Search NASA⌕ Search

SEARCH · Search NASA

Results for “prototyping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

U.S. Department of Energy Competitiveness Improvement Project (CIP) 2025 Prototype Manufacture Awardee: XFlow Energy

Vertical-axis wind turbines offer a compelling path to low-cost, reliable distributed energy that can compete with utility prices for businesses, landowners, and municipalities in rural areas. They generate power by using a main rotor shaft perpendicular to the ground to pick up wind from different directions without a yaw mechanism. However, previous commercialization attempts struggled to account for the unsteady aerodynamics of this design, leading to low power production and/or premature structural failure. To address these challenges, Competitiveness Improvement Project recipient XFlow Energy is building on work completed during three previous CIP funding awards to develop a 30-kW vertical-axis wind turbine that achieves both low costs and high energy output.

17 WIND ENERGY↗

Demonstration Trials of AI/ML Edge+Cloud Suite (CRADA Final Report)

PACE AI and LBNL partnered under this CRADA to test and evaluate the PACE5 edge node prototype, an AI/ML edge and cloud-based suite, at FLEXLAB.The objective of the test was to evaluate the PACE5 edge node prototype's ability to perform demand shed and take to dynamic price signals, and to demonstrate advanced fault detection and microgrid monitoring capabilities.

97 MATHEMATICS AND COMPUTING↗

Exploring the Use of Flexible Circuit Boards to the Increase Power Density of a Rotary Triboelectric Nanogenerator

EExpansion on previous triboelectric nanogenerator (TENG) research that investigated a freestanding rotary TENG. The previous prototype used a single printed circuit board (PCB) stator with exposed copper electrodes and an arcylic rotor with vinyl-cut fluorinated ethylene propylene (FEP) wedges. The second generation prototype again used a PCB stator but used a flexible PCB rotor consisting of alternating polyamide and copper wedges. This prototype was assembled in a stacked configuration, with the intent of increasing current output. Results indicated that the internal resistance of the prototype was decreased, allowing for higher current output. However, degradation of the power output was observed, which led to decay testing of the prototypes. To overcome charge decay, a self-exciting design is suggested as further work.

42 ENGINEERING↗

Development of a Robust Reference Electrode in Aggressive Chemical and Radiation Environments in the Hanford Waste Tanks

The Hanford site stores more than 200 million liters of radioactive and chemically hazardous wastes from the production of weapons materials. The wastes are stored in 177 underground carbon-steel storage tanks, separated between 149 single shell tanks (SSTs) and 28 double shell tanks (DSTs). The DSTs provide critical retrieval and interim storage before the waste is vitrified in the Waste Treatment and Isolation Plant (WTP). The tanks will need to remain in-service far beyond the initial 40-year design life, and effective corrosion control practices must remain in force to extend the tanks’ lifespans. This effort includes direct measurements of corrosion rate (e.g., ultrasonic measurements and corrosion coupons) and electrochemical processes (e.g., linear polarization measurements and open circuit potential measurements). The Hanford site began monitoring the corrosion potential in select DSTs in 2008. Of the 45 reference electrodes that have been installed, 29 have failed and 6 others provided unreliable results. DOE-EM is supporting a 3-year program to develop a chemical and radiation resistant reference electrode for application in the Hanford tanks. The first year of the program focused on understanding the failure mechanism for the reference electrodes and identification of candidate construction materials that would mitigate degradation of the electrodes in the waste environment. During the second year of the program, the objectives were to: 1) test candidate materials under simulated waste conditions, 2) design components that will extend the service life of the electrode, 3) fabricate materials for prototype reference electrodes, and 4) assemble prototype reference electrodes for accelerated testing. The reference electrode is constructed of four principal parts: 1) junction, 2) casing, 3) inner chamber backfill materials, and 4) the sensing wire. Principally, improvements of the junction, casing, and inner chamber backfill materials are being pursued. The junction material at the interface between the waste and the inner chamber of the reference electrode was identified as a critical component in the failure of the reference electrodes. Nine candidate replacement junction materials were tested under simulated waste conditions to evaluate permeation rate. These materials included a variety of polymeric and ceramic materials, some of which were 3-D printed. Thus far, porous polyvinylidene fluoride materials have performed satisfactorily and are being considered for prototype development. The commercial electrode casing materials in general have performed well. Additionally, 3-D printing of chemically and mechanically stable materials is being investigated as a means for further improvement in fabrication consistency. SRNL has also investigated altering the reference electrode design to extend the service life. The new design of the interior of the reference electrode casing creates a longer, more tortuous path between the junction material and the electrode sensing wire. A finite element model was used to optimize the design without adversely impacting the circuit resistance of the electrode during the measurements, thus preserving the measurement accuracy while enhancing the service life. The inner chamber back fill materials are also critical to the performance of the reference electrode. Materials that are resistant to intruding tank waste and provide a conductive path to the sensing wire were investigated. Gel and powder materials that are interspersed with a conductive chloride bearing material were tested for their influence on diffusion and electrode resistance. All the investigated materials and components will be assembled, with collaboration from commercial vendors, to fabricate the initial prototypes. Accelerated testing of the prototypes will be initiated in Year 2 of the program and will be completed in Year 3. A recommendation on the materials of construction and the design of the new robust reference electrode will be presented to the Hanford tank farm facility.

