Search NASASearch

SEARCH · Search NASA

Results for “power system reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,575 records · Page 9

Solar Array Automation Limitations

Significant progress in the automation of the spacecraft electrical power systems has been made within the past few years. This is especially important with the development of the space station and the increasing demand on the electrical power systems for future satellites. The key element of the spacecraft power system, the solar arrays which supply the power, will have to grow to supply many tens of kilowatts of power within the next twenty years. This growth will be accompanied by the problems associated with large distributed power systems. The growth of the arrays, the on-array management problems and potential solutions to array degradation or failure are discussed. Multilowatt arrays for unmanned spacecraft with comments on the implications of array degradation for manned spacecraft are discussed.

Terry M Trumble

Orbiting Solar Observatory Battery and Power Design

The OSO-1 represents a recent vintage satellite, or more recent design satellite. A summary of the battery design used on OSO-1 is presented. The temperature effects on voltage and charging-discharging of the battery system are discussed.

F E Ford

Anticipating Optical Availability in Hybrid RF/FSO Links Using RF Beacons and Deep Learning

Radiofrequency (RF) communications offer reliable but low data rates and energy-inefficient satellite links, while free-space optical (FSO) promises high bandwidth but struggles with disturbances imposed by atmospheric effects. A hybrid RF/FSO architecture aims to achieve optimal reliability along with high data rates for space communications. Accurate prediction of dynamic ground-to-satellite FSO link availability is critical for routing decisions in low-earth orbit constellations. In this paper, we propose a system leveraging ubiquitous RF links to proactively forecast FSO link degradation prior to signal drops below threshold levels. This enables pre-calculation of rerouting to maximally maintain high data rate FSO links throughout the duration of weather effects. We implement a supervised learning model to anticipate FSO attenuation based on the analysis of RF patterns. Through the simulation of a dense lower earth orbit (LEO) satellite constellation, we demonstrate the efficacy of our approach in a simulated satellite network, highlighting the balance between predictive accuracy and prediction duration. An emulated cloud attenuation model is proposed to provide insight into the temporal profiles of RF signals and their correlation to FSO channel dynamics. Our investigation sheds light on the trade-offs between prediction horizon and accuracy arising from RF beacon numbers and proximity.

FSO availability

Thermal Cycle and Capacitance Testing of Mezzo Industries Phase Changer Material Heat Capacitor

Effective Thermal management is essential for the safety and performance of human spacecraft, especially during long-duration missions with fluctuating heat loads. Phase Change Material (PCM) heat exchangers offer a compact, efficient solution by storing and releasing thermal energy through latent heat during phase transitions. This allows PCM systems to buffer transient thermal loads without immediate heat rejection, reducing the need for oversized radiators – particularly critical during ascent and re-entry when radiators are stowed. By maintaining stable temperatures in crew cabins and equipment bays, PCM technology enhances crew comfort, protects sensitive systems, and supports long-term mission sustainability with minimal mass and volume impact. A phase change material heat capacitor prototype, designed and built under a NASA Small Business Innovation Research grant by Mezzo Technologies, utilizes a laser welding microtube manufacturing process that promises increased reliability and performance over current manufacturing methods like brazing. This heat exchanger was tested through coolant thermal cycling within the expected flow rates and temperature range of the Orion spacecraft, the crewed spacecraft taking NASA astronauts to the moon under the Artemis Program. The useful heat storage capacitance was measured and compared to Orion spacecraft requirements.

Active Thermal Control Systems

Hazard and risk analysis framework for nuclear power plant–based integrated energy systems

Employing integrated energy systems (IESs) with nuclear power plants (NPPs) can improve NPP utilization by leveraging dedicated thermal and electric power delivery, but it may also increase operational safety risks. This paper presents a framework to identify and quantify hazards and risks for such IESs. The framework combines accidentology to review past industrial accidents with failure modes and effects analysis (FMEA) to identify potential future incidents. Hydrogen explosion and toxic chemical release hazards are of particular concern. Explosion consequences are quantified using the Bauwens-Dorofeev (Bauwens) and trinitrotoluene equivalent mass (TNT-EM) methods, while chemical release consequences are computed using the Gaussian atmospheric dispersion method. Operational disturbances from direct electrical and thermal integration that may affect NPP safety are modeled using probabilistic risk analysis (PRA). Hazards and risks are then evaluated for regulatory compliance. The framework is applied to IESs comprising pressurized or boiling water reactors supplying three levels of thermal and electrical power to industrial customers. Case studies include high-temperature steam electrolysis hydrogen plants of varying capacities and a synthetic fuel production plant. Sensitivity analysis examines piping component failures in the PRA model as a precursor to cost estimation for thermal extraction line design. Additionally, Fussel-Vessely (FV) and risk increase importance (RII) measures identify risk-informed design improvements for the thermal extraction system. FMEA highlights hazards such as loss of offsite power, prompt loss of electrical load, loss of thermal output, and immediate steam diversion, in addition to hydrogen explosions and toxic chemical releases. Both Bauwens and TNT-EM methods suggest maintaining several hundred meters of separation between the NPP and hydrogen facility to mitigate explosion risks. PRA results show a maximum initiating event frequency increase of 1.15% and an overall risk increase of 0.28%. Importance measure analysis identifies upstream pipe leak isolation components as critical. Evaluating the results against safety regulations, it is concluded that hazards and risks can be managed to comply with regulations through risk-informed thermal and electrical connection designs, component selection, maintenance programs, and safe separation distances between NPPs and integrated industrial facilities.

