Search NASA⌕ Search

SEARCH · Search NASA

Results for “peak estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Solar activity geomagnetic field and terrestrial weather

Spectral analysis is used as an independent test of the reported association between interplanetary-magnetic-field structure and terrestrial weather. Spectra of the Ap geomagnetic activity index and the vorticity area index for the years from 1964 to 1970 are examined for common features that may be associated with solar-related phenomena, specifically for peaks in the power spectra of both time series with periods near 27.1 days. The spectra are compared in three ways, and the largest peak with the smallest probability estimate is found to occur at a period of 27.49 days. This result is considered to be statistically significant at the 98% level. It is concluded that the period derived from the Ap spectrum is related to solar rotation and that the analysis provides supporting evidence for a connection between the vorticity area index and solar activity.

Knight, J. W.↗

An apparent 'even-odd' cycle distribution in Mt. Wilson 'numbers of spots' data

Mt. Wilson 'numbers of spots' data (Howard et al., 1984) appear to be distributed according to 'even-odd' cycle numbering. Linear fits of annual 'numbers of spots' versus annual sunspot number for even- and odd-numbered cycles have slopes which are statistically different at the 5 percent level of significance. The existence of an 'even-odd' split in Mt. Wilson 'numbers of spots' data may be due either to a real difference in even- and odd-numbered cycles on the sun or to a difference in weather at Mt. Wilson during even- and odd-numbered cycles, or both. For cycle 22, an even-numbered cycle, the peak 'numbers of spots' is estimated to be near 2600.

Wilson, Robert M.↗

A model of the formation of high-salinity shelf water on polar continental shelves

This study presents a model of the flow and salinity fields forced by sea-surface salinity flux and wind stress curl and examines the processes that create High-Salinity Shelf Water (HSSW). To investigate the relative effects of wind stress and buoyancy forcing in HSSW production, the polynya freezing rate in the model is varied from 0.0 to 0.30 m/d, and the Ekman pumping derived from the wind stress curl is varied independently from 0.0 to 1.8 x 10 exp 6 m/s. The Ekman pumping was found to control the magnitude of the circulation, while the polynya freezing rate controlled the extent of salinization in the shelf water. The flux of HSSW increases linearly with increasing Ekman pumping above 0.3 x 10 exp -6 m/s. The modeled flux of HSSW and the flux of derived Botttom Water for the present estimates of the forcings (a peak freezing rate of 0.10 m/d and Ekman pumping of 0.2 x 10 exp -6 m/s) agree with the fluxes inferred from physical and chemical observations in the deep Weddel Sea by oceanographic field programs.

Grumbine, Robert W.↗

Simultaneous in situ Optical Monitoring Techniques during Crystal Growth of ZnSe by Physical Vapor Transport

ZnSe crystals grown in sealed ampoules by the physical vapor transport method were monitored in situ using three techniques, simultaneously. A Michelson interferometer was set-up to observe the growth rate and surface morphological evolution. An interference pattern (interferogram) is formed by the interaction between the reflection of a HeNe laser (632.8 nm wavelength) off the crystal-vapor interface and a reference beam from the same laser. Preliminary results indicate that the rate of growth/thermal-etching can be calculated using analog data acquisition and simple fringe counting techniques. Gross surface features may also be observed using a digital frame grabber and fringe analysis software. The second in situ technique uses optical absorption to determine the partial pressures of the vapor species. The Se2 and Zn vapor species present in the sealed ampoule absorb light at characteristic wavelengths. The optical absorption is determined by monitoring the light intensity difference between the sample and reference beams. The Se2 Partial pressure profile along the length of the ampoule was estimated from the vibronic absorption peaks at 340.5, 350.8, 361.3 and 379.2 nm using the Beer's law constants established in the calibration runs of pure Se. Finally, because the high temperature crystal growth furnace contains windows, in situ visual observation of the growing crystal is also possible. The use of these techniques not only permits in situ investigation of high temperature vapor growth of semiconductors, but also offers the potential for real time feed back on the growing crystal and allows the possibility of actively controlling the growth process.

