Search NASA⌕ Search

SEARCH · Search NASA

Results for “power grid measuring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

High Performance Adaptive Deep-Reinforcement-Learning-based Real-time Emergency Control (HADREC) to Enhance Power Grid Resilience in Stochastic Environment (Final Report)

The HADREC technology developed in this project features real-time, validated, and predictive emergency control capabilities needed to effectively safeguard the grid against costly disturbances from extreme weather and other disruptive events. It has the potential to revolutionize the emergency control by providing faster and more effective solution for power grid emergency control. The technology can reduce the grid emergency control action time from minutes to seconds and mitigate the impact of outages and reduce system recovery time. The evaluation results using the models and data from PacifiCorp system have shown ~20% improvement in responding time and 70% improved in tripped generator output, comparing against today’s industrial application. This performance can help reduce preventive measurements and improve network utilization and market efficiency, and help lead to a more reliable and resilient power grid with renewable integration. The project has generated significant interest from industry, academic and commercial companies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Measurement Adequacy for Monitoring Data Center Oscillations

Artificial intelligence (AI) training data centers with periodic load profiles can induce sustained grid oscillations across a wide frequency range, making accurate monitoring essential for reliable power system operation. This report evaluates the adequacy of existing measurement systems for monitoring such oscillations, focusing on phasor measurement units (PMUs) and point-on-wave (POW) measurement systems. The analysis shows that while PMUs are highly effective for monitoring low-frequency electromechanical oscillations, they have inherent limitations in accurately representing higher-frequency oscillations due to constraints imposed by reporting rates and the bandwidth of phasor estimation filters. Even when configured with higher reporting rates, the filtering inherent in the phasor estimation process can significantly attenuate oscillation magnitudes, potentially leading to underestimation of oscillatory behavior. This has important implications for compliance and performance monitoring of large loads. To address the limitations associated with PMU-based monitoring, the report examines the use of high-resolution POW measurements, which can capture oscillations across a broader frequency range. However, continuous POW monitoring introduces practical challenges related to large data volumes, communication bandwidth, and real-time data processing. For this reason, the report also discusses emerging approaches that use POW measurements as a complementary capability alongside PMUs to improve observability of oscillations from large data center loads.

47 OTHER INSTRUMENTATION↗

Development and Evaluation of a Cost-Effective Behind-the-Meter Synchronized Measurement Unit for Enhanced Grid Integration

This paper presents the development of the Inverter Based Resource Monitor (IBRM), an innovative behind-the-meter synchronized measurement unit (SMU) tailored for integration with inverter-based resources (IBRs). The IBRM distinguishes itself as a highly accurate and cost-effective SMU, offering facile deployment and connectivity to IBRs. It is equipped to conduct real-time voltage and current waveform analyses, serving as a phasor measurement unit (PMU) with exceptionally rapid synchrophasor transmission capabilities. The device incorporates a cutting-edge dual-core architecture designed to minimize sampling delays inherent to its microprocessor, thereby enhancing the precision of synchronized waveform measurements. Moreover, the IBRM is adept at recording high-fidelity waveform data, capturing nuances such as waveform distortions, high-order harmonics, and wide-band oscillations prevalent in power grids with substantial IBR presence. A prototype of the IBRM has been constructed and subjected to rigorous testing to assess its functional capabilities and measurement precision, utilizing both idealized signal generators and a real-world off-grid inverter setup as benchmarks.

Wu, Ori [ORNL] (ORCID:0000000326723410)↗

Dynamic Power Network State Estimation with Asynchronous Measurements

The operation of distribution networks is becoming increasingly volatile, due to fast variations of renewables and, hence, net-loading conditions. To perform a reliable state estimation under these conditions, this paper considers the case where measurements from meters, phasor measurement units, and distributed energy resources are collected and processed in real time to produce estimates of the state at a fast time scale. Streams of measurements collected in real time and at heterogenous rates render the underlying processing asynchronous, and poses severe strains on workhorse state estimation algorithms. In this work, a real-time state estimation algorithm is proposed, where data are processed on the fly. Starting from a regularized least-squares model, and leveraging appropriate linear models, the proposed scheme boils down to a linear dynamical system where the state is updated based on the previous estimate and on the measurement gathered from a few available sensors. The estimation error is shown to be always bounded under mild condition. Numerical simulations are provided to corroborate the analytical findings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mechanism Analysis of Wind Turbine Var Oscillations

