Search NASA⌕ Search

SEARCH · Search NASA

Results for “phase calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

External calibration of polarimetric radar images using distributed targets

A new technique is presented for calibrating polarimetric synthetic aperture radar (SAR) images using only the responses from natural distributed targets. The model for polarimetric radars is assumed to be X = cRST where X is the measured scattering matrix corresponding to the target scattering matrix S distorted by the system matrices T and R (in general T does not equal R(sup t)). To allow for the polarimetric calibration using only distributed targets and corner reflectors, van Zyl assumed a reciprocal polarimetric radar model with T = R(sup t); when applied for JPL SAR data, a heuristic symmetrization procedure is used by POLCAL to compensate the phase difference between the measured HV and VH responses and then take the average of both. This heuristic approach causes some non-removable cross-polarization responses for corner reflectors, which can be avoided by a rigorous symmetrization method based on reciprocity. After the radar is made reciprocal, a new algorithm based on the responses from distributed targets with reflection symmetry is developed to estimate the cross-talk parameters. The new algorithm never experiences problems in convergence and is also found to converge faster than the existing routines implemented for POLCAL. When the new technique is implemented for the JPL polarimetric data, symmetrization and cross-talk removal are performed on a line-by-line (azimuth) basis. After the cross-talks are removed from the entire image, phase and amplitude calibrations are carried out by selecting distributed targets either with azimuthal symmetry along the looking direction or with some well-known volume and surface scattering mechanisms to estimate the relative phases and amplitude responses of the horizontal and vertical channels.

Yueh, Simon H.↗

Preparation of pigments for space-stable thermal control coatings

The identification and control of vapor phase reaction kinetics to produce pigments by homogeneous nucleation were achieved. A vapor phase apparatus was designed, fabricated, and calibrated through 1800 C. Vapor phase reactions were analyzed, calculations made, and powders of alumina, rutile, zinc orthotitanate (in a mixed phase), calcium tungstate, and lanthana were produced by homogeneous nucleation. Electron microscopy shows uniform particle morphology and size, and supports anticipated advantages of vapor-phase homogeneous nucleation; namely, purity, freedom from defects, and uniform particle sizing without grinding.

Campbell, W. B.↗

Phase identification using co‐association matrix ensemble clustering

Calibrating distribution system models to aid in the accuracy of simulations such as hosting capacity analysis is increasingly important in the pursuit of the goal of integrating more distributed energy resources. The recent availability of smart meter data is enabling the use of machine learning tools to automatically achieve model calibration tasks. This research focuses on applying machine learning to the phase identification task, using a co‐association matrix‐based, ensemble spectral clustering approach. The proposed method leverages voltage time series from smart meters and does not require existing or accurate phase labels. This work demonstrates the success of the proposed method on both synthetic and real data, surpassing the accuracy of other phase identification research.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A CALPHAD-informed approach to modeling constituent redistribution in Zr-based metallic fuels using BISON

Here, a CALPHAD-informed (Computer Coupling of Phase Diagrams and Thermochemistry) constituent redistribution model was developed for Zr-based metallic fuels and incorporated into the BISON fuel performance code. Three uncertain model parameters associated with β and γ phase kinetics were calibrated using integral test data from U-Zr fuel elements irradiated in Experimental Breeder Reactor II. The calibrated constituent redistribution model was shown to predict the behavior of U-Zr fuels with excellent accuracy. Model predictions for U-Pu-Zr fuels were physically reasonable but less accurate. Reduction of uncertainties in the ternary phase transition temperatures and collection of kinetic data for the ζ phase are expected to improve the model’s ternary predictions. Finally, the new model was coupled to existing thermomechanics models in BISON to simulate irradiation of an entire U-Zr fuel element, demonstrating its ability to accurately predict the behavior of U-Zr fuels with realistic geometries and mesh resolutions at the engineering scale.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High accuracy fuel flowmeter. Phase 2C and 3: The mass flowrate calibration of high accuracy fuel flowmeters

A facility for the precise calibration of mass fuel flowmeters and turbine flowmeters located at AMETEK Aerospace Products Inc., Wilmington, Massachusetts is described. This facility is referred to as the Test and Calibration System (TACS). It is believed to be the most accurate test facility available for the calibration of jet engine fuel density measurement. The product of the volumetric flow rate measurement and the density measurement, results in a true mass flow rate determination. A dual-turbine flowmeter was designed during this program. The dual-turbine flowmeter was calibrated on the TACS to show the characteristics of this type of flowmeter. An angular momentum flowmeter was also calibrated on the TACS to demonstrate the accuracy of a true mass flowmeter having a 'state-of-the-art' design accuracy.