Sykes, Kiana [Savannah River National Laboratory (↗

Development of a micro-combined heat and power powered by an opposed-piston engine in building applications

Residential homes and light commercial buildings usually require substantial heat and electricity simultaneously. A combined heat and power system enables more efficient and environmentally friendly energy usage than that achieved when heat and electricity are produced in separate processes. However, due to financial and space constraints, residential and light commercial buildings often limit the use of traditional large-scale industrial equipment. Here we develop a micro–combined heat and power system powered by an opposed-piston engine to simultaneously generate electricity and provide heat to residential homes or light commercial buildings. The developed prototype attains the maximum AC electrical efficiency of 35.2%. The electrical efficiency breaks the typical upper boundary of 30% for micro–combined heat and power systems using small internal combustion engines (i.e., <10 kW). Moreover, the developed prototype enables maximum combined electrical and thermal efficiencies greater than 93%. The prototype is optimally designed for natural gas but can also run renewable biogas and hydrogen, supporting the transition from current conventional fossil fuels to zero carbon emissions in the future. The analysis of the unit’s decarbonization and cost-saving potential indicate that, except for specific locations, the developed prototype might excel in achieving decarbonization and cost savings primarily in US northern and middle climate zones.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A compact low-level RF control system for advanced concept compact electron linear accelerator

A compact low-level RF (LLRF) control system based on RF system-on-chip (RFSoC) technology has been designed for the Advanced Concept Compact Electron Linear-accelerator (ACCEL) program, which has challenging requirements in both RF performance and size, weight, and power consumption (SWaP). The compact LLRF solution employs the direct RF sampling technique of RFSoC, which samples the RF signals directly without any analog upconversion and downconversion. Compared with the conventional heterodyne based architecture used for the LLRF system of a linear accelerator (LINAC), the elimination of analog mixers can significantly reduce the size and weight of the system, especially with LINAC requiring a larger number of RF channels. Based on the requirements of ACCEL, a prototype LLRF platform has been developed, and the control schemes have been proposed. The prototype LLRF system demonstrated magnitude and phase fluctuation levels below 1% and 1° on the flattop of a 2 μs RF pulse. The LLRF control schemes proposed for ACCEL are implemented with a prototype hardware platform. In conclusion, this paper will introduce the new compact LLRF solution and summarize a selection of experimental test results of the prototype itself and with the accelerating structure cavities designed for ACCEL.

