Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Concept of Operations for Advanced Reactor Spent Nuclear Fuel Management

This presentation presents a preliminary description of a concept of operations to incorporate advanced-reactor spent nuclear fuel (SNF) into an integrated waste-management system (IWMS). The evaluation includes SNF from four advanced-reactor concepts with the following fuel types: (1) small modular reactors using oxide fuels, (2) tristructural-isotropic (TRISO) fuels, (3) metallic fuels, and (4) fuel salts. To provide context for the proposed concept of operations for advanced reactors, a comparison is made with traditional light-water reactors (LWRs) to identify potential gaps in the IWMS. The technical differences between advanced reactors and LWRs are assessed to determine the feasibility of managing advanced-reactor waste streams using existing operations and technology. This presentation emphasizes fuel types from Advanced Reactor Demonstration Program reactors: Xe 100, which uses TRISO fuel and Natrium, with its metallic fuels while also analyzing management options for molten-salt reactors and advanced light-water reactors (ALWRs). Understanding the storage, transportation, and disposal requirements of SNF is dependent on both the quantity and characteristics of the SNF generated by nuclear reactors. This presentation provides a high level overview, comparing the anticipated concept of operations for different SNFs from advanced reactors. The IWMS includes at-reactor storage, transportation, potential off-site storage, potential treatment, and disposition. To assess the potential effect of advanced-reactor concept of operations on the IWMS, estimates were made for fuel characteristics that contribute to storage, transportation, disposal, and possible treatment of advanced-reactor SNF. These include canister heat load, dose rates, and criticality-control limits, which are important for determining the condition and configuration of the advanced reactor SNF. At-reactor storage of LWR SNF traditionally involves a spent-fuel pool (SFP) before transfer to an independent spent-fuel storage installation. However, some advanced-reactor concepts, particularly those using TRISO and salt fuels, do not anticipate the use of an SFP. This difference in at-reactor storage could impact the IWMS. Additionally, transportation of advanced-reactor SNF may include additional processes tied to potential off gassing, and transportation of microreactor SNF may occur within the reactor vessel. Some advanced-reactor SNF could also undergo treatment to meet requirements of an acceptable waste form for disposition, and the treatment location will be a major contributor to efficiently performing IWMS responsibilities. Moreover, the quantity of SNF generated is an important consideration for IWMS because it could affect the size of the transportation fleet and potential off-site storage requirements. Additionally, volume and heat load are the primary drivers for SNF disposition. This presentation compares potential packaging options for advanced reactor SNF with traditional LWR packaging to provide a high-level comparison for the needs of the IWMS for advanced-reactor SNF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Loss Landscape Analysis for Reliable Quantized ML Models for Scientific Sensing

In this paper, we propose a method to perform empirical analysis of the loss landscape of machine learning (ML) models. The method is applied to two ML models for scientific sensing, which necessitates quantization to be deployed and are subject to noise and perturbations due to experimental conditions. Our method allows assessing the robustness of ML models to such effects as a function of quantization precision and under different regularization techniques -- two crucial concerns that remained underexplored so far. By investigating the interplay between performance, efficiency, and robustness by means of loss landscape analysis, we both established a strong correlation between gently-shaped landscapes and robustness to input and weight perturbations and observed other intriguing and non-obvious phenomena. Our method allows a systematic exploration of such trade-offs a priori, i.e., without training and testing multiple models, leading to more efficient development workflows. This work also highlights the importance of incorporating robustness into the Pareto optimization of ML models, enabling more reliable and adaptive scientific sensing systems.