Su, C.- H.↗

Decomposition of superimposed ground reaction forces into left and right force profiles

The process of collecting ground reaction force data by mounting a forceplate beneath a treadmill belt has the advantage that numerous walking trials can be analyzed without the problem of subjects 'targeting' their footsteps. However, a potential problem is that the measured forces represent a summation of bilateral force profiles during the double support phase of walking. To address this issue, an algorithm is described for decomposing superimposed ground reaction force data into individual left and right profiles. It is based on an examination of the side-to-side oscillations of the measured center of pressure (CoP). Whenever the measured CoP exceeds a certain threshold, it is assumed that the person is being supported by a single limb, and the measured GRF data reflect the forces under that limb. Conversely, when the measured CoP indicates that both feet are on the treadmill, it is assumed that the location of the individual CoP under each foot is given by wL2 and wR2. These quantities reflect the greatest excursion of the measured CoP towards the left and right sides of the forceplate, respectively. With this assumption, individual GRF profiles can be calculated by means of solving two simultaneous equations--one describing the equilibrium of forces in the vertical direction, and one describing the equilibrium of moments about an antero-posterior axis of the forceplate. The algorithm describing this procedure is simple enough to be implemented on a spreadsheet and yields estimates for average force, impulse, peak force and stance time that are typically within 3% of the true values.

Non-NASA Center↗

Viking Afterbody Heating Computations and Comparisons to Flight Data

Computational fluid dynamics predictions of Viking Lander 1 entry vehicle afterbody heating are compared to flight data. The analysis includes a derivation of heat flux from temperature data at two base cover locations, as well as a discussion of available reconstructed entry trajectories. Based on the raw temperature-time history data, convective heat flux is derived to be 0.63-1.10 W/cm2 for the aluminum base cover at the time of thermocouple failure. Peak heat flux at the fiberglass base cover thermocouple is estimated to be 0.54-0.76 W/cm2, occurring 16 seconds after peak stagnation point heat flux. Navier-Stokes computational solutions are obtained with two separate codes using an 8- species Mars gas model in chemical and thermal non-equilibrium. Flowfield solutions using local time-stepping did not result in converged heating at either thermocouple location. A global time-stepping approach improved the computational stability, but steady state heat flux was not reached for either base cover location. Both thermocouple locations lie within a separated flow region of the base cover that is likely unsteady. Heat flux computations averaged over the solution history are generally below the flight data and do not vary smoothly over time for both base cover locations. Possible reasons for the mismatch between flight data and flowfield solutions include underestimated conduction effects and limitations of the computational methods.

Edquist, Karl T.↗

Transient Three-Dimensional Side Load Analysis of a Film Cooled Nozzle

Transient three-dimensional numerical investigations on the side load physics for an engine encompassing a film cooled nozzle extension and a regeneratively cooled thrust chamber, were performed. The objectives of this study are to identify the three-dimensional side load physics and to compute the associated aerodynamic side load using an anchored computational methodology. The computational methodology is based on an unstructured-grid, pressure-based computational fluid dynamics formulation, and a transient inlet history based on an engine system simulation. Ultimately, the computational results will be provided to the nozzle designers for estimating of effect of the peak side load on the nozzle structure. Computations simulating engine startup at ambient pressures corresponding to sea level and three high altitudes were performed. In addition, computations for both engine startup and shutdown transients were also performed for a stub nozzle, operating at sea level. For engine with the full nozzle extension, computational result shows starting up at sea level, the peak side load occurs when the lambda shock steps into the turbine exhaust flow, while the side load caused by the transition from free-shock separation to restricted-shock separation comes at second; and the side loads decreasing rapidly and progressively as the ambient pressure decreases. For the stub nozzle operating at sea level, the computed side loads during both startup and shutdown becomes very small due to the much reduced flow area.

