Search NASA⌕ Search

SEARCH · Search NASA

Results for “pressurized balloons”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Spine immobilization apparatus

The apparatus makes use of a normally flat, flexible bladder filled with beads or micro-balloons that form a rigid mass when the pressure within the bladder is decreased below ambient through the use of a suction pump so that the bladder can be conformed to the torso of the victim and provide the desired restraint. The bladder is strapped to the victim prior to being rigidified by an arrangement of straps which avoid the stomach area. The bladder is adapted to be secured to a rigid support, i.e., a rescue chair, so as to enable removal of a victim after the bladder has been made rigid. A double sealing connector is used to connect the bladder to the suction pump and a control valve is employed to vary the pressure within the bladder so as to soften and harden the bladder as desired.

Lambson, K. H.↗

Improved Calibration Of Acoustic Plethysmographic Sensors

Improved method of calibration of acoustic plethysmographic sensors involves acoustic-impedance test conditions like those encountered in use. Clamped aluminum tube holds source of sound (hydrophone) inside balloon. Test and reference sensors attached to outside of balloon. Sensors used to measure blood flow, blood pressure, heart rate, breathing sounds, and other vital signs from surfaces of human bodies. Attached to torsos or limbs by straps or adhesives.

Zuckerwar, Allan J.↗

Intrauterine Pressure (IUP) Telemetry in Pregnant and Parturient Rats: Potential Applications for Spacecraft and Centrifugation Studies

Rats exposed to spaceflight or centrifugation from mid-to late pregnancy undergo either more or fewer labor contractions at birth, respectively, as compared to those in normal Earth gravity (1-g). In this paper, we report the development and validation of a new telemetric method for quantifying intrauterine pressure (IUP) in freely-moving, late pregnant and parturient rats. We plan to utilize this technique for studies of labor in altered gravity, specifically, to ascertain forces of uterine during birth, which we believe may be changed in micro- and hypergravity. The technique we describe yields precise, reliable measures of the forces experienced by rat fetuses during parturition. A small, surgically-implantable telemetric pressure sensor was fitted within a fluid-filled balloon. The total volume of the sensor-balloon assembly matched that of a full term rat fetus. Real-time videorecordings of sensor-implanted rat dams and non- implanted control dams enabled us to characterize effects of the intrauterine implant on behavioral aspects of parturition. Contraction frequency, duration, pup-to-pup birth intervals and pup-oriented activities of the dams measured during the peri-birth period were unaffected by the sensor implant. These findings establish intrauterine telemetry as a reliable, non-invasive technique for quantifying intrauterine pressures associated with parturition on Earth and in altered gravity environments. This new technology, readily amenable to spaceflight and centrifugation platforms, will enable us to answer key questions regarding the role of altered labor frequency labor in the adaptation of newborn mammals to hypo- and hypergravity.

Ronca, A. E.↗

NASA-JSC ozone observations for validation of Nimbus 7-LIMS data

A series of balloon flights undertaken to validate data received from the limb infrared monitor of the stratorphere instrument aboard the Nimbus 7 satellite is discussed. Ozone data profiles, which included altitude, pressure, and mixing ratio, obtained during both ascent and descent of the balloons are reported. The measurement concept, instrumental uncertainties, and temporal variations observed for several time periods are discussed.

Robbins, D. E.↗

Mars Balloon Flight Test Results

This paper describes a set of four Earth atmosphere flight test experiments on prototype helium superpressure balloons designed for Mars. Three of the experiments explored the problem of aerial deployment and inflation, using the cold, low density environment of the Earth's stratosphere at an altitude of 30-32 km as a proxy for the Martian atmosphere. Auxiliary carrier balloons were used in three of these test flights to lift the Mars balloon prototype and its supporting system from the ground to the stratosphere where the experiment was conducted. In each case, deployment and helium inflation was initiated after starting a parachute descent of the payload at 5 Pa dynamic pressure, thereby mimicking the conditions expected at Mars after atmospheric entry and high speed parachute deceleration. Upward and downward looking video cameras provided real time images from the flights, with additional data provided by onboard temperature, pressure and GPS sensors. One test of a 660 cc pumpkin balloon was highly successful, achieving deployment, inflation and separation of the balloon from the flight train at the end of inflation; however, some damage was incurred on the balloon during this process. Two flight tests of 12 m diameter spherical Mylar balloons were not successful, although some lessons were learned based on the failure analyses. The final flight experiment consisted of a ground-launched 12 m diameter spherical Mylar balloon that ascended to the designed 30.3 km altitude and successfully floated for 9.5 hours through full noontime daylight and into darkness, after which the telemetry system ran out of electrical power and tracking was lost. The altitude excursions for this last flight were +/-75 m peak to peak, indicating that the balloon was essentially leak free and functioning correctly. This provides substantial confidence that this balloon design will fly for days or weeks at Mars if it can be deployed and inflated without damage.

