Search NASA⌕ Search

SEARCH · Search NASA

Results for “physical samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Smart Scattering Scanning Near-Field Optical Microscopy

Scattering scanning near-field optical microscopy (s-SNOM) provides spectroscopic imaging from molecular to quantum materials with few nanometer deep subdiffraction limited spatial resolution. However, in its conventional implementation s-SNOM is slow to effectively acquire a series of spatio-spectral images, especially with large fields of view. This problem is further exacerbated for weak resonance contrast or when using light sources with limited spectral irradiance. Indeed, the generally limited signal-to-noise ratio prevents sampling a weak signal at the Nyquist sampling rate. Here, we demonstrate how acquisition time and sampling rate can be significantly reduced by using compressed sampling, matrix completion, and adaptive random sampling, while maintaining or even enhancing the physical or chemical image content. We use fully sampled real data sets of molecular, biological, and quantum materials as ground-truth physical data and show how deep under-sampling with a corresponding reduction of acquisition time by 1 order of magnitude or more retains the core s-SNOM image information. We demonstrate that a sampling rate of up to 6× smaller than the Nyquist criterion can be applied, which would provide a 30-fold reduction in the data required under typical experimental conditions. Furthermore, our smart s-SNOM approach is generally applicable and provides systematic full spatio-spectral s-SNOM imaging with a large field of view at high spectral resolution and reduced acquisition time.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coal Ash Beneficial Use at Savannah River Site

The Savannah River Site (SRS) has over 1.4 million cubic meters of coal ash and coal fines left over from coal-burning power plants that operated on site. Currently, the coal ash must be disposed of in an approved landfill or the coal ash-containing basins must be closed in place (i.e. consolidation, appropriate cover and liner system). Potential beneficial uses of the coal ash include geotechnical fill, such as backfill needed in the closure cap of the Z-area Saltstone Disposal Units (SDU), and use in cementitious material applications like thermal beneficiation or cement kiln feed, thereby reducing the environmental footprint of SRS. In this study, samples of coal ash from SRS were obtained and characterized for chemical and physical properties. Coal ash samples did not leach sulfates or heavy metals, so the coal ash is a candidate for geotechnical fill use. The samples also did not increase the acidity of the leachate during leaching tests, so it would not be detrimental to use as geotechnical fill near cementitious materials. The composition and energy potential of the coal ash makes it favorable for use as feed for external/off-site cement kilns or thermal beneficiation plants

01 COAL, LIGNITE, AND PEAT↗

VULCAN temperature dataset for SMC data challenge

The VULCAN Beamline dataset provides the sample measurement, where temperatures is recorded in two physically different places on the sample. These are held in two different hdf5 groups in the data file.

42 ENGINEERING↗

NASA Curation Preparation for Ryugu Sample Returned by JAXA's Hayabusa2 Mission

The NASA OSIRIS-REx and JAXA Hayabusa2 missions to near-Earth asteroids Bennu and Ryugu share similar mission goals of understanding the origins of primitive, organic-rich asteroids. Under an agreement between JAXA and NASA, there is an on-going and productive collaboration between science teams of Hayabusa2 and OSIRIS-REx missions. Under this agreement, a portion of each of the returned sample masses will be exchanged between the agencies and the scientific results of their study will be shared. NASA’s portion of the returned Hayabusa2 sample, consisting of 10% of the returned mass, will be jointly separated by NASA and JAXA. The sample will be legally and physically transferred to NASA’s dedicated Hayabusa2 curation facility at Johnson Space Center (JSC) no later than one year after the return of the Hayabusa2 sample to Earth (December 2020). The JSC Hayabusa2 curation cleanroom facility design has now been completed. In the same manner, JAXA will receive 0.5% of the total returned OSIRIS-REx sample (minimum required sample to return 60 g, maximum sample return capacity of 2 kg) from the rest of the specimen. No later than one year after the return of the OSIRIS-REx sample to Earth (September 2023), legal, physical, and permanent custody of this sample subset will be transferred to JAXA, and the sample subset will be brought to JAXA’s Extraterrestrial Sample Curation Center (ESCuC) at Institute of Space and Astronautical Science, Sagamihara City Japan.

