Search NASA⌕ Search

SEARCH · Search NASA

Results for “power flexibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Security Constrained Distributed Transaction Model for Multiple Prosumers

Massive access of renewable energy has prompted demand-side distributed resources to participate in regulation and improve flexibility of power systems. With large-scale access of massive, decentralized, and diverse distributed resources, demand-side market members have transformed from traditional “consumers” to “prosumers”. To explore the distributed transaction model of prosumers, in this paper, a multi-prosumer distributed transaction model is proposed, and the Conditional Value-at-Risk (CVaR) theory is applied to quantify potential risks caused by the stochastic characteristics inherited from renewable energy. First, a prosumer model under constraints of the distribution network including photovoltaic units, fuel cells, energy storage system, central air conditioning and flexible loads is established, and a multi-prosumer distributed transaction strategy is proposed to achieve power sharing among multiple prosumers. Second, a prosumer transaction model based on CVaR is constructed to measure risks inherited from the uncertainty of PV output within the prosumer and ensure safety of system operation in extreme PV output scenarios. Then, the alternating direction multiplier method (ADMM) is utilized to solve the constructed model efficiently. Finally, distributed transaction costs of prosumers are distributed fairly based on the generalized Nash equilibrium to maximize social benefits. Simulation results show the multi-prosumer distributed transaction mechanism established under the proposed generalized Nash equilibrium method can encourage power sharing among prosumers, increasing their own income and social benefits. Also, the CVaR can assist decision making of prosumers in weighting the risks and benefits, improving system resilience through energy management of prosumers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Converter-Interfaced CHP Plant for Improved Grid-Integration, Flexibility and Resiliency

GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber-Physical Reformer Development at NETL

Integrated energy systems are considered one of promising technologies to provide efficient, reliable and resilient power generation. The U.S. Department of Energy, National Energy Technology Laboratory is building an automated reformer-solid oxide fuel cell-gas turbine integrated energy system using a cyber-physical systems (CPS) approach, which exploits the advantage of both numerical model and physical system, as well as gapping the inaccessible technologies. Both the fuel reformer and the fuel cell stack are designed to be CPS components, of which the hardware representations are physically integrated with the gas turbine. A compact design is used with the consideration of future commercialization by placing all components inside of a pressure chamber, which is pressurized by the compressor discharge. (Presented virtually at the MILLENNIUM CLEAN and SUSTAINABLE POWER Workshop 2025)

cyber-physical↗

Probabilistic Risk Assessment of a Light-Water Reactor Coupled with a High-Temperature Electrolysis Hydrogen Production Plant

This report details an expansion of the original two generic probabilistic risk assessments (PRAs) for the addition of a heat extraction system (HES) to a light-water reactor, one for a pressurized-water reactor and one for a boiling-water reactor. The new material in this revision includes a new HES design, direct electrical coupling of the nuclear power plant to the High-Temperature Electrolysis Facility (HTEF), and a smaller 100-MWt HTEF analysis. The results investigate the applicability of the potential licensing approaches, which do not require a full United States Nuclear Regulatory Commission licensing review. The PRAs are generic and include some assumptions. We eliminated many conservative assumptions from the preliminary pressurized-water reactor PRA report using design data for both the HES and HTEF. The PRA results indicate that the 10 CFR 50.59 licensing approach is justified due to the minimal increase in initiating event frequencies for all design basis accidents, with none exceeding 5.6%. The PRA results for core damage frequency and large early release frequency support the use of RG 1.174 as further risk information that supports a change without a full licensing amendment review. Further insights provided through hazard analyses and sensitivity studies confirm with high confidence that the safety case for licensing an HES addition and an HTEF sited 1.0 km from the nuclear power plant is strong and that the placement of a HTEF at 0.5 km is also a viable case. Site-specific information can alter these conclusions.