deployment↗

Behavioral and Physiological Analyses of Parturition In Pregnant Rats: Insights Derived from Intrauterine Telemetry

During labor and birth, fetuses are exposed to considerable physical stimulation associated with labor contractions and expulsion from the womb These forces are important for the neonates' adaptation to tile extrauterine environment. To further our understanding of the relationship between labor and postpartum outcome, we developed a novel method for measuring intrauterine pressure (IUP) in freely-moving, late pregnant and parturient rats that enables us to make precise, reliable measures of the forces experienced by rat fetuses during parturition. A small (1.25 x 4 cm) telemetric blood pressure sensor was fitted within a fluid-filled balloon, similar in size to a full term rat fetus. On Gestational day (G) 19 of the rats' 22/23 day pregnancy, each dam was anesthetized and a balloon/sensor unit surgically implanted within the uterus following removal of two fetuses. Comparisons were made between sensor-implanted dams (IMPL) and a control conditions: 1) LAP-R, laparotomy with two fetuses removed or 2) LAP-NR, laparotomy with no fetuses removed. IUP signals were sampled at 10s intervals from the IMPL dams during labor and birth. Dams in all three conditions were videorecorded enabling us to analyze the effect of the implant on behavioral expressions of parturition. Contraction frequency, duration, pup-to-pup birth intervals and pup-oriented activities of the dams measured from one hour prior to the first pup birth until the birth of the third pup were unaffected by the sensor implant. Intrauterine telemetry of freely-moving dams offers significant advantages over conventional hardwired IUP measurement techniques. These findings establish and validate intrauterine telemetry as a reliable, non-invasive technique for quantifying pressures associated with parturition.

Villareal, J.↗

A High-Pressure Gas-Scintillation-Proportional Counter for the Focus of a Hard-X-Ray Telescope

We are developing a high-pressure Gas Scintillation Proportional Counter (GSPC) for the focus of a balloon-borne hard-x-ray telescope. The device has a total active diameter of 50 mm, of which the central 20 mm only is used, and is filled with xenon + 4% helium at a total pressure of 10 6 Pa giving a quantum efficiency of greater than 85% up to 60 keV. The detector entrance is sealed with a beryllium window, 3-mm thick, which provides useful transmission down to 6 keV, way below the atmospheric cut-off at balloon float altitudes. Scintillation light exits the detector via a UV transmitting window in its base and is registered by a Hamamatsu position-sensitive crossed-grid-readout photomultiplier tube. Initial testing is underway, quantifying light yield and energy resolution. Following that, the spatial resolution and absolute efficiency will be calibrated. Simulations show that a spatial resolution of better than 0.5 mm FWHM should be achievable up to 60 keV, and this is well matched to the angular resolution and plate scale of the mirror system. The energy resolution will be around 5% at 22 keV. Full details of the instrument design and its performance will be presented. A first flight is scheduled for the Fall of 99, on a stratospheric balloon to be launched from Fort Sumner, New Mexico.

Austin, R. A.↗

Exploring the transition from continuous turbulence fluctuations to bursting ELMs in high SOL density regimes