Wang, Ten-See↗

Hydrogen uptake in graphite matrix at high temperature

Tritium management is a critical challenge for the next generation of nuclear reactors, such as Fluoride Salt Cooled High Temperature Reactors (FHRs) and High Temperature Gas-cooled Reactors (HTGRs), due to the higher production rate (up to 10,000 times) than conventional Light Water Reactors (LWRs). Graphitic materials employed as moderator, reflector, and fuel pebbles offer a potential pathway for tritium recovery by serving as a sink for tritium. Prediction of uptake capacity under reactor relevant conditions remains a challenge due to a lack of low partial pressure data and significant inter-grade variability of graphite. This study addresses these gaps by providing a comprehensive characterization of hydrogen (as a tritium surrogate) uptake and release behavior in the A3-3 graphite matrix (GM) used in fuel pebbles. Uptake measurements are performed at reactor relevant temperatures of 600- 800 °C, 1-200 Torr hydrogen pressure, and 15-120 min equilibration time, followed by thermal desorption spectroscopy up to 1100 °C. Uptake experiments at different equilibration times demonstrate the role of kinetics in hydrogen uptake, which can be modeled as a diffusion-with-trapping process. In the thermodynamics limit, the Sips adsorption model is shown to capture the uptake in A3-3 GM well. Our campaign provides a set of new results for hydrogen uptake in A3-3, including limiting uptake capacity at 600 °C, apparent diffusion coefficient at 600 °C, and the first estimates of the FHR/HTGR relevant (600 °C, 20 Pa partial pressure) equilibrium uptake capacity and time to saturation. Desorption data highlights a new site for hydrogen uptake, not observed in nuclear graphite, which we attribute to the non-graphitized binder. Using the Kissinger method, we estimate activation energy for release from the desorption peaks, confirming the activation energy for release from the basal planes and providing the first estimate for the activation energy of release from the binder.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Updating of ADAPT predictions of sunspot activity

An eigenvector analysis procedure was used to analyze and develop algorithms for predicting sunspot numbers. The predictors in these algorithms consist of sunspot numbers from the preceding two solar cycles and magnetic index data from the preceding cycle. Predictions are presented for cycles 21 and 22. The sunspot activity for cycle 21 is predicted to remain below 100 until early 1980 when it will rapidly reach a peak of approximately 120. The two sigma accuracy on these estimates is approximately 20 sunspot numbers in the region of the peak and 10 sunspot numbers early and late in the cycle. Algorithms were also developed for predicting the period of future sunspot cycles using the same predictor vector.

Hunter, H. C.↗

Viking Afterbody Heating Computations and Comparisons to Flight Data

Computational fluid dynamics predictions of Viking Lander 1 entry vehicle afterbody heating are compared to flight data. The analysis includes a derivation of heat flux from temperature data at two base cover locations, as well as a discussion of available reconstructed entry trajectories. Based on the raw temperature-time history data, convective heat flux is derived to be 0.63-1.10 W/sq cm for the aluminum base cover at the time of thermocouple failure. Peak heat flux at the fiberglass base cover thermocouple is estimated to be 0.54-0.76 W/sq cm, occurring 16 seconds after peak stagnation point heat flux. Navier-Stokes computational solutions are obtained with two separate codes using an 8-species Mars gas model in chemical and thermal non-equilibrium. Flowfield solutions using local time-stepping did not result in converged heating at either thermocouple location. A global time-stepping approach improved the computational stability, but steady state heat flux was not reached for either base cover location. Both thermocouple locations lie within a separated flow region of the base cover that is likely unsteady. Heat flux computations averaged over the solution history are generally below the flight data and do not vary smoothly over time for both base cover locations. Possible reasons for the mismatch between flight data and flowfield solutions include underestimated conduction effects and limitations of the computational methods.

Edquist, Karl T.↗

Estimation of Smoothing Error in SBUV Profile and Total Ozone Retrieval

Data from the Nimbus-4, Nimbus-7 Solar Backscatter Ultra Violet (SBUV) and seven of the NOAA series of SBUV/2 instruments spanning 41 years are being reprocessed using V8.6 algorithm. The data are scheduled to be released by the end of August 2011. An important focus of the new algorithm is to estimate various sources of errors in the SBUV profiles and total ozone retrievals. We discuss here the smoothing errors that describe the components of the profile variability that the SBUV observing system can not measure. The SBUV(/2) instruments have a vertical resolution of 5 km in the middle stratosphere, decreasing to 8 to 10 km below the ozone peak and above 0.5 hPa. To estimate the smoothing effect of the SBUV algorithm, the actual statistics of the fine vertical structure of ozone profiles must be known. The covariance matrix of the ensemble of measured ozone profiles with the high vertical resolution would be a formal representation of the actual ozone variability. We merged the MLS (version 3) and sonde ozone profiles to calculate the covariance matrix, which in general case, for single profile retrieval, might be a function of the latitude and month. Using the averaging kernels of the SBUV(/2) measurements and calculated total covariance matrix one can estimate the smoothing errors for the SBUV ozone profiles. A method to estimate the smoothing effect of the SBUV algorithm is described and the covariance matrixes and averaging kernels are provided along with the SBUV(/2) ozone profiles. The magnitude of the smoothing error varies with altitude, latitude, season and solar zenith angle. The analysis of the smoothing errors, based on the SBUV(/2) monthly zonal mean time series, shows that the largest smoothing errors were detected in the troposphere and might be as large as 15-20% and rapidly decrease with the altitude. In the stratosphere above 40 hPa the smoothing errors are less than 5% and between 10 and 1 hPa the smoothing errors are on the order of 1%. We validate our estimated smoothing errors by comparing the SBUV ozone profiles with other ozone profiling sensors.

