Search NASA⌕ Search

SEARCH · Search NASA

Results for “prototype specifications”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Polarimetric performance of a Laue lens gamma-ray CdZnTe focal plane prototype

A gamma-ray telescope mission concept [gamma ray imager (GRI)] based on Laue focusing techniques has been proposed in reply to the European Space Agency call for mission ideas within the framework of the next decade planning (Cosmic Vision 2015-2025). In order to optimize the design of a focal plane for this satellite mission, a CdZnTe detector prototype has been tested at the European Synchrotron Radiation Facility under an {approx}100% polarized gamma-ray beam. The spectroscopic, imaging, and timing performances were studied and in particular its potential as a polarimeter was evaluated. Polarization has been recognized as being a very important observational parameter in high energy astrophysics (>100 keV) and therefore this capability has been specifically included as part of the GRI mission proposal. The prototype detector tested was a 5 mm thick CdZnTe array with an 11x11 active pixel matrix (pixel area of 2.5x2.5 mm{sup 2}). The detector was irradiated by a monochromatic linearly polarized beam with a spot diameter of about 0.5 mm over the energy range between 150 and 750 keV. Polarimetric Q factors of 0.35 and double event relative detection efficiency of 20% were obtained. Further measurements were performed with a copper Laue monochromator crystal placed between the beam and the detector prototype. In this configuration we have demonstrated that a polarized beam does not change its polarization level and direction after undergoing a small angle (<1 deg.) Laue diffraction inside a crystal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Magnetic Head Development Revision 1 Final Report CRADA No. TC-0840-94

The specific go,il of this research was the development of a prototype read magnetic sensor head using the Current:Perpendicular-to-Plane (CPP) geometry with known GMR (Giant Magneto-Resistive) multilayered structures to achieve read densities greater than 10 Gbit/in2, field sensitivities greater than 1%/Oe, switching fields less than 20 Oe, and total MR response greater than 10%. The specific materials needed for this idcnl behavior had to be determined, as did the eventual design of the sensor (placement of contact leads, shields, and biasing magnets). Thus the thrust of the rescnrch required a search for the proper multilayer material combination und the development of a simulation capability to guide sensor design. Issues i:elated to device integration, such as media noise and lead contact resistance, were also recognized as important technological hurdles but these items were deferred until the operating conditions of the-prototype GMR sensor were more precisely determined.

42 ENGINEERING↗

Development of Prototypical District-Scale Models

The U.S. has set the climate goal to achieve net-zero greenhouse gas emissions by 2050. District-scale solutions, which include scale-specific opportunities for energy and emissions savings, can be investigated and implemented to help accelerate decarbonization and progress toward this goal. However, there is currently a lack of district-scale models of buildings and community energy systems that can be used to evaluate potential district-scale technologies and strategies across a range of representative community types. This initial work aims to define and develop prototype district models that can be adapted to support the planning, design, and operation of buildings and energy systems in districts considering the complexity and interactions of diverse building loads, weather impacts, distributed energy resources (e.g., PV, EV, electric and thermal energy storage), electric and thermal grid systems, and pricing signals. An overall workflow for developing these prototype district models is established. Stakeholders and potential users of the prototype district models provided technical feedback. The specifications of the selected high priority districts were defined and documented in a scorecard format. An example prototype district model was implemented with the URBANopt platform workflows. A case study was performed to demonstrate the model application.