08 HYDROGEN↗

Flexible metal–gas batteries: a potential option for next-generation power accessories for wearable electronics

Flexible metal–gas batteries have become increasingly attractive for use in wearable electronics in the recent years due to their large theoretical energy density and superior adaptability to irregular geometric surfaces, such as the human body. With continuous improvements in design strategies and assembly technologies, the fabrication of various advanced flexible metal–gas batteries has been attempted. In spite of these efforts, the synchronous integration of high flexibility, safety, comfort, and high performance into flexible metal–gas batteries with specifically functionalized configurations still remains a formidable challenge. To resolve these dilemmas, the redesign of cathode catalysts, gel polymer electrolyte, and battery configurations/components has been investigated. In this paper, we review the recent technical advances together with the major dilemmas facing currently available flexible metal–gas batteries, highlighting how flexible cathodes and gel polymer electrolytes with various structures and components can affect the electrochemical performance and functionality of flexible metal–gas batteries. Flexible Zn–air, Li–O 2 /air, and Li–CO 2 batteries are mainly exemplified to elucidate their promising potential. Finally, based on our considerations, unresolved technical hurdles and future research perspectives involving flexible metal–gas batteries for wearable electronics are proposed.

25 ENERGY STORAGE↗

H2Integrate [SWR-23-31]

H2Integrate(H2I) is an open-source Python package for hybrid systems engineering design and technoeconomic analysis. It models and optimizes hybrid energy plants that produce electricity, hydrogen, ammonia, steel, and other products. H2Integrate is designed to be flexible and extensible, allowing users to create their own components and models for various energy systems. The tool currently includes distributed energy generation (wind, solar, wave, tidal), battery storage, hydrogen, ammonia, methanol, and steel technologies. Other elements such as desalination systems, pipelines, compressors, and storage systems can also be included as developed by users. Some modeling capabilities in H2Integrate are provided by integrating existing tools, such as HOPP, PySAM, ORBIT, and ProFAST. The H2Integrate tool is built on top of NASA's OpenMDAO framework, which provides a powerful and flexible environment for modeling and optimization.

King, Jennifer [National Renewable Energy Laborato↗

A hybrid architecture for volt-var control in active distribution grids

Modern active distribution grids are characterized by the increasing penetration of distributed energy resources (DERs). The proper coordination and scheduling of a large numbers of these small-scale and spatially distributed DERs is necessary, and warrants the use of novel distributed approaches. In this paper, we propose a hybrid volt-var control architecture for the distribution grid, which leverages existing centralized and local approaches to planning, decision making, and control, and augments it with distributed optimization and distributed control for DER management. First, we propose a convex model to describe the power physics of distribution grids of meshed topology and unbalanced structure, based on current injection and McCormick Envelopes. Second, we employ the distributed proximal atomic coordination (PAC) algorithm to coordinate DERs to provide voltage support. We implement volt-var optimization by optimally coordinating DERs including PV smart inverters and demand response. We present results using the IEEE-34 bus network, using real data from a distribution feeder in Hawaii, to model load and PV generation. Different levels of DER penetration and objective functions are simulated. Finally, our results show the need for the coordination of DERs to improve voltage profiles, even in networks with existing voltage control devices. Further, we show the need for flexible reactive power capabilities to achieve desired grid performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Provision of Grid Services by PV Plants with Integrated Battery Energy Storage System: Preprint

Battery energy storage systems (BESS), due to their tremendous range of uses and configurations, may assist PV integration in any number of ways by increasing power system flexibility. In this paper we describe results of a research project conducted by NREL and First Solar for developing controls and demonstrating many use cases for PV-BESS systems including (1) matching generation to loads through time shifting, reducing PV curtailment,; (2) promoting higher levels of PV penetrations by balancing the grid through ancillary services; (3) use of PV-BESS systems to provide wide-area stability services in the form of oscillations damping controls; and (r) use of gird forming BESS for enabling black start and islanded applications for PV-BESS systems. In the paper we will also describe the unique multi-MW test and validation platform developed at NREL for conducting research on fielded utility-scale PV-BESS systems. The platform consists of First Solar 0.43 MW PV power plant, NREL’s 1MW/1MW BESS, 2MW PV power supplies and 7MVA power electronic grid simulator interfaced with industrial plant controllers and power-hardware-in-the-loop (PHIL) capability.