Baldi, Tommaso [Pisa, Scuola Normale Superiore]↗

Efficiently improving the performance of noisy quantum computers

Using near-term quantum computers to achieve a quantum advantage requires efficient strategies to improve the performance of the noisy quantum devices presently available. We develop and experimentally validate two efficient error mitigation protocols named "Noiseless Output Extrapolation" and "Pauli Error Cancellation" that can drastically enhance the performance of quantum circuits composed of noisy cycles of gates. By combining popular mitigation strategies such as probabilistic error cancellation and noise amplification with efficient noise reconstruction methods, our protocols can mitigate a wide range of noise processes that do not satisfy the assumptions underlying existing mitigation protocols, including non-local and gate-dependent processes. We test our protocols on a four-qubit superconducting processor at the Advanced Quantum Testbed. We observe significant improvements in the performance of both structured and random circuits, with up to 86 % improvement in variation distance over the unmitigated outputs. Our experiments demonstrate the effectiveness of our protocols, as well as their practicality for current hardware platforms.

97 MATHEMATICS AND COMPUTING↗

FPGA-based HPC accelerators: An evaluation on performance and energy efficiency

Hardware specialization is a promising direction for the future of digital computing. Reconfigurable technologies enable hardware specialization with modest non-recurring engineering cost, but their performance and energy efficiency compared to state-of-the-art processor architectures remain an open question. In this article, we use FPGAs to evaluate the benefits of building specialized hardware for numerical kernels found in scientific applications. In order to properly evaluate performance, we not only compare Intel Arria 10 and Xilinx U280 performance against Intel Xeon, Intel Xeon Phi, and NVIDIA V100 GPUs, but we also extend the Empirical Roofline Toolkit (ERT) to FPGAs in order to assess our results in terms of the Roofline model. We show design optimization and tuning techniques for peak FPGA performance at reasonable hardware usage and power consumption. As FPGA peak performance is known to be far less than that of a GPU, we also benchmark the energy efficiency of each platform for the scientific kernels comparing against microbenchmark and technological limits. Results show that while FPGAs struggle to compete in absolute terms with GPUs on memory- and compute-intensive kernels, they require far less power and can deliver nearly the same energy efficiency.

97 MATHEMATICS AND COMPUTING↗

A Scalable Hardware-and-Human-in-the-Loop Grid-interactive Efficient Building Equipment Performance Dataset

This project developed a publicly available, high-fidelity dataset about the interactions among humans, homes, and heat pumps supporting grid interactive efficient buildings to balance demand on the grid with comfort for occupants. Laboratory measurements and simulations of the hardware capture the second-scale electric power dynamics of heat pumps providing grid services like load shifting and load shedding. Field measurements, behavior tracking, and qualitative surveys of people in their homes over multiple years—including experimentally adjusting the heating and cooling system to provide grid services—to capture the reciprocal effect of human behavior on grid services, and grid services on human comfort. Taken together, these data capture the complete Hardware and Human in the loop system for residential heat pumps, reducing large uncertainties in simulation for design, and models for control of heat pumps, and grid-interactive buildings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Efficiency and Capacity Performance of a Stirling-Cycle Water-to-Water Heat Pump

The performance of a 10 kW (2.8 ton) heat pump has been modeled in preparation for evaluation in a controlled-atmosphere psychrometric facility. The heat pump uses an electrically driven Stirling engine with nitrogen as a working fluid. The appropriate standards for testing are ANSI/AHRI/ASHRAE ISO Standard 13256-2:1998 (RA 2012), Water-Source Heat Pumps—Testing and Rating for Performance—Part 2: Water-to-Water and Brine-to-Water Heat Pumps. The heating and cooling efficiency and capacity of the device has been modeled at different hot and cold sink temperatures spanning a wide range of possible operating conditions. The heat pump was designed for a seasonal efficiency energy ratio (SEER) of 22. The high efficiency of this product coupled with the use of nitrogen as a working fluid makes it an important tool for the decarbonization of residential, commercial, and industrial HVAC&R applications.

