Search NASASearch

SEARCH · Search NASA

Results for “point defects”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

152 records · Page 9

AI-Batt (Autonomous Identification of Battery Life Models) [SWR 21-36]

Autonomous Identification of Battery Life Models (AI-Batt) AI-Batt is a MATLAB code base for developing lifetime models for batteries from accelerated aging data. The code base provides many functions for processing, visualizing, and modeling battery aging data, making the data processing, exploration, and modeling workflow substantially faster. These tools are tailored for working with battery aging data sets, which usually consist of many separate time-series for each cell, with many test conditions and possible replicates at each condition, which makes it difficult to simply process or visualize the data set. Complex modeling tasks, such as cross-validation, sensitivity analysis, and uncertainty quantification have been implemented to enable thorough statistical investigation of model predictions. Additionally, several machine-learning algorithms are implemented to autonomously identify suitable models via symbolic regression. Data processing functions automatically cast data from the struct data type, which is commonly used to store experimental data, but is not an acceptable input for most algorithms, to the table data type, which can be easily used as input to any optimization algorithm. Also, the data can be separated into time-invariant and time-variant data tables, which is helpful for exploring the data set as well as developing separate models for time-variant and time-invariant aging mechanisms. For example, in aging tests with constant temperature, temperature is a time-invariant experimental condition. Visualization tools enable plotting of data, model fits, and model simulations possible with single-line function calls, empowering data exploration of complex data sets with both time-varying and time-invariant trends. Plots can be automatically generated for the whole data set, or separated by data group (groups of test replicates) or individual data series. Data points or data series can be automatically colored by the value of a variable with a variety of color maps, and model predictions can also be colored by the value of a fit statistic. Comparisons between data sets and the predictions/simulations of different models on the same data set can be easily plotted as well. Distributions of parameter values from bootstrap resampling can be plotted to visualize the reliability of parameter estimation, or determine any correlations between parameters. Modeling tools handle the complex task of creating and parsing symbolic equations for modeling battery lifetime. Equations are parsed to grab relevant data variables, parameter values, or specified sub-models for input into optimization, evaluation, or simulation functions. Models can be optimized locally (one set of parameters for each data series), bi-level (some parameters shared across the data set), or globally (single set of parameters for all data). Functions implementing symbolic regression algorithms help users to discover effective model equations, even in poorly sampled, high-dimensional data.

Smith, Kandler [National Renewable Energy Lab. (NR

Nuclear Safety [Vol. 16, No. 2, March-April 1975]

Nuclear Safety covers significant developments in the field of nuclear safety. The scope is limited to topics relevant to the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, safety considerations in regard to the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 127 Quality Assurance in the Construction of Nuclear Power Plants by Sidney A. Bernsen, 141 1974 ANS Topical Meeting on Fast Reactor Safety by M. H. Fontana; CONTROL AND INSTRUMENTATION: 150 GBR-4 Protection Systems: Failures and Their Consequences by Peter Burgsmüller, J. J. Dekais, Albert Krähe, Raffaello Pignatelli, and Gottfried Vieider, 162 Standby Emergency Power Systems. Part 2—The Later Plants by E. W. Hagen; PLANT SAFETY FEATURES: 180 Radiotoxic Hazard Measure for Buried Solid Radioactive Waste by J. Hamstra, 190 The Thirteenth AEC Air-Cleaning Conference by D. W. Moeller, D. W. Underhill, and M. W. First, 203 Book Review: Nuclear Criticality Safety; CONSEQUENCES OF EFFLUENT RELEASE: 204 Environmental Radiation Effects of Nuclear Facilities in New York State by M. S. Terpilak and B. L. Jorgensen, 222 Book Review: Thermal Ecology; OPERATING EXPERIENCES: 223 Set-Point Drift in Nuclear Power-Plant Safety-Related Instrumentation Adapted by the Nuclear Safety Staff, 224 Diesel-Generator Operating Experience at Nuclear Power Plants, 227 Summary of Operating U. S. Power Reactors as of Jan. 1, 1975, 232 Selected Safety-Related Occurrences Reported in November and December 1974 Compiled by William R. Casto, 235 Recent Occurrences at Nuclear Reactors and Their Causes Compiled by William R. Casto; CURRENT EVENTS: 243 General Administrative Activities Compiled by Wm. B. Cottrell, 251 Action on Power-Reactor Projects Undergoing Regulatory Review or Consideration Compiled by Wm. B. Cottrell, 266 Action on Nonreactor Projects Undergoing Regulatory Review or Consideration Compiled by Wm. B Cottrell, 268 Proposed Rule Changes as of Jan. 1, 1975; MISCELLANY: 149 Course in Italy on High-Energy Radiation Dosimetry and Protection (Announcement), 250 Course at Northwestern on Safety of Light-Water-Cooled Nuclear Power Plants (Announcement), 266 Symposium of the Combined Effects on the Environment of Radioactive, Chemical, and Thermal Releases from the Nuclear Industry (Announcement), 271 Short Course on Engineering for Extreme Winds and Tornadoes (Announcement), 272 Three 1-Week Courses at MIT on Nuclear Power-Reactor Safety (Announcement), 272 Harvard University Short Courses (Announcement).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Dielectric Spectroscopy Cable NDE for Unequal Aging Over Different Lengths