41 EE - Solar Energy Technologies Office (EE-4S)↗

The Impacts of Distinct Flexibility Enhancements on the Value and Dynamics of Natural Gas Power Plant Operations

The rapid increase of renewable generation and its anticipated continued growth requires greater operational flexibility in modern power systems. Previous studies explored the addition of more flexible resources to improve system flexibility, but this may also be achieved at lower cost by enhancing existing power plants via flexibility retrofits. Potential flexibility upgrades to existing thermal plants include modifications that enable faster ramp rates, increase maximum load levels, decrease minimum load levels, and provide faster and lower cost startup operations. In this paper, we focus on improvements to existing natural gas combined cycle generators, and apply a unit commitment model to analyze the impact that each specific upgrade has on their operational dynamics and profitability from both the system perspective and from the asset owner perspective. We show that the value of each type of flexibility improvement varies depending on the capacity factor and usage pattern of the generator before the upgrade, and that the relative benefit of each type of flexibility varies. We demonstrate diminishing returns to increased flexibility when upgrading multiple generators simultaneously. Sensitivity tests for several shares of renewable generation, different generation mixes and different net load realizations confirm the generality of the results shown.

03 NATURAL GAS↗

Co-Firing Switchgrass and Waste Coal in A Power Plant: A Techno-Economic and Life Cycle Evaluation for The Ohio River Valley (SWITCH) (Final Technical Report for Ohio State/FE0032204)

Abandoned coal mine lands (AMLs) represent one of the most persistent environmental challenges in the United States. Prior to the enactment of the Surface Mining Control and Reclamation Act (SMCRA) in 1977, coal mining operations were not legally required to reclaim disturbed lands, leaving behind approximately 500,000 AML sites nationwide. These sites pose severe environmental and health risks, including acid mine drainage, soil and water contamination, and spontaneous combustion of waste coal piles. Millions of Americans live within one mile of these AMLs, underscoring the urgency of remediation. Traditional reclamation practices, such as planting cool-season grasses, often fail to fully restore ecological function or leverage the economic potential of these lands. This project addressed these challenges by developing integrated strategies for resource recovery, land reclamation, and sustainable energy production. This project evaluated an integrated strategy to convert this liability into an opportunity by recovering waste coal and co-firing it with switchgrass (Panicum virgatum L.) cultivated on reclaimed or marginal AML areas in existing coal-fired power plants. Switchgrass not only provides a renewable feedstock but also aids in land reclamation and carbon sequestration. 1) Remote Sensing and Machine Learning for Waste Coal Identification Using Sentinel-2 satellite imagery and supervised classification, we applied four machine learning models to detect historical waste coal piles. Random Forest achieved the highest accuracy (precision: 86%, recall: 77%). Time-series analysis revealed gradual vegetation recovery since 1986, indicating natural reclamation processes in historical sites, while active mining areas showed ongoing disturbance. This workflow enables scalable monitoring and prioritization of reclamation efforts. 2) UAS-Based Stockpile Volume Estimation To quantify recoverable waste coal, we evaluated Unmanned Aerial Systems (UAS) equipped with Light Detection and Ranging (LiDAR) and multispectral sensors. Structure-from-Motion (SfM) photogrammetry combined with interpolated Digital Terrain Models (DTMs) achieved strong agreement with LiDAR reference volumes (Root Mean Square Error (RMSE) ≈147 m 3 , Mean Absolute Percentage Error (MAPE) ≈2%). Sensitivity analysis confirmed that spatial resolution significantly influences accuracy, emphasizing the need for high-resolution data for precise volume estimation. This approach offers a scalable, cost-effective, and accurate alternative to conventional ground-based surveys. 3) Switchgrass Cultivation for Bioenergy and Water Quality Improvement We assessed the hydrological and water quality impacts of converting AMLs to switchgrass production areas using the Soil and Water Assessment Tool (SWAT). Results showed that converting 10% of the watershed area into the switchgrass production zone reduced streamflow by 3.1%, total suspended solids by 18.1%, total nitrogen by 7.6%, and total phosphorus by 6.2%, while achieving biomass yields of 8.6–9.2 metric tons per hectare. These findings highlight switchgrass as a dual-benefit strategy for land reclamation and bioenergy feedstock production. 4) Integrated Co-Firing and CCS for Carbon-Negative Power Generation We modeled co-firing scenarios using the Power Plant Flexible Model (PPFM) to evaluate plant efficiency, greenhouse gas (GHG) emissions, and levelized cost of electricity (LCOE). Without carbon capture and storage (CCS), increasing switchgrass co-firing ratios reduced LCOE from $\$$150/MWh at 0% biomass to $\$$110/MWh at full substitution. Under CCS, costs remained higher (~$\$$250/MWh at 0% biomass) but decreased to $\$$200/MWh at 100% biomass, while enabling net-zero or carbon-negative electricity due to switchgrass sequestration benefits. Although CCS introduced efficiency penalties, pairing it with biomass co-firing offset these impacts and maximized climate benefits. Overall, optimizing co-firing ratios between 60-100%, supported by reliable logistics and storage strategies, emerged as a practical pathway to balance affordability, sustainability, and net-zero or negative GHG emissions while promoting productive reuse of AMLs.

