Search NASA⌕ Search

SEARCH · Search NASA

Results for “permeability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Citizen Green #1 Well : Sidewall Core Permeability Studies

This submission includes information on porosity & permeability measurements conducted on sidewall cores from the Citizen Green #1 well drilled on King Island, CA (API 07720688) as part of the WESTCARB partnership basin characterization effort. Cores were acquired with a rotary sidewall tool at a range of depths; only deeper cores were sufficiently consolidated for analysis. SidewallCoreFormationDepthNotes.xls provides details on available samples. Helium porosimetry, air permeability, and brine permeability measurements were conducted on all competent samples (~15). Samples were largely in the Mokelumne, H&T shale, and Starkey formations. All measurements were conducted by Core Laboratories (Bakersfield) on behalf of Lawrence Berkeley National Laboratory (LBNL) with final reports provided in November of 2012. Further measurements were conducted on some sidewalls with data in other submissions.

pemeability↗

Controlling Sustainability of Hydraulic Fracture Permeability in Ductile Shales

Hydraulic fracturing technology, along with horizontal drilling and associated completion technologies, dramatically increased US oil and gas production, by increasing the permeability of tight shales and allowing for cost-effective extraction of trapped hydrocarbons. For efficient and economical production, the targeted shale has to be fractured easily (i.e., good ‘frackability’), but also the permeability of induced fractures have to be sustained during production (good ‘sustainability’). For these reasons, currently, ductile shale with high clay content (>~40%) is difficult to exploit as a hydrocarbon resource, although hydrocarbons can still be found in it. Good frackability, high-TOC, low-clay-content resource shales—the ‘low-hanging fruit’—will be depleted, and we need to develop tools that allow tapping into currently underutilized, clay-rich ductile shales. This research project aims (1) to understand the behavior of fractures in clay-rich, ductile (and sometimes swelling) shales and (2) to begin to develop technologies for efficient and economical production from such shales. With these objectives, we examine time-dependent, coupled mechanical-hydrological behavior of open and proppant-filled fractures within different types of shales. In the preceding project, the focus of the research was to understand the behavior of the fractures and to predict their permeability changes due to fracture closure from shale matrix deformation and proppant embedment. In the current project, we investigate the possibility of chemically manipulating the sustainability of hydraulic fractures in ductile shales—specifically by altering the proppant-embedding behavior—via chemical means, at different stages of oil and gas production.

04 OIL SHALES AND TAR SANDS↗

June 2022 Permeability Measurements in P-Tunnel, Nevada National Security Site

This document describes gas permeability measurements made in June 2022 in P-Tunnel at the Nevada National Security Site (NNSS). Four boreholes (AC-1, GI-5, GI-6, and HF-1) were tested with a dual packer system. The pressure versus flow rate data that were collected are analyzed using a numerical simulation method that captures compressible gas flow in partially saturated porous media using a close approximation to the geometry of the test setup. The first part of this document begins with data collection and a description of the packer assembly followed by details on data acquisition, measurement instrumentation, and equipment followed by a description of pre-test system verification. Next, the implementation of testing in the field is described, including how specific locations were chosen for testing. The second part of this document describes the numerical simulations used to back-out permeability from the pressure versus flow rate data. First, the numerical model is described, including assumptions. Next the details of the mesh that represents the experiment are described. A method for generating type curves in pressure versus flow rate space is presented and finally the data are mapped to permeability. We conclude with a discussion of the results.

54 ENVIRONMENTAL SCIENCES↗

Study of permeability characteristics of membranes

Pressure-permeation experiments were performed with the concentration-clamp cell. Streaming potentials and hydraulic permeabilities were measured for an AMF C-103 cation-exchange membrane bounded by 0.1 N NaCl solutions. The streaming potential calculated from the slope of the recorded potential differences versus the applied pressure, yields a value of 1.895 millivolt/dekabar. When comparison with other membranes of similar characteristics could be made, good agreement was found. The values of the hydraulic permeability varied somewhat with the applied pressure difference and are between 1.3 x 10 to the minus 8th power and 3.9 x 10 to the minus 8th power sq cm/dekabar-sec. The specific hydraulic permeabilities were also calculated and compared with data from the literature. Fair agreement was found. The diffusion coefficient of the chloride ion in the AMF C-103 membrane was calculated, using Fick's first law of diffusion based on ion concentrations calculated from the Donnan equilibrium concentration of Cl(-).