BOUT++ turbulence simulations of the DIII-D reveal that the density profile between the separatrix and pedestal plays a crucial role in the dynamics of edge localized modes (ELMs) and edge plasma turbulent transport. Nonlinear simulations demonstrate that small ELMs in the DIII-D hybrid scenario under high SOL density conditions are predominantly driven by local ballooning modes near the separatrix, stabilizing global instabilities while enhancing localized pressure fluctuations. A key control parameters for ELM dynamics is the separatrix-to-pedestal density ratio, n e,sep /n e,ped . A high ratio indicates a shallow gradient, favoring small ELMs, while a lower ratio signals a steep gradient, which increases the likelihood of large ELMs. Comprehensive parameter scans, including n e,sep /n e,ped , density gradient profiles near the separatrix, and resistivity, reveal the critical role of these parameters in shaping transitions between turbulence-driven transport and ELM bursting. The scans demonstrate that in high SOL density regimes, small ELMs can result from either global resistive MHD instabilities or local ballooning modes near the separatrix, depending on the steepness of the separatrix density gradient. These findings also highlight the transition from continuous turbulence to small ELMs. The post-crash peak in pressure fluctuations, δP rms serves as a critical metric for identifying transition from continuous turbulence fluctuations to ELM bursting. Larger δP rms values correlate with ELM bursts driven by local or global instabilities, whereas smaller values indicate turbulence-dominated transport. Drift-Alfvén and resistive ballooning turbulence enhance the entrainment of fluctuations from the pedestal to the SOL, contributing to the complex interplay of dynamics in this regime. These findings emphasize the importance of separatrix density shaping and pedestal gradient control for optimizing ELM behavior in ITER and future fusion devices.

Li, Nami [Lawrence Livermore National Laboratory (↗

Retrieval of surface heat and moisture fluxes from slow-launched radiosondes

A feasibility experiment to determine whether the Bowden ratio (and indirectly moisture fluxes and surface heat) can be reasonably and accurately derived from thermodynamic measurements obtained from balloon-launched radiosondes is presented. This experiment was conducted during July 1988 in Tallahassee, Florida using an airsonde system and a surface radiation and energy budget station. The airsonde system consists of a balloon-launched airsonde, which measures vertical profiles of atmospheric pressure, relative humidity, temperature, and an automatic data acquisition system, which receives and records sensor output from the airsonde package. Intercomparisons were made between Bowen ratios derived from the airsonde profiles and the Bowen ratios measured directly by the energy budget station and the surface radiation.

Smith, Eric A.↗

Learn to Fly Test Setup and Concept of Operations

The NASA Learn-to-Fly (L2F) project recently completed a series of flight demonstrations of its learning algorithm for flight control at Fort A. P. Hill in Virginia. This paper discusses the test setup and concept of operations (ConOps) used by the L2F team. Unmanned airframe demonstrators for testing the research algorithms included a modified commercial off-the-shelf subscale powered airplane, plus four gliders – two of which had an unconventional configuration and were fabricated using a “rapid” prototyping technique. Avionics system similarities and differences between the test aircraft are described, as well as ground testing in preparation for flight. The ConOps discussion includes the development of a tethered helium balloon drop launch technique for the glider demonstrators. This launch method was chosen for its potential to be inexpensive and allow for rapid turn-around for multiple glider launches – but it also presented challenges, such as balloon tether avoidance, high angle of attack, low dynamic pressure initial conditions, and susceptibility to winds. A remotely piloted approach employing high-end hobbyist radio controlled (R/C) hardware was used for the powered demonstrator. This approach accommodated the interaction between the R/C flight system and the research flight control computer, engaging the L2F algorithm at varying initial conditions and artificially reducing the aircraft stability to stress the algorithm.

Riddick, Stephen E↗

IMUFDIR Tuning In Response To Structural Deformation Of The Orion Capsule

During system level Thermal Vacuum (TVAC) testing it was discovered that the pressure differential of the crew cabin in a vacuum would deflect the capsule slightly, causing significant misalignment of Orion’s three Inertial Measurement Units (IMUs). This phenomenon has been likened to a balloon expanding. When this misalignment was modeled in simulation as a function of atmospheric pressure, it was determined that the rate of deflection on reentry was significant enough to cause a mis-compare of the angular rates measured by the IMUs. This mis-comparison of the rates caused Orion’s Fault Detection Isolation and Recovery (FDIR) algorithm to falsely fail one of the IMUs. This manuscript will discuss how the IMUFDIR algorithm was detuned to be insensitive to these ballooning effects, while still meeting FDIR requirements to capture real faults in an IMU. All testing to validate this detuning was performed in a Six Degree of Freedom (6 DOF) Monte Carlo Simulation Environment.