01 COAL, LIGNITE, AND PEAT↗

SiC Based Modular Transformer-less MW-Scale Power Conditioning System and Control for Flexible CHP System

This project aims at developing a SiC-based, modular, transformer-less (60-Hz-transformers-free), MW-scale, four-wire DC/AC power conditioning system (PCS) converter, and a corresponding control system for flexible-CHP (F-CHP) systems. With the help of an F-CHP controller and power electronics converters, different CHP sources, renewable sources, and batteries can be assembled to the DC grid, which is then connected to the medium voltage (MV) AC grid through the PCS converter. To meet grid support and performance requirements, the F-CHP controller design and PCS converter design follow IEEE 1547 and IEEE 2030.7 standards. Five main tasks, including PCS converter design, F-CHP controller development, PCS converter prototype building and testing, F-CHP controller testing, and PCS paralleling, have been carried out. In this project, the F-CHP controller testing has been completed in simulation, HIL and HTB, and the PCS converter prototypes have been successfully built and tested.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Toward 100% Renewable Power Grids: A Review

The transition to a 100% renewable power grid remains beset by significant technical challenges. This paper critically examines the obstacles arising from the variability and unpredictability of renewable energy sources (RES), which complicate the real-time balancing of power generation and load demand. In addition to traditional stability concerns (e.g., rotor angle, voltage, and frequency stability), the increasing penetration of inverter-based resources (IBRs) introduces novel challenges, including resonance stability issues and converter-driven dynamics. Moreover, the dynamic behavior and fault response of IBRs diverge markedly from those of conventional synchronous generators, rendering traditional protection schemes increasingly inadequate. This paper reviews state-of-the-art solutions in power balancing, grid flexibility, stability enhancement, and advanced protection strategies, discussing their implications for future grid design. The analysis provides a comprehensive assessment of recent technological advancements, thereby outlining critical research directions essential for achieving a resilient, 100% renewable power grid.

