strouhal number of St = 0.2, which is a value commonly found in the literature studies of flow over a sphere. The two-point cross-correlation analysis revealed elliptical structures in the wake, with estimated integral length scales ranging between 12% and 63% of the sphere diameter. The POD analysis revealed the statistically dominant flow structures that captured the most flow kinetic energy. It is seen that the flow kinetic energy captured in the smaller scale flow structures increased as Reynolds number increased. The POD modes contained smaller structure as the Reynolds number increased and as mode order increased. In addition, spectral analysis performed on the POD temporal coefficients revealed peaks corresponding to St = 0.2, similar to the spectral analysis on the fluctuating velocity. The ability of POD to produce low-order reconstructions of the flow was also utilized to facilitate vortex identification analysis, which identified average vortex sizes of 0.41D for Re1, 0.33D for Re2, and 0.32D for Re3.

Engineering↗

Nanometer Scale Imaging to Develop Quantitative Descriptors of Bipolar Membrane Junction Structure

Swings in pH can be achieved by electrically polarizing a bipolar membrane (BPM) to drive water dissociation at the BPM junction for electrochemical conversion and separation processes. BPM junction design is critical to tailor performance for specific applications; however, characterization techniques capable of resolving the nanometer scale physical structure of the junction are limited. We present sample preparation, imaging, and analysis workflows that are adaptable to a variety of BPM junction architectures. Atomic force microscopy produces BPM junction images with nanometer scale lateral resolution for samples with and without a graphene oxide water dissociation catalyst in the junction. Subsequent image segmentation and analysis quantify line edge roughness and catalyst layer thickness as descriptors of junction structure. Comparison of pre- and post-electrodialysis junctions suggests electric field-induced alignment of catalyst particles during electrodialysis. This characterization workflow can inform manufacturing protocols, computational modeling, and failure mode analysis for next-generation BPMs.

97 MATHEMATICS AND COMPUTING↗

Operando X-ray imaging reveals size-dependent evolution of cobalt oxide thermochemical material during thermal redox cycles

Multivalent metal oxides are promising thermochemical materials (TCMs) for energy storage and conversion owing to their high energy density, air compatibility, and high-temperature stability. Co 3 O 4 serves as a model system for examining particle-size- and structure-dependent redox behavior. While particle size and porosity are known to affect performance, their interplay and the kinetics of pore formation during cycling remain unclear. Here we show the chemical and 3D morphological evolution of Co 3 O 4 micro- and nanoparticles during redox cycles at 800–900 °C using thermal analysis, in-situ synchrotron transmission X-ray microscopy (TXM), and scanning electron microscopy. Thermal analysis shows that nanoparticles re-oxidize more rapidly than microparticles at 800 °C. In-situ nanotomography and chemical imaging reveals that nanoparticles undergo redox conversion without forming internal pores, whereas microparticles develop isolated porosity during reduction. These pores persist through re-oxidation, correlating to a lower conversion rate in subsequent cycles. Our results demonstrate distinct degradation kinetics in Co 3 O 4 micro- and nanoparticles, underscoring the critical role of particle size and porosity in redox performance and informing strategies to enhance the long-term efficiency of metal oxide TCMs.

25 ENERGY STORAGE↗

Introducing the Video In Situ Snowfall Sensor (VISSS)

The open-source Video In Situ Snowfall Sensor (VISSS) is introduced as a novel instrument for the characterization of particle shape and size in snowfall. The VISSS consists of two cameras with LED backlights and telecentric lenses that allow accurate sizing and combine a large observation volume with relatively high pixel resolution and a design that limits wind disturbance. VISSS data products include various particle properties such as maximum extent, cross-sectional area, perimeter, complexity, and sedimentation velocity. Initial analysis shows that the VISSS provides robust statistics based on up to 10 000 unique particle observations per minute. Comparison of the VISSS with the collocated PIP (Precipitation Imaging Package) and Parsivel instruments at Hyytiälä, Finland, shows excellent agreement with the Parsivel but reveals some differences for the PIP that are likely related to PIP data processing and limitations of the PIP with respect to observing smaller particles. The open-source nature of the VISSS hardware plans, data acquisition software, and data processing libraries invites the community to contribute to the development of the instrument, which has many potential applications in atmospheric science and beyond.