Kowalski, Steve↗

Variable Refrigerant Flow Performance: Humidity and Efficiency in Multifamily Buildings in New York, NY

Variable refrigerant flow (VRF) systems have become common in large multifamily buildings. The upfront cost is appealing to developers, as a single system can provide all heating and cooling. VRF systems also use no on-site fossil fuels which can help avoid greenhouse gas emissions. However, there have been very few data on how VRF systems actually perform in buildings. Researchers monitored three new, multifamily buildings with a focus on VRF system sizing, humidity control, and energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving chiller performance and energy efficiency in hydrogen station operation by tuning the auxiliary cooling

In a hydrogen station that operates with direct fueling through the use of a 700 bar boost compressor, the outlet hydrogen temperature can significantly increase, stressing the chiller system. Here, this paper evaluates improvements that can be made to the auxiliary cooling system integrated with the compressor. Both theoretical modeling and experiments were performed at Cal State LA Hydrogen Research and Fueling Facility. The findings suggest that adjusting the auxiliary closed-loop cooling system from 15 °C to 10 °C reduced the station energy consumption and decreased the demand on the station chiller that needed to provide –20 °C hydrogen at the hose. The overall energy consumption for a single fueling reduced by between 2.86 and 9.43% for the set of experiments conducted. After the temperature of the closed-loop cooling system was reduced by 5 °C, the boost compressor outlet temperature dropped from 46-50 °C–40 °C and consequently at the hose the hydrogen temperature declined by 3 °C. Results were scaled up with a forecast on the number of daily refueling events. With a low number of daily fuelings, the proposed set-up showed a minor influence on the overall station energy consumption. However, the benefits were more pronounced for a connector station with sales at 180 kg/day, where the energy efficiency improved by between 1.4 and 5.5%, and even more so for a higher capacity station at 360 kg/day, where the improvement was between 2.9 and 8%.

08 HYDROGEN↗

Multi-hydrophilic functional network enables porous membranes excellent anti-fouling performance for highly efficient water remediation

Membrane technology is believed as a cost-effective approach for solving the water issues, where as it suffers from serious membrane fouling. Surface grafting and surface coating have been proved to be effective in abating the membrane fouling; however, these processes always need additional procedures and compromise the initial permeance of the membranes. Herein, we developed a kind of highly permeable polyacrylonitrile (PAN) membranes with excellent anti-fouling performance through one-step phase inversion of the PAN casting solution containing water-soluble active additives. During the process, the water-soluble active additives could segregate towards the membrane surface and pore walls; thereby finely tailoring the pore structures of the PAN-based membranes. Moreover, the active additives could react with each other to form crosslinked networks containing multi-hydrophilic functional groups including CH2-O-CH2, -OH or-Si-OH. Consequently, the PAN-based membranes exhibited surprising superhydrophilicity with water contact angle below 10. even after soaking in water for one week and the anti-fouling permeance of the membranes increased significantly with permeance recovery rate above 93%. Interestingly, the modified membranes also demonstrated both high permeances and high separation efficiency, thereby showing strong promise in water environmental remediation including wastewater treatment and oil/water emulsion separation.

Anti-fouling↗

Modeling the performance and faradaic efficiency of solid oxide electrolysis cells using doped barium zirconate perovskite electrolytes

Y-doped BaZrO 3 (BaZr 1 x Y x O 3 δ , or “BZY”), a proton-conducting ceramic featuring high bulk conductivity and good chemical stability, is a promising electrolyte material for solid oxide electrolysis cells. Further doping with Ce and/or Yb (creating materials “BCZY” and “BCZYYb”) can improve conductivity and sintering properties, but at significant penalty to cells’ faradaic efficiency (FE). Studies have proposed that reduction of lattice Ce can occur in the hydrogen electrode, which consumes some hydrogen produced by the hydrogen evolution reaction, leading to decreased FE. Despite studies suggesting this phenomenon, the mechanism is largely unknown. In this work, we developed a multiphysics model to study the transport of multiple defect species and the performance of BZY, BCZY, and BCZYYb, capturing the tradeoff between enhanced performance at the cost of FE for BCZY and BCZYYb electrolytes compared to BZY. We also found that increasing the water content of the anode gas supply lowers the current output of the cell but results in better FE. The model, which uses several parameters previously unavailable in the literature, was validated to experiments varying temperature, steam water content, and electrolyte material, as well as two performance metrics (performance curves and FE). Results verify and explain observed trends, informing future work on Ce-doped BZY electrolytes.