Liu, C. [SLAC National Accelerator Laboratory (SLA↗

Strategic styles of hardware product development could accelerate commercialization in cleantech startups

Hardware-based startups risk having longer times-to-market, deterring investment in the clean technologies that are critical to a sustainable future. We interviewed 55 leaders at hardware startups, 20 of which are cleantech, mapped their development timelines, and found prototyping to be the longest development step (median of 19 weeks per prototype) regardless of prototype complexity or iteration. Qualitative interview analysis reveals the prototyping team’s choice of development style is a major factor affecting timeline. We define two development styles: natural and structured, typified by free-form exploration and rule-based execution, respectively. On average, natural development takes 35% less time than structured, and is thus preferred for early iterations, but adopting structure at strategic points is needed for timely commercialization. Critical points of transition to a structured style include adding new team members or engaging external partners, which demand clear communication and expectations. When pivoting to a new product or market, returning to a natural style is beneficial.

Looney, Erin (ORCID:0000000168959312)↗

High-Efficiency Thermoelectric Clothes Dryer (CRADA Final Report)

A typical clothes dryer in the US accounts for 7% of the average residential customer’s electric bill. Nationwide, consumers pay about $\$$9 billion annually for clothes drying. While energy efficiency for most household appliances has improved by a factor of 2 or more in recent decades, today’s clothes dryers perform similarly to units from the 1970s. Dryer efficiency is measured by the combined energy factor (CEF), with today’s units typically drying 3.73 lb of cloth per kWh consumed. An ENERGY STAR qualified unit must achieve 3.93 lb/kWh (for standard size electric units) and dry in less than 80 minutes. ORNL and CRADA partner Samsung Electronics America have developed an efficient prototype clothes dryer that uses thermoelectric heat pumps instead of electric resistance to dry the clothes. The prototype fabricated at ORNL successfully demonstrated in the laboratory a CEF of 6.89 lb/kWh at standard conditions of 75°F and 50% Relative Humidity (RH), exceeding the original project target of 6.0 lb/kWh. Additional trials on the same prototype achieved faster dry time with slightly lower CEF, meeting all requirements for ENERGY STAR product qualification. Deploying dryers with energy factor of 6 nationwide represents a technical potential of 234 TBtu/yr primary energy savings. The modeling and prototype development activities for the thermoelectric clothes dryer under this CRADA are summarized in this final report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fast timing with µRWELL-PICOSEC detector technology

The µWELL-PICOSEC detector, which is based on Resistive Micro-Well (µRWELL) technology, is a novel concept for fast timing gaseous detectors that can provide timing resolution in the tens of picosecond range, making it ideal candidate for time-of-flight (TOF) technology for particle identification (PID) in particle physics experiments as well as for future medical instrumentation. The µRWELL-PICOSEC concept is based on a Cerenkov radiator that produces Cerenkov photons from high energetic charged particles, a photocathode layer that converts the Cerenkov photons into primary electrons, a µRWELL amplification layer that multiply the electrons through amplification in a CF4-based gas mixture and a pad-segmentation anode readout coupled with fast timing electronics to provide fast signal. Beam tests were carried out at the CERN SPS H4 beamline in summer 2023 and 2024. Preliminary results show timing performance of the order of 23 ps achievable with µRWELL-PICOSEC prototype. and position scan of the 100-pads of a multi-channel prototype was also performed to study time response uniformity of large area detector. In this talk, after a brief overview of the PICOSEC technology, we will present recent results with different single channel µRWELL-PICOSEC prototype designs and also the position scan results of the 100-pads large prototype to study timing response uniformity for large area µRWELL-PICOSEC detector. Finally, we will discuss the ongoing R&D effort to further improve the timing resolution and allow good position capabilities through charge sharing for large area.