Nicholas Rahaim↗

Gamma-ray astronomy using a high pressure gas scintillation drift chamber with a waveshifting fiber readout

We describe a balloon-borne hard X-ray telescope called SIGHT (Scintillation Imaging Gas-filled Hard X-ray Telescope). SIGHT is a high sensitivity, good energy resolution instrument that images in the 30 to 300 keV region. We discuss the development of a large area, 20 atmosphere, position sensitive xenon gas scintillation drift chamber which is the gamma-ray detector at the heart of the telescope package. Results of the development of the novel waveshifting fiber readout for this chamber are presented.

Wilkerson, J.↗

Characterization of the ELM-free negative triangularity edge on DIII-D

Tokamak plasmas with strong negative triangularity (NT) shaping typically exhibit fundamentally different edge behavior than conventional L-mode or H-mode plasmas. On DIII-D, every plasma with sufficiently negative triangularity (δ < δ crit ≃ -0.12) is found to be inherently free of edge localized modes (ELMs), even at injected powers well above the predicted L-H power threshold. It is also possible to access an ELM free state at weaker average triangularities provided that at least one of the two x-points is still sufficiently negative. Access to the ELM-free NT scenario is found to coincide with the closure of the second stability region for infinite-n ballooning modes, suggesting that ballooning stability may play a role in limiting the accessible pressure gradient in NT plasmas. Despite this, NT plasmas are able to support small pedestals and are typically characterized by an enhancement of edge pressure gradients beyond those found in traditional L mode plasmas. Further, the pressure gradient inside of this small pedestal is unusually steep, allowing access to high core performance that is competitive with other ELM-free regimes previously achieved on DIII-D. Since ELM-free operation in NT is linked directly to the magnetic geometry, NT fusion pilot plants are predicted to maintain advantageous edge conditions even in burning plasma regimes, potentially eliminating reactor core-integration issues caused by ELMs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Importance of $\delta B_{\|}$ on ETG stability, turbulence, and transport in NSTX

This study employs electron-scale gyrokinetic simulations to investigate the electron temperature gradient (ETG) driven instabilities, turbulence, and transport in the pedestal region of the National Spherical Torus Experiment, comparing non-lithiated (narrow pedestal) and lithiated (wide pedestal) scenarios. Our findings reveal that, in the non-lithiated case, a branch of strongly unstable ETG modes exhibiting finite parallel magnetic field fluctuations ($\delta B_{\parallel} \neq 0$) emerges at the pedestal top and upper density pedestal region. This branch is uncovered only when $\delta B_{\parallel}$ is retained in the simulations and is associated with substantial electrostatic electron heat flux. This region of strong ETG transport corresponds to the only region in the plasma where the pressure gradient is far below the critical gradient for kinetic ballooning modes. We investigated the origin of this finite $\delta B_{\parallel}$ ETG branch by analyzing the gyrokinetic field equations. Nonlinear saturation is also analyzed and contrasted for simulations with and without $\delta B_{\parallel}$. In contrast with the nonlithiated case, ETG modes in the lithiated case produce substantial transport in the steep gradient region, but are negligible at the pedestal top.

ETG↗

Site G - Atmospheric Sensor / Reviewed Data

This dataset contains meteorological measurements including temperature, pressure, and relative humidity at multiple heights deployed on tethered balloon system at AWAKEN site G. Z07 refers to the seventh height position of the iMet-XQ2 mounted on the tethered balloon.

17 WIND ENERGY↗

Site G - Atmospheric Sensor / Reviewed Data

This dataset contains meteorological measurements including temperature, pressure, and relative humidity at multiple heights deployed on tethered balloon system at AWAKEN site G. Z06 refers to the sixth height position of the iMet-XQ2 mounted on the tethered balloon.

17 WIND ENERGY↗

Site G - Atmospheric Sensor / Reviewed Data

This dataset contains meteorological measurements including temperature, pressure, and relative humidity at multiple heights deployed on tethered balloon system at AWAKEN site G. Z05 refers to the fifth height position of the iMet-XQ2 mounted on the tethered balloon.

17 WIND ENERGY↗

Site G - Atmospheric Sensor / Reviewed Data

This dataset contains meteorological measurements including temperature, pressure, and relative humidity at multiple heights deployed on tethered balloon system at AWAKEN site G. Z04 refers to the fourth height position of the iMet-XQ2 mounted on the tethered balloon.

17 WIND ENERGY↗