This Pacific Northwest National Laboratory milestone report assesses the effect of unequal aging over different lengths of cable on dielectric spectroscopy (DS) bulk impedance measurements from the cable end. DS measurements can indicate the remaining useful life of cables; however, most benchmark tests are based on accelerated aging of the entire cable. If only a portion of the cable is exposed to a harsh environment (as is frequently the case), the DS measurement will indicate a significantly less-aged cable than if the entire cable were exposed to a uniform environmental stress. The DS measurement is primarily related to the intrinsic insulation material relative permittivity—typically between 1.5 and 3.0. Insulation aging increases permittivity and, correspondingly, the cable’s overall capacitance measured from the cable end. To judge the health of the overall cable system, operators are primarily interested in the condition of the most severely aged section since that is where a failure is most likely to occur. This can be expressed as the dimensionless relative permittivity of the severely aged section divided by the permittivity of a pristine cable. This relative permittivity is an intrinsic material parameter independent of cable length and can serve as a quantitative indication of the insulation condition. If the relative percentages of cable exposed to a harsh and benign environment are known, the DS measurement of the entire cable length, including both pristine and aged sections, can be compensated to predict the relative permittivity (relative to pristine permittivity) of the most severly aged segment. A test was performed on three 50 ft (16 m) cables with 10%, 50%, and 90% of the cable inside a thermal aging oven. Predictably, the aging effect on the DS response was greatest in the 90% sample, followed by the 50% sample, and then the 10% sample. The more interesting result is the ratio of the aged insulation permittivity to the pristine insulation permittivity. Based on prior work, an end-of-life cable has a value of approximately 1.35. If the relative percentages of pristine and severely aged cable lengths are known, and the total cable-length capacitance of the initial pristine cable and the combined pristine plus aged cable are known, the relative aged permittivity (ratio of aged section permittivity / pristine section permittivity) can be estimated. The relative cable lengths exposed to a harsh environment may be known or estimated based on plant layout drawings or cable reflectometry tests that can locate the oven entry and exit points. The compensation was verified using a lumped-parameter model to predict the aged-segment permittivity e2/e1, where e2 is the aged-segment permittivity and e1 is the pristine-segment permittivity. For all three percentages of aged cable lengths, the ratio was quite similar, as would be expected since all cable segments were exposed to the same aging environment. This ratio of aged permittivity to pristine permittivity can be compared to other damage indicating tests, including elongation at break, to assess cable condition.