building energy modeling↗

Signature of quantum entanglement in NH{sub 4}CuPO{sub 4}·H{sub 2}O

Entangled solid state systems have gained a great deal of attention due to their fruitful applications in modern quantum technologies. Herein, detection of entanglement content from experimental magnetic susceptibility and specific heat data is reported for NH{sub 4}CuPO{sub 4}·H{sub 2}O in its solid state crystalline form. NH{sub 4}CuPO{sub 4}·H{sub 2}O is a prototype of Heisenberg spin 1/2 dimer system. Temperature dependent magnetic susceptibility and specific data are fitted to an isolated dimer model and the exchange coupling constant is determined. Field dependent magnetization isotherms taken at different temperatures are plotted in a three dimensional plot. Subsequently, entanglement is detected both from susceptibility and specific heat through two different entanglement measures; entanglement witness and entanglement of formation. The temperature evolution of entanglement is studied and the critical temperature is determined up to which entanglement exists. Temperature dependent nature of entanglement extracted from susceptibility and specific heat shows good consistency with each other. Moreover, the field dependent entanglement is also investigated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nanocomposite Magnetic Technology for High Frequency MW Scale Power Conversion

The purpose of this project was to demonstrate the use of advanced magnetic materials in a medium voltage DC-DC converter for photovoltaic applications. The lead, alloy development team met project development milestones targeting a low loss material (<20 W/kg at 10kHzT), alloy resistivity (>150μΩcm amorphous phase resistivity), evaluation of the operational lifetime of the material (continuous operation above 155C), and the performance metric (power ratio >100) for a new class of Co-rich alloys with tunable permeability. Material manufacturability was demonstrated in continuously casting over 5 kg batches of 1’’ width, 18μm thickness (less than 80-120% deviation), amorphous ribbon, and processing including field and strain annealing as well as rolling both Fe and Co based alloys to less the 15μm was achieved. Parallel technology to markets efforts found that while a more compact and more efficient converter, which reduces the balance of plant cost, would enjoy a $0.10/W premium over current technology. Due to uncertainty in future energy policy and barriers to market entry the technology to market analyses recommended partnering with an existing manufacturer. The industrial and transportation electric motor market was also identified as one standing to benefit from this material technology and key personnel within this market were identified. With the assistance of Dynapower the converter prototype was tested to 300 VDC (18 kVA) before the resonant capacitors failed. The prototype incorporated several subsystems including the passive and active components at the engineering scale and exposed at least one weak point in the prototype. Independent testing on the core materials predicts that the core would have met the operating specifications, but this component was not tested at nominal power. Based on this prediction and the demonstrated construction of the prototype core, we recommend that the core material is designated TRL 5. The CMU team is currently working with Eaton to identify opportunities further test cores in inductive components.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development and Validation of a Non-Invasive, Chairside Oral Cavity Cancer Risk Assessment Prototype Using Machine Learning Approach

Oral cavity cancer (OCC) is associated with high morbidity and mortality rates when diagnosed at late stages. Early detection of increased risk provides an opportunity for implementing prevention strategies surrounding modifiable risk factors and screening to promote early detection and intervention. Historical evidence identified a gap in the training of primary care providers (PCPs) surrounding the examination of the oral cavity. The absence of clinically applicable analytical tools to identify patients with high-risk OCC phenotypes at point-of-care (POC) causes missed opportunities for implementing patient-specific interventional strategies. This study developed an OCC risk assessment tool prototype by applying machine learning (ML) approaches to a rich retrospectively collected data set abstracted from a clinical enterprise data warehouse. We compared the performance of six ML classifiers by applying the 10-fold cross-validation approach. Accuracy, recall, precision, specificity, area under the receiver operating characteristic curve, and recall–precision curves for the derived voting algorithm were: 78%, 64%, 88%, 92%, 0.83, and 0.81, respectively. The performance of two classifiers, multilayer perceptron and AdaBoost, closely mirrored the voting algorithm. Integration of the OCC risk assessment tool developed by clinical informatics application into an electronic health record as a clinical decision support tool can assist PCPs in targeting at-risk patients for personalized interventional care.