100% renewable power grid↗

Electrification Futures Study: Power Systems Operation with Newly Electrified and Flexible Loads

The Electrification Futures Study (EFS) is a multi-year study designed to analyze the impacts of widespread electrification in the U.S. energy system. In this webinar we present the detailed power systems operational analysis from the final report in the EFS series. For this analysis, we simulate multiple 2050 power systems for the conterminous United States to assess how variations in the magnitude and shape of electricity demand driven by electrification, and the extent of load participation to more-actively provide grid services, might impact the hourly operation, operational costs, and emissions of various power systems in 2050. The impacts of electrification and demand flexibility are overlayed across systems with significantly greater penetrations of variable renewable energy than today. Overall, we find that the high electrification scenarios envisioned in the EFS with significant VRE penetration (66% of annual national generation) can be operated to meet future increased levels of electrified demand. We also find that demand-side flexibility can enhance operational efficiency and reduce overall annual production costs by $5-$10 billion. The complementary relationship between flexible electric vehicle charging loads and solar generation is particularly pronounced, but in the absence of demand-side flexibility electrification can lead to increased wind and solar curtailment. By helping to reduce renewable curtailment, flexibility can also reduce power sector CO2 emissions. The analysis highlights the value of increased integration and coordination of demand- and supply-side resources in future electric system planning and operations—particularly under high electrification futures.

43 PARTICLE ACCELERATORS↗

A Flexible Quasi-Static Mooring Design Optimization Method for Floating Structures

This paper presents a flexible and efficient design method for optimizing the mooring systems of floating structures. Mooring system optimization is challenging because of the strong nonlinearity of mooring system behavior and the many technical constraints that must be satisfied. Furthermore, different mooring configurations can have very different design spaces. While some successful examples of mooring design optimization exist in the literature, developing an optimization approach that can work across various mooring design problems is a larger challenge. We present such a method based on a flexible parameterization that allows a wide variety of mooring designs to be described by a list of variables, a quasi-static mooring model that provides efficient evaluation of a mooring design without directly considering mooring system dynamics, and an optimization framework that generates, evaluates, and adjusts the mooring design while considering user-specified constraints such as offset limits, strength safety factors, and seabed contact limits. We demonstrate the design optimization framework on four mooring design problems, each for a different type of mooring system. We compare the use of different design modes to simplify the optimization problem, showing that they can reduce the computation time by up to 75%. We also compare different optimization algorithms and find that the resulting computational speed can vary by up to 51 times. We perform a sensitivity study on one design and find that the local sensitivity of anchoring radius to water depth has a positive correlation of 0.29, but the global sensitivity shows large nonlinearities. Lastly, we perform a coupled dynamic analysis on one of the optimized designs and find that the predicted mean platform motions and mooring line tensions are within 1% of dynamic results and the extreme motions and tensions are within 14%. Lastly, we show that a DEA-Chain-Polyester mooring configuration is cost-optimal for the given design problem of the demonstrations, which aligns with general industry practice.

16 TIDAL AND WAVE POWER↗

Phenomenon Identification and Ranking Table Analysis for Thermal Energy Storage Technologies Integration with Advanced Nuclear Reactors