54 ENVIRONMENTAL SCIENCES↗

A prototype scintillator real‐time beam monitor for ultra‐high dose rate radiotherapy

Background: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. Purpose: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. Methods: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100–1000 Hz for pulsed electrons and 10–20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams ( 86 Kr +26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. Results: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. Furthermore, the HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35–40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. Conclusions: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.

2D beam imaging↗

Uncertainty analysis of PIV measurements in bubbly flows considering sampling and bubble effects with ray optics modeling

In this report, a modeling-based approach is developed to investigate the external sources of uncertainty in particle image velocimetry (PIV) measurements for two-phase bubbly flows. Primarily relied on ray optics modeling, this study focuses on the uncertainty in PIV measurements due to bubble-induced light distortion. In addition, the uncertainty due to sampling is also considered through synthetic PIV images generated from Monte Carlo sampling. Based on a PIV-planar laser induced florescence (PLIF) measurement system, three case studies are performed and discussed, considering respectively the sampling effect, bubble effect, and the combination of these two effects. These case studies confirm the validity of the ray optics modeling in obtaining accurate particle images through a benchmark test. Furthermore, it is also found that the bubble effect could significantly influence the particle images. On the other hand, the result of the case study with synthetic PIV images indicates that the bubble effect on particle images can be minimized by removing “outliers” in the obtained velocity vector field through a multi-pass post-processing procedure. However, the uncertainty of the velocity measurements will still increase.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Systematic Source Determination and X-Ray Radiography Detection of Nonuniformities on High-Density Carbon Ablators

Recent deuterium-tritium (D-T)–layered implosion experiments at the National Ignition Facility have achieved a burning plasma and >1-MJ neutron yield. A series of repeat experiments have shown that the degree of performance is very likely dependent on capsule quality, including the quantity of what are collectively termed “high- Z particles.” These particles are detected on a custom-built radiography system, known as the Sagometer, during the final target qualification process. The term particles is misleading, as the source of these nonuniformities in the capsule images is uncertain; the term detection will be used instead. An increased number of D-T targets have been rejected at the final stages of production due to Sagometer detections. Late detections are deleterious in terms of loss of production parts, effort, and overall operating efficiency. In response, we undertook an effort to determine the origin of these detections and to ultimately mitigate target losses caused by them. Through careful testing and analysis, we have determined neither insufficient production cleanliness nor hohlraum shedding is responsible for the detections on the capsule. Here, we determined that the detections are inherent to the capsule and have made efforts to use the Zeiss Xradia to identify them earlier in the production process. While testing revealed the Xradia is not currently sufficient for identifying such particles using radiography images, we continue to look to other forms of metrology to down select the capsules early in the process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatiotemporal Plasma-Particle Characterization of Dry Aerosols Using Nanosecond, Femtosecond, and Filament Laser-Produced Plasmas

The ability to rapidly characterize dry aerosols in air using laser-induced breakdown spectroscopy (LIBS) with femtosecond laser pulses promises advancement towards real-time atmospheric sampling and standoff capabilities. Of particular interest is the ability to apply LIBS in the context of low-particle loaded environments where discrete particle interactions must be observed within the sampling volume of the laser-produced plasma (LPP). In this study, dry nanoparticles in suspension are generated from a standard solution and sampled in air using Q-switched nanosecond (ns-) pulses, short-focus (SF) femtosecond (fs-) pulses, and filaments. Short time-gated plasma images are captured to observe spatially and temporally varying discrete plasma-particle interactions, which is shown to influence early air breakdown behavior and subsequent plasma evolution. Along with images, photo-multiplier tube (PMT) measurements are conducted where strong spatiotemporal dependencies are exhibited by the collected emission signal on particle proximity and plasma expansion behavior. Finally, conditional analysis is performed on LIBS measurements to determine associated sampling probabilities and filter out spectra with poor or absent emission peaks with an adaptive threshold algorithm.