60 APPLIED LIFE SCIENCES↗

Development of Prototypical District-Scale Models: Preprint

The U.S. has set the climate goal to achieve net-zero greenhouse gas emissions by 2050. District-scale solutions, which include scale-specific opportunities for energy and emissions savings, can be investigated and implemented to help accelerate decarbonization and progress toward this goal. However, there is currently a lack of district-scale models of buildings and community energy systems that can be used to evaluate potential district-scale technologies and strategies across a range of representative community types. This initial work aims to define and develop prototype district models that can be adapted to support the planning, design, and operation of buildings and energy systems in districts considering the complexity and interactions of diverse building loads, weather impacts, distributed energy resources (e.g., PV, EV, electric and thermal energy storage), electric and thermal grid systems, and pricing signals. An overall workflow for developing these prototype district models is established. Stakeholders and potential users of the prototype district models provided technical feedback. The specifications of the selected high priority districts were defined and documented in a scorecard format. An example prototype district model was implemented with the URBANoptTM platform workflows. A case study was performed to demonstrate the model application.

district↗

Development of strong-sense validation benchmarks for the fluoride salt-cooled high-temperature reactor

The Fluoride salt-cooled High-temperature Reactor (FHR) is a class of reactor concepts currently under development for the U. S. Dept. of Energy. The FHR is defined as a Generation IV reactor that features low-pressure liquid fluoride salt cooling, coated-particle fuel, a high-temperature power cycle, and fully passive decay heat rejection. Recent experimental work using simulant fluids have been performed to demonstrate key 'proof of principle' FHR concepts and have helped inform the reactor design process. An important element of developing FHR technology is to sufficiently validate the predictive accuracy of the computer codes used to model system response. This paper presents a set of thermal-hydraulics experiments, defined as Strong-Sense Benchmarks (SSB's), which will help establish the FHR validation domain for simulant fluid suitability. These SSB's are more specifically designed to investigate single-phase natural circulation which is the dominant mode of FHR decay heat removal during off-normal conditions. SSB s should be viewed as engineering reference standards and differ from traditional confirmatory experiments in the sense that they are more focused on fundamental physics as opposed to reproducing high levels of physical similarity with the prototypical design. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Site-specific probing of charge transfer dynamics in organic photovoltaics

We report the site-specific probing of charge-transfer dynamics in a prototype system for organic photovoltaics (OPVs) by picosecond time-resolved X-ray photoelectron spectroscopy. A layered system consisting of approximately two monolayers of C{sub 60} deposited on top of a thin film of Copper-Phthalocyanine (CuPC) is excited by an optical pump pulse and the induced electronic dynamics are probed with 590 eV X-ray pulses. Charge transfer from the electron donor (CuPC) to the acceptor (C{sub 60}) and subsequent charge carrier dynamics are monitored by recording the time-dependent C 1s core level photoemission spectrum of the system. The arrival of electrons in the C{sub 60} layer is readily observed as a completely reversible, transient shift of the C{sub 60} associated C 1s core level, while the C 1s level of the CuPC remains unchanged. The capability to probe charge transfer and recombination dynamics in OPV assemblies directly in the time domain and from the perspective of well-defined domains is expected to open additional pathways to better understand and optimize the performance of this emerging technology.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

N-terminal additions to the WE14 peptide of chromogranin A create strong autoantigen agonists in type 1 diabetes

Chromogranin A (ChgA) is an autoantigen for CD4 + T cells in the nonobese diabetic (NOD) mouse model of type 1 diabetes (T1D). The natural ChgA-processed peptide, WE14, is a weak agonist for the prototypical T cell, BDC-2.5, and other ChgA-specific T-cell clones. Mimotope peptides with much higher activity share a C-terminal motif, WXRM(D/E), that is predicted to lie in the p5 to p9 position in the mouse MHC class II, IA g7 binding groove. This motif is also present in WE14 (WSRMD), but at its N terminus. Therefore, to place the WE14 motif into the same position as seen in the mimotopes, we added the amino acids RLGL to its N terminus. Like the other mimotopes, RLGL-WE14, is much more potent than WE14 in T-cell stimulation and activates a diverse population of CD4 + T cells, which also respond to WE14 as well as islets from WT, but not ChgA –/– mice. The crystal structure of the IA g7 –RLGL–WE14 complex confirmed the predicted placement of the peptide within the IA g7 groove. Fluorescent IA g7 –RLGL–WE14 tetramers bind to ChgA-specific T-cell clones and easily detect ChgA-specific T cells in the pancreas and pancreatic lymph nodes of NOD mice. Here, the prediction that many different N-terminal amino acid extensions to the WXRM(D/E) motif are sufficient to greatly improve T-cell stimulation leads us to propose that such a posttranslational modification may occur uniquely in the pancreas or pancreatic lymph nodes, perhaps via the mechanism of transpeptidation. This modification could account for the escape of these T cells from thymic negative selection.