Nakamura-Messenger, Keiko↗

Double sided measurements and associated error bars for planar samples or subassemblies

Many of the high energy density (HED) experiments use targets with planar components usually in a multilayer stack as the physics package which is at the heart of the experiment. The physics package contains the sample part under study as well as other components as shown in Fig. 1, that when exposed to the laser drive applies pressure onto or shock the main component to take it to the desired state in the phase diagram. These other components may include the ablator, pusher, x-ray pre-heat shield, window or other special components. The components are usually glued together. Currently, experiments on NIF and Omega in the Dynamic Materials campaign use several platforms such as Diffraction, EOS and Strength (Ref 1-3) which all use such planar stack physics packages.

42 ENGINEERING↗

P- and S-Wave velocity and Indirect Tensile Measurements for Alluvium in Support of the Source Physics Experiments

Mechanical properties on alluvium blocks and core samples were determined to support the Source Physics Experiment Dry Alluvium Geology experimental series. Because material was not available directly from the experimental location, the alluvium blocks and core samples are intended to serve as surrogate material . P - and S - wave velocity was measured on cubes cut from the alluvium blocks and core with the intention to study variation from water content and measured direction (material anisotropy). Indirect tensile tests were conducted dry and with moisture ranging from 6 to 9.1%. For the range of water content tested, increasing moisture level resulted in slower P - and S - wave velocities. P - and S - wave variability is less influenced by material heterogeneity than moisture content. P - wave velocity ranges from 629 m/s to 2599 m/s and S - wave velocity ranges from 288 m/s to 1200 m/s. Counter to the velocity measurement findings, material variability on indirect tensile strength has a greater effect than moisture content. Compared to dry strength and at moisture levels from 6 to 9% the block's tensile strength was lowered by at least a factor of 5. Indirect tensile strength for the first block averaged 0.35 MPa and 0.25 MPa for dry and 8.9% moisture respectively. For the second block indirect tensile strength averaged 0.05 MPa for both dry and 6.4% moisture.

36 MATERIALS SCIENCE↗

The Atacama Cosmology Telescope: Physical Properties and Purity of a Galaxy Cluster Sample Selected Via the Sunyaev-Zel'Dovich Effect

We present optical and X-ray properties for the first confirmed galaxy cluster sample selected by the Sunyaev-Zel'dovich Effect from 148 GHz maps over 455 square degrees of sky made with the Atacama Cosmology Telescope. These maps. coupled with multi-band imaging on 4-meter-class optical telescopes, have yielded a sample of 23 galaxy clusters with redshifts between 0.118 and 1.066. Of these 23 clusters, 10 are newly discovered. The selection of this sample is approximately mass limited and essentially independent of redshift. We provide optical positions, images, redshifts and X-ray fluxes and luminosities for the full sample, and X-ray temperatures of an important subset. The mass limit of the full sample is around 8.0 x 10(exp 14) Stellar Mass. with a number distribution that peaks around a redshift of 0.4. For the 10 highest significance SZE-selected cluster candidates, all of which are optically confirmed, the mass threshold is 1 x 10(exp 15) Stellar Mass and the redshift range is 0.167 to 1.066. Archival observations from Chandra, XMM-Newton. and ROSAT provide X-ray luminosities and temperatures that are broadly consistent with this mass threshold. Our optical follow-up procedure also allowed us to assess the purity of the ACT cluster sample. Eighty (one hundred) percent of the 148 GHz candidates with signal-to-noise ratios greater than 5.1 (5.7) are confirmed as massive clusters. The reported sample represents one of the largest SZE-selected sample of massive clusters over all redshifts within a cosmologically-significant survey volume, which will enable cosmological studies as well as future studies on the evolution, morphology, and stellar populations in the most massive clusters in the Universe.