Craft, D. William↗

USE OF THE SDO POINTING CONTROLLERS FOR INSTRUMENT CALIBRATION MANEUVERS

During the science phase of the Solar Dynamics Observatory mission, the three science instruments require periodic instrument calibration maneuvers with a frequency of up to once per month. The command sequences for these maneuvers vary in length from a handful of steps to over 200 steps, and individual steps vary in size from 5 arcsec per step to 22.5 degrees per step. Early in the calibration maneuver development, it was determined that the original attitude sensor complement could not meet the knowledge requirements for the instrument calibration maneuvers in the event of a sensor failure. Because the mission must be single fault tolerant, an attitude determination trade study was undertaken to determine the impact of adding an additional attitude sensor versus developing alternative, potentially complex, methods of performing the maneuvers in the event of a sensor failure. To limit the impact to the science data capture budget, these instrument calibration maneuvers must be performed as quickly as possible while maintaining the tight pointing and knowledge required to obtain valid data during the calibration. To this end, the decision was made to adapt a linear pointing controller by adjusting gains and adding an attitude limiter so that it would be able to slew quickly and still achieve steady pointing once on target. During the analysis of this controller, questions arose about the stability of the controller during slewing maneuvers due to the combination of the integral gain, attitude limit, and actuator saturation. Analysis was performed and a method for disabling the integral action while slewing was incorporated to ensure stability. A high fidelity simulation is used to simulate the various instrument calibration maneuvers.

Vess, Melissa F.↗

FTIR Study of Vapor Offgassing from Orbiter Tile Re-Waterproofing Materials

The work presented in this paper was performed to identify and quantify the offgassing behavior of alternative re-waterproofmg materials under investigation for application to Shuttle Orbiter Thermal Protection System (TPS) tile and blanket materials. The purpose was to determine whether the new materials would cause a problem with the operational analysis of residual vapors using the current portable vapor analyzer, a Miran 203. The materials investigated were limited to dimethylethoxysilane (DMES) and proposed solvent selected as suitable for use in re-waterproofing Orbiter TPS. The solvent was selected in another phase of the overall project. Obiter TPS tiles were injected with the re-waterproofing materials under constant conditions of temperature, relative humidity and air flow. The vapor concentrations of offgassing materials were monitored using Fourier Transform Infrared (FTIR) multi-component analysis, and with the Miran 203 instruments. The procedure was to record the time dependent concentrations of offgassing materials as analyzed by the FTIR, and the time response of the Miran 203 to the materials under consideration. The FTIR was calibrated for vapor phase DMES, tetramethyldisiloxane (TMDS), ethanol and the hydrocarbon solvents to be used to dilute the DMES for application to the TPS tile. The Miran 203 was calibrated for the operational measurement of DMES airborne vapors. The FTIR data, shows for the first time that the principal product which offgases from the tile after the first hour is not DMES, but TMDS and ethanol. The Miran 203 response to TMDS is the primary reading after the re-waterproofing operation is completed. The operational use of the Miran 203 to measure DMES vapors after re-waterproofmg operations has been responding to TMDS. The results of this study suggest that the historical complaints that have contributed to the low threshold limit value (TLV) for DMES concentrations, as read with the Miran 203, are actually based on instrumental responses to TMDS, for which no other toxicology information is available at this time. While there is some interference, the use of the tested hydrocarbon solvents does not adversely affect the response of the Miran 203.