ARENA Test Bed

UCB-GLOBES: An open-access mass spectral database of identified and unidentified atmospheric organic compounds

Chemical characterization of atmospheric organic aerosols using gas chromatography with 70 eV electron ionization mass spectrometry (GC/EI-MS) has been used for decades in advancing molecular marker detection and identification, though primarily through suspect screening and/or targeted analyses. To advance non-targeted analyses of environmental samples, we have catalogued approximately 27 000 mass spectra (MS) of the trimethylsilyl derivatives of semi-volatile organic aerosol (OA) analytes in the open-access University of California Berkeley Goldstein Library of Organic Biogenic Environmental Spectra (UCB-GLOBES). Analytes were observed in ambient samples from the U.S. and the Central Amazon and/or laboratory simulations of secondary OA (SOA) formation. These samples are representative of OA under urban and biomass burning influences as well as SOA derived from biogenic precursors (e.g., isoprene, monoterpenes, sesquiterpenes) and biomass burning intermediates. MS are documented in UCB-GLOBES without regard to known chemical identity, annotated with extensive metadata such as sample source/experimental conditions, any structural information gained from MS analyses, and predicted chemical properties such as average carbon oxidation state and carbon number. UCB-GLOBES MS are compatible for importing into the NIST MS Search program, and we have also provided a Jupyter Notebook for MS visualization and comparisons. We demonstrate the utility of UCB-GLOBES through MS reanalyses of prior analytes observed in ambient data, finding a 20 % reduction in the number of analytes assigned to OA source categories reliant solely on time series correlation and an overall 11 % increase in new MS-based OA source categorization for the Southeast U.S. For 1513 analytes observed previously in the Central Amazon, we found 375 MS matches using UCB-GLOBES vs. 136 MS matches during prior analyses, representing a 14 % gain in newly confirmed or newly categorized OA species. While OA from laboratory oxidation experiments in UCB-GLOBES are highly diverse chemically, on average only 29 % of UCB-GLOBES MS have a mass spectral match to another MS entry in UCB-GLOBES and/or in databases of known compounds (i.e. NIST MS Database, Adams Essential Oil, MANE Flavor and Fragrance Company). This indicates that roughly 70 % of UCB-GLOBES MS are unique thus far, not observed more than once among the laboratory oxidation samples and ambient data in UCB-GLOBES MS. Further, only 18 % can be positively identified using these databases or known authentic standards. This points to a large gap between these laboratory simulations and ambient OA. Overall, the UCB-GLOBES database can be utilized for improving confidence in OA source categorization and/or identification, novel chemical marker discovery, tracking chemical diversity, de novo structure and properties prediction, and improving MS search and matching algorithms. This can ultimately inform future research priorities for the chemical characterization of atmospheric organic samples.

Mass spectrometry

Utilization of Unmanned Aircraft Systems for Environmental Purposes at the Savannah River Site – 26578

Born in the 1950s, the Savannah River Plant was constructed as a plutonium and tritium production plant. As the Cold War era came and went, a change of direction was signaled when the name of the facility changed from Savannah River Plant to Savannah River Site (1989) – the main mission at Savannah River shifted from “production” to “cleanup.” The Department of Energy is responsible for managing the 310 square miles of land that is the Savannah River Site and the cleanup/remediation activities that occur. The Savannah River National Laboratory utilizes unmanned aircraft systems to assist with some of those environmental monitoring and remediation activities. One function of unmanned aircraft systems at the Savannah River National Laboratory is conducting aerial photography and videography. Various infrastructure evaluations have been performed with unmanned aircraft – facility rooftop inspections, water tower lock verifications, earthen dam surveys, etc. An unmanned aircraft system has been used for progress footage of remediation projects – Dunbarton Bay remediation, Saltstone Disposal Unit construction, etc. Thermal cameras on an unmanned aircraft system are used to help identify cracks/leaks in structures from vantage points not readily accessible by personnel. Virtual tours of different waste units are conducted with unmanned aircraft systems for Site groups and federal/state regulators to save costs and travel time. Additionally, advanced remote sensing technologies are used on unmanned aircraft systems at the Savannah River Site. Light Detection and Ranging uses laser pulses to measure distances to the Earth's surface or other targets to create highly detailed topographic maps that accurately portray terrain (e.g., elevation changes, slopes, and contours). Data collection with a Light Detection and Ranging unit mounted on an unmanned aircraft system is quick and efficient – large-area surveys are conducted in shorter time frames. Because Light Detection and Ranging can penetrate through foliage and vegetation to ground level, it is being used in conjunction with a watershed model to study the General Separations Area of the Site to determine stormwater flow volume and direction, monitor stream stability, and forecast river flow behavior. A hyperspectral camera captures a wide spectrum of electromagnetic wavelengths across numerous narrow bands, beyond what the human eye can see. It provides detailed spectral information about the objects or surfaces in an image, which can be used to identify and analyze materials based on their spectral signatures. A hyperspectral camera mounted on an unmanned aircraft system has been used at the Savannah River Site for non-destructive evaluation of concrete and concrete structures. Unmanned aircraft systems at the Savannah River Site are also used for the application of herbicide on identified rooftops. P-Reactor and R-Reactor are entombed nuclear reactors at the Savannah River Site. Unwanted vegetation is often present on these rooftops – over time roots can penetrate seams, cracks, and joints of the general roof and concrete caps, leading to water ingress and deterioration of the structural components. For time and cost efficiencies as well as in the interest of personnel safety, an unmanned aircraft is used to dispense herbicide on rooftop areas where vegetation is noticed to help alleviate the issues/hazards.