Gnanvo, Kondo↗

T-Type Modular DC Circuit Breaker (T-Breaker) for Future DC Networks

The developed T-Type Modular DC Circuit Breaker (T-Breaker) technology offers an all-in-one solution to challenges in DC networks. This includes swift fault detection and protection, power transient stability, and power quality improvement, achieved through the utilization of wide bandgap (WBG) power semiconductors and energy storage devices. The T-Breaker not only facilitates rapid fault current detection and interruption but also implements fault current limiting through active insertion of storage devices or by operating WBG devices in the saturation region. Additionally, with the assistance of energy storage devices, potential overvoltage issues on power devices induced by control signal misalignment can be mitigated. The T-Breaker can be regulated to perform shunt current injection/absorption using the vertical arm and series voltage insertion via the horizontal arm, thereby enhancing DC system stability during voltage or load power fluctuation transients. The OSU team and Raytheon team actively worked together on designing, fabricating, assembling, and testing of two T-Breaker prototypes. The first prototype is rated at 1 kV, 500 A with half-bridge (unipolar) structure to validate the T-Breaker concept. The second prototype is rated at 20 kV, 50 A with full-bridge (bipolar) topology which can reach an efficiency of 99.977%, realize a power density of 60.2 MW/m3, and eliminate the 500-A fault current with a fault response time of around 20 µs. The prototypes show great feasibility of adopting this technology in multiple applications including electrified aircraft, super charging stations, data centers, etc.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real time heat load calculation software based on EPICS for Fermilab PIP-II CM tests

Fermilab has a project to improve the proton beam energy which is called PIP-II (the 2nd Proton Improvement Plan). There is a superconducting linear accelerator, LINAC, to improve the proton beam power and the LINAC consists of 5 types of cryomodules (CM), 1 HWR CM, 2 SSR1 CM, 4 SSR2 CM, LB650 CM, and HB650 CM. The prototypes of these cryomodules are being tested at Fermilab’s CryoModule Test Facility (CMTF). Heat load measurements are an important part of the prototype CM testing. The CMTF cryogenic control system was developed based on the ACNET (Accelerator Control NETwork) for CM testing for other projects, but the PIP-II cryogenic control system will be implemented using the Experimental Physics and Industrial Control System (EPICS). As part of the prototype CM testing campaign an EPICS based control system has been implemented at CMTF. This EPICS cryogenic control system includes real time heat load calculation software utilizing the Fortran implementation of Hepak. This paper details the real time heat load calculation software developed for the prototype CM testing including the first results from the HB 650 CM.

Yoon, S. [Fermilab]↗

Exploring the Nature of Neutrinos with the Deep Underground Neutrino Experiment (DUNE)

The Deep Underground Neutrino Experiment (DUNE) is a next-generation experimental program designed to study the behaviour of neutrino oscillation. DUNE will utilize a neutrino beam originating at Fermilab, near Chicago, and will leverage a detector at Fermilab (Near Detector) and a detector 1300 km away in South Dakota (Far Detector), south of Saskatchewan. In the first phase of DUNE, its Far Detector will comprise of two 10,000 ton (fiducial) liquid argon (LAr) time-projection chamber (TPC) modules – powerful tracking calorimeter detectors – placed nearly a mile underground. With this large, sensitive, underground detector, DUNE aims to collect a high statistics and pure sample of neutrinos at the Far Detector. This setup also offers the potential to study non-beam physical processes via e.g. neutrinos produced in the atmosphere, supernova neutrino bursts, and/or solar neutrinos, etc. A second phase will aim to add more detector mass and expand the program. The Near Detector will consist of a LAr TPC module as well: critical to constraining systematic uncertainties in the oscillation analysis. However, this LAr TPC will have a novel design using a pixel-based readout instead of the traditional wire-based readout. This and the segmentation of the LAr TPC into multiple units are crucial in mitigating the high multiplicity of neutrino interactions expected in any readout window given its proximity to the beam. The Near Detector will feature additional components and capability beyond the LAr TPC, allowing one to deeply characterize the neutrino flux. Due to the complexity of this experimental program, several smaller-scale prototype detectors have been operating to test, validate, and improve both the technical designs and software for processing and analyzing events. By operating in charged particle test beams or neutrino beams, several of the prototypes are also capable of producing valuable results. Canadian institutions are involved in the realization of the DUNE through efforts with both the Near and Far Detectors and prototypes. DUNE is anticipated to begin operating near the end of this decade/the beginning of the next. This talk will focus on the overall DUNE program, for example its ultimate plans, status, and the efforts with prototypes.