Spiegler, K. S.↗

Iron abundance and magnetic permeability of the moon

A larger set of simultaneous data from the Apollo 12 lunar surface magnetometer and the Explorer 35 Ames magnetometer are used to construct a whole-moon hysteresis curve, from which a new value of global lunar permeability is determined to be mu = 1.012 + or - 0.006. The corresponding global induced dipole moment is 2.1 x 10 to the 18th power gauss-cu cm for typical inducing fields of .0001 gauss in the lunar environment. From the permeability measurement, lunar free iron abundance is determined to be 2.5 + or - 2.0 wt. %. Total iron abundance (sum of iron in the ferromagnetic and paramagnetic states) is calculated for two assumed compositional models of the lunar interior: a free iron/orthopyroxene lunar composition and a free iron/olivine composition. The overall lunar total iron abundance is determined to be 9.0 + or - 4.7 wt. %. Other lunar models with a small iron core and with a shallow iron-rich layer are discussed in light of the measured global permeability.

Parkin, C. W.↗

Lunar electrical conductivity, permeability,and temperature from Apollo magnetometer experiments

Magnetometers were deployed at four Apollo sites on the moon to measure remanent and induced lunar magnetic fields. Measurements from this network of instruments were used to calculate the electrical conductivity, temperature, magnetic permeability, and iron abundance of the lunar interior. Global lunar fields due to eddy currents, induced in the lunar interior by magnetic transients, were analyzed to calculate and electrical conductivity profile for the moon, and those profiles were used to calculate the lunar temperature for an assumed lunar material of olivine. Simultaneous measurements by magnetometers on the lunar surface and in orbit around the moon were use to construct a whole-moon hysteresis curve, from which the global lunar magnetic permeability is determined. Total iron abundance (sum of iron in the ferromagnetic and paramagnetic states) was calculated for two assumed compositional models of the lunar interior. Other lunar models with an iron core and with a shallow iron-rich layer also discussed in light of the measured global lunar permeability. Simultaneous magnetic field and solar plasma pressure measurements show that the remanent fields at the Apollo 12 and 16 sites interact with, and are compressed by, the solar wind. Velocities and thicknesses of the earth's magnetopause and bow shock were also estimated from simultaneous magnetometer measurements.

Dyal, P.↗

Changes in mast cells and in permeability of mesenteric microvessels under the effect of immobilization and electrostimulation

It was shown that a reduction in the amount of mast cells in the mesentery and an increase in their degranulation was accompanied by an increase in vascular permeability of rat mesentery. It is supposed that immobilization and electrostimulation causing degranulation of mast cells prompted histamine and serotonin release from them, thus increasing the permeability of the venular portion of the microvascular bed. Prophylactic use of esculamin preparation with P-vitaminic activity decreased mast cell degranulation, which apparently prolonged the release of histamine and serotonin from them and normalized vascular permeability.

Gorizontova, M. P.↗

Vapor-liquid phase separator permeability results

Continued studies are described in the area of vapor-liquid phase separator work with emphasis on permeabilities of porous sintered plugs (stainless steel, nominal pore size 2 micrometer). The temperature dependence of the permeability has been evaluated in classical fluid using He-4 gas at atmospheric pressure and in He-2 on the basis of a modified, thermosmotic permeability of the normal fluid.

Yuan, S. W. K.↗

Effect of water on hydrogen permeability

Doping of hydrogen with CO and CO2 was developed to reduce hydrogen permeation in Stirling engines by forming a low permeability oxide coating on the inner surface of the heater head tubes. Although doping worked well, under certain circumstances the protective oxide could be chemically reduced by the hydrogen in the engine. Some oxygen is required in the hydrogen to prevent reduction. Eventually, all the oxygen in the hydrogen gas - whatever its source - shows up as water. This is the result of hydrogen reducing the CO, CO2, or the protective inner surface oxides. This water can condense in the engine system under the right conditions. If the concentration of water vapor is reduced to a low enough level, the hydrogen can chemically reduce the oxide coating, resulting in an increase in permeability. This work was done to define the minimum water content required to avoid this reduction in the oxide coating. The results of this testing show that a minimum of approximately 750 ppm water is required to prevent an increase in permeability of CG-27, a high temperature metal alloy selected for Stirling engine heater tubes.

Hulligan, David↗

A complex permittivity and permeability measurement system for elevated temperatures

The three goals of this research include: (1) to fully develop a method to measure the permittivity and permeability of special materials as a function of frequency in the range of 2.6 to 18 GHz, and of temperature in the range of 25 to 1100 C; (2) to assist LeRC in setting up an in-house system for the measurement of high-temperature permittivity and permeability; and (3) to measure the complex permittivity and permeability of special materials as a function of frequency and temperature to demonstrate the capability of the method. The method chosen for characterizing the materials relies on perturbation of a resonant cavity with a small volume of sample material. Different field configurations in the cavity can be used to separate electric and magnetic effects. The cavity consists of a section of rectangular waveguide terminated at each end of a vertical slot iris. In the center of one wall is a small hole through which the sample is introduced.