59 BASIC BIOLOGICAL SCIENCES↗

Multiscale deformable registration for dual-energy x-ray imaging

Dual-energy (DE) imaging of the chest improves the conspicuity of subtle lung nodules through the removal of overlying anatomical noise. Recent work has shown double-shot DE imaging (i.e., successive acquisition of low- and high-energy projections) to provide detective quantum efficiency, spectral separation (and therefore contrast), and radiation dose superior to single-shot DE imaging configurations (e.g., with a CR cassette). However, the temporal separation between high-energy (HE) and low-energy (LE) image acquisition can result in motion artifacts in the DE images, reducing image quality and diminishing diagnostic performance. This has motivated the development of a deformable registration technique that aligns the HE image onto the LE image before DE decomposition. The algorithm reported here operates in multiple passes at progressively smaller scales and increasing resolution. The first pass addresses large-scale motion by means of mutual information optimization, while successive passes (2-4) correct misregistration at finer scales by means of normalized cross correlation. Evaluation of registration performance in 129 patients imaged using an experimental DE imaging prototype demonstrated a statistically significant improvement in image alignment. Specific to the cardiac region, the registration algorithm was found to outperform a simple cardiac-gating system designed to trigger both HE and LE exposures during diastole. Modulation transfer function (MTF) analysis reveals additional advantages in DE image quality in terms of noise reduction and edge enhancement. This algorithm could offer an important tool in enhancing DE image quality and potentially improving diagnostic performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Backend-agnostic, Quantum-classical Framework for Simulations of Chemistry in C ++

As quantum computing hardware systems continue to advance, the research and development of performant, scalable, and extensible software architectures, languages, models, and compilers is equally as important to bring this novel coprocessing capability to a diverse group of domain computational scientists. For the field of quantum chemistry, applications and frameworks exist for modeling and simulation tasks that scale on heterogeneous classical architectures, and we envision the need for similar frameworks on heterogeneous quantum-classical platforms. Furthermore, we present the XACC system-level quantum computing framework as a platform for prototyping, developing, and deploying quantum-classical software that specifically targets chemistry applications. We review the fundamental design features in XACC, with special attention to its extensibility and modularity for key quantum programming workflow interfaces and provide an overview of the interfaces most relevant to simulations of chemistry. A series of examples demonstrating some of the state-of-the-art chemistry algorithms currently implemented in XACC are presented, while also illustrating the various APIs that would enable the community to extend, modify, and devise new algorithms and applications in the realm of chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparative genomics, infectivity and cytopathogenicity of Zika viruses produced by acutely and persistently infected human hematopoietic cell lines

