Search NASA⌕ Search

SEARCH · Search NASA

Results for “power sharing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Global Biodiversity Implications of Alternative Electrification Strategies Under the Shared Socioeconomic Pathways

Addressing climate mitigation while meeting global electrification goals will require major transitions from fossil-fuel dependence to large-scale renewable energy deployment. However, renewables require significant land assets per unit energy and could come at high cost to ecosystems, creating potential conflicts between global climate mitigation and biodiversity conservation. Here, we explore the potential biodiversity implications of alternative future global electrification pathways as depicted under the Shared Socioeconomic Scenarios (SSPs), i.e., alternative trends in societal development. We examined the intersection of high-resolution estimates of global energy densities for ten renewable and conventional technologies with global richness data to estimate technology-specific biodiversity footprints (species per GWh), whereas a Cumulative Biodiversity Impact (CBI) score was used to assess land and biodiversity outcomes of alternative scenarios. Downscaled electricity generation scenarios (2020-2100) were also constrained by alternative land conservation and energy development policies. Unexpectedly, variation among SSPs did not exhibit a clear tradeoff between global climate mitigation and CBI. Rather, CBIs were an outcome of total infrastructure development to meet electricity demand (from population growth and GDP) and the total magnitude of renewable energy development and storage technologies. Renewables assembled along a spectrum from land sharing to sparing. At the land sharing end, biomass-powered electricity from dedicated crops contributed the most to biodiversity impacts due to low energy density, whereas land-sparing technologies (solar) caused more-intense land degradation, but in smaller areas. Our results suggest that local land conservation practices and strategies promoting energy diversification could have greater implications for future biodiversity conflicts than global socioeconomic drivers.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

First snowflake divertor experiments in MAST-U tokamak

First snowflake (SF) divertor experiments in the MAST-U tokamak demonstrated steady-state snowflake-plus divertor configurations in 450 kA ohmic L-mode plasmas. The SF divertor configuration features a second poloidal field (PF) null in the divertor region close by or overlapping with the main X-point. The resulting low PF region and two additional divertor legs (strike points) may lead to additional power and particle flux sharing via a hypothesized convective cell, and increased plasma-wetted area and radiation. The free-boundary Grad–Shafranov equilibrium code FIESTA was used to design SF configurations with several inter-null distances and orientations. In the experiment, the SF configurations with inter-null distances 0.13–0.20 m and lasting 0.2–0.3 s were obtained. Parallel connection lengths between the midplane and the outer strike point in the SF configurations (evaluated at field lines 1–2 mm from the separatrix in the midplane) were 25–30 m, higher than in the standard divertor (20–25 m) or the Super-X divertor (25 m). Diagnostic measurements highlighted salient SF features. The infra-red video bolometer diagnostic showed that the radiated power peaking in the PF null region was not as pronounces as in the standard divertor. Divertor ion fluxes measured by target Langmuir probes showed increased ion flux in the plate region where a secondary SF strike point landed, concomitantly with the SF formation. These measurements may suggest that some particle and heat redistribution was taking place in the convective SF zone. The first SF experiments provide a basis for future SF studies in MAST-U tokamak with higher input power, improved plasma control and diagnostic measurements, to be compared with the modeling predictions of plasma convective SF mixing and lower density strike point detachment threshold.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Opening Up Transactive Systems: Introducing TESS and Specification in a Field Deployment

Transactive energy systems (TS) use automated device bidding to access (residential) demand flexibility and coordinate supply and demand on the distribution system level through market processes. In this work, we present TESS, a modularized platform for the implementation of TS, which enables the deployment of adjusted market mechanisms, economic bidding, and the potential entry of third parties. TESS thereby opens up current integrated closed-system TS, allows for the better adaptation of TS to power systems with high shares of renewable energies, and lays the foundations for a smart grid with a variety of stakeholders. Furthermore, despite positive experiences in various pilot projects, one hurdle in introducing TS is their integration with existing tariff structures and (legal) requirements. In this paper, we therefore describe TESS as we have modified it for a field implementation within the service territory of Holy Cross Energy in Colorado. Importantly, our specification addresses challenges of implementing TS in existing electric retail systems, for instance, the design of bidding strategies when a (non-transactive) tariff system is already in place. We conclude with a general discussion of the challenges associated with “brownfield” implementation of TS, such as incentive problems of baseline approaches or long-term efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Substation Secondary Asset Health Monitoring and Management System (SSHM)