08 - HYDROGEN

NIAC Phase I Final Report Lunar South Pole Oxygen Pipeline (LSPOP)

The Lunar South Pole Oxygen Pipeline (LSPOP) Phase I NIAC, is to analyze the feasibility of constructing a pipeline at the Moon’s South Pole for transporting gaseous oxygen from point of generation to point of use. A lunar pipeline has never been pursued and will revolutionize lunar surface operations for the Artemis program and reduce cost and risk. Our starting concept is for a 5 km pipeline to transport oxygen gas from an oxygen production source, for example from our molten regolith electrolysis (MRE, currently at TRL 5, see references[1],[2],[3],[4],[5],[6] for technical discussions of the MRE process) extraction site, or any other source, to an oxygen storage/liquification plant near a lunar base. The pipeline is designed to: 1) be constructed robotically from regolith-derived metals with minimal material transferred from Earth, 2) be repairable robotically, 3) have an oxygen flow rate of ~2 kg/hour, which is commensurate with the NASA initial projected need of 10,000 kg/year, 4) operate with minimal power over the lifetime of the pipeline, with a goal of high operational reliability and the ability to survive in the lunar environment for > 10 years. We compare this concept to a pipeline concept with pipe produced on Earth and then transported to and assembled on the Moon. Both approaches will use earth-based compressors, valves, and fittings which are integrated into the pipeline on the Moon.

NIAC Phase I

Ejecta Management in a Safe Lithium Ion Battery Design

As lithium-ion battery energy densities continue to rise, managing the heat and pressure generated during failure events has become increasingly critical. Safety systems must effectively relieve pressure without releasing sparks, flames, or particulate matter, requiring robust filtration solutions. The challenge is compounded by the reduced free volume available for gas expansion in high-density designs, which increases the demands on these filters. While significant progress has been made through experimental studies and modeling efforts to understand the behavior of ejecta during battery failures, there remains a pressing need for practical, rule-of-thumb sizing parameters. These parameters would help correlate high-energy waste streams with appropriate filter design, ensuring reliable containment and safety. This talk will explore recent experimental findings in this area and discuss the potential pathways for developing these essential sizing guidelines.

Ejecta Management

Ultrasonic Washer–Dryer System for Space Habitats: Design Upgrades and Parabolic Flight Readiness

Clothing makes up nearly 25% of all non-food supplies sent to the International Space Station (ISS). To support sustainable human missions in deep space, NASA’s Life Support and Habitation Systems Focus Area looks to advance technologies to support and improve logistics. Our team is creating a compact ultrasonic clothing washer/dryer system that bypasses traditional limitations and is suitable for space. Thermal drying uses a lot of energy to evaporate water, while our ultrasonic drying method offers a quicker, more efficient alternative. It uses piezoelectric transducers to vibrate textiles at the micron scale, mechanically removing water as cold mist rather than evaporating it. This speeds up drying and reduces energy use, no matter the fabric makeup. This paper details recent upgrades to a full-scale ultrasonic washer–dryer system, readying it for parabolic flight testing. Improvements include an enhanced human–machine interface, better packaging, and optimized performance and control. We also present extensive pre-flight ground tests conducted to ensure reliability and identify potential risks. Collaborating with P&G, we report preliminary cleaning tests using various detergents. These results lay a crucial foundation for the laundry system designed specifically for space. By cutting clothing-related payload and waste by over 97%, this technology supports long-term human exploration missions on the ISS, the Moon, Mars, and beyond.