Howard, Bruce [York U., Canada; Fermilab]↗

Solar Decarbonization of Paraffin Dehydrogenation Through Particle Heat Carriers (Final Technical Report)

This project focuses on solutions to decarbonize high-temperature catalytic processes using solar thermal heat. The primary project goal is to show the validity of a moving packed bed reactor for propane dehydrogenation using catalyst particles as the heat carrier for the reaction, which can be heated by concentrated solar energy in a particle receiver. This concept, if further developed, may provide a cost-effective pathway for converting lower value gases to important chemical precursors for industrial materials using only renewable energy. The project was divided into six tasks. In Task 1, DFT calculations were performed to understand the role of Pt and Sn in the catalytic dehydrogenation reaction. In Task 2 chemical kinetics measurements were made for several catalyst formulations at high temperatures. In Task 3, the solar absorptance of catalyst particles was compared to the absorptance of commonly used materials in particle receivers. In Task 4, numerical models were developed which could predict performance of the complete system and predict specific temperatures in the system. In Task 5, a prototype system was designed, fabricated, and tested to show the validity of the concept. Task 6 concerned project management activities. Experiments with the prototype showed repeatable thermal performance at temperatures targeted for the reaction. A limited set of tests were done with active catalyst and propane dehydrogenation, showing conversion of propane to propylene with a range of conversions and selectivities. The results are promising, and the prototype designed was reliable during testing, and the team expects that further development of the prototype would yield improved results. A numerical model framework based on coupled fluid and particle mechanics was developed with high computational efficiency using GPU calculations. The model may prove highly useful for evaluating other high-temperature particle systems. However, it was determined that simpler porous media models were good fits for the needs of the current moving packed bed concept. Data showing strong solar absorption of the particles validates the plan of using existing solar particle receivers with only a change in the particle type. Catalyst investigation showed that Pt 1 Sn 3 is the most viable candidate for developing PtSn catalysts for high temperature propane dehydrogenation, considering the balance of activity, selectivity, and deactivation. This project completed an initial study of various factors needed to incorporate a moving bed catalytic reactor for propane dehydrogenation into a concentrated solar thermal particle system. Future developments may allow this technology to be scaled up and help to use solar thermal energy to decarbonize not only the propane dehydrogenation reaction, but other gas-solid catalytic reactions at similar temperatures.

14 SOLAR ENERGY↗

Higher Efficiency, Demand Flexible Refrigerator with On-Demand Micro-Vibrational De-icing Technology

