Search NASA⌕ Search

SEARCH · Search NASA

Results for “plasma instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

A digital holography ex situ measurement characterization of plasma-exposed surface erosion from an electrothermal arc source

Digital holography has been proposed to fulfill a need for an imaging diagnostic capable of in situ monitoring of surface erosion caused by plasma–material interaction in nuclear fusion devices. A digital holography diagnostic for 3D surface erosion measurement has been developed at Oak Ridge National Laboratory with the goal of deployment on a plasma device. A proof-of-concept in situ demonstration is planned which would involve measurement of plasma erosion on targets exposed to an electrothermal arc source. This work presents the results of an ex situ characterization of the capability and limitations of holographic imaging of targets exposed to the arc source. Targets were designed to provide a fiducial for comparison of deformed and unaffected areas. The results indicated that the average net erosion was ~150 nm/plasma exposure, which is expected to be within the diagnostic’s measurement capacity. Surface roughness averages determined by holographic image analysis showed good agreement with measurements taken with a profilometer. Finally, the limit of the holography diagnostic’s x–y spatial resolution was characterized by comparison with scanning electron microscope imaging.

47 OTHER INSTRUMENTATION↗

Inference of molecular divertor density from filtered camera analysis of molecularly induced Balmer line emission during detachment in JET L-mode plasmas

Here a previously presented Monte Carlo method for estimating local plasma conditions in 2D based on intensity ratios of deuterium Balmer D α , D γ and D ε lines was amended to consider also the D α and D γ emission contributions arising from molecular processes. The obtained estimates were used to infer the molecular divertor density with the help of the molecular databases of EIRENE. The method was benchmarked against EDGE2D-EIRENE simulations and observed to reproduce the molecularly induced emission fractions and the molecular divertor densities primarily within 25% of the references. Experimental analysis of a JET L-mode density scan suggested molecularly induced D α and D γ contributions of up to 60–70% and 20%, respectively, during the process of detachment. The independent estimates of the molecular divertor density inferred from the obtained molecularly induced D α and D γ intensities agree within uncertainties with each other. Both estimates show the molecular density increasing up to approximately 1.0–2.0 x 10 20 m -3 at the outer strike point in deep detachment with its ratio to the local electron density agreeing with EDGE2D-EIRENE predictions within the scatter of the experimental data.

interferometry↗

Toward an integrated multi-gigahertz ionizing particle diagnostic

Needs arising at both current and future accelerator facilities call for the development of radiation-hardened position-sensing diagnostics that can operate with multi-GHz repetition rates. Such instruments are likely to also have applications in the diagnosis of rapid plasma behavior. Here, building on the recent work of our Advanced Accelerator Diagnostics Collaboration, we are exploring the development of integrated multi-GHz ionizing particle detection systems based on chemical-vapor deposition diamond sensors, with the initial goal of producing a quadrant detector that can determine the intensity and centroid position of a particle beam at a repetition rate between 5 and 10 GHz. Results from our initial high-speed characterization work are presented, including those from a single-channel sensor with a GHz response. Approaches to achieving multi-GHz (5–10 GHz) rate capability, including the design of a dedicated Application Specific Integrated Circuit and the use of 3D RF-solver computer aided design software, are presented and discussed in more detail. 3D RF simulations suggest clean pulses of duration less than 250 ps (FWHM less than 125 ps) can be achieved with the approaches developed by this work.

43 PARTICLE ACCELERATORS↗

Measurements of ion velocity distributions in a large scale laser-produced plasma

Laser-produced plasma velocity distributions are an important, but difficult quantity to measure. In this work, we present a noninvasive technique for measuring individual charge state velocity distributions of laser-produced plasmas using a high temporal and spectral resolution monochromator. The novel application of this technique is its ability to detect particles up to seven meters from their inception (significantly larger than most laboratory plasma astrophysics experiments, which take place at or below the millimeter scale). The design and assembly of this diagnostic is discussed in terms of maximizing the signal to noise ratio, maximizing the spatial and temporal resolution, and other potential use cases. The analysis and results of this diagnostic are demonstrated by directly measuring the time-of-flight velocity of all ion charge states in a laser produced carbon plasma.