Laundry

International Space Station Lithium-Ion Battery

The International Space Station (ISS) Electric Power System (EPS) currently uses Nickel-Hydrogen (Ni-H2) batteries to store electrical energy. The batteries are charged during insolation and discharged during eclipse. The Ni-H2 batteries are designed to operate at a 35 depth of discharge (DOD) maximum during normal operation in a Low Earth Orbit. Since the oldest of the 48 Ni-H2 battery Orbital Replacement Units (ORUs) has been cycling since September 2006, these batteries are now approaching their end of useful life. In 2010, the ISS Program began the development of Lithium-Ion (Li-ion) batteries to replace the Ni-H2 batteries and concurrently funded a Li-ion cell life testing project. This paper will include an overview of the ISS Li-Ion battery system architecture and the progress of the Li-ion battery design and development.

Battery

Americium-Fuelled Radioisotope Stirling Generator Elegant Breadboard

High power solutions for spacecraft are becoming increasingly sought after in the new era of space exploration, with energy intensive in-situ lunar surface exploration becoming a key part of the roadmap for major space agencies, as well as commercial companies. Nuclear power provides the most feasible solution to achieve continued operation through the long lunar night, and in extended periods in Permanently Shadowed Regions (PSRs). Americium-241 (241Am) is used as the fuel of choice in European Radioisotope Power Systems (RPS). The University of Leicester have developed a number of systems using this fuel type, including a 200 Wth heat source. Building on existing international partnerships, the University of Leicester is continuing to work with NASA Glenn Research Center (GRC) to maximise the electrical output that can be generated from the heat source by progressing the radioisotope-Stirling generator concept to elegant breadboard level, building on the long heritage of dynamic power conversion developments at NASA Glenn. Presented in the following conference paper is the next iteration of the Americium-fuelled Radioisotope Stirling Generator (Am-RSG) Elegant Breadboard, following on from a successful technology demonstration design conducted at NASA Glenn in early 2025. The design laid-out in this paper is a more flight-like version of the technology demonstrator, and is intended to pair with the next generation of Stirling convertor technology, the SunPower Robust Stirling Converter (SRSC). The SRSC is able to operate more efficiently at lower thermal power levels than the previous Advanced Stirling Convertor (ASC), making it more suitable for the 241Am system.

Lunar

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Ultrasonic Washer–Dryer System for Space Habitats: Design Upgrades and Parabolic Flight Readiness

Clothing makes up nearly 25% of all non-food supplies sent to the International Space Station (ISS). To support sustainable human missions in deep space, NASA’s Life Support and Habitation Systems Focus Area looks to advance technologies to support and improve logistics. Our team is creating a compact ultrasonic clothing washer/dryer system that bypasses traditional limitations and is suitable for space. Thermal drying uses a lot of energy to evaporate water, while our ultrasonic drying method offers a quicker, more efficient alternative. It uses piezoelectric transducers to vibrate textiles at the micron scale, mechanically removing water as cold mist rather than evaporating it. This speeds up drying and reduces energy use, no matter the fabric makeup. This paper details recent upgrades to a full-scale ultrasonic washer–dryer system, readying it for parabolic flight testing. Improvements include an enhanced human–machine interface, better packaging, and optimized performance and control. We also present extensive pre-flight ground tests conducted to ensure reliability and identify potential risks. Collaborating with P&G, we report preliminary cleaning tests using various detergents. These results lay a crucial foundation for the laundry system designed specifically for space. By cutting clothing-related payload and waste by over 97%, this technology supports long-term human exploration missions on the ISS, the Moon, Mars, and beyond.

Ultrasonic

EMU battery/SMM power tool characterization study

The power tool which will be used to replace the attitude control system in the SMM spacecraft was modified to operate from a self contained battery. The extravehicular mobility unit (EMU) battery was tested for the power tool application. The results are that the EMU battery is capable of operating the power tool within the pulse current range of 2.0 to 15.0 amperes and battery temperature range of -10 to 40 degrees Celsius.

Palandati, C.