Electric Power Group, LLC (EPG) was awarded DOE OE0000850 to design, develop, and demonstrate a real-time software application for substation secondary equipment health monitoring and management at host utility American Electric Power (AEP), a cost share partner. This project addresses the need for monitoring substation equipment health and providing operators with tools to identify and take pre-emptive action to avoid catastrophic equipment failure. By monitoring synchrophasor data in real time, data anomalies that indicate potential asset failure can be detected and alerts can be sent to operators in time to take corrective actions. EPG developed two data driven algorithms to identify abnormal equipment signature patterns as well as a method using substation linear state estimation (SLSE). The software has been deployed on hardened PC’s and tested and validated for cost share partner AEP’s substations - 138kV and 765 kV. The SSHM software has been accepted by AEP and final demonstration of DOE - OE0000850 for AEP and DOE was successfully completed on March 17th, 2020. EPG developed the Substation Secondary Asset Health Monitoring (SSHM) Platform to analyze equipment failure signatures in PMU data and alert substation personnel when pre-emptive inspection, repairs and other actions are warranted to prevent potential catastrophic failures. This is the first system that automatically monitors the health of substation secondary assets and alerts users to emerging failures using synchrophasor measurements. SSHM uses high resolution PMU data from PTs, CTs, and CCVTs to analyze equipment signatures and identify anomalies that are precursor indicators of potential equipment failure. When an anomaly is detected, there is a likelihood of potential failure of monitored equipment, the system alerts the user with visual alarms including alarm trend charts and indicator lights on a oneline diagram of the substation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermal Analysis of Liquid and Air Cooling of High-Power-Density Integrated Motor Drives

Thermal management is a crucial aspect in the design of motor and drive systems. This paper introduces a coordinated cooling approach utilizing both liquid and air to enhance the integrated motor drive's power density. The proposed solution incorporates a shared water jacket to cool both the machine and power electronics, combined with forced air ventilation for the end windings and rotor. This approach is structurally simpler, less expensive, and more effective than conventional non-interacting cooling schemes. The paper addresses the modeling of key thermal features and nonlinearities including material anisotropy, contact thermal resistance, and uneven winding loss distributions. In addition, this study utilizes a more detailed model of the loss distribution among the winding turns in each slot that delivers a higher level of accuracy. Finite Element Analysis (FEA) results demonstrate the effectiveness of the integrated cooling system for efficiently cooling the designed integrated motor drive system.

42 ENGINEERING↗

Macro Analysis to Estimate Electric Vehicles Fast-Charging Infrastructure Requirements in Small Urban Areas

Electric vehicles (EVs) are known to reduce emissions and fossil fuel dependency. However, the limited range, long charging time, and inadequate charging infrastructure have hampered the adoption of EVs. The current EV charging infrastructure planning studies and tools require detailed information, extensive resources, and skills that can be a significant barrier to urban areas for finding the required charging infrastructure to support a targeted EV market share. This study generates regression models to estimate the number of direct current fast charging stations and the chargers to support the EV charging demand for urban areas. These models provide macro-level estimates of the required infrastructure investment in urban areas, which can be easily implemented by policy-makers and city planners. This study incorporates data obtained from applying a disaggregate optimization-based charger placement model, developed recently by the same authors, for multiple case studies to generate the required data to calibrate the macro-level models, in the state of Michigan. This simulated data set includes the number of charging stations and chargers for each market share, technology advancement scenario, and the transportation network topology. The results show that the number of charging stations reduces with battery size and charging power and increases with EV market share and the road network lane length. The number of chargers reduces with charging power, whereas it increases with battery size, EV market share, and vehicle miles traveled in the system. The model developed here can be applied to any state having urban characteristics and weather conditions similar to Michigan.