Zika virus (ZIKV), an arthropod-borne virus, has emerged as a major human pathogen. Prolonged or persistent ZIKV infection of human cells and tissues may serve as a reservoir for the virus and present serious challenges to the safety of public health. Human hematopoietic cell lines with different developmental properties revealed differences in susceptibility and outcomes to ZIKV infection. In three separate studies involving the prototypic MR 766 ZIKV strain and the human monocytic leukemia U937 cell line, ZIKV initially developed only a low-grade infection at a slow rate. After continuous culture for several months, persistently ZIKV-infected cell lines were observed with most, if not all, cells testing positive for ZIKV antigen. The infected cultures produced ZIKV RNA (v-RNA) and infectious ZIKVs persistently (“persistent ZIKVs”) with distinct infectivity and pathogenicity when tested using various kinds of host cells. When the genomes of ZIKVs from the three persistently infected cell lines were compared with the genome of the prototypic MR 766 ZIKV strain, distinct sets of mutations specific to each cell line were found. Significantly, all three “persistent ZIKVs” were capable of infecting fresh U937 cells with high efficiency at rapid rates, resulting in the development of a new set of persistently ZIKV-infected U937 cell lines. The genomes of ZIKVs from the new set of persistently ZIKV-infected U937 cell lines were further analyzed for their different mutations. The 2nd generation of persistent ZIKVs continued to possess most of the distinct sets of mutations specific to the respective 1st generation of persistent ZIKVs. We anticipate that the study will contribute to the understanding of the fundamental biology of adaptive mutations and selection during viral persistence. The persistently ZIKVinfected human cell lines that we developed will also be useful to investigate critical molecular pathways of ZIKV persistence and to study drugs or countermeasures against ZIKV infections and transmission.

59 BASIC BIOLOGICAL SCIENCES↗

Solar Decarbonization of Paraffin Dehydrogenation Through Particle Heat Carriers (Final Technical Report)

This project focuses on solutions to decarbonize high-temperature catalytic processes using solar thermal heat. The primary project goal is to show the validity of a moving packed bed reactor for propane dehydrogenation using catalyst particles as the heat carrier for the reaction, which can be heated by concentrated solar energy in a particle receiver. This concept, if further developed, may provide a cost-effective pathway for converting lower value gases to important chemical precursors for industrial materials using only renewable energy. The project was divided into six tasks. In Task 1, DFT calculations were performed to understand the role of Pt and Sn in the catalytic dehydrogenation reaction. In Task 2 chemical kinetics measurements were made for several catalyst formulations at high temperatures. In Task 3, the solar absorptance of catalyst particles was compared to the absorptance of commonly used materials in particle receivers. In Task 4, numerical models were developed which could predict performance of the complete system and predict specific temperatures in the system. In Task 5, a prototype system was designed, fabricated, and tested to show the validity of the concept. Task 6 concerned project management activities. Experiments with the prototype showed repeatable thermal performance at temperatures targeted for the reaction. A limited set of tests were done with active catalyst and propane dehydrogenation, showing conversion of propane to propylene with a range of conversions and selectivities. The results are promising, and the prototype designed was reliable during testing, and the team expects that further development of the prototype would yield improved results. A numerical model framework based on coupled fluid and particle mechanics was developed with high computational efficiency using GPU calculations. The model may prove highly useful for evaluating other high-temperature particle systems. However, it was determined that simpler porous media models were good fits for the needs of the current moving packed bed concept. Data showing strong solar absorption of the particles validates the plan of using existing solar particle receivers with only a change in the particle type. Catalyst investigation showed that Pt 1 Sn 3 is the most viable candidate for developing PtSn catalysts for high temperature propane dehydrogenation, considering the balance of activity, selectivity, and deactivation. This project completed an initial study of various factors needed to incorporate a moving bed catalytic reactor for propane dehydrogenation into a concentrated solar thermal particle system. Future developments may allow this technology to be scaled up and help to use solar thermal energy to decarbonize not only the propane dehydrogenation reaction, but other gas-solid catalytic reactions at similar temperatures.