Mattson, C. B.↗

Radiation Budget Instrument (RBI) for JPSS-2

Radiation Budget Instrument (RBI) will be one of five instruments flying aboard the JPSS-2 spacecraft, a polar-orbiting sun-synchronous satellite in Low Earth Orbit. RBI is a passive remote sensing instrument that will follow the successful legacy of the Clouds and Earth's Radiant Energy System (CERES) instruments to make measurement of Earth's short and longwave radiation budget. The goal of RBI is to provide an independent measurement of the broadband reflected solar radiance and Earth's emitted thermal radiance by using three spectral bands (Shortwave, Longwave, and Total) that will have the same overlapped point spread function (PSF) footprint on Earth. To ensure precise NIST-traceable calibration in space the RBI sensor is designed to use a visible calibration target (VCT), a solar calibration target (SCT), and an infrared calibration target (ICT) containing phase change cells (PCC) to enable on-board temperature calibration. The VCT is a thermally controlled integrating sphere with space grade Spectralon covering the inner surface. Two sides of the sphere will have fiber-coupled laser diodes in the UV to IR wavelength region. An electrical substitution radiometer on the integrating sphere will monitor the long term stability of the sources and the possible degradation of the Spectralon in space. In addition the radiometric calibration operations will use the Spectralon diffusers of the SCT to provide accurate measurements of Solar degradation. All those stable on-orbit references will ensure that calibration stability is maintained over the RBI sensor lifetime. For the preflight calibration the RBI will view five calibration sources - two integrating spheres and three CrIS (Cross-track Infrared Sounder ) -like blackbodies whose outputs will be validated with NIST calibration approach. Thermopile are the selected detectors for the RBI. The sensor has a requirement to perform lunar calibration in addition to solar calibration in space in a way similar to CERES instruments approach. To monitor climate change and to get stable and traceable results, it is critical to assure stable calibration over instrument lifetime.

Georgieva, Elena↗

The effects of stress, temperature and facet structure on growth of { 10 1 ¯ 2 } twins in Mg: a molecular dynamics and phase field study

The present study focuses on the roles of structure, stress and temperature on the mobility of facets bounding twin domains and on the overall impact on the growth kinetics of { 10 1 ¯ 2 } twins in Mg. We first use molecular dynamics simulations (MD) to study the relationship between interface structures, stress, temperature and mobility. As facets can exhibit distinct atomic scale structures, we also quantify the effect of stress relaxation mediated by misfit dislocations on the mobility of the basal-prismatic interface. The information gathered for ten different facets is used to calibrate an anisotropic phase field model predicting the effects of temperature and stress on the kinetics and shape of a growing { 10 1 ¯ 2 } 3D twin, by comparison with MD data. The comparative analysis suggests that, as compared to simulations of individual facets, the effective mobility of facets can be significantly different during growth of a 3D twin. This can be attributed to the complex three-dimensional internal stress state of the twin and to coupling in facet motion triggered by facet junctions. As such, by directly fitting both the twin growth kinetics and morphology as predicted by MD for different stresses and temperatures, we can identify a limited set of rate-limiting facets that control twin growth and morphology, and measure their effective mobility.

36 MATERIALS SCIENCE↗

The Radio Fundamental Catalogue. I. Astrometry

We present the all-sky catalogue of absolute positions and estimates of correlated flux density of 21,942 compact radio sources determined from processing interferometric visibility data of virtually all VLBI observing sessions at 2 to 23~GHz from 72 programs suitable for absolute astrometry collected for 30 years. We used a novel technique of generation of a dataset of fused observables that allowed us to incorporate all available data in our analysis. The catalogue is the most complete and most precise to date. It forms the foundation and reference for positional astronomy, space geodesy, space navigation, population analysis of active galactic nuclei (AGNs), and provides calibrators for phase-referencing for differential astrometry and VLBI astrophysical observations. Its accuracy was evaluated through a detailed accounting systematic errors, rigorous decimation tests, comparison of different datasets, and comparison with other catalogues. The catalogue samples preferentially the AGNs with a strong contemporary parsec-scale synchrotron emission. Its milliarcsecond level positional accuracy allows association of these AGNs with detections in a wide range of the electromagnetic spectrum from low-frequency radio to gamma-rays and high energy neutrinos. We describe the innovative data processing and calibration technique in full detail, report the in depth analysis of random and systematic positional errors, and provide the list of associations with large surveys at different wavelengths.