Menanteau, Felipe↗

Investigating Astromaterials Curation Applications for Dexterous Robotic Arms

The Astromaterials Acquisition and Curation office at NASA Johnson Space Center is currently investigating tools and methods that will enable the curation of future astromaterials collections. Size and temperature constraints for astromaterials to be collected by current and future proposed missions will require the development of new robotic sample and tool handling capabilities. NASA Curation has investigated the application of robot arms in the past, and robotic 3-axis micromanipulators are currently in use for small particle curation in the Stardust and Cosmic Dust laboratories. While 3-axis micromanipulators have been extremely successful for activities involving the transfer of isolated particles in the 5-20 micron range (e.g. from microscope slide to epoxy bullet tip, beryllium SEM disk), their limited ranges of motion and lack of yaw, pitch, and roll degrees of freedom restrict their utility in other applications. For instance, curators removing particles from cosmic dust collectors by hand often employ scooping and rotating motions to successfully free trapped particles from the silicone oil coatings. Similar scooping and rotating motions are also employed when isolating a specific particle of interest from an aliquot of crushed meteorite. While cosmic dust curators have been remarkably successful with these kinds of particle manipulations using handheld tools, operator fatigue limits the number of particles that can be removed during a given extraction session. The challenges for curation of small particles will be exacerbated by mission requirements that samples be processed in N2 sample cabinets (i.e. gloveboxes). We have been investigating the use of compact robot arms to facilitate sample handling within gloveboxes. Six-axis robot arms potentially have applications beyond small particle manipulation. For instance, future sample return missions may involve biologically sensitive astromaterials that can be easily compromised by physical interaction with a curator; other potential future returned samples may require cryogenic curation. Robot arms may be combined with high resolution cameras within a sample cabinet and controlled remotely by curator. Sophisticated robot arm and hand combination systems can be programmed to mimic the movements of a curator wearing a data glove; successful implementation of such a system may ultimately allow a curator to virtually operate in a nitrogen, cryogenic, or biologically sensitive environment with dexterity comparable to that of a curator physically handling samples in a glove box.

Snead, C. J.↗

Lunar bulk sample trace element contents and KREEP.

The geochemical coherence of KREEP-related labile (Cl) and refractory (F, K, P, and REE) elements in lunar soils is shown to provide some insights into the evolution of the lunar samples studied. Thus, this coherence may help define the physical conditions under which the samples evolved. These conditions range from high temperatures and relatively open systems for mare basalts to moderate temperatures and closed systems for KREEP-related material. The water leachable Cl may be the residuum of the Cl-containing phase with which mare and KREEP source material equilibrated.

Reed, G. W., Jr.↗

Depth profiling and standardization from the back side of a sample for accurate analyses: Emphasis on quantifying low‐fluence, shallow implants in diamond‐like carbon

Rationale Back‐side thinning of wafers is used to eliminate issues with transient sputtering when analyzing near‐surface element distributions. Precise and accurate calibrated implants are created by including a standard reference material during the implantation. Combining these methods allows accurate analysis of low‐fluence, shallow features even if matrix effects are a concern. Methods Implanted Na (<2.0 × 10 11 ions/cm 2 , peaking <50 nm) in diamond‐like carbon (DLC) film on silicon (solar wind returned by NASA's Genesis mission) was prepared for measurement as follows. Implanted surfaces of samples were epoxied to wafers and back‐side‐thinned using physical or chemical methods. Thinned samples were then implanted with reference ions for accurate quantification of the solar wind implant. Analyses used a CAMECA IMS 7f‐GEO SIMS in depth‐profiling mode. Results Back‐side‐implanted reference ions reduced the need to change sample mounts or stage position and could be spatially separated from the solar wind implant even when measuring monoisotopic ions. Matrix effects in DLC were mitigated and the need to find an identical piece of DLC for a reference implant was eliminated. Accuracy was only limited by the back‐side technique itself. Conclusions Combining back‐side depth profiling with back‐side‐implanted internal standards aides quantification of shallow mono‐ and polyisotopic implants. This technique helps mitigate matrix effects and keeps measurement conditions consistent. Depth profile acquisition times are longer, but if sample matrices are homogeneous, procedural changes can decrease measurement times.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Waveform resampling with LMN method