This report provides an overview of the Phenomena Identification and Ranking Table (PIRT) analysis of thermal energy storage (TES) systems for possible integration with various types of advanced nuclear power plants (NPPs). Advanced NPPs will potentially need to operate in environments where power generation flexibility is more highly valued than the stability or baseload generation capability for conventional demand curves. TES systems would enable NPPs to respond nimbly to market variability and could also position advanced NPPs to participate differently in restructured markets, thus further enhancing their economic competitiveness. TES systems could also benefit the electric grid by eliminating the need for peaking plants, as well as by improving the economic performance of baseload NPPs. While TES technologies afford a unique opportunity to address many of these challenges, the applicability of these systems is also complicated by the fact that various advanced NPPs are designed differently, each with its own temperature range, size, operating fluids, and operating conditions. Hence, TES systems face significant barriers to investment, as more information on their compatibility and performance metrics is needed to quantify the advantages provided by each, as well as the challenges these technologies might face if coupled with a particular type of advanced NPP. This report explores the possibility of integrating a wide variety of TES technologies with various categories of advanced NPPs, based on their operating characteristics. To help users and developers decide which TES technology is best suited to a particular category of advanced NPPs, this research developed a PIRT of 10 TES systems that could potentially be coupled with advanced NPPs, which themselves are divided into nine categories based on their operating conditions. Each advanced NPP category is evaluated for compatibility with the 10 TES systems by assembling and discussing a database of information concerning 10 engineering questions (defined herein in as figures of merit [FOMs]), such as: technology readiness level (TRL), temperature compatibility, energy density, size, cycle frequency, ramp time, realignment frequency, geographic needs, environmental impact, and interventions. By assembling a database of information concerning the TES technologies’ compatibility with various advanced NPP systems, this study can help developers acquaint themselves with a particular TES technology before choosing to build a new integrated installation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Mapping thermal energy storage technologies with advanced nuclear reactors

Advanced nuclear power plants (NPPs) will potentially need to operate in environments where power generation flexibility is more highly valued than the stability or baseload generation capability for conventional demand curves. Thermal energy storage (TES) systems would enable NPPs to respond nimbly to market variability and could also position advanced NPPs to participate differently in restructured markets, thus further enhancing their economic competitiveness. TES systems could also benefit the electric grid by eliminating the need for peaking plants, as well as by improving the economic performance of baseload NPPs. While TES technologies afford a unique opportunity to address many of these challenges, the applicability of these systems is also complicated by the fact that various advanced NPPs are designed differently, each with its own temperature range, size, operating fluids, and operating conditions. Hence, TES systems face significant barriers to investment, as more information on their compatibility and performance metrics is needed to quantify the advantages provided by each, as well as the challenges these technologies might face if coupled with a particular type of advanced NPP. This study explores the possibility of integrating a wide variety of TES technologies with various categories of advanced NPPs, based on their operating characteristics. To help decision makers, users and developers decide which TES technology is best suited to a particular category of advanced NPPs, this research present a Phenomena Identification and Ranking Table (PIRT) analysis of 10 TES systems that could potentially be coupled with advanced NPPs, which themselves are divided into nine categories based on their operating conditions. Then, each advanced NPP category is evaluated for compatibility with the 10 TES systems by assembling and discussing a database of information concerning 10 engineering questions, defined herein in as figures of merit (FOMs), such as: technology readiness level (TRL), temperature compatibility, energy density, size, cycle frequency, ramp time, realignment frequency, geographic needs, environmental impact, and interventions. By assembling a database of information concerning the TES technologies' compatibility with various advanced NPP systems, this study can help developers acquaint themselves with a particular TES technology before choosing to build a new integrated installation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Real-time power management technique for microgrid with flexible boundaries

In order to diminish the impacts brought by high penetration of renewable energy on the reliability of distribution systems, some distribution networks (e.g. Chattanooga electric power board system) have deployed smart switches (SSs) to island some areas to mitigate outage losses. However, due to intermittency and sharply changing rate of renewable energy, it is likely to experience insufficient or excessive power for islanded areas. Therefore, a microgrid controller featured with flexible boundaries is proposed. With proposed microgrid controller, the microgrid can not only shrink or expand its boundaries according to current renewable energy supply, but also disconnect/connect to the main grid with a designated SS. Furthermore, to ensure the microgrid controller could obtain suitable boundaries on the time scale of seconds, a real-time power management technique with alternative generating algorithm is designed to generate all possible alternative boundaries and choose the optimal one, which is scalable to any topology. In addition, in order to maintain state of charge of batteries within a desirable range, anti-overcharge/discharge strategies are designed. Four comprehensive experiments verify that the implementation of the microgrid controllers can realise flexible boundaries and deal with sharply changing rate of renewable generation or load on the time scale of seconds.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