Astronomy↗

Digital Beamforming Scatterometer

This paper discusses scatterometer measurements collected with multi-mode Digital Beamforming Synthetic Aperture Radar (DBSAR) during the SMAP-VEX 2008 campaign. The 2008 SMAP Validation Experiment was conducted to address a number of specific questions related to the soil moisture retrieval algorithms. SMAP-VEX 2008 consisted on a series of aircraft-based.flights conducted on the Eastern Shore of Maryland and Delaware in the fall of 2008. Several other instruments participated in the campaign including the Passive Active L-Band System (PALS), the Marshall Airborne Polarimetric Imaging Radiometer (MAPIR), and the Global Positioning System Reflectometer (GPSR). This campaign was the first SMAP Validation Experiment. DBSAR is a multimode radar system developed at NASA/Goddard Space Flight Center that combines state-of-the-art radar technologies, on-board processing, and advances in signal processing techniques in order to enable new remote sensing capabilities applicable to Earth science and planetary applications [l]. The instrument can be configured to operate in scatterometer, Synthetic Aperture Radar (SAR), or altimeter mode. The system builds upon the L-band Imaging Scatterometer (LIS) developed as part of the RadSTAR program. The radar is a phased array system designed to fly on the NASA P3 aircraft. The instrument consists of a programmable waveform generator, eight transmit/receive (T/R) channels, a microstrip antenna, and a reconfigurable data acquisition and processor system. Each transmit channel incorporates a digital attenuator, and digital phase shifter that enables amplitude and phase modulation on transmit. The attenuators, phase shifters, and calibration switches are digitally controlled by the radar control card (RCC) on a pulse by pulse basis. The antenna is a corporate fed microstrip patch-array centered at 1.26 GHz with a 20 MHz bandwidth. Although only one feed is used with the present configuration, a provision was made for separate corporate feeds for vertical and horizontal polarization. System upgrades to dual polarization are currently under way. The DBSAR processor is a reconfigurable data acquisition and processor system capable of real-time, high-speed data processing. DBSAR uses an FPGA-based architecture to implement digitally down-conversion, in-phase and quadrature (I/Q) demodulation, and subsequent radar specific algorithms. The core of the processor board consists of an analog-to-digital (AID) section, three Altera Stratix field programmable gate arrays (FPGAs), an ARM microcontroller, several memory devices, and an Ethernet interface. The processor also interfaces with a navigation board consisting of a GPS and a MEMS gyro. The processor has been configured to operate in scatterometer, Synthetic Aperture Radar (SAR), and altimeter modes. All the modes are based on digital beamforming which is a digital process that generates the far-field beam patterns at various scan angles from voltages sampled in the antenna array. This technique allows steering the received beam and controlling its beam-width and side-lobe. Several beamforming techniques can be implemented each characterized by unique strengths and weaknesses, and each applicable to different measurement scenarios. In Scatterometer mode, the radar is capable to.generate a wide beam or scan a narrow beam on transmit, and to steer the received beam on processing while controlling its beamwidth and side-lobe level. Table I lists some important radar characteristics

Rincon, Rafael F.↗

Automated Fitting of a Semi-empirical Multiphase Equation of State for Carbon

The equation of state (EOS) of carbon is important in high explosive, geophysical, and inertial confinement fusion applications. Within the semi-empirical Sesame framework, the EOS of each phase is represented by a sum of cold, vibrational, and thermal electronic Helmholtz free energy contributions. Each phase has ~5-10 independent parameters that are adjusted to reproduce single-phase data (e.g., thermal expansion, isothermal compression) as well as experimentally- and computationally- derived phase boundaries. Manual calibration of the full multiphase EOS is arduous. We present our progress in development of automated EOS parameterization based on minimization of an objective function. Here, this function encodes deviation of model EOS results from experimental/computational benchmarks. Optimization is implemented as a combination of global (particle swarm) and local optimization techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Incorporating dynamic recrystallization into a crystal plasticity model for high-temperature deformation of Ti-6Al-4V