Engineering↗

Microwave Plasma Flash Pyrolysis for Coal-to-Product Applications

Since 2010, the US coal industry has experienced a precipitous decline, with coal production volumes dropping by as much as 35% according to EIA. This decline is hardly surprising given that 90% of domestic coal use is allocated to electricity production: While coal generation supplied about 45% of the nation's power in 2010, its share is projected to fall to only 22% in 2020. Fortunately, alternative uses for coal as a feedstock rather than as energy source are available. Coal tar is an established feedstock for chemicals and high-value carbon products including carbon fiber and battery-grade graphites. At present, growth of these uses is constrained by the low availability, purity, and yields of currently available coal liquids, and high energy- and CO2-intensity of current methods of production (i.e. coking). Previously reported work conducted in a partnership with Pacific Northwest National Laboratory demonstrated technical and economic viability of flash pyrolysis of coal in a microwave plasma environment at bench scales targeting production of fuel feedstocks (synthetic oil). H Quest’s work since then indicated promise of microwave-derived coal liquids to be uniquely suited for the lower-cost production of carbon materials, including synthetic graphite, carbon fiber, and composites. Low bulk process temperatures, subsecond residence times, and ambient pressure operation enable small-scale deployment, reduce capital and operating costs, and suppress formation of impurities, including QI material, typical in conventional coal tars. With no inherent production of CO2 or water consumption, microwave plasma flash pyrolysis presents a viable route to the sustainable production of both platform chemicals and carbon-based materials. Most recently, H Quest developed a novel, ruggedized microwave plasma reactor, which departs from the proof-of-concept approach and addresses the problems typically encountered in scaling laboratory microwave plasma apparata (e.g. eliminating fragile quartz enclosures prone to coking and fouling). This reactor has been integrated with a 15kW microwave power supply, a pulverized coal injection system, and a product recovery system. A series of screening tests across a range of coals (including hv-, lv-bituminous and subbituminous PRB), entrainment gas flows and compositions and microwave energy inputs are performed to evaluate conversion rates within the novel, scaled-up system, confirm yields of liquid products, and to perform compositional (GC/MS and elemental) analyses of the products. Results of these tests will be presented and discussed.

Skoptsov, George↗

An interregional optimization approach for time series aggregation in continent-scale electricity system models

Modeling electric power systems with high shares of weather-dependent resources requires tradeoffs between temporal, spatial, and operational resolution. Many studies perform time series aggregation using clustering algorithms to reduce the temporal dimension, but when modeling continent-scale electricity systems that are large enough to contain multiple independent weather systems, this approach requires large numbers of representative periods to minimize errors in regional wind and solar capacity factors. Here, a new optimization-based approach for representative period selection and weighting is introduced that minimizes regional errors in average renewable capacity factors and electricity demand. The method delivers higher regional fidelity with fewer representative periods than alternative clustering methods when applied to wind, solar, and demand profiles for the contiguous United States. When representative periods are selected from multiple weather years, the optimized method reproduces regional averages with lower error than a complete 365-day time series from any single weather year. The method identifies only representative (as opposed to outlying) periods but can be combined with an iterative "stress period" identification approach to guide efficient decision-making considering both average and high-risk weather conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SIW21-95: Hybridizing Synchronous Condensers with Grid-Forming Battery Energy Storage Systems