47 OTHER INSTRUMENTATION↗

Compact spectroscopy of keV to MeV X-rays from a laser wakefield accelerator

We reconstruct spectra of secondary X-rays from a tunable 250–350 MeV laser wakefield electron accelerator from single-shot X-ray depth-energy measurements in a compact (7.5 × 7.5 × 15 cm), modular X-ray calorimeter made of alternating layers of absorbing materials and imaging plates. X-rays range from few-keV betatron to few-MeV inverse Compton to > 100 MeV bremsstrahlung emission, and are characterized both individually and in mixtures. Geant4 simulations of energy deposition of single-energy X-rays in the stack generate an energy-vs-depth response matrix for a given stack configuration. An iterative reconstruction algorithm based on analytic models of betatron, inverse Compton and bremsstrahlung photon energy distributions then unfolds X-ray spectra, typically within a minute. We discuss uncertainties, limitations and extensions of both measurement and reconstruction methods.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Broadband coherent XUV light from e − / e + microbunching in an intense laser pulse

Attosecond pulses of coherent extreme ultraviolet (XUV) light are instrumental for investigating subatomic dynamics and can be produced using a free-electron laser (FEL). It has been suggested that an optical FEL, which employs a laser pulse in place of a conventional undulator, could enable a dramatically more compact implementation of such a light source. Yet, the high electron density and subsequent high emittance implied by an optical FEL makes this concept challenging to realize with an electron beam. There has been impressive progress in recent years producing collimated dense and relativistic beams of electrons and positrons in the laboratory. As we demonstrate here, the inherent stability of a quasi-neutral electron-positron beam mitigates Coulomb expansion, and renders it a promising alternative source of coherent light. Specifically, we show via computer simulations that broadband coherent light in the XUV domain, which takes the form of 8-as pulses at 92-as intervals, can be generated by microbunching of relativistic electrons and positrons in a laser pulse. This process occurs over a sub-millimeter length scale, enabling the development of light sources which are orders-of-magnitude more compact than existing sources, with potential applications in physics, chemistry, biology, and industry.

47 OTHER INSTRUMENTATION↗

On Alfvénic turbulence of solar wind streams observed by Solar Orbiter during March 2022 perihelion and their source regions

It has been recently accepted that the standard classification of the solar wind solely according to flow speed is outdated, and particular interest has been devoted to the study of the origin and evolution of so-called Alfvénic slow solar wind streams and to what extent such streams resemble or differ from fast wind. In March 2022, Solar Orbiter completed its first nominal phase perihelion passage. During this interval, it observed several Alfvénic streams, allowing for characterization of fluctuations in three slow wind intervals (AS1-AS3) and comparison with a fast wind stream (F) at almost the same heliocentric distance. This work makes use of Solar Orbiter plasma parameters from the Solar Wind Analyzer (SWA) and magnetic field measurements from the magnetometer (MAG). The magnetic connectivity to the solar sources of selected solar wind intervals was reconstructed using a ballistic extrapolation based on measured solar wind speed down to the (spherical) source surface at 2.5 R s below which a potential field extrapolation was used to map back to the Sun. The source regions were identified using SDO/AIA observations. A spectral analysis of in situ measured magnetic field and velocity fluctuations was performed to characterize correlations, Alfvénicity, normalized cross-helicity, and residual energy in the frequency domain as well as intermittency of the fluctuations and spectral energy transfer rate estimated via mixed third-order moments. A machine learning technique was used to separate proton core, proton beam, and alpha particles and to study v − b correlations for the different ion populations in order to evaluate the role played by each population in determining the Alfvénic content of solar wind fluctuations. The comparison between fast wind and Alfvénic slow wind intervals highlights the differences between the two solar wind regimes: The fast wind is characterized by larger amplitude fluctuations, and magnetic and velocity fluctuations are closer to equipartition of energy. In fact the Alfvénic slow wind streams appear to be on a spectrum of wind types, with AS1, originating from open field lines neighboring active regions and displaying similarities with the fast wind in terms of fluctuation amplitude and turbulence characteristics, but not with respect to the alpha particles and proton beams. The other two slow streams differed both in their sources as well as plasma characteristics, with AS2 coming from the expansion of a narrow coronal hole corridor and AS3 from a region straddling a pseudostreamer. The latter displayed the coldest and highest density but the slowest stream with the smallest fluctuation amplitude and greatest magnetic energy excess. It also showed the largest scatter in proton beam speeds and the greatest difference in speed between proton beam and alpha particles. This study shows how the old fast–slow solar wind dichotomy, already called into question by the observations of slower Alfvénic solar wind streams, should further be refined, as the Alfvénic slow wind, originating in different solar wind regions, show significant differences in density, temperature, and proton and alpha-particle properties in the inner heliosphere. The observations presented here provide the starting point for a better understanding of the origin and evolution of different solar wind streams as well as the evolving turbulence contained within.