During hot deformation of (α + β) titanium alloys, the simultaneous action of strain and temperature in the (α + β) regime facilitates dynamic recovery, dynamic recrystallization (DRX), and phase transformations via non-equilibrium paths. DRX is manifested in the form of fine recrystallized α or β grains. Here, in the present study, a two-phase crystal plasticity finite element framework (CP-DRX) has been developed which incorporates DRX kinetics into the crystal plasticity (CP) model to predict the flow characteristics of Ti-6Al-4V alloys during thermo-mechanical processing. The CP slip system parameters, as well as elastic properties from both α and β phases of Ti, are calibrated for different strain rate conditions. An EBSD-informed two-phase microstructure representation has been utilized in the CP-DRX framework to explore the time-dependent evolution of DRX microstructure and crystal orientation for different strain rate conditions. The proposed CP-DRX can capture the evolution of crystal orientation and plastic flow stress–strain response of polycrystalline Ti-6Al-4V during the deformation process. Furthermore, the proposed model is able to capture the softening behavior, observed in average stress–strain response from experiments performed using a Gleeble thermomechanical simulator and predict the recrystallization texture.

(α+ β)-Titanium (Ti) Alloys↗

Utilizing integrated neutron diffraction and elastoplastic self-consistent crystal plasticity model to quantitatively assess the strengthening mechanism in Al–12.5Ce and Al–12.5Ce–0.4Mg alloys

An integrated in-situ neutron diffraction and elastic plastic self-consistent crystal plasticity (EPSC-CP) modeling scheme is performed on a binary Al–12Ce alloy and a ternary Al–12Ce–0.4Mg alloys. Using this scheme, the constitutive parameters, i.e. elastic constants and slip system parameters of individual phases can be calibrated which can be used in microstructure-based CP models to predict materials performance. From this study, it is shown that the elastic constants of Al 11 Ce 3 intermetallics calculated from density function theory calculation in the literature are rather accurate. When applied to the EPSC-CP model, the lattice strains of both the binary and ternary alloys are correctly predicted as compared with experiments, and large lattice strain differences between Al (100) plane and Al 11 Ce 3 (010) plane are demonstrated. The slip system parameters calibrated by the scheme shows that the addition of 0.4 wt% Mg in the alloy has little influence on the critical resolved shear stress of initial dislocation glide in the Al matrix which caused plastic yield in the material. This can be explained by the very dilute Mg solute content in the Al solid solution, causing large spacing of Al–Mg lattice misfit sites and little impact on resistance of dislocation glide at initial yield. The 0.4 wt% Mg addition, on the other hand, has a large influence on the hardening term in the slip system parameters, indicating those Al–Mg misfit sites do help dislocation accumulation during the deformation. The impact of dilute Mg addition on the Al slip system parameters is also reflected in the flow behavior of the ternary alloy: little impact on the yield stress, but a large impact on working hardening and tensile strength of the materials which is consistent with the literature.

36 MATERIALS SCIENCE↗

ATS-6 - Radio Beacon Experiment: The first years

The Radio Beacon Experiment aboard Applications Technology Satellite-6 (ATS-6) is designed to measure the total electron content and the ionospheric electron content between the satellite and ground. The spaceborne beacon transmits signals on frequencies of 40, 140, and 360 MHz with amplitude modulations of 1 MHz and/or 0.1 MHz for the measurement of modulation phase, Faraday rotation, and amplitude. The modulation phase delays are calibrated in the satellite and in the ground equipment, and the polarization of the emitted signals are predetermined by standard antenna range techniques. The design of the ATS-6 receiver in Boulder, Colorado, is discussed. The antennae are of the short backfire type described by Ehrenspeck (1967), with nominal gains of 13, 19, and 22 dB at 40, 140, and 360 MHz, respectively. Data recording and overall supervision of the receiver is carried out by a 16-bit minicomputer with 8 k of memory. Overall performance of the system is satisfactory. Sample data on the monthly median hourly values of the total electron content, plasmospheric content, and shape factor show distinct seasonal and diurnal variations.

Davies, K.↗