42 ENGINEERING↗

Towards Autonomous Experiments by Connecting High Performance Microscopy with High Performance Computing

The digitization of controls, data, and analysis in microscopy is bringing the idea of autonomous microscopes closer to reality than ever before. Automated transmission electron microscopy (TEM) is already fairly routine for some experiments the only require simple repetitive tasks such as imaging biological macromolecules for single particle cryoEM [1], tilt series for electron tomography [2], and movies for crystallography [3]. The vast majority of TEM experiments are conducted completely by human operators who choose the regions of interest, optimize experimental parameters, and make decisions about data quality visually during an experiment. The field is still a long way from having completely autonomous TEMs that can adapt to sample difficulties and tune experimental parameters based on data quality and desired experimental outcomes. Part of the issue is the lack of capability for feeding information learned from on-line, live data analysis back into the on-going experiment [4]. Furthermore, this presentation will discuss current capabilities for large scale data reduction and analysis using high performance computing (i.e. supercomputing) and progress towards developing a true feed-back loop that places data analysis and theory in the experimental loop.

97 MATHEMATICS AND COMPUTING↗

Electrode Mesoscale as a Collection of Particles: Coupled Electrochemical and Mechanical Analysis of NMC Cathodes

Battery electrodes are composed of polydisperse particles and a porous, composite binder domain. These materials are arranged into a complex mesostructure whose morphology impacts both electrochemical performance and mechanical response. We present image-based, particle-resolved, mesoscale finite element model simulations of coupled electrochemical-mechanical performance on a representative NMC electrode domain. Beyond predicting macroscale quantities such as half-cell voltage and evolving electrical conductivity, studying behaviors on a per-particle and per-surface basis enables performance and material design insights previously unachievable. Voltage losses are primarily attributable to a complex interplay between interfacial charge transfer kinetics, lithium diffusion, and, locally, electrical conductivity. Mesoscale heterogeneities arise from particle polydispersity and lead to material underutilization at high current densities. Particle-particle contacts, however, reduce heterogeneities by enabling lithium diffusion between connected particle groups. While the porous composite binder domain (CBD) may have slower ionic transport and less available area for electrochemical reactions, its high electrical conductivity makes it the preferred reaction site late in electrode discharge. Mesoscale results are favorably compared to both experimental data and macrohomogeneous models. This work enables improvements in materials design by providing a tool for optimization of particle sizes, CBD morphology, and manufacturing conditions.

42 ENGINEERING↗

Multi-Tiered Estimation for Correlation Spectroscopy in 3D (MTECS3D) v0.1

This innovative software estimates rotational diffusion coefficients of particles from X-ray photon correlation spectroscopy (XPCS) data of monodispersed particle systems. It is the first method capable of extracting rotational diffusion information from three-dimensional particle systems using XPCS. Using the angular-temporal cross-correlation of the XPCS images, this software is able to estimate the rotational diffusion coefficients with only a few percent relative errors while requiring minimal prior knowledge of particle structures. This software enhances XPCS analysis capabilities, allowing researchers to study translational and rotational Brownian dynamics of particles in suspension across various temporal and spatial scales.

Hu, Zixi↗

Probing the Role of Multi-scale Heterogeneity in Graphite Electrodes for Extreme Fast Charging

Electrode-scale heterogeneity can combine with complex electrochemical interactions to impede lithium-ion battery performance, particularly during fast charging. This research investigates the influence of electrode heterogeneity at different scales on the lithium-ion battery electrochemical performance under operational extremes. We employ image-based mesoscale simulation in conjunction with a three-dimensional electrochemical model to predict performance variability in 14 graphite electrode X-ray computed tomography data sets. Our analysis reveals that the tortuous anisotropy stemming from the variable particle morphology has a dominating influence on the overall cell performance. Cells with platelet morphology achieve lower capacity, higher heat generation rates, and severe plating under extreme fast charge conditions. On the contrary, the heterogeneity due to the active material clustering alone has minimal impact. Our work suggests that manufacturing electrodes with more homogeneous and isotropic particle morphology will improve electrochemical performance and improve safety, enabling electromobility.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improving microstructures segmentation via pretraining with synthetic data