08 HYDROGEN↗

A patterned phase-changing vanadium dioxide film stacking with VO 2 nanoparticle matrix for high performance energy-efficient smart window applications

A vanadium dioxide (VO 2 ) based solid-to-solid phased changing material has been attracting great interest in smart window applications. However, achieving high solar modulation and high transparency simultaneously in visible light is the major challenge for the practical application of this smart material. To resolve this issue, in this paper, a smart film composed of a VO 2 nanoparticle matrix and a patterned VO 2 film is presented. Furthermore, numerical modeling and electromagnetic simulation are carried out to characterize the performance in terms of solar modulation and luminous transmittance, and a parametric study is carried out to optimize the proposed smart window film. Compared with the VO 2 nanoparticle matrix, the proposed structure can obtain 23% solar modulation and 57% luminous transmittance but with a much thinner thickness, which will significantly reduce the cost and fabrication complexity and extend the environment stability.

42 ENGINEERING↗

An Efficient Annual-Performance Model of a Geothermal Network for Improved System Design, Operation, and Control: Preprint

Geothermal district energy systems (DES), and specifically geothermal networks, provide a viable solution for decarbonizing residential and commercial heating and cooling loads. District energy systems of all kinds enable a thermal resource with a relatively high capital cost (such as a geothermal borehole field) to be shared among a large number of users. While district heating and cooling has been studied for many years, geothermal networks, fifth generation DES that utilize water-source heat pumps and an ambient temperature loop to meet heating and cooling loads, have not been implemented extensively and thus require additional technical and economic optimization to obtain maximum benefits. This paper presents a newly developed reduced-order model that captures the flow of energy within the network, including the commercial and residential users' electrical usage, at an hourly rate over a year. The model includes building loads, heat pumps, borehole fields, and auxiliary heat/cool input, all connected with an ambient-temperature thermal loop model. In the model, operational control is possible for the borehole fields, circulation pump, and auxiliary system. For a given system, the model can output the complete state parameters for each component, the thermal loop, and the collective system, such as flow rate over time, average thermal loop temperature over time, and total electricity usage. The model can also be used to optimize the system control for maximizing system efficiency or minimizing system operational cost. For example, one initial assessment of the borehole controller for an example system showed that a controller with on/off operation of the borehole field reduces annual electrical usage by 33%, compared with continuous operation mode. Hence, the model can assist in optimizing a given system's operation to get the most value out of a geothermal network installation. Future work will consider the model's application to a demonstration project, including the model validation against operational data and system operation optimization.

ambient-temperature loop↗

Enhanced hindrance from phenyl outer side chains on nonfullerene acceptor enables unprecedented simultaneous enhancement in organic solar cell performances with 16.7% efficiency

Inner side-chain engineering on Y6 has been a proven successful in improving short-circuit current density (JSC) through fine-tuning aggregated structures of acceptors. However, it fails in tuning the lowest unoccupied molecular orbital level (LUMO) and open-circuit voltage (V OC ). In this paper, we turn to focus on engineering the outer side chains on the flanking thienothiophene units with 4-hexylphenyl (PhC6) and 6-phenylhexyl (C6Ph) chains. Use of PhC6 enhances the steric effect between the attached phenyl and the ending group, which in combination with the additional conjugation effect provided by the linking phenyl leads to upshifted energy levels and increased V OC as a result. Again, substitution with the bulkier PhC6 unprecedentedly improves film-morphology with reduced paracrystalline disorder and long period and increased root-mean-square composition variations as well, leading to increased electron and hole mobilities and suppressed monomolecular recombination with J SC and fill-factor (FF) simultaneously enhanced. The PM6:BTP-PhC6-based devices yield a higher efficiency value of 16.7% than the PM6:BTP-C6Ph-based one (15.5%). Furthermore, this study shows a conceptual advance in materials design towards reducing the conflict between V OC and J SC in binary blended organic solar cells, which can be achieved by introducing bulkier chains to twist the backbone and simultaneously enhance the packing order.