Electromagnetic transient simulation of parallel connected 4-MW type-3 wind turbines based on original equipment manufacturer's real-code turbine model shows 1.2-Hz turbine-turbine oscillations in reactive power. This letter reveals why such oscillations occur in the individual var measurement, while being insignificant in the total var measurement, regardless of the varying grid impedance. We adopt two analysis approaches: open-loop single-input single-output analysis and network decomposition. The two approaches differ in their treatment of turbine-network interaction. The open-loop analysis shows that the turbine-turbine oscillation mode is due to an open-loop system pole being attracted to an open-loop system zero. Furthermore, we use network decomposition method to explain why this mode is observable in individual vars while not observable in the total var. The entire system of n -turbines can be viewed as n decoupled circuits. For the two-turbine case, the system has an aggregated mode and a turbine-turbine oscillation mode. Here, the aggregated mode is associated with a circuit associated with the total var, while the turbine-turbine oscillation mode is associated with the var difference and is insensitive to the grid parameters.

17 WIND ENERGY↗

Formulation of Three-Phase State Estimation Problem Using a Virtual Reference

State Estimation (SE) is the backbone of modern Energy Management System (EMS) due its capability of processing real time measurements and provide reliable information to system operators. Since its introduction to power systems in the 70’s, SE has been widely used in transmission networks. Distribution grids on the other hand lack sufficient number of real time measurements, and for that reason SE has not been widely implemented on these systems. The recent increase in the number of renewable energy sources connected to the grid at lower voltage levels, the advent of Distribution Automation (DA) and Smart Grids necessitate closer monitoring of distribution networks and thus forcing utilities to upgrade their operations and deploy Advanced Distribution Management Sytems (ADMS). Therefore, Distribution System State Estimation (DSE) is paramount to provide real time monitoring of active distribution grids. This papers investigates the formulation of the three-phase distribution state estimation where in the most general case, none of the system buses may have balanced three phase voltages. In such a case, the choice and definition of the slack bus need to be revisited. Most of the existing work arbitrarily assign the root bus of the distribution feeder as the balanced three-phase reference which may not be realistic for today’s active distribution systems. This paper addresses this shortcoming of the existing SE formulations by introducing a virtual reference bus. Here, the proposed approach is effectively validated by simulations carried out on distribution test systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Demand-side solutions in the US building sector could achieve deep emissions reductions and avoid over $100 billion in power sector costs

Buildings are energy-intensive and a primary source of US end-use sector carbon emissions. Although building emissions today are 25% below their 2005 peak, far deeper reductions are needed to reach the US 2050 net-zero emissions goal. However, plausible decarbonization pathways that consider both buildings and their interactions with the power grid remain poorly understood. Here, we couple detailed modeling of building energy use and the grid to quantify building decarbonization potential and associated grid impacts. We find up to a 91% reduction in building CO 2 emissions from 2005 levels by 2050 using a portfolio of building efficiency, demand flexibility, and electrification measures alongside rapid grid decarbonization. Building efficiency and flexibility could generate up to $107 billion in annual power system cost savings by 2050, offsetting over a third of the incremental cost of full grid decarbonization. Our results underscore multiple benefits of demand-side solutions for deep decarbonization of US buildings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

MULTI-FIDELITY MODELING AND UNCERTAINTY QUANTIFICATION OF INVERTER BASED RESOURCES IN INTEGRATED T&D SYSTEMS

Uncertainty quantification plays a pivotal role in improving the accuracy and reliability of inverter operation within modern power systems that are increasingly dominated by inverter-based resources (IBRs). IBRs, especially those operating under grid forming (GFM) control, rely heavily on a complex set of control parameters and system measurements to maintain voltage, frequency, and power balance. Traditional deterministic modeling approaches often fail to capture these parameter deviations, potentially resulting in suboptimal control actions, reduced system stability, or even instability under high penetration of IBRs. In this paper, we demonstrate the application of model calibration and uncertainty quantification (UQ) principles to an integrated transmission and distribution (T&D) model involving a GFM converter and provide a framework for prioritizing control improvements, guiding robust design, and informing adaptive strategies that can accommodate real-time variability in system conditions. The proposed approach could be valuable in enhancing the robustness of current and future power systems under increased IBR penetrations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Active Detection Scheme for Sensor Spoofing in Grid-tied PV Systems