Building Operation Model (Morpheus) for Dallas Fort Worth Airport (CRADA CRD-19-16301 Final Report)

The primary objective of this project was to leverage digital twin technology to enhance the design and operation of DFW Airport terminals and their associated energy systems. To achieve this, Morpheus, a building digital twin, was developed to guide improvements in airport operations, specifically targeting reductions in peak power demand and overall energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

An Analysis of Energy Needs and Seawater Extraction Approaches for the Integration of Primary Magnesium Production with Nuclear Power

The cost of primary magnesium production is highly dominated by the energy required to produce the metal. This, along with the current geographical concentration of its production, makes the magnesium price vulnerable as energy-production paradigms begin to rapidly change. In this work, four nuclear-integration pathways for the efficient supply of heat and electricity to magnesium production from a nuclear power plant are considered. A production route using electrified metallothermic reduction is compared to a nuclear-heat-integrated electrolytic pathway. It is shown that the latter can achieve significantly lower primary energy consumption, 261 MJ/kg Mg compared with 416 MJ/kg Mg. The electrolytic pathway can also reduce emissions down to around 2.1 kgCO2/kg Mg, compared to around 34 kgCO2/kg Mg in the Pidgeon process. Beyond energy and emissions, the four pathways considered are also compared to their ability to reduce locational dependence of the production plant and reduce process complexity. This work also highlights future advances in magnesium production with a potential scheme for the efficient extraction of magnesium from seawater with coproduction of desalinated water and the potential of demand-side response from magnesium electrolysis. This is the first work to consider the full integration of primary magnesium production using nuclear cogeneration, and it is hoped the study paves the way for the analysis of economic nuclear integration within metal extraction and manufacturing.

22 - GENERAL STUDIES OF NUCLEAR REACTORS

Technology Readiness Assessment for Stirling Power Convertor

Stirling-based power conversion system could represent a critical enabling technology for future NASA missions, offering significantly enhanced power efficiency over traditional thermoelectric systems. To ensure the successful infusion of this technology into deep space and planetary surface missions, a rigorous evaluation of its maturity and associated risks is essential. The objective of this Technology Readiness Assessment (TRA) is to determine the current technology readiness level (TRL) of the Stirling power convertor and identify key technical risks and challenges associated with its maturation and potential infusion into a targeted flight system. The evaluation process will rigorously follow the NASA TRA procedure: (1) determining the requirements that underpin the design, function, and performance; (2) finding and listing all new technology elements (NTEs) and critical technology elements (CTEs); (3) identifying the level of integration assumed for the assessment; and (4) assessing the TRL for each NTE and CTE. The overall subassembly TRL will then be determined via a roll-up using the “weakest link” criterion, culminating in a final (5) assessment of risks to further progression of maturity. This paper will present the results of a comprehensive technology readiness assessment (TRA) conducted on the Stirling-based dynamic power conversion subassembly, excluding the radioisotope heat source. The paper will also describe a detailed breakdown of the TRL roll-up and a matrix of identified risks and recommended mitigation paths, along with identified key technical risks and challenges to achieve the required long-duration performance. Key Words: Radioisotope Power Conversion, Technology Readiness Assessment

Radioisotope Power Conversion

Center for High-Efficiency Electrical Technologies for Aircraft: Phase I Final Report

Under the University Leadership Initiative (ULI), the Center for High-Efficiency for Electrical Technologies (CHEETA) was established to develop and mature early-stage technologies pertaining to hydrogen-electric power and energy systems for aircraft. In particular, integration of these technologies on an aircraft system is envisioned to leverage the high specific energy content of liquid hydrogen (LH2) with fuel cell energy conversion and an electrically driven ducted fan system to provide an ultra-efficient propulsion drivetrain. For this concept, the LH2 system is not just used as an energy storage mechanism, but also as a cryogen to enable highly efficient superconducting electric systems. The end result of this concept is an integrated aircraft system with a quiet, efficient propulsion architecture that produces zero CO2, NOx, SOx, and particulate matter emissions at the vehicle level.

Hydrogen

Modeling the Potential Impact of Storage on the US Power Sector in a Multisector Dynamic Context

The electric power sector is expected to grow in size, importance, and complexity around the world as economies expand and electric supply technologies and demand patterns evolve in significant ways. At the same time the electric power sector may see substantial increases in VRE generating technologies which can add variability and uncertainty to the diurnal and seasonal profile of electric supply. With these forces in play, the emergence of modular, flexible electricity storage technologies may have profound impacts on the operation of electric power systems. Here we reduce a storage modeling gap in MSD models by incorporating grid-based electricity storage into the electric sector dynamics of the Global Change Analysis Model-USA (GCAM-USA) with improved power sector representation. We find a potentially significant role for storage technologies in the future of the U.S. power system, with storage capacity ranging from 7.7 to 14.7 GW in 2050 and 13.9 to 31.6 GW in 2100 across several techno-economic scenarios. We also find that storage can help to smooth variability in residual load arising from evolving electricity demands and the introduction of high shares of VRE to the electric grid. This reduces reliance on high-cost peaking generators, improves system-wide capacity factors, and limits curtailment of VRE.

Patel, Pralit L.