Image analysis of material microstructures through microscopy is an integral capability in the field of materials science. The topological and chemical information obtained through microscopy allow us to draw vital connections between material microstructures, properties, and processing. While scanning electron microscopy (SEM) is able to yield a considerable wealth of information interpretable by the intuition of experts, there has been considerable interest in using machine learning, convolutional neural networks (CNNs) in particular, for such image analysis task. Training CNNs for an image analysis task requires a large annotated dataset. However, in many materials science applications, obtaining a large annotated dataset is cost and labor intensive. In this work, we study the use of synthetic data to enlarge the available annotated experimental data of uranium oxide. We utilize a modified Potts model to simulate uranium oxide particles with morphologies similar to those observed experimentally. We then leverage an image-to-image translation model to synthesize the simulated particles as if they are acquired with SEM. Through this process, we obtain pairs of particle images and their corresponding SEM representations, which corresponds to pairs of annotations and images. Unlike previous works, we leverage synthetic data for pretraining a CNN model prior, and finetune that model further with experimental data. We experimentally demonstrate that using synthetic data as incremental learning process benefits the overall performance compared to training a model on combined synthetic and experimental data.

36 MATERIALS SCIENCE↗

Classification of Cloud Particle Imagery from Aircraft Platforms Using Convolutional Neural Networks

Abstract A vast amount of ice crystal imagery exists from a variety of field campaign initiatives that can be utilized for cloud microphysical research. Here, nine convolutional neural networks are used to classify particles into nine regimes on over 10 million images from the Cloud Particle Imager probe, including liquid and frozen states and particles with evidence of riming. A transfer learning approach proves that the Visual Geometry Group (VGG-16) network best classifies imagery with respect to multiple performance metrics. Classification accuracies on a validation dataset reach 97% and surpass traditional automated classification. Furthermore, after initial model training and preprocessing, 10 000 images can be classified in approximately 35 s using 20 central processing unit cores and two graphics processing units, which reaches real-time classification capabilities. Statistical analysis of the classified images indicates that a large portion (57%) of the dataset is unusable, meaning the images are too blurry or represent indistinguishable small fragments. In addition, 19% of the dataset is classified as liquid drops. After removal of fragments, blurry images, and cloud drops, 38% of the remaining ice particles are largely intersecting the image border (≥10% cutoff) and therefore are considered unusable because of the inability to properly classify and dimensionalize. After this filtering, an unprecedented database of 1 560 364 images across all campaigns is available for parameter extraction and bulk statistics on specific particle types in a wide variety of storm systems, which can act to improve the current state of microphysical parameterizations.

54 ENVIRONMENTAL SCIENCES↗

Thermal Hysteresis and Ordering Behavior of Magnetic Skyrmion Lattices

The physics of phase transitions in two-dimensional (2D) systems underpins research in diverse fields including statistical mechanics, nanomagnetism, and soft condensed matter. However, many aspects of 2D phase transitions are still not well understood, including the effects of interparticle potential, polydispersity, and particle shape. Magnetic skyrmions are chiral spin-structure quasi-particles that form two-dimensional lattices. Here, in this study, we show, by real-space imaging using in situ cryo-Lorentz transmission electron microscopy coupled with machine learning image analysis, the ordering behavior of Néel skyrmion lattices in van der Waals Fe 3 GeTe 2 . We demonstrate a distinct change in the skyrmion size distribution during field-cooling, which leads to a loss of lattice order and an evolution of the skyrmion liquid phase. Remarkably, the lattice order is restored during field heating and demonstrates a thermal hysteresis. This behavior is explained by the skyrmion energy landscape and demonstrates the potential to control the lattice order in 2D phase transitions.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A proximity‐based image‐processing algorithm for colloid assignment in segmented multiphase flow datasets

Summary Colloidal transport and deposition are of both environmental and engineering importance. Easier access to x‐ray microtomography (XMT) coupled with improved imaging resolution has made XMT a unique and viable tool for visualizing and quantifying these processes. Currently, there is scant information in the literature addressing colloid segmentation and analysis in saturated and unsaturated porous media, in particular related to spatial partitioning of colloids. To support this need, an approach to assign segmented colloidal particles and aggregates to different partitioning classes based on their proximity to different phases is presented here. The method uses different markers for each attachment site (e.g. wetting‐nonwetting phase interfaces). An example XMT dataset from a drainage experiment is used to demonstrate the efficacy of the image processing algorithms. Flow conditions, and fluid and colloid properties, can thus be compared to the behaviour of colloids within the porous medium. This algorithm can help elucidate colloidal deposition mechanisms and the importance of different attachment sites, explore the importance of fluid properties, as well as the arrangement and shape of the colloids.