Lorier, Troy [Savannah River National Laboratory (

Recrystallization, cracking, and erosion of dispersoid-strengthened tungsten materials during exposure to divertor plasmas

In this study, we investigated the effects of combined intense particle and heat flux exposure on advanced tungsten plasma-facing materials within the DIII-D fusion facility. Our test matrix included two types of dispersoid-strengthened tungsten (containing either 100 nm diameter TiO 2 or Ni particles), along with high-purity polycrystalline tungsten as a reference. This experiment relied on a sample geometry angled at 15° relative to the divertor surface, thereby allowing the surfaces to intercept steady-state perpendicular heat fluxes (q ⟂ ) ranging from 10.1 to 19.6 MW/m 2 . During each shot, the samples were exposed to 42 Hz edge-localized modes (ELMs), allowing us to test the material response to transient heating. We correlated the exposure conditions with extensive post-test surface composition analysis and microscopy to determine how the plasma modified each surface. The angled specimens closest to the strike point received the highest combined heat and particle flux and melted midway through the experiment. EBSD analysis revealed they were completely recrystallized throughout, with an average grain size >100 µm. On the other hand, the specimens that received a lower steady state heat flux survived with more superficial surface damage. Whereas the high-purity polycrystalline tungsten exhibited a higher surface roughness, the dispersoid-strengthened material exhibited more extensive shallow inter-granular cracking. In addition, the surface was depleted of dispersoids following plasma exposure, possibly because of evaporation and/or sputtering. The results described here provide insights into the performance of these materials in a fusion environment which can guide further optimization for use in long-pulse devices.

Kolasinski, Robert D. [Sandia National Laboratorie

Assembly bias and local Primordial non-Gaussianity from DESI DR1 quasars

The analysis of the large-scale clustering of quasars (QSO) observed by the Dark Energy Spectroscopic Instrument (DESI) represents a promising avenue for constraining local Primordial non-Gaussianity (PNG), parameterized by f NL . The signal to be constrained is the scale-dependent bias induced in the 2-point clustering of the considered tracer sample. The resulting constraints on f NL , however, are fully degenerate with the local PNG bias parameter b ϕ , dependent on the assembly bias parameter p. Using IllustrisTNG hydrodynamical simulations, we select a QSO sample reflecting the selection criteria and properties of DESI QSOs, and provide a robust prior for p, and thus for b ϕ , building on the findings of Fondi et al. 2024. We find a distribution with mean p̅ ≃ 1.4 with weak redshift dependence, stable to selection noise and consistent with the expected recent merger history typical of quasar-hosting halos. By comparing with the CAMELS simulations we demonstrate that this prior is robust to astrophysical assumptions and cosmic variance. Finally, applying this prior to the DESI DR1 dataset, we derive updated constraints on local PNG, obtaining f NL = -3.3±9.2.

cosmological parameters from LSS

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI