Search NASA⌕ Search

SEARCH · Search NASA

Results for “pressure scale”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

A graphics package for meteorological data, version 1.5

A plotting package has been developed to simplify the task of plotting meteorological data. The calling sequences and examples of high level yet flexible routines which allow contouring, vectors and shading of cylindrical, polar, orthographic and Mollweide (egg) projections are given. Routines are also included for contouring pressure-latitude and pressure-longitude fields with linear or log scales in pressure (interpolation to fixed grid interval is done automatically). Also included is a fairly general line plotting routine. The present version (1.5) produces plots on WMS laser printers and uses graphics primitives from WOLFPLOT.

Moorthi, Shrinivas↗

Experimental and analytical study of cryogenic propellant boiloff to develop and verify alternate pressurization concepts for Space Shuttle external tank using a scaled down tank

Self pressurization by propellant boiloff is experimentally studied as an alternate pressurization concept for the Space Shuttle external tank (ET). The experimental setup used in the study is an open flow system which is composed of a variable area test tank and a recovery tank. The vacuum jacketed test tank is geometrically similar to the external LOx tank for the Space Shuttle. It is equipped with instrumentation to measure the temperature and pressure histories within the liquid and vapor, and viewports to accommodate visual observations and Laser-Doppler Anemometry measurements of fluid velocities. A set of experiments were conducted using liquid Nitrogen to determine the temperature stratification in the liquid and vapor, and pressure histories of the vapor during sudden and continuous depressurization for various different boundary and initial conditions. The study also includes the development and calibration of a computer model to simulate the experiments. This model is a one-dimensional, multi-node type which assumes the liquid and the vapor to be under non-equilibrium conditions during the depressurization. It has been tested for a limited number of cases. The preliminary results indicate that the accuracy of the simulations is determined by the accuracy of the heat transfer coefficients for the vapor and the liquid at the interface which are taken to be the calibration parameters in the present model.

Akyuzlu, K. M.↗

Global Autocorrelation Scales of the Partial Pressure of Oceanic CO2

A global database of approximately 1.7 million observations of the partial pressure of carbon dioxide in surface ocean waters (pCO2) collected between 1970 and 2003 is used to estimate its spatial autocorrelation structure. The patterns of the lag distance where the autocorrelation exceeds 0.8 is similar to patterns in the spatial distribution of the first baroclinic Rossby radius of deformation indicating that ocean circulation processes play a significant role in determining the spatial variability of pCO2. For example, the global maximum of the distance at which autocorrelations exceed 0.8 averages about 140 km in the equatorial Pacific. Also, the lag distance at which the autocorrelation exceed 0.8 is greater in the vicinity of the Gulf Stream than it is near the Kuroshio, approximately 50 km near the Gulf Stream as opposed to 20 km near the Kuroshio. Separate calculations for times when the sun is north and south of the equator revealed no obvious seasonal dependence of the spatial autocorrelation scales. The pCO2 measurements at Ocean Weather Station (OWS) 'P', in the eastern subarctic Pacific (50 N, 145 W) is the only fixed location where an uninterrupted time series of sufficient length exists to calculate a meaningful temporal autocorrelation function for lags greater than a few days. The estimated temporal autocorrelation function at OWS 'P', is highly variable. A spectral analysis of the longest four pCO2 time series indicates a high level of variability occurring over periods from the atmospheric synoptic to the maximum length of the time series, in this case 42 days. It is likely that a relative peak in variability with a period of 3-6 days is related to atmospheric synoptic period variability and ocean mixing events due to wind stirring. However, the short length of available time series makes identifying temporal relationships between pCO2 and atmospheric or ocean processes problematic.

Li, Zhen↗

Pressure distributions on a 0.04-scale model of the Space Shuttle Orbiter's forward fuselage in the Langley unitary plan wind tunnel

Pressure distribution tests on a 0.04-scale model of the forward fuselage of the Space Shuttle Orbiter are presented without analysis. The tests were completed in the Langley Unitary Plan Wind Tunnel (UPWT). The UPWT has two different test sections operating in the continuous mode. Each test section has its own Mach number range. The model was tested at angles of attack from -2.5 deg to 30 deg and angles of sideslip from -5 deg to 5 deg in both test sections. The test Reynolds number was 6.6 x 10 to the 6th power per meter. The tests were conducted in support of the development of the Shuttle Entry Air Data System (SEADS). In addition to modeling the 20 SEADS pressure orifices, the wind-tunnel model was also instrumented with orifices to match Development Flight Instrumentation (DFI) port locations currently existing on the Space Shuttle Orbiter Columbia (OV-102). This DFI simulation has provided a means for comparisons between reentry flight pressure data and wind-tunnel data.

Bradley, P. F.↗

New considerations on scale extrapolation of wing pressure distributions affected by transonic shock-induced separations

Use of this analytical parameter, it is shown, highlights the distinction between cases which are dominated by trailing-edge separation, and those for which separation at the shock foot is dominant. Use of the analytical parameter and the distinction noted above greatly improves the correlation of separation data and the extrapolation of wind tunnel data to flight conditions.

Kahn, M. M. S.↗

Luminescent Paints Used for Rotating Temperature and Pressure Measurements on Scale-Model High-Bypass-Ratio Fans

NASA Lewis Research Center is a leader in the application of temperature- and pressuresensitive paints (TSP and PSP) in rotating environments. Tests were recently completed on several scale model, high-bypass-ratio turbofans in Lewis' 9- by 15-Foot Low-Speed Wind Tunnel. Two of the test objectives were to determine the aerodynamic and acoustic performance of the fan designs. Using TSP and PSP, researchers successfully achieved fullfield aerodynamic loading profiles. The visualized loading profiles may help researchers identify factors contributing to the fans' performance and to the acoustic characteristics associated with the flow physics on the surface of the blades.

Bencic, Timothy J.↗

A priori testing of subgrid-scale models for the velocity-pressure and vorticity-velocity formulations

Subgrid-scale models for Large Eddy Simulation (LES) in both the velocity-pressure and the vorticity-velocity formulations were evaluated and compared in a priori tests using spectral Direct Numerical Simulation (DNS) databases of isotropic turbulence: 128(exp 3) DNS of forced turbulence (Re(sub(lambda))=95.8) filtered, using the sharp cutoff filter, to both 32(exp 3) and 16(exp 3) synthetic LES fields; 512(exp 3) DNS of decaying turbulence (Re(sub(Lambda))=63.5) filtered to both 64(exp 3) and 32(exp 3) LES fields. Gaussian and top-hat filters were also used with the 128(exp 3) database. Different LES models were evaluated for each formulation: eddy-viscosity models, hyper eddy-viscosity models, mixed models, and scale-similarity models. Correlations between exact versus modeled subgrid-scale quantities were measured at three levels: tensor (traceless), vector (solenoidal 'force'), and scalar (dissipation) levels, and for both cases of uniform and variable coefficient(s). Different choices for the 1/T scaling appearing in the eddy-viscosity were also evaluated. It was found that the models for the vorticity-velocity formulation produce higher correlations with the filtered DNS data than their counterpart in the velocity-pressure formulation. It was also found that the hyper eddy-viscosity model performs better than the eddy viscosity model, in both formulations.

Winckelmans, G. S.↗

Fan Noise Source Diagnostic Test: Vane Unsteady Pressure Results

To investigate the nature of fan outlet guide vane pressure fluctuations and their link to rotor-stator interaction noise, time histories of vane fluctuating pressures were digitally acquired as part of the Fan Noise Source Diagnostic Test. Vane unsteady pressures were measured at seven fan tip speeds for both a radial and a swept vane configuration. Using time-domain averaging and spectral analysis, the blade passing frequency (BPF) harmonic and broadband contents of the vane pressures were individually analyzed. Significant Sound Pressure Level (SPL) reductions were observed for the swept vane relative to the radial vane for the BPF harmonics of vane pressure, but vane broadband reductions due to sweep turned out to be much smaller especially on an average basis. Cross-correlation analysis was used to establish the level of spatial coherence of broadband pressures between different locations on the vane and integral length scales of pressure fluctuations were estimated from these correlations. Two main results of this work are: (1) the average broadband level on the vane (in dB) increases linearly with the fan tip speed for both the radial and swept vanes, and (2) the broadband pressure distribution on the vane is nearly homogeneous and its integral length scale is a monotonically decreasing function of fan tip speed.

Envia, Edmane↗

An investigation to determine the static pressure distribution of the 0.00548 scale shuttle solid rocket booster (MSFC model number 468) during reentry in the NASA/MSFC 14 inch trisonic wind tunnel (SA28F)

The results of a pressure test of a .00548 scale 146 inch Space Shuttle Solid Rocket Booster (SRB) with and without protuberances, conducted in a 14 x 14 inch trisonic wind tunnel are presented. Static pressure distributions for the SRB at reentry attitudes and flight conditions were obtained. Local longitudinal and ring pressure distributions are presented in tabulated form. Integration of the pressure data was performed. The test was conducted at Mach numbers of 0.40 to 4.45 over an angle of attack range from 60 to 185 degrees. Roll angles of 0, 45, 90 and 315 degrees were investigated. Reynolds numbers per foot varied for selected Mach numbers.

Braddock, W. F.↗

Pressure signatures for a .00053 scale model of the Saturn 5-Apollo launch vehicle with simulated exhaust plumes

Wind tunnel pressure signatures are presented for 10 Mach numbers over a range from 3.01 to 7.29 for a .00053-scale model of the Saturn 5 Apollo launch vehicle complete with escape tower and solid body simulated exhaust plumes for each Mach number. The effect of simulated plume length on the wind tunnel pressure signature was investigated at Mach 4.01. An analysis of the error incurred by extrapolating pressure signatures having strong shock waves by weak shock procedures is presented.

Hicks, R. M.↗

Ares I Scale Model Acoustic Tests Instrumentation for Acoustic and Pressure Measurements

The Ares I Scale Model Acoustic Test (ASMAT) was a development test performed at the Marshall Space Flight Center (MSFC) East Test Area (ETA) Test Stand 116. The test article included a 5% scale Ares I vehicle model and tower mounted on the Mobile Launcher. Acoustic and pressure data were measured by approximately 200 instruments located throughout the test article. There were four primary ASMAT instrument suites: ignition overpressure (IOP), lift-off acoustics (LOA), ground acoustics (GA), and spatial correlation (SC). Each instrumentation suite incorporated different sensor models which were selected based upon measurement requirements. These requirements included the type of measurement, exposure to the environment, instrumentation check-outs and data acquisition. The sensors were attached to the test article using different mounts and brackets dependent upon the location of the sensor. This presentation addresses the observed effect of the sensors and mounts on the acoustic and pressure measurements.

Vargas, Magda B.↗

Aeroheating (pressure) characteristics on a 0.10-scale version of the vehicle 3 space shuttle configuration (26-OTS) in the Langley Research Center 4-foot wind tunnel (IH4)

Results of wind tunnel tests, conducted at the Langley Research Center Unitary Plan Wind Tunnel, are presented. The model tested was an 0.010-scale version of the Vehicle 3 Space Shuttle Configuration. Pressure measurements were made on the launch configuration, Orbiter alone, external tank alone, and solid rocket booster alone, to provide heat transfer pressure data. The tests were conducted for a Mach number range from 2.36 to 4.6 and Reynolds number range from 1.2 to 5 million per foot. The model was tested at angles of attack from -10 to 20 deg for a sideslip angle range from -5 to +5 deg, and at sideslip angles from -5 to 48 deg for 0 deg angle of attack. Tabulated data are given and photographs of the test configuration are shown.

Kingsland, R. B.↗

The Titan haze revisted: Magnetospheric energy sorces quantitative tholin yields

We present laboratory measurements of the radiation yields of complex organic solids produced from N2/CH4 gas mixtures containing 10 or 0.1% CH4. These tholins are thought to resemble organic aerosols produced in the atmospheres of Titan, Pluto, and Triton. The tholin yields are large compared to the total yield of gaseous products: nominally, 13 (C + N)/100 eV for Titan tholin and 2.1 (C + N)/100 eV for Triton tholin. High-energy magnetospheric electrons responsible for tholin production represents a class distinct from the plasma electrons considered in models of Titan's aiglow. Electrons with E greater than 20 keV provide an energy flux approximately 1 x 10(exp -2) erg/cm/sec, implying from our measured tholin yields a mass flux of 0.5 to 4.0 x 10(exp -14) g/sq cm/sec of tholin. (The corresponding thickness of the tholin sedimentary column accumulated over 4 Gyr on Titan's surface is 4 to 30 m). This figure is in agreement with required mass fluxes computed from recent radiative transfer and sedimentation models. If, however, theses results, derived from experiments at approximately 2 mb, are applied to lower pressure levels toward peak auroral electron energy deposition and scaled with pressure as the gas-phase organic yields, the derived tholin mass flux is at least an order of magnitude less. We attrribute this difference to the fact that tholin synthesis occurs well below the level of maximum electron energy depositon and to possible contributions to tholis from UV-derived C2-hydrocarbons. We conclude that Tita tholin, produced by magnetospheric electrons, is alone sufficient to supply at least a significant fraction of Titan's haze-a result consistent with the fact that the optical properties of Titan tholin, among all proposed material, are best at reproducing Titan's geometric albedo spectrum from near UV to mid-IR in light-scattering models.

Thompson, W. Reid↗

The Titan haze revisited: magnetospheric energy sources and quantitative tholin yields

We present laboratory measurements of the radiation yields of complex organic solids produced from N2/CH4 gas mixtures containing 10 or 0.1% CH4. These tholins are thought to resemble organic aerosols produced in the atmospheres of Titan, Pluto, and Triton. The tholin yields are large compared to the total yield of gaseous products: nominally, 13 (C + N)/100 eV for Titan tholin and 2.1 (C + N)/100 eV for Triton tholin. High-energy magnetospheric electrons responsible for tholin production represent a class distinct from the plasma electrons considered in models of Titan's airglow. Electrons with E > 20 keV provide an energy flux approximately 1 x 10(-2) erg cm-2 sec-1, implying from our measured tholin yields a mass flux of 0.5 to 4.0 x 10(-14) g cm-2 sec-1 of tholin. (The corresponding thickness of the tholin sedimentary column accumulated over 4 Gyr on Titan's surface is 4 to 30 m.) This figure is in agreement with required mass fluxes computed from recent radiative transfer and sedimentation models. If, however, these results, derived from experiments at approximately 2 mb, are applied to lower pressure levels toward peak auroral electron energy deposition and scaled with pressure as the gas-phase organic yields, the derived tholin mass flux is at least an order of magnitude less. We attribute this difference to the fact that tholin synthesis occurs well below the level of maximum electron energy deposition and to possible contributions to tholins from UV-derived C2-hydrocarbons. We conclude that Titan tholin, produced by magnetospheric electrons, is alone sufficient to supply at least a significant fraction of Titan's haze--a result consistent with the fact that the optical properties of Titan tholin, among all proposed materials, are best at reproducing Titan's geometric albedo spectrum from near UV to mid-IR in light-scattering models.

Non-NASA Center↗

Optical zero-differential pressure switch and its evaluation in a multiple pressure measuring system

The design of a clamped-diaphragm pressure switch is described in which diaphragm motion is detected by a simple fiber-optic displacement sensor. The switch was evaluated in a pressure measurement system where it detected the zero crossing of the differential pressure between a static test pressure and a tank pressure that was periodically ramped from near zero to fullscale gage pressure. With a ramping frequency of 1 hertz and a full-scale tank pressure of 69 N/sq cm gage (100 psig), the switch delay was as long as 2 milliseconds. Pressure measurement accuracies were 0.25 to 0.75 percent of full scale. Factors affecting switch performance are also discussed.

Powell, J. A.↗

Influence of heat transfer rates on pressurization of liquid/slush hydrogen propellant tanks

A multi-dimensional computational model of the pressurization process in liquid/slush hydrogen tank is developed and used to study the influence of heat flux rates at the ullage boundaries on the process. The new model computes these rates and performs an energy balance for the tank wall whereas previous multi-dimensional models required a priori specification of the boundary heat flux rates. Analyses of both liquid hydrogen and slush hydrogen pressurization were performed to expose differences between the two processes. Graphical displays are presented to establish the dependence of pressurization time, pressurant mass required, and other parameters of interest on ullage boundary heat flux rates and pressurant mass flow rate. Detailed velocity fields and temperature distributions are presented for selected cases to further illuminate the details of the pressurization process. It is demonstrated that ullage boundary heat flux rates do significantly effect the pressurization process and that minimizing heat loss from the ullage and maximizing pressurant flow rate minimizes the mass of pressurant gas required to pressurize the tank. It is further demonstrated that proper dimensionless scaling of pressure and time permit all the pressure histories examined during this study to be displayed as a single curve.

Sasmal, G. P.↗