magnetohydrodynamics (MHD)↗

Holistic Numerical Calibration of the iMESA Electrostatic Analyzer

A drifted Maxwellian velocity distribution is the most common model used to interpret the data from low-energy charged-particle instruments onboard spacecraft that are used to investigate the ambient plasma environment in the low Earth orbit (LEO). An original method is presented for determining the flow parameters (density, temperature, and flow energy) of such a distribution from the output of the integrated miniaturized electrostatic analyzer, which has been successfully flown on several LEO missions. Rather than attempting to deconvolve from the on-orbit data the analyzer’s response to an ideal, monoenergetic input, numerical simulation is used to predict and parameterize the response of the device to an input distribution that includes an isotropic, non-zero temperature, yielding a straightforward method for extracting the flow parameters from the spacecraft data. The method is computationally simple enough to be incorporated into a robust algorithm suitable for rapid batch processing or real-time analysis of data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Online charge measurement for petawatt laser-driven ion acceleration

Laser-driven ion beams have gained considerable attention for their potential use in multidisciplinary research and technology. Preclinical studies into their radiobiological effectiveness have established the prospect of using laser-driven ion beams for radiotherapy. In particular, research into the beneficial effects of ultrahigh instantaneous dose rates is enabled by the high ion bunch charge and uniquely short bunch lengths present for laser-driven ion beams. Such studies require reliable, online dosimetry methods to monitor the bunch charge for every laser shot to ensure that the prescribed dose is accurately applied to the biological sample. In this paper, we present the first successful use of an Integrating Current Transformer (ICT) for laser-driven ion accelerators. This is a noninvasive diagnostic to measure the charge of the accelerated ion bunch. It enables online estimates of the applied dose in radiobiological experiments and facilitates ion beam tuning, in particular, optimization of the laser ion source, and alignment of the proton transport beamline. We present the ICT implementation and the correlation with other diagnostics, such as radiochromic films, a Thomson parabola spectrometer, and a scintillator.

47 OTHER INSTRUMENTATION↗

Non-inductive plasma vertical position measurement for the 1056 s discharge on EAST

Vertical position stability plays a crucial role in maintaining safe and reliable plasma operation for long-pulse fusion devices. In general, the vertical position is measured by using inductive magnetic coils installed inside the vacuum vessel; however, the integration drift effects are inherent for steady-state or long-pulse plasma operation. Further, developing a non-magnetic approach provides a fusion reactor-relevant steady-state solution that avoids the negative impact of integration drift. In this paper, we compare the non-inductively determined vertical position achieved by line-integrated interferometer and polarimeter measurements to that employing an inductive flux loop for a 1056 s discharge recently achieved on EAST (Experimental Advanced Superconducting Tokamak). Experimental results show that the non-inductive measurement is more robust than flux loops after 300 s if the integrator is not reset to suppress integrator drift. Real-time vertical position control using the non-inductive system is proposed for the next EAST experimental campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design study of an edge current density diagnostic using new high-performance single-channel beam emission spectrometers at DIII-D

A novel Motional Stark Effect spectroscopy system has been designed for application at the DIII-D tokamak. The system is optimized for studies of the poloidal and toroidal magnetic field in the plasma pedestal region with frame rates of up to 10 kHz. Further, light from an existing high-photon-throughput collection lens is analyzed using four single-channel f/2.8 Czerny–Turner spectrometers that use custom-made lens systems instead of mirrors. Each spectrometer has two separate outgoing legs and is operated in a positive grating order, which allows for simultaneous observations of D-alpha and D-beta spectra. Forward modeling using the code FIDASIM shows a radial resolution of the system close to 0.6 cm and sufficiently good spectral resolution when masking the high throughput light collection lens in the horizontal direction to avoid overly strong Doppler broadening of beam emission lines. Moreover, a detailed sensitivity study considering realistic levels of readout and photon noise shows that the poloidal and toroidal magnetic field strengths can be inferred with an uncertainty of less than 1%, which will allow the inference of changes of the plasma current during transient events.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of the Lanthanum hexaboride based plasma source for the large plasma device at UCLA