One of the main challenges associated with deployment of high shares of inverter-based resources (IBRs) in power grid is not only reduced system inertia but also degrading system strength that may cause severe stability impacts. A minimum level of system strength is needed for the power system to remain stable under normal conditions and to return to a steady state condition following a system disturbance. Significant system strength reduction is expected in almost all planned areas for solar and wind generation deployment. Synchronous condensers (SC) have been considered as one main technology to address the system strength issues for the areas with high levels of IBRs. SCs can help improving reliability and resiliency of power system but they do not provide the full range of services needed by power systems for reliable and economic integration of high shares of inverter-coupled variable generation such as PV generation. Services related to active power controls cannot be provided by SCs due to lack of prime mover. Even for provision of reactive power SCs have certain constraints based on their thermal and stability limits. NREL has been conducting research on a hybridized concept that combines SCs with grid forming (GFM) battery energy storage systems (BESS). This super flexible AC transmission system (SuperFACTS) that combines these two technologies in a single plant under the same controller offers a unique scalable set of services to the power system at all levels (transmission, sub-transmission, distribution, islands and isolated microgrids). Depending on use cases, SuperFACTS can be controlled to provide fully dispatchable and flexible operation using energy storage component, provide a full range of existing and future ancillary and reliability services to the grid (similar or better than conventional sources), maintain adequate levels of grid strength and inertia, and provide fault current for proper operation of protection systems. Therefore, this economic and easy to commercialize solution has potential for significant impacts on certain segments of global energy sector. All types of gird services (market based, reliability and resiliency) can be provided by SuperFACTS plants. GFM BESS can act as a self-black start source for each SuperFACTS module, which in turn can act a black start resource for co-located PV and wind power plants, segments of transmission and distribution networks, for conventional power plants, etc. The issue of in-rush currents during black start is addressed by overcurrent capability of SCs. In this paper we describe the results of modeling for SuperFACTS concept.

grid forming↗

Methods for Computing Physically Realistic Estimates of Electric Water Heater Demand Response Resource Suitable for Bulk Power System Planning Models

Demand response is commonly called on to reduce load during system peak times or to respond to contingency events. In future power systems with higher shares of wind and solar generation (which we describe together as variable generation [VG]), demand response could have more opportunities to provide energy shifting or operating reserve services. This report evaluates the ability of residential electric water heaters, both electric resistance water heaters (ERWHs) and heat pump water heaters (HPWHs), to provide such services starting from detailed whole-building energy models that realistically represent New England single family home stock. We use a parsimonious surrogate model to represent operational flexibility in a form suitable for linear and mixed integer programming. This enables relatively fast determination of aggregate contingency reserve resource, price-taking energy shifting outcomes, and in some cases the determination of aggregate models at the megawatt (MW) scale that can be directly included in large-scale grid models. After selecting modeling methods and parameters through various computational experiments, we find interquartile ranges of contingency reserve resource in ISO-NE for about 603,400 ERWHs of 45 MW - 69 MW for Claim10 (50 minute responses provided with 10 minutes of advanced notification) and 65 MW - 102 MW for Claim30 (30 minute responses provided with 30 minutes of advanced notification), and for about 619,000 HPWHs of 48 MW - 88 MW for Claim10 and 52 MW - 90 MW for Claim30. The overall reserve resource is up to 32% of total load for ERWHs providing Claim10 service, 47% for ERWHs providing Claim30 service, 93% for HPWHs providing Claim10 service, and 97% for HPWHs providing Claim30 service. More work is required to determine if HPWHs are inherently more suitable than ERWHs for providing contingency reserve or if these results reflect idiosyncrasies of the single family home stock model used in this study. The value of this contingency resource in a Near-term VG model of ISO-NE is $\$ 0.40$ to $\$1.20$ per water heater-year, and significantly larger, $\$ 3.80$ to $\$ 5.30$ per water heater-year in a Mid-term VG model of ISONE. Aggregating surrogate models to the MW-scale for energy shifting service is more challenging than for contingency service and we only present such results for ERWHs, because we were unable to determine satisfactory ways to deal with HPWHs' time-varying and path dependent operational characteristics. Individual surrogate models suitable for evaluating the energy shifting resource from both ERWHs and HPWHs are created, however, and dispatched against day-ahead prices from the Near-Term VG and Mid-Term VG models of ISO-NE. The individual surrogate models are able to access and potentially shift all 640 GWh of HPWH load and 1,547 GWh of ERWH load we modeled in two different single family home stock models. In contrast, the most effective model of aggregate ERWH shifting resource we created only captured 34.7% of the total ERWH load. Energy shifting affected by price-taking dispatch against modeled day-ahead energy prices produces per water heater year profits of $\$19.44$ - $\$22.93$ for individual HPWHs, $\$39.11$ - $\$40.54$ for individual ERWHs, and up to $\$4.00$ - $\$4.24$ for aggregated ERWHs, with the variations mainly due to grid conditions (more or less VG). When the supply-side response to these changes is accounted for, the per water heater year production cost savings for ISO-NE are $\$7.50$ to $\$17.70$ for the most effective set of endogenously dispatched aggregate ERWHs, $\$15.60$ to $\$15.70$ for individual ERWHs dispatched against the DA prices, and $\$10.70$ to $\$11.20$ for individual HPWHs dispatched against DA prices. Those ranges primarily represent the difference between Near-Term VG and Mid-Term VG grid conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Soft-switching voltage-edge-rate-limiting power inverter