Kramarova, N. A.↗

Building application of solar energy. Study no. 4: Scenarios for the utilization of solar energy in southern California buildings, change 1

Plausible future market scenarios for solar heating and cooling systems into buildings in the area served by the Southern California Edison Company. A range of plausible estimates for the number of solar systems which might be installed and the electrical energy which might be displaced by energy from these systems are provided. The effect on peak electrical load was not explicitly calculated but preliminary conclusions concerning peak load can be inferred from the estimates presented. Two markets are investigated: the single family market and the large power commercial market.

Davis, E. S.↗

Integrated Active Fire Retrievals and Biomass Burning Emissions Using Complementary Near-Coincident Ground, Airborne and Spaceborne Sensor Data

Ground, airborne and spaceborne data were collected for a 450 ha prescribed fire implemented on 18 October 2011 at the Henry W. Coe State Park in California. The integration of various data elements allowed near coincident active fire retrievals to be estimated. The Autonomous Modular Sensor-Wildfire (AMS) airborne multispectral imaging system was used as a bridge between ground and spaceborne data sets providing high quality reference information to support satellite fire retrieval error analyses and fire emissions estimates. We found excellent agreement between peak fire radiant heat flux data (less than 1% error) derived from near-coincident ground radiometers and AMS. Both MODIS and GOES imager active fire products were negatively influenced by the presence of thick smoke, which was misclassified as cloud by their algorithms, leading to the omission of fire pixels beneath the smoke, and resulting in the underestimation of their retrieved fire radiative power (FRP) values for the burn plot, compared to the reference airborne data. Agreement between airborne and spaceborne FRP data improved significantly after correction for omission errors and atmospheric attenuation, resulting in as low as 5 difference between AquaMODIS and AMS. Use of in situ fuel and fire energy estimates in combination with a collection of AMS, MODIS, and GOES FRP retrievals provided a fuel consumption factor of 0.261 kg per MJ, total energy release of 14.5 x 10(exp 6) MJ, and total fuel consumption of 3.8 x 10(exp 6) kg. Fire emissions were calculated using two separate techniques, resulting in as low as 15 difference for various species

airborne scanner↗

An optical study of the faint end of the stellar luminosity function

We implement a new method by which to study the faint end of the field star luminosity function. The method relies on deep, multicolor photometry of fields projected against highly obscured, nearby molecular clouds. The clouds act as nearby opaque screens and delimit a well-defined survey volume which is in principle free of the problem of distinguishing nearby, intrinsically faint dwarf stars from more distant red giants. This study is based upon deep photographic and CCD photometry at optical (V, R, I) bandpasses toward the most highly obscured portions of the Taurus and Ophiuchus molecular clouds. The total volume delimited by the clouds is approximately 200 cu pc. Within this region our survey is complete for all stars brighter than M(sub V) = 16-17 mag; at R and I, the survey is complete down to the lowest mass stars capable of sustaining core hydrogen burning. We estimate the faint end of the field star luminosity function for the composite Taurus and Ophiuchus foreground sample and find that it resembles the local luminosity function down to M(sub V) approx. 16. At still fainter magnitudes we find more stars than do photometric parallex studies of the polar regions. This difference widens dramatically if even the simplest correction for incompleteness is applied to our data. We therefore tentatively conclude that the luminosity function rises beyond M(sub V) approx. 16; even if we discard our attempts to correct for incompleteness in the faintest magnitude bins, the luminosity function at least remains flat for the lowest mass stars. Our provisional finding that the luminosity function rises beyond its well-known peak at M(sub V) approx. 12-13, implies that the initial mass function (IMF) probably rises beyond the turnover point associated with this peak. Even if our most conservative estimate for the faint end of the luminosity function is used-in which no corrections are made for incompleteness-the IMF must at least remain flat down to the edge of the hydrogen-burning main sequence.