The Large Plasma Device (LAPD) at UCLA (University of California, Los Angeles) produces an 18 m long, magnetized, quiescent, and uniform plasma at a high repetition rate to enable studies of fundamental plasma physics. Here, we report on a major upgrade to the LAPD plasma source that allows for more robust operation and significant expansion of achievable plasma parameters. The original plasma source made use of a heated barium oxide (BaO) coated nickel sheet as an electron emitter. This source had a number of drawbacks, including a limited range of plasma density (≲4.0 × 10 12 cm −3 ), a limited discharge duration (∼10 ms), and susceptibility to poisoning following oxygen exposure. Further, the new plasma source utilizes a 38 cm diameter lanthanum hexaboride (LaB 6 ) cathode, which has a significantly higher emissivity, allowing for a much larger discharge power density, and is robust to exposure to air. Peak plasma density of up to 3.0 × 10 13 cm −33 in helium gas has been achieved. The typical operating pressure is ∼10 −5 Torr, while dynamic pressure can be achieved through the gas-puffing technique. Discharges as long as 70 ms have been produced, enabling a variety of long-time-scale studies of processes, such as turbulent particle transport. The new source has been in continuous operation for 14 months, having survived air leaks, power outages that led to rapid temperature changes on the cathode and heater, and planned machine openings. We describe the design, construction, and initial operation of this novel new large-area LaB6 plasma source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of an x-ray multilayer mirror for radiography at sub-1-keV photon energies

An x-ray multilayer mirror on a spherical substrate designed for near-normal incidence with a photon energy of ~738 eV (F He α ) was procured and tested. This device is intended to be used for in-flight radiography of the shell in inertial confinement fusion experiments with cryogenic targets on the OMEGA laser at the Laboratory for Laser Energetics. Experiments in self-emission on a small (~10 J) laser system showed that the reflectivity of the mirror is high enough to record an image at laser energies as low as 0.1 J. Furthermore, a second set of tests in backlighting geometry on a larger (kJ)-scale, short-pulse laser yielded usable radiographs with laser energies as low as 40 J with a spatial resolution of ~10 μm.

47 OTHER INSTRUMENTATION↗

Laser cutting apparatus for high energy density and diamond anvil cell science

In this paper, we present a low-cost, high-resolution laser cutting system designed for use in the fabrication of samples for high energy density physics. Such samples are necessarily small but require precision and repeatability, particularly with the recently available high repetition rates possible at modern facilities. The system allows simultaneous laser cutting, using nanosecond near-infrared laser pulses, and optical microscopy so that the cut can be monitored in real time. The capabilities of the system are demonstrated on a range of materials for both laser-matter interaction targets and components for high pressure diamond anvil cell experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Versatile multi-energy hard x-ray camera to study confined and unconfined fast electron dynamics and anisotropies (Invited)

A powerful and flexible hard x-ray (HXR) camera has been recently installed and tested on the WEST tokamak (CEA, France) in collaboration with the Princeton Plasma Physics Laboratory. The diagnostic is a pinhole camera fielded with a 2D pixel detector equipped with a 1 mm thick CdTe sensor. The novelty of this diagnostic technique is the detector’s capability of adjusting the threshold energy at the pixel level. This innovation provides great flexibility in the energy configuration, allowing simultaneous space, energy, and time resolved x-ray measurements. The novel camera has been used to measure the core radiation from non-Maxwellian (fast) electrons accelerated by Lower Hybrid (LH) waves and also the beam–target emission of tungsten in the divertor region produced by fast electron losses interacting with the target. In addition, anisotropic hard x-ray emission has been detected for the first time at the WEST core and edge plasma, with opposite toroidal intensity trends. Finally, experimental vertical and toroidal HXR profiles have been successfully reproduced with the LH code LUKE.

47 OTHER INSTRUMENTATION↗