In this paper an active detection scheme for sensor spoofing (manipulated externally via a cyber attack) in grid-tied PV systems is discussed. The core of the proposed active detection scheme is to introduce a private (secret) watermarking signal into the control inputs of the DC-DC converter and DC-AC inverter stages to detect any malicious spoofing (manipulation) of voltage/current sensor measurements controlling both the DC-DC converter maximum power point tracking (MPPT) stage and the DC-AC inverter of the grid-tied PV system. Several types of possible spoofing mechanisms (attack models) are discussed. The proposed sensor spoofing attack detector system consists of injecting a small magnitude of digital watermarking signal (DWS) and conduct three statistical watermark tests on the reported sensor measurements to determine if a) the proposed system is healthy and operating as expected b) if sensor signals were spoofed (manipulated) externally or c) if a particular sensor is malfunctioning due to a faulty hardware. It is shown via extensive simulations that the proposed DWS approach is robust in detecting malicious external manipulation of sensors controlling the grid tied PV system. A testing platform is currently under development and the experimental results will be discussed in the conference presentation.

Ibrahim, Hasan↗

Data Security Defense: Modeling and Detection of Synchrophasor Data Spoofing Attack for Grid Edge

Data security and cyberattack have become critical issues in the distributed power system where adversaries can swap the source information of sensors or even spoof and alter measurements. However, the cyber security of the power system is challenged by the unpredictability and stealth of the spoofing attacks. Here, to protect the data security at the grid edge, this paper developed a synchrophasor data spoofing attack detection framework based on the time-frequency feature extraction techniques including the short-time Fourier transform (STFT) and object detection network for real-time synchrophasor data categorization and spoofing attack localization. The proposed approach outperforms earlier work in terms of spoofing attack detection and offers a vital localization function employing distributed synchrophasor sensors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid Event Signature Library Analytics Report: Signature Matching Tool Development Efforts

This report describes the purpose and features of the Signature Matching Tool (SMT), employed in the Department of Energy (DOE) Grid Event Signature Library (GESL). The SMT supports a user of GESL to identify snippets of electric signatures, usually from sensor devices measuring electric characteristics such as phase voltages and currents, frequency, etc., suspected to represent certain events in the power grid but are not known to the user. The SMT uses a classification method to identify an event of the unknown signature, using the repository of known and labeled signatures in the GESL. The classifier applies a local binary classifier per node (LCN) approach to the unique event tag taxonomy used in the GESL, where training phases are separated based on the Primary labels in the taxonomy, sensor type, and voltage level. Results show that this method helps with computing time during training, in comparison to a flat, multinomial classifier, and produces acceptable average accuracy of 83% across all Primary labels. The report concludes with planned future work including integration to the web interface and API.

97 MATHEMATICS AND COMPUTING↗

A comprehensive framework for validating simulation models of power system equipment using terminal measurements

Accurate simulation of power-plants is essential to the planning and operation of modern power grids. The current methods used to periodically check power-plant simulation models have many open questions about their limitations and accuracy. The research in this project explored using Monte-Carlo Experimentation (MCE) as a means for answering these important questions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Finite-time correlations boost large voltage angle fluctuations in electric power grids

Abstract Decarbonization in the energy sector has been accompanied by an increased penetration of new renewable energy sources in electric power systems. Such sources differ from traditional productions in that, first, they induce larger, undispatchable fluctuations in power generation and second, they lack inertia. Recent measurements have indeed reported long, non-Gaussian tails in the distribution of local voltage frequency data. Large frequency deviations may induce grid instabilities, leading in worst-case scenarios to cascading failures and large-scale blackouts. In this article, we investigate how correlated noise disturbances, characterized by the cumulants of their distribution, propagate through meshed, high-voltage power grids. For a single source of fluctuations, we show that long noise correlation times boost non-Gaussian voltage angle fluctuations so that they propagate similarly to Gaussian fluctuations over the entire network. However, they vanish faster, over short distances if the noise fluctuates rapidly. We furthermore demonstrate that a Berry–Esseen theorem leads to the vanishing of non-Gaussianities as the number of uncorrelated noise sources increases. Our predictions are corroborated by numerical simulations on realistic models of power grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Statistical Analysis of Inter-Area Oscillations in the U.S. Eastern Interconnection: A 2017-2023 Perspective

Recent advancements and the accumulation of high-resolution, long-term phasor measurement unit (PMU) data have provided detailed insights into inter-area oscillations in power grids. This study conducts a comprehensive statistical analysis of inter-area oscillations within the United States Eastern Interconnection from 2017 to 2023. Utilizing data captured by the advanced wide-area Frequency Monitoring Network (FNET/GridEye), this investigation examines the occurrence patterns, dominant frequencies, damping ratios, and excitation mechanisms of these oscillations. Our analysis sheds light on the evolving statistical behaviors of inter-area oscillations, offering updated and critical information for grid operators and planners. The insights gained from this study can be instrumental in enhancing the operational resilience of the power network and guiding strategic developments in grid infrastructure to accommodate future challenges. Additionally, the study discusses emerging challenges associated with the modernization of the power grid, including increased renewable penetration, dynamic load variability, and cyber-physical vulnerabilities that complicate oscillation monitoring and control.