14 SOLAR ENERGY↗

Critical review and future prospects for desiccant coated heat exchangers: Materials, design, and manufacturing

Solid desiccant dehumidification is a promising alternative to vapor compression-based air-dehumidification to reduce energy consumption and improve air quality. Desiccant coated heat exchanger (DCHE), as one type of solid desiccant dehumidification system, can improve system performance and efficiency. The thermal performance and moisture removal capability of the DCHE greatly influence its dehumidification performance.The present work aims to critically analyze the designs, materials, and manufacturing methods of heat exchangers used for solid desiccant coating and look into recent developments in regular heat exchangers, potentially deployed as a substrate for DCHE applications. A comprehensive literature review of publications regarding solid desiccant materials, heat exchangers, manufacturing and coating methods, binder materials, and the performance of heat exchangers has been developed. Alternative heat exchangers are described as better options than fin and tube heat exchangers that have been considered thus far for DCHE applications. Additionally, the heat exchanger's manufacturing process and materials over their thermal and mass exchange performance have been analyzed. Despite the widespread use of fin and tube heat exchangers for solid desiccant coating, recent developments in heat exchanger design, and related fields such as manufacturing methods and materials, open the possibilities for their application in solid desiccant dehumidification systems. Lastly, the authors provide their outlook on possible developments of DCHE technology, aiming to increase systems' energy and dehumidification performance.

36 MATERIALS SCIENCE↗

Deffe: A Data-efficient Framework for Performance Characterization in Domain-Specific Computing

Predicting workload performance is a crucial task for many architecture and system research. In this paper we present De￿e, a framework to estimate the workload performances under varying architectural configurations. The infrastructure component of Deffe is based on scalable and easy-to-use open-source software components. By casting the performance modeling as transfer learning tasks, the modeling component of Deffe can leverage the learned knowledge on one workload, and “transfer” it to a new workload. Extensive experimental results show that the method can achieve superior testing accuracy with an effective reduction of 32-80x in terms of the amount of required training data.

Liu, Frank↗

Analysis of combustion chamber deposit growth on temperature swing thermal barrier coatings in a spark ignition engine

Temperature swing thermal barrier coatings (TBCs) have the potential to improve efficiency and performance through thermal management of the combustion chamber. However, the effects of combustion chamber deposits (CCDs) on the surface of the TBCs are unclear. Therefore, this paper analyzes the impact of CCD formation on a temperature swing TBC. A piston and a heat flux probe coated with a novel material are installed in a single-cylinder research engine at a low-load condition for 62.5 h to promote CCD growth. Every 12.5 h, the performance at a knock limited condition is assessed and thermophysical property measurements on the heat flux probe are performed. Net thermal efficiency increased by 0.4% absolute after 12.5 h relative to the baseline condition, but further CCD growth caused a dithering of efficiency between the 12.5 h and baseline points. The KLSA retarded consistently throughout this period. As a result, external property measurements with the coated heat flux probe showed an improvement in the thermophysical properties of the TBC/CCD layer.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Portability Evaluation of OpenCL Benchmarks across Intel and NVIDIA Platforms

We evaluate the capabilities of vendor-provided OpenCL implementations for performance portability across multiple computing platforms. The Rodinia benchmark suite is used for this evaluation. We apply the metric defined by Pennycook et al., and we use roofline efficiency from the Roofline performance model as the "performance efficiency" in the metric's definition. We found that the delivered performance portability is similar for several benchmarks, even if the roofline-based performance efficiencies across platforms are very different among the benchmarks. To help distinguish between these instances, we extend the metric by adding the standard deviation of the performance efficiencies for each benchmark. We argue that the standard deviation gives additional insight into performance portability assessment since it adds the performance variability across platforms. Additionally, we discuss the challenges to measure performance portability associated with algorithms and system software. In terms of algorithms, we need to carefully construct the benchmarks and appropriately use the concurrency available on a platform. In terms of system software, we depend on the vendor performance tools to support the desired programming model and runtime to be able to measure the metrics of interest.

GPU↗