14 SOLAR ENERGY↗

Mechanical Analysis of the 400 MHz RF-Dipole Crabbing Cavity Prototype for LHC High Luminosity Upgrade

The proposed LHC high luminosity upgrade requires two crabbing systems in increasing the peak luminosity, operating both vertically and horizontally at two interaction points of IP1 and IP5. The required system has tight dimensional constraints and needs to achieve higher operational gradients. A proof-of-principle 400 MHz crabbing cavity design has been successfully tested and has proven to be an ideal candidate for the crabbing system. The cylindrical proof-of-principle rf-dipole design has been adapted in to a square shaped design to further meet the dimensional requirements. The new rf-dipole design has been optimized in meeting the requirements in rf-properties, higher order mode damping, and multipole components. A crabbing system in a cryomodule is expected to be tested on the SPS beam line prior to the test at LHC. The new prototype is required to achieve the mechanical and thermal specifications of the SPS test followed by the test at LHC. This paper discusses the detailed mechanical and thermal analysis in minimizing Lorentz force detuning and sensitivity to liquid He pressure fluctuations.

43 PARTICLE ACCELERATORS↗

Higher Efficiency HVAC Motors

The objective of this project was to design and build a cost competitive, more efficient heating, ventilation, and air conditioning (HVAC) motor than what is currently available on the market. Though different potential motor architectures among QMP’s primary technology platforms were investigated and evaluated, including through the building of numerous prototypes, the project ultimately focused on scaling up QM Power, Inc.’s (QMP) Q-Sync permanent magnet synchronous motors from available sub-fractional horsepower (HP) sizes for commercial refrigeration fan applications to larger fractional horsepower sizes appropriate for HVAC applications, and to add multi-speed functionality. The more specific goal became the research, design, development, and testing of a prototype 1/2 HP Q-Sync motor that has at least two operating speeds and 87% peak efficiency compared to incumbent electronically commutated motors (EC or ECM, also known as brushless direct current (DC) motors), the heretofore highest efficiency HVACR fan motor solution, at approximately 82% peak efficiency. The resulting motor prototype built achieved these goals, hitting 90% efficiency and .95 power factor at full load and speed, and 80% efficiency and .7 power factor at half speed. Q-Sync, developed in part through a DOE SBIR grant (Award # DE-SC0006311), is a novel, patented motor technology that improves on electronically commutated permanent magnet motors through an advanced electronic circuit technology. It allows a motor to “sync” with the alternating current (AC) power flow. It does so by eliminating the constant, wasteful power conversions from AC to DC and back to AC through the synthetic creation of a new AC wave on the primary circuit board (PCB) by a process called pulse width modulation (PWM; aka electronic commutation) that is incessantly required to sustain motor operation in an EC permanent magnet motor. The Q-Sync circuit improves the power factor of the motor by removing all failure prone capacitors from the power stage. Q-Sync’s simpler electronics also result in higher efficiency because it eliminates the power required by the PCB to perform the obviated power conversions and PWM processes after line synchronous operating speed is reached in the first 5 seconds of operation, after which the PWM circuits drop out and a much less energy intensive “pass through” circuit takes over, allowing the grid-supplied AC power to sustain the motor’s ongoing operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A dedicated cone-beam CT system for musculoskeletal extremities imaging: Design, optimization, and initial performance characterization