An auxiliary resonant soft-edge pole inverter circuit is provided. The power inverter circuitry may include a first pair of capacitors in parallel with a corresponding pair of main power switching modules, each power switching module comprising a switch and a diode in parallel and sharing a common central node with the first pair of capacitors. The power inverter circuit may further include a first pair of auxiliary switches connected in series with a first pair of inductors, respectively, to generate resonant current from a DC power source, the first pair of inductors also sharing the common central node. The power inverter circuitry may further include a second pair of auxiliary switches connected in series with a second pair of capacitors, respectively, the second pair of auxiliary switches also sharing the common central node, the circuit producing an alternating current output at the common central node.

Wasynczuk, Oleg↗

Interactive Power to Frequency Dynamics Between Grid-Forming Inverters and Synchronous Generators in Power Electronics-Dominated Power Systems

With increased attention on grid-forming inverters as a power system stabilizing device during high shares of inverter-based resource operations, there is a present need for a transparent and methodical investigation of the inverted and direct power to frequency control capabilities and impacts of these devices on emerging power systems. Here, analysis of the frequency dynamics of the droop-controlled grid-forming inverter and the synchronous generator illuminates the inverted active power-frequency relationship and the frequency response order reduction, forming the basis for novel, nonlinear frequency control approaches. Device-level electromagnetic transient domain simulations corroborate the order-reduction findings, establish that a properly designed dc-side system has a negligible impact on power transfer and will not impede frequency regulation, and confirm the primary frequency response improvement with nonlinear control. Simulations of the 9- and 39-bus test systems validate the order reduction and associated decoupling of the nadir and rate of change of frequency in larger networks. Oscillatory mode analysis confirms the grid-forming benefit of increased damping; decreased damping is observed at shares above 80%, but not at 100%. Finally, simulations on a validated Maui power system model with a 96% of inverter-based resources model yield a trend toward a first-order response.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Workshop Summary: Bridging the Gap Between Atmospheric Science and Grid Integration

The need for dedicated, accurate, expertly curated weather data is increasingly important as the share of variable renewable energy increases on the power system. Projections for futures with very high (50+% annual energy) shares of variable generation require ongoing assessment of data requirements from industry stakeholders in their power system operation and planning contexts. In March 2024, NREL organized a workshop entitled "Bridging the Gap Between Atmospheric Science and Grid Integration Workshop", which brought atmospheric scientists and power system experts together to refine the requirements of atmospheric datasets for grid integration, and to describe a holistic approach to creating new and regularly updated national scale wind datasets for power system planning and operations. The results of this workshop are being used to inform the near-term development and a longer-term strategy for DOE to produce relevant wind resource datasets and inform wider use of wind/solar/load data sets in power system planning. This presentation provides an overview of a preworkshop survey, an assessment of current state of the art of national-scale datasets for wind resource assessment and grid integration, insights on appropriate uses of the WTK-LED, power system perspectives on data needs, as well as recommended next steps as discussed in the workshop and how these steps support longer-term strategies.