In this article, resampling is a common technique applied in digital signal processing. Based on the Fast Fourier Transformation (FFT), we apply an optimization called here the LMN method to achieve fast and robust re-sampling. In addition to performance comparisons with some other popular methods, we illustrate the effectiveness of this LMN method in a particle physics experiment: re-sampling of waveforms from Liquid Argon Time Projection Chambers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Determination of Aromatic Ring Number Using Multi-Channel Deep UV Native Fluorescence

The in situ detection of organic material on an extraterrestrial surface requires both effective means of searching a relatively large surface area or volume for possible organic carbon, and a more specific means of identifying and quantifying compounds in indicated samples. Fluorescence spectroscopy fits the first requirement well, as it can be carried out rapidly, with minimal or no physical contact with the sample, and with sensitivity unmatched by any other organic analytical technique. Aromatic organic compounds with know fluorescence signatures have been identified in several extraterrestrial samples, including carbonaceous chondrites, interplanetary dust particles, and Martian meteorites. The compound distributions vary among these sources, however, with clear differences in relative abundances by number of aromatic rings and by degree of alkylation. This relative abundance information, therefore, can be used to infer the source of organic material detected on a planetary surface.

Bhartia, R.↗

Apollo 14 rock samples

Petrographic descriptions of all Apollo 14 samples larger than 1 cm in any dimension are presented. The sample description format consists of: (1) an introductory section which includes information on lunar sample location, orientation, and return containers, (2) a section on physical characteristics, which contains the sample mass, dimensions, and a brief description; (3) surface features, including zap pits, cavities, and fractures as seen in binocular view; (4) petrographic description, consisting of a binocular description and, if possible, a thin section description; and (5) a discussion of literature relevant to sample petrology is included for samples which have previously been examined by the scientific community.

Carlson, I. C.↗

Initial Results from the Bloomsburg University Goniometer Laboratory

The Bloomsburg University Goniometer Laboratory (B.U.G. Lab) consists of three systems for studying the photometric properties of samples. The primary system is an automated goniometer capable of measuring the entire bi-directional reflectance distribution function (BRDF) of samples. Secondary systems include a reflectance spectrometer and digital video camera with macro zoom lens for characterizing and documenting other physical properties of measured samples. Works completed or in progress include the characterization of the BRDF of calibration surfaces for the 2003 Mars Exploration Rovers (MER03), Martian analog soils including JSC-Mars-1, and tests of photometric models.

Shepard, M. K.↗

Electromagnetic shower reconstruction and energy validation with Michel electrons and π 0 samples for the deep-learning-based analyses in MicroBooNE

This article presents the reconstruction of the electromagnetic activity from electrons and photons (showers) used in the MicroBooNE deep learning-based low energy electron search. The reconstruction algorithm uses a combination of traditional and deep learning-based techniques to estimate shower energies. We validate these predictions using two v μ -sourced data samples: charged/neutral current interactions with final state neutral pions and charged current interactions in which the muon stops and decays within the detector producing a Michel electron. Both the neutral pion sample and Michel electron sample demonstrate agreement between data and simulation. Finally, the absolute shower energy scale is shown to be consistent with the relevant physical constant of each sample: the neutral pion mass peak and the Michel energy cutoff.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Plutonium-238 Loadout Calorimeter Return To Service