Purpose: This paper reports on the design and initial imaging performance of a dedicated cone-beam CT (CBCT) system for musculoskeletal (MSK) extremities. The system complements conventional CT and MR and offers a variety of potential clinical and logistical advantages that are likely to be of benefit to diagnosis, treatment planning, and assessment of therapy response in MSK radiology, orthopaedic surgery, and rheumatology. Methods: The scanner design incorporated a host of clinical requirements (e.g., ability to scan the weight-bearing knee in a natural stance) and was guided by theoretical and experimental analysis of image quality and dose. Such criteria identified the following basic scanner components and system configuration: a flat-panel detector (FPD, Varian 3030+, 0.194 mm pixels); and a low-power, fixed anode x-ray source with 0.5 mm focal spot (SourceRay XRS-125-7K-P, 0.875 kW) mounted on a retractable C-arm allowing for two scanning orientations with the capability for side entry, viz. a standing configuration for imaging of weight-bearing lower extremities and a sitting configuration for imaging of tensioned upper extremity and unloaded lower extremity. Theoretical modeling employed cascaded systems analysis of modulation transfer function (MTF) and detective quantum efficiency (DQE) computed as a function of system geometry, kVp and filtration, dose, source power, etc. Physical experimentation utilized an imaging bench simulating the scanner geometry for verification of theoretical results and investigation of other factors, such as antiscatter grid selection and 3D image quality in phantom and cadaver, including qualitative comparison to conventional CT. Results: Theoretical modeling and benchtop experimentation confirmed the basic suitability of the FPD and x-ray source mentioned above. Clinical requirements combined with analysis of MTF and DQE yielded the following system geometry: a {approx}55 cm source-to-detector distance; 1.3 magnification; a 20 cm diameter bore (20 x 20 x 20 cm{sup 3} field of view); total acquisition arc of {approx}240 deg. The system MTF declines to 50% at {approx}1.3 mm{sup -1} and to 10% at {approx}2.7 mm{sup -1}, consistent with sub-millimeter spatial resolution. Analysis of DQE suggested a nominal technique of 90 kVp (+0.3 mm Cu added filtration) to provide high imaging performance from {approx}500 projections at less than {approx}0.5 kW power, implying {approx}6.4 mGy (0.064 mSv) for low-dose protocols and {approx}15 mGy (0.15 mSv) for high-quality protocols. The experimental studies show improved image uniformity and contrast-to-noise ratio (without increase in dose) through incorporation of a custom 10:1 GR antiscatter grid. Cadaver images demonstrate exquisite bone detail, visualization of articular morphology, and soft-tissue visibility comparable to diagnostic CT (10-20 HU contrast resolution). Conclusions: The results indicate that the proposed system will deliver volumetric images of the extremities with soft-tissue contrast resolution comparable to diagnostic CT and improved spatial resolution at potentially reduced dose. Cascaded systems analysis provided a useful basis for system design and optimization without costly repeated experimentation. A combined process of design specification, image quality analysis, clinical feedback, and revision yielded a prototype that is now awaiting clinical pilot studies. Potential advantages of the proposed system include reduced space and cost, imaging of load-bearing extremities, and combined volumetric imaging with real-time fluoroscopy and digital radiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Control of the UV flux of a XeCl dielectric barrier discharge excilamp through its current variation

The efficiency of the electrical power transfer to the gas mixture of a XeCl dielectric barrier discharge (DBD) exciplex lamp is analysed. An equivalent circuit model of the DBD is considered. It is shown that the excilamp power can be controlled by applying current to the lamp. This highly desired property is ensured by means of a specific power supply topology, whose concepts and design are discussed. The experimental prototype of a current-mode converter operating in the pulsed regime at pulse repetition rate of 50 kHz is presented and its capability to control the amount of energy transferred during each current pulse is demonstrated. The capability of this power supply to maintain specific operating conditions for the DBD lamp, with a very stable behaviour (even at a very low current, in the regime of a single discharge channel), is illustrated. The experimental results of a combined use of this converter and a XeCl excilamp are presented. The influence of the supply parameters on the 308-nm XeCl excilamp is analysed. The shape of the UV pulse of the lamp is experimentally shown to be similar to that of the current, which actually flows into the gas mixture. The UV radiation power is demonstrated to be tightly correlated to the current injected into the gas and controlled by the available degrees of freedom offered by the power supply. The measured UV output characteristics and performance of the system are discussed. Time resolved UV imaging of a XeCl DBD excilamp is used to analyse the mechanisms involved in the production of exciplexes at various power supply regimes. It is shown that a pulsed voltage source leads to formation of short high intensity UV peaks, while current pulses lead to formation of sustained discharge filaments. Based on the results of modelling of the above-mentioned operation conditions, the two power supply regimes are compared and analysed from the point of view of the UV power and radiative control.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