Refrigerator technology has advanced significantly over the last couple of decades. Today’s refrigerators use only about 25% of the energy that was required to power models built in 1975. Even as they continually improve efficiency to meet standards, refrigerators have increased in size by almost 20%, added energy-consuming features such as through-the-door ice, and provide more benefits than ever before. However, a few challenges and technology gaps are preventing further improvement of the demand responsiveness and efficiency of the refrigerators. One of the major technology gaps in existing refrigerators is their outdated de-icing process. When the evaporator generates frost, an old-fashioned resistive heating element melts the ice. Most refrigerators have a timed defrost cycle, rather than an active system that could monitor the state of the frost. In these systems, not only is the precious electricity used at its least efficient form of conversion (direct conversion of electricity to heat), but also all the latent heat associated with the ice is wasted during the melting process. On top of that, the refrigerator needs to work harder to pull the temperature down after defrosting, and, last but not least, the food quality is severely impacted by the temperature swings during the defrost cycle. According to a study, the EU alone wastes 89 million tons of food in the supply chain every year. Any temperature swing during defrosting (about 6F according to Emerson for low-temperature cases) can negatively impact the shelf life of meat and other products for multiple days. All these issues can happen during the peak demand time of the electric grid. Unlike the conventional systems, the proposed novel advanced micro-vibrational deicing process uses no heat for defrosting. Instead, it uses the micro vibrations generated by a piezoelectric or vibration-generating module to mechanically break ice from the heat exchanger almost instantaneously. The project titled “Higher Efficiency, Demand Flexible Refrigerator with On-Demand Micro-Vibrational De-icing Technology, performed by Ultrasonic Technology Solutions, LLC (UTS) of Knoxville, TN, in collaboration with Emerson (now Copeland), represents the final phase of a multi-year effort funded under the U.S. Department of Energy’s Building Technologies Office (BTO) BENEFIT FOA 2020. Initiated on October 1, 2021, and completed after a nine-month no-cost extension ending September 30, 2025, this project aimed to develop and validate a novel micro-vibrational mechanical defrosting system, achieving more than 25% improvement in defrosting energy efficiency over conventional baseline defrosting technologies. Over sixteen quarters, the project advanced from fundamental ice-mechanical characterization and prototype development to full-scale system integration and validation. Initial efforts established project management infrastructure and characterized ice adhesion properties, followed by the design and fabrication of early aluminum-based prototypes for resonance frequency testing. Subsequent quarters saw rapid technical progression, including the identification of optimal piezoelectric and motor-based vibration mechanisms, the demonstration of effective de-icing over 6x6-inch aluminum surfaces. The team achieved its Go/No-Go milestone by exceeding the 25% energy-efficiency improvement target—reaching up to 3,340% under optimized conditions—and later confirmed that motor-driven systems offered superior performance and energy efficiency compared to piezoelectric alternatives. Continued refinement led to the development of amplifier systems on printed circuit boards, improved control and instrumentation hardware, and integration into full-scale heat exchanger (HX) prototypes at both UTS and Copeland facilities. Multiple vibration-mounting studies and frost-growth experiments guided mechanical optimization and noise-mitigation strategies, achieving a 17.5 dB reduction in sound pressure level and verifying robust mechanical performance. Advanced analyses, including modal and harmonic simulations, established a quantitative understanding of vibrational behavior and de-icing efficiency across >1000 cm² systems. The final project phase successfully demonstrated scalable integration within reach-in and chest freezer prototypes, confirmed >25% efficiency improvements in large-area systems, and completed a comprehensive business model and scale-up strategy identifying electric defrost systems as the primary beachhead market. The culmination of this DOE-supported effort establishes micro-vibrational defrosting as a viable, high-efficiency, low-noise, and demand-flexible de-icing technology, paving the way for commercial deployment and broader application in next-generation refrigeration systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Real time heat load calculation software based on EPICS for Fermilab PIP-II CM tests

Fermilab has a project to improve the proton beam energy which is called PIP-II (the 2nd Proton Improvement Plan). There is a superconducting linear accelerator, LINAC, to improve the proton beam power and the LINAC consists of 5 types of cryomodules (CM), 1 HWR CM, 2 SSR1 CM, 4 SSR2 CM, LB650 CM, and HB650 CM. The prototypes of these cryomodules are being tested at Fermilab’s CryoModule Test Facility (CMTF). Heat load measurements are an important part of the prototype CM testing. The CMTF cryogenic control system was developed based on the ACNET (Accelerator Control NETwork) for CM testing for other projects, but the PIP-II cryogenic control system will be implemented using the Experimental Physics and Industrial Control System (EPICS). As part of the prototype CM testing campaign, an EPICS based control system has been implemented at CMTF. This EPICS cryogenic control system includes real-time heat load calculation software utilizing the Fortran implementation of Hepak. This paper details the real time heat load calculation software developed for the prototype CM testing including the first results from the HB650 CM.

Yoon, S. [Fermilab]↗

Heating performance of a vapor compression heat pump cascaded with a thermoelectric heat pump

Air source heat pumps (ASHPs) are widely utilized for heating and cooling in residential buildings; however, their effectiveness in heating mode is compromised during extreme weather conditions. Extensive research endeavors have been undertaken to develop, test, and assess a cost-effective vapor compression ASHP suitable for cold climate regions. Further, this study takes an innovative approach by developing component and system prototypes for a cold climate heat pump. This design combines a thermoelectric heat pump (TEHP) with a traditional residential split ASHP to augment heating capacity in low ambient temperature conditions. The component and system prototypes underwent experimental testing in the psychrometric chambers. The experimental findings revealed a 13.6% to 13.7% increase in total heat pump heating capacity, accompanied by a 3.1% to 5.0% decrease in the coefficient of performance (COP) at ambient temperatures of -15°C and -19°C, when compared to the original ASHP. The COP of the TEHP is relatively constant, ranging from 1.63 to 1.76. This prototype offers a solution to address the challenges associated with reduced heat pump capacity at low ambient temperatures. The experimental results indicated that the lower the ambient temperature, thermoelectric heat pump auxiliary heating can increase the heating efficiency 60% in comparison to electric resistance.