Friederich, Paul↗

A complex permittivity and permeability measurement system for elevated temperatures

The three goals of this research include: (1) to fully develop a method to measure the permittivity and permeability of special materials as a function of frequency in the range of 2.6 to 18 GHz, and of temperatures in the range of 25 to 1100 C; (2) to assist LeRC in setting up an in-house system for the measurement of high-temperature permittivity and permeability; and (3) to measure the complex permittivity and permeability of special materials as a function of frequency and temperature to demonstrate the capability of the method. The method chosen for characterizing the materials relies on perturbation of a resonant cavity with a small volume of sample material. Different field configurations in the cavity can be used to separate electric and magnetic effects. The cavity consists of a section of rectangular waveguide terminated at each end of a vertical slot iris. The center of one wall is a small hole through which the sample is introduced.

Friederich, Paul↗

Atrial natriuretic factor increases vascular permeability

An increase in central blood volume in microgravity may result in increased plasma levels of atrial natriuretic factor (ANF). In this study, it was determined whether ANF increases capillary permeability to plasma protein. Conscious, bilaterally nephrectomized male rats were infused with either saline, ANF + saline, or hexamethonium + saline over 2 h following bolus injections of (I-125)-albumin and (C-14)-dextran of similar molecular size. Blood pressure was monitored, and serial determinations of hematocrits were made. Animals infused with 1.0 microg/kg per min ANF had significantly higher hematocrits than animals infused with saline vehicle. Infusion of ANF increased the extravasation of (I-125)-albumin, but not (C-14)-dextran from the intravascular compartment. ANF also induced a depressor response in rats, but the change in blood pressure did not account for changes in capillary permeability to albumin; similar depressor responses induced by hexamethonium were not accompanied by increased extravasation of albumin from the intravascular compartment. ANF may decrease plasma volume by increasing permeability to albumin, and this effect of ANF may account for some of the signs and symptoms of space motion sickness.

Lockette, Warren↗

Instrumentation for Measurement of Gas Permeability of Polymeric Membranes

A mass spectrometric 'Dynamic Delta' method for the measurement of gas permeability of polymeric membranes has been developed. The method is universally applicable for measurement of the permeability of any gas through polymeric membrane materials. The usual large sample size of more than 100 square centimeters required for other methods is not necessary for this new method which requires a size less than one square centimeter. The new method should fulfill requirements and find applicability for industrial materials such as food packaging, contact lenses and other commercial materials where gas permeability or permselectivity properties are important.

Upchurch, Billy T.↗

Porosity and Permeability of Chondritic Materials

We have investigated the porosity of a large number of chondritic interplanetary dust particles and meteorites by three techniques: standard liquid/gas flow techniques, a new, non-invasive ultrasonic technique, and image processing of backscattered images . The latter technique is obviously best suited to sub-kg sized samples. We have also measured the gas and liquid permeabilities of some chondrites by two techniques: standard liquid/gas flow techniques, and a new, non-destructive pressure release technique. We find that chondritic IDP's have a somewhat bimodal porosity distribution. Peaks are present at 0 and 4% porosity; a tail then extends to 53%. These values suggest IDP bulk densities of 1.1 to 3.3 g/cc. Type 1-3 chondrite matrix porosities range up to 30%, with a peak at 2%. The bulk porosities for type 1-3 chondrites have the same approximate range as exhibited by matrix, indicating that other components of the bulk meteorites (including chondrules and aggregates) have the same average porosity as matrix. These results reveal that the porosity of primitive materials at scales ranging from nanogram to kilogram are similar, implying similar accretion dynamics operated through 12 orders of size magnitude. Permeabilities of the investigated chondrites vary by several orders of magnitude, and there appears to be no simple dependence of permeability with degree of aqueous alteration, or chondrite type.

Zolensky, Michael E.↗

Hydrogen Permeability of a Polymer Based Composite Tank Material Under Tetra-Axial Strain