17 WIND ENERGY↗

Development of Renewable Energy Data for Facilitating the Clean Energy Transition in Vietnam

Vietnam is transforming its power system with an increasing share of variable renewable energy (VRE) in the generation mix and plans to achieve 27% VRE by capacity in 2030 and 42% by capacity in 2045, as indicated by the draft Eighth Power Development Plan for 2020–-2045 (PDP8). Further increase in VRE penetration is possible with data-driven analysis where availability of data, specifically VRE data, becomes critical. NREL has worked with various stakeholders in Vietnam to create high-resolution multi-year VRE data publicly available to all. This paper reviews this new VRE data for Vietnam and how different stakeholders can use this data to inform VRE deployment decisions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Harmonic Modeling, Data Generation and Analysis of Power Electronics-Interfaced Residential Loads

The share of electronics-based residential load is expected to rise as devices such as variable frequency drives (VFDs), electric vehicle chargers, and inverter-based distributed energy resources (DERs), e.g., photovoltaic (PV) systems become more common. These loads may introduce significant harmonics into power networks that need to be closely studied in order to perform accurate load modeling and forecasting. However, it can be difficult to obtain harmonic-rich voltage and current data - necessary for identifying accurate load models - for residential electrical loads. Recognizing this need, we identify and model a set of electronics-based end-use loads and DERs in an electromagnetic transients program (EMTP) tool for a residence with a single- phase split-phase supply. Further, a procedure is developed to model harmonic interactions between end-use loads connected to the same non-ideal supply voltage in a residential setting. Finally, a harmonic-rich dataset produced via the proposed procedure is utilized to identify frequency coupling matrix (FCM) based load model. Numerical results demonstrate the accuracy of the model, and explore model identifiability with limited data points.

harmonics, power quality, load modeling↗

Scaling Up CSP: How Long Will it Take?

Concentrating solar power (CSP) is one of the few scalable technologies capable of delivering dispatchable renewable power. Therefore, many expect it to shoulder a significant share of system balancing in a renewable electricity future powered by cheap, intermittent PV and wind power: the IEA, for example, projects 73 GW CSP by 2030 and several hundred GW by 2050 in its Net-Zero by 2050 pathway. In this paper, we assess how fast CSP can be expected to scale up and how long time it would take to get new, high-efficiency CSP technologies to market, based on observed trends and historical patterns. We find that to meaningfully contribute to net-zero pathways the CSP sector needs to reach and exceed the maximum historical annual growth rate of 30%/year last seen between 2010-2014 and maintain it for at least two decades. Any CSP deployment in the 2020s will rely mostly on mature existing technologies, namely parabolic trough and molten-salt towers, but likely with adapted business models such as hybrid CSP-PV stations, combining the advantages of higher-cost dispatchable and low-cost intermittent power. New third-generation CSP designs are unlikely to play a role in markets during the 2020s, as they are still at or before the pilot stage and, judging from past pilot-to-market cycles for CSP, they will likely not be ready for market deployment before 2030. CSP can contribute to low-cost zero-emission energy systems by 2050, but to make that happen, at the scale foreseen in current energy models, ambitious technology-specific policy support is necessary, as soon as possible and in several countries.

concentrated solar power↗

Evolutionary Architecture Search for Generative Adversarial Networks Based on Weight Sharing

Generative adversarial networks (GANs) are a powerful generative technique but frequently face challenges with training stability. Network architecture plays a significant role in determining the final output of GANs, but designing a fine architecture demands extensive domain expertise. This article aims to address this issue by searching for high-performance generator’s architectures through neural architecture search (NAS). The proposed approach, called evolutionary weight sharing GANs (EWSGAN), is based on weight sharing and comprises two steps. First, a supernet of the generator is trained using weight sharing. Second, a multiobjective evolutionary algorithm (MOEA) is employed to identify optimal subnets from the supernet. These subnets inherit weights directly from the supernet for fitness assessment. Two strategies are used to stabilize the training of the generator supernet: 1) a fair single-path sampling strategy and 2) a discarding strategy. Experimental results indicate that the architecture searched by our method achieved a new state-of-the-art among NAS–GAN methods with a Fréchet inception distance (FID) of 9.09 and an inception score (IS) of 8.99 on the CIFAR-10 dataset. Finally, it also demonstrates competitive performance on the STL-10 dataset, achieving FID of 21.89 and IS of 10.51.

97 MATHEMATICS AND COMPUTING↗