Inter-area oscillations↗

Rapid Event Detection via Synchro-Waveform Based Temporal Attention Network in Distributed Grid

Compared with the information collected from phasor measurement units, synchro-waveforms contain high-fidelity disturbances of the grid, which can be a granular and authentic representation of measurements in the modern power system. However, the dynamic changing morphology makes it challenging to effectively capture various disturbance information from the synchro-waveforms. To tackle this issue, this paper proposes a Synchro-waveform based Temporal Attention (STA) network to achieve rapid event detection. First, a multi-scenario distributed model with renewable integration is established to generate synchro-waveforms under various uncertainties. Then, three typical temporal features are extracted directly from the synchro-waveform measurements. Additionally, the lightweight STA network is deployed to identify the most common event types in renewable energy systems via the self-attention based vision transformer module. The results from simulated experiments demonstrate that the proposed approach can achieve rapid and real-time detection within 0.81 ms and over 96.27 % accuracy.

Dong, Yuqing [University of Tennessee (UT)]↗

Machine Learning-based False Data Injection Attack Detection and Localization in Power Grids

Cyberattacks on critical infrastructures can be catastrophic and bring nations to their knees. Therefore, detecting these attacks is crucial and challenging. This paper presents a novel approach for detecting and locating cyberattacks affecting an electrical power system. The adversary employs a man-in-the-middle technique to inject false data into the communication between distributed energy resources (DER) and Microgrid Controller (MGC) with the goal of disrupting power delivery. The approach for detection and localization is based on integrating multiple machine learning-based anomaly detection models that combine network traffic data and grid measurements. Experiments are performed to assess the method's performance using a hardware-in-the-loop real-time simulation testbed which includes Modbus TCP/IP communication. Power system topology and operating conditions are based on actual topology and real-world data provided by the Holy Cross Energy utility network. Results confirm that the method can be successfully employed for detecting and localizing cyberattacks.

Leao, Bruno P.↗

Assessment of the Phase-to-Ground Fault Apparent Admittance Method with Phase/Ground Boundaries to Detect Types of Electrical Faults for Protective Relays Using Signature Library and Simulated Events

Protective relays in electric power grids recognize the types of electrical faults in a few seconds. The most common detection method to detect the types of electrical faults is based on measuring the angle between the zero and negative sequence currents. However, it is not completely accurate because the phase-to-phase-ground and phase-to-ground electrical faults could have the same detection conditions. Therefore, engineers need to plot the events after an electrical fault to observe the nature of the incidents in detail. In this study, the phase-to-ground fault apparent (PGFA) admittance method with phase/ground boundaries identified the types of electrical faults located in distribution power lines and feeders. This method was based on measuring the PGFA admittance magnitudes for the faulted and nonfaulted phases, resulting in greater than zero and near zero, respectively. The PGFA admittance algorithm was built with MATLAB/Simulink software and tested with signature library and grid simulation events. The PGFA method with phase/ground boundaries was evaluated with the confusion matrix. The measured and predicted values matched in more than 90% of the tests, and the PGFA admittance method with phase/ground boundaries presented an accuracy of 94.3% and a precision of 100%.

42 ENGINEERING↗

Blockchain-Enabled Cyber-Secure Microgrid Control Using Consensus Algorithm

This paper proposes a distributed control method based on a consensus algorithm for distributed energy resources (DERs) using blockchain as a secure communication medium for cyber resilience. Each DER communicates with a local blockchain server that is maintained by the distributed ledger technology to allow for securely sharing local measurements among neighbouring assets to achieve the global control objectives, i.e., voltage and frequency regulation as well as accurate power sharing among the DERs, including collective grid-forming capability. To prove that the distributed control can retain system stability under a blockchain-induced variable communication delay, Lyapunov function-based stability analysis is carried out. This paper demonstrates the concept on an 11-bus test case developed in MATLAB Simulink, which has been modified from the IEEE 9-bus test case, to study dynamic operations of the five inverter-based DERs working with a blockchain-induced variable delay. The results validate the superior performance of the proposed control method, compared to heavily compromised operations of the other test cases without the security measure, affected by heavy communication delays and communication interruptions.

blockchains↗