In order to increase the performance of future expendable and reusable launch vehicles and reduce per-pound payload launch costs, weight reductions have been sought in vehicle components. Historically, the cryogenic propellant tanks for launch vehicles have been constructed from metal. These are some of the largest structural components in the vehicle and contribute significantly to the vehicles total dry weight. A successful replacement material will be conformable, have a high strength to weight ratio, and have a low gas-permeability to the cryogens being stored, i.e., oxygen and hydrogen. Polymer-based composites are likely candidates to fill this role. Polymer and polymer-based composites in general are known to have acceptable gas permeation properties in their as-cured state.1 The use of polymer-based composites for this application has been proposed for some time.2 Some successes have been reported with oxygen3, but other than the DC-XA experience, those with hydrogen have been limited. The primary reason for this has been the small molecular diameter of hydrogen, the lower temperatures of the liquid, and that the composite materials examined to date have all been susceptible to microcrack formation in response to the thermal-mechanical cycles experienced in the use-environment. There have been numerous accounts of composite materials with reported acceptable resistance to the formation of microcracks when exposed to various mechanical and/or thermal cycles. However, virtually all of these studies have employed uniaxial loads and there has been no discussion or empirical evidence pertaining to how these loads relate to the biaxial state of stress in the material in its use environment. Furthermore, many of these studies have suffered from a lack of instrument sensitivity in detecting hydrogen permeability, no standards, insufficient documentation of test conditions, testing of cycled materials in their unload state, and/or false assumptions about the nature of the microcracks in the material. This paper documents the results of hydrogen permeability testing on a Bismaleimide (BMI) based graphite fiber composite material under a variety of tetra-axial strain states.

Stokes, Eric H.↗

A calcium-permeable cGMP-activated cation conductance in hippocampal neurons

Whole-cell patch clamp recordings detected a previously unidentified cGMP-activated membrane conductance in cultured rat hippocampal neurons. This conductance is nonselectively permeable for cations and is completely but reversibly blocked by external Cd2+. The Ca2+ permeability of the hippocampal cGMP-activated conductance was examined in detail, indicating that the underlying ion channels display a high relative permeability for Ca2+. The results indicate that hippocampal neurons contain a cGMP-activated membrane conductance that has some properties similar to the cyclic nucleotide-gated channels previously shown in sensory receptor cells and retinal neurons. In hippocampal neurons this conductance similarly could mediate membrane depolarization and Ca2+ fluxes in response to intracellular cGMP elevation.

Non-NASA Center↗

Micromechanics, Fracture Mechanics and Gas Permeability of Composite Laminates for Cryogenic Storage Systems

A micromechanics method is developed to investigate microcrack propagation in a liquid hydrogen composite tank at cryogenic temperature. The unit cell is modeled using square and hexagonal shapes depends on fiber and matrix layout from microscopic images of composite laminates. Periodic boundary conditions are applied to the unit cell. The temperature dependent properties are taken into account in the analysis. The laminate properties estimated by the micromechanics method are compared with empirical solutions using constituent properties. The micro stresses in the fiber and matrix phases based on boundary conditions in laminate level are calculated to predict the formation of microcracks in the matrix. The method is applied to an actual liquid hydrogen storage system. The analysis predicts micro stresses in the matrix phase are large enough to cause microcracks in the composite. Stress singularity of a transverse crack normal to a ply-interface is investigated to predict the fracture behavior at cryogenic conditions using analytical and finite element analysis. When a transverse crack touches a ply-interface of a composite layer with same fiber orientation, the stress singularity is equal to 1/2. When the transverse crack propagates to a stiffer layer normal to the ply-direction, the singularity becomes less than 1/2 and vice versa. Finite element analysis is performed to predict the fracture toughness of a laminated beam subjected to fracture loads measured by four-point bending tests at room and cryogenic temperatures. As results, the fracture load at cryogenic temperature is significantly lower than that at room temperature. However, when thermal stresses are taken into consideration, for both cases of room and cryogenic temperatures, the difference of the fracture toughness becomes insignificant. The result indicates fracture toughness is a characteristic property, which is independent to temperature changes. The experimental analysis is performed to investigate the effect of cryogenic cycling on permeability for various composite material systems. Textile composites have lower permeability than laminated composites even with increasing number of cryogenic cycle. Nano-particles dispersed in laminated composites do not show improvement on permeability. The optical inspection is performed to investigate the microcrack propagation and void content in laminated composites and compared the microscopic results before and after cryogenic cycling.

Choi, Sukjoo↗

Oxygen-Permeable, Hydrophobic Membranes of Silanized alpha-Al2O3

Membranes made of silanized alumina have been prepared and tested as prototypes of derivatized ceramic membranes that are both highly permeable to oxygen and hydrophobic. Improved oxygen-permeable, hydrophobic membranes would be attractive for use in several technological disciplines, including supporting high-temperature aqueousphase oxidation in industrial production of chemicals, oxygenation of aqueous streams for bioreactors, and oxygenation of blood during open-heart surgery and in cases of extreme pulmonary dysfunction. In comparison with organic polymeric oxygen-permeable membranes now commercially available, the derivatized ceramic membranes are more chemically robust, are capable of withstanding higher temperatures, and exhibit higher oxygen-diffusion coefficients.

Atwater, James E.↗