42 ENGINEERING↗

Novel thermal energy storage component: Development, performance, and phase transition diagnosis

Thermal energy storage (TES) using phase change materials (PCMs) is a promising technology for capturing and storing excess thermal energy for later use. However, challenges such as poor heat transfer efficiency and a lack of modular, scalable designs have limited widespread adoption of TES in real-world applications. This study developed and evaluated modular brick-type and blade-type TES prototypes featuring an aluminum housing, an embedded serpentine coil for active or passive thermal exchange, and a cost-effective metal mesh to enhance PCM thermal conductivity. The blade-type TES achieved notable geometric efficiency, with a thickness-to-length ratio of 0.03 and a thickness-to-width ratio of 0.08, enabling highly compact and modular thermal storage suitable for space-constrained applications. The paper presents a detailed evaluation of the TES prototypes’ performance. The comparative analysis indicated that the TES prototypes provide a highly cost-effective, thermally optimized alternative for compact energy storage and load shifting. A novel diagnostic technique was also introduced: using a portable endoscope to capture real-time visualizations of PCM phase transitions inside the TES. This method provides critical insights into internal heat transfer mechanisms, identifies potential issues, and offers valuable support for optimizing the TES design and developing the control algorithm. Overall, the modular brick-type and blade-type TES designs demonstrated in this work provide a scalable, efficient, and economically viable solution for advancing TES across residential, commercial, and industrial sectors. The designs’ compact structure, enhanced thermal performance, and integrated diagnostic capabilities make them strong candidates for future deployment in energy-efficient systems.

Gao, Zhiming [ORNL] (ORCID:0000000271397995)↗

Coupled heat and mass transfer in internally cooled silica gel-coated aluminum foam heat exchangers for dehumidification

Solid desiccant dehumidifiers offer significant potential to improve humidity control in buildings due to their ability to independently regulate latent (humidity) and sensible (temperature) loads. However, adsorption of water vapor by desiccants is an exothermic process; the resulting heat of adsorption increases both the desiccant bed temperature and the temperature of the air flowing over the bed, thereby limiting the performance of desiccant dehumidifiers. To address this problem, desiccant-coated heat exchanger prototypes were developed by coating silica gel onto aluminum foam substrates and integrated with chilled water circulation for effective removal of the heat of adsorption. Prototype heat exchangers with two different pore densities (10 and 20 pores per inch (PPI)) and two different desiccant loadings (∼10.36% and ∼17.80%) were fabricated. Experiments were conducted by varying the inlet air face velocity, chilled water inlet temperature, and chilled water flow rate to investigate the coupled heat and mass transfer characteristics of the prototype heat exchangers over a wide range of operating conditions. The underlying transport mechanisms were analyzed using transient desiccant bed temperature, outlet air temperature, and outlet humidity profiles. The results demonstrate that internal cooling significantly enhances dehumidification performance by maintaining more favorable thermodynamic conditions for water vapor adsorption. Under identical operating conditions, a 20 PPI heat exchanger coated with 25.05 g of silica gel achieved 98.98% higher cumulative water uptake and 97.75% higher moisture removal capacity than the corresponding non-cooled case after 5 min of adsorption. This substantial enhancement was further supported by a validated one-dimensional coupled heat and mass transfer model developed in the present study. To date, this is one of the first experimental studies to systematically investigate the combined effects of internal cooling, foam pore density, and desiccant loading on the performance of silica-gel-coated metal foam heat exchangers under HVAC-relevant operating conditions.

42 ENGINEERING↗