The calorimeter in the transfer area in Building 7920 at the US Department of Energy’s Oak Ridge National Laboratory is used to measure the amount of 238 Pu in the Plutonium Heat Source Oxide. The calorimetry measurement is taken after the oxide is packaged in an ORISC (Oak Ridge Inner Shipping Capsule)/FSO (Fuel Storage Outer) assembly before loading into the Containment Vessel and shipping container. The equipment is used in three specific configurations: zero measurement (nothing in the sample cup), FSO measurement (actual measurement of 238 Pu), and reference calibration measurement (using the reference FSO as a known heat source). System checks were performed in July 2023 in preparation for scheduled material loadout. During these checks, personnel discovered that the reference FSO had experienced an electrical short in the heater cable and was no longer functional. The calorimeter was in the reference calibration measurement configuration at this time. Facility management was notified when the damage was discovered. The data from the Yokogawa recorder were pulled and analyzed for a span of time between September 2022 and July 2023. An unusual spike was found in the sample cup temperature data that started on October 19, 2022, and ended on October 20, 2022. The sample cup reached a temperature of 191.1°C. The maximum allowable temperature for the calorimeter thermopile to reach is 220°C based on the manufacturer statement provided in Appendix B of this report [1]. The calorimeter thermopile and the sample cup thermocouple are physically close to each other; therefore, the data suggest that the calorimeter itself never saw a temperature in excess of 191.1°C. Physical damage present on the cable, tape, and insulation suggests that the temperature reached a higher value in some locations within the sample cup than the data shows. Because of this discrepancy, testing of the calorimeter was required to confirm that the calorimeter is functioning the same as it was before the electrical short. The intent of this report is to assess the functionality of the calorimeter and determine if it is acceptable to use for 238 Pu loadout material measurement. Testing showed that the calorimeter is functionally equivalent to the initial calibration that was performed in the summer of 2021, and thus, the calorimeter was cleared to be used for its intended purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low Cost, High Volume, Carbon Fiber Precursor for Plasma Oxidation

Light weighting with carbon fiber is critical to improving the energy efficiency of wind turbines, airplanes, and automobiles, but the high cost of carbon fiber continues to limit market growth and applications. Half of this cost is in the raw materials. For the carbon fiber market to reach the next level of adoption, the cost of both the raw materials and conversion must be reduced. This project considered the combination of low-cost, textile-grade precursors combined with the increased efficiency of plasma oxidation to greatly reduce the cost of carbon fiber. The primary objective of this project was to make industrial-grade carbon fiber (550 ksi tensile strength, 35 Msi tensile modulus) from textile-grade PAN precursors, something that cannot be achieved with conventional oxidation and to date has not been achieved with any technology. To accomplish this, the project team iteratively optimized the process conditions in the plasma oxidation and carbonization stages to maximize the tensile properties of the resultant carbon fibers. This involved implementing experimental designs for both stages, whereby process conditions (e.g. temperature) were varied and correlated to fiber properties. Samples of oxidized PAN fibers (OPFs) were prepared using a small pilot-scale plasma oxidation oven at 4XTechnologies (4XT). The thermal, chemical, and physical properties of OPF samples were analyzed by the University of Tennessee (UTK) and Oak Ridge National Laboratory (ORNL). The OPF samples were then converted to carbon fiber by subsequent low- and high-temperature carbonization using a lab-scale furnace at ORNL. The resultant carbon fibers were tested for tensile strength also at ORNL, and the results were fed back into the experimental design. Of the hundreds of carbon fiber samples produced over the course of the project, the best sample had an average break strength of 479 ksi and modulus of 33 Msi. While the best tensile properties achieved fell short of the final project targets of 550 ksi for break strength and 35 Msi for modulus, the team demonstrated the potential to produce industrial-grade carbon fiber using textile-grade precursors. The best performing fiber samples had tensile properties that are 87% of the goal for tensile strength and 94% of the goal for tensile modulus. With additional optimization work, it is likely that the targets could be achieved, since only a fraction of the process parameter space was explored during this project. 4XT and its affiliate (4M) have already secured funding through private equity, and there is a CRADA (Cooperative Research and Development Agreement) project currently underway with the Carbon Fiber Technology Center (CFTF) at ORNL to continue this research. Additionally, while not an original goal of the project, the carbon fibers for most samples had diameters >8.5μm. This is considerably larger than commercially available carbon fiber products, which can impart unique properties to the composites (e.g. increased compressive strength) and decrease manufacturing costs even further. Moreover, these fibers were oxidized with plasma oxidation using residence times ranging <60mins, which would be considered fast for normal diameter fibers, but it is as much as 5x faster when factoring in the diameter of the fibers.

36 MATERIALS SCIENCE↗