Jarrett, T. H.↗

DETERMINATION OF LOW-ENERGY CUTOFFS AND TOTAL ENERGY OF NONTHERMAL ELECTRONS IN A SOLAR FLARE ON 2002 APRIL 15

The determination of the low-energy cutoff to the spectrum of accelerated electrons is decisive for the estimation of the total nonthermal energy in solar flares. Because thermal bremsstrahlung dominates the low-energy part of flare X-ray spectra, this cutoff energy is difficult to determine with spectral fitting alone. We have used anew method that combines spatial, spectral, and temporal analysis to determine the cutoff energy for the M1.2 flare observed with RHESSI on 2002 April 15. A low-energy cutoff of 24 +/- 2 keV is required to ensure that the assumed thermal emissions always dominate over nonthermal emissions at low energies (<20 keV) and that the spectral fitting results are consistent with the RHESSI light curves and images. With this cutoff energy, we obtain a total nonthermal energy in electrons of (1.6 +/- 1) x 10(exp 30) ergs that is comparable to the peak energy in the thermal plasma, estimated from RHESSI observations to be (6 +/- 0.6) x 10(exp 29) ergs assuming a filling factor of 1.

Sui, Linhui↗

Advance Technology Satellites in the Commercial Environment. Volume 2: Final Report

A forecast of transponder requirements was obtained. Certain assumptions about system configurations are implicit in this process. The factors included are interpolation of baseline year values to produce yearly figures, estimation of satellite capture, effects of peak-hours and the time-zone staggering of peak hours, circuit requirements for acceptable grade of service capacity of satellite transponders, including various compression methods where applicable, and requirements for spare transponders in orbit. The graphical distribution of traffic requirements was estimated.

Source record↗

Confirmation of the E(sup src)(sub Peak)-E(sub iso) (Amati) relation from the x-ray flash XRF 050416A observed by the Swift burst alert telescope

We report Swift Burst Alert Telescope (BAT) observations of the X-ray flash (XRF) XRF 050416A. The fluence ratio between the 15-25 and 25-50 keV energy bands of this event is 1.5, thus making it the softest gamma-ray burst (GRB) observed by BAT so far. The spectrum is well fitted by a Band function with E(sup obs)(sub peak) of 15.0(sup +2.3)(sub -2.7) keV. Assuming the redshift of the host galaxy (z = 0.6535), the isotropic equivalent radiated energy E(sub iso) and the peak energy at the GRB rest frame (E(sup src)(sub peak)) of XRF 050416A are not only consistent with the correlation found by Amati et al. and extended to XRFs by Sakamoto et al. but also fill in the gap of this relation around the 30-80 keV range of E(sup src)(sub peak). This result tightens the validity of the E(sup src)(sub Peak)-E(sup src)(sub peak) relation from XRFs to GRBs. We also find that the jet break time estimated using the empirical relation between E(sup src)(sub peak) and the collimation corrected energy E(sub gamma), is inconsistent with the afterglow observation by the Swift X-Ray Telescope. This could be due to the extra external shock emission overlaid around the jet break time or to the nonexistence of a jet break feature for XRFs, which might be a further challenge for GRB jet emission models and XRF/GRB unification scenarios.

Sakamoti, T.↗

Field testing and validation of a low-cost MPC for demand flexibility for grid-interactive K-12 schools

K-12 school buildings account for the highest energy consumption within the public sector. Implementing advanced HVAC controls in grid-interactive K-12 schools could bring substantial economic advantages and grid flexibility. Our previous study demonstrated that a low-cost model predictive control (MPC) solution, which coordinates multiple packaged units, can enable demand flexibility without major hardware upgrades. However, a significant gap remains between academic pilots and market-ready scalable solutions. This paper extends the previous single-site pilot to a multi-site demonstration involving three school campuses (95 total units) through a commercial technology transfer process. Addressing the challenge of verifying performance with sparse field data, we present a new statistical approach using Bayesian methods to estimate the MPC’s effect on peak demand. Unlike traditional methods, this approach robustly quantifies uncertainty in non-normal, limited datasets. The results confirm the solution’s replicability, achieving a 21.6–38.9% reduction in HVAC peak demand (10.8–22.1% at the site-level) with > 98% probability across diverse locations. Finally, we document critical barriers to scaling software-as-a-service (SaaS) solutions–such as API instability and diverse legacy systems–and offer practical strategies to accelerate the commercial adoption of grid-interactive efficient buildings.

Ham, Sang Woo↗