Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantitative image analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Analysis of High Contrast Imaging Techniques for Space Based Direct Planetary Imaging

We report on our ongoing investigations of a number of techniques for direct detection and imaging of Earth-like planets around nearby stellar sources. Herein, we give a quantitative analysis of these techniques and compare and contrast them via computer simulations. The techniques we will be reporting on are Bracewell Interferometry, Nisenson Apodized Square Aperture, and Coronagraphic masking techniques. We parameterize our results with respect to wavelength, aperture size, effects of mirror speckle, both mid- and high-spatial frequency, detector and photon noise as well pointing error. The recent numerous detections of Jupiter and Saturn like planets has driven a resurgence in research of space based high contrast imaging techniques for direct planetary imaging. Work is currently ongoing for concepts for NASA's Terrestrial Planet Finder mission and a number of study teams have been funded. The authors are members of one team.

Lyon, Richard G.↗

Defect and structural evolution under high-energy ion irradiation informs battery materials design for extreme environments

Understanding defect evolution and structural transformations constitutes a prominent research frontier for ultimately controlling the electrochemical properties of advanced battery materials. Herein, for the first time, we utilize in situ high-energy Kr ion irradiation with transmission electron microscopy to monitor how defects and microstructures evolve in Na- and Li-layered cathodes with 3d transition metals. Our experimental and theoretical analyses reveal that Li-layered cathodes are more resistant to radiation-induced structural transformations, such as amorphization than Na-layered cathodes. The underlying mechanism is the facile formation of Li-transition metal antisite defects in Li-layered cathodes. The quantitative mathematical analysis of the dynamic bright-field imaging shows that defect clusters preferentially align along the Na/Li ion diffusion channels ( a-b planes), which is likely governed by the formation of dislocation loops. Our study provides critical insights into designing battery materials for extreme irradiation environments and understanding fundamental defect dynamics in layered oxides.

25 ENERGY STORAGE↗

Synchrotron fluorescence imaging of individual mouse beta-cells reveals changes in zinc, calcium, and iron in a model of low-grade inflammation

Pancreatic beta-cells synthesize and secrete insulin maintaining an organism's energy homeostasis. In humans, beta-cell dysfunction and death contribute to the pathogenesis of type 2 diabetes (T2D). Although the causes of beta-cell dysfunction are complex, obesity-induced low-grade systemic inflammation plays a role. For example, obese individuals exhibiting increased levels of proinflammatory cytokines IL-6 and IL-1beta have a higher risk of beta-cell dysfunction and T2D. Interestingly, obesity-induced inflammation changes the expression of several cellular metal regulating genes, prompting this study to examine changes in the beta-cell metallome after exposure to proinflammatory-cytokines. Here, primary mouse beta-cells were exposed to a combination of IL-6 and IL-1beta for 48 hours, were chemically fixed and imaged by synchrotron X-ray fluorescent microscopy. Quantitative analysis showed a surprising 2.4-fold decrease in the mean total cellular content of zinc from 158 ± 57.7 femtograms (fg) to 65.7 ± 29.7 fg; calcium decreased from 216 ± 67.4 to 154.3 ± 68.7 fg (control vs. cytokines, respectively). The mean total cellular iron content slightly increased from 30.4 ± 12.2 to 47.2 ± 36.4 fg after cytokine treatment; a sub-population of cells (38%) exhibited larger increases of iron density. Changes in the subcellular distributions of zinc and calcium were observed after cytokine exposure. Beta-cells contained numerous iron puncta that accumulated still more iron after exposure to cytokines. These findings provide evidence that exposure to low levels of cytokines is sufficient to cause changes in the total cellular content and/or subcellular distribution of several metals known to be critical for normal beta-cell function.

59 BASIC BIOLOGICAL SCIENCES↗

Improvement in diastolic intraventricular pressure gradients in patients with HOCM after ethanol septal reduction

We sought to validate measurement of intraventricular pressure gradients (IVPG) and analyze their change in patients with hypertrophic obstructive cardiomyopathy (HOCM) after ethanol septal reduction (ESR). Quantitative analysis of color M-mode Doppler (CMM) images may be used to estimate diastolic IVPG noninvasively. Noninvasive IVPG measurement was validated in 10 patients undergoing surgical myectomy. Echocardiograms were then analyzed in 19 patients at baseline and after ESR. Pulsed Doppler data through the mitral valve and pulmonary venous flow were obtained. CMM was used to obtain the flow propagation velocity (Vp) and to calculate IVPG off-line. Left atrial pressure was estimated with the use of previously validated Doppler equations. Data were compared before and after ESR. CMM-derived IVPG correlated well with invasive measurements obtained before and after surgical myectomy [r = 0.8, P < 0.01, Delta(CMM - invasive IVPG) = 0.09 +/- 0.45 mmHg]. ESR resulted in a decrease of resting LVOT systolic gradient from 62 +/- 10 to 29 +/- 5 mmHg (P < 0.001). There was a significant increase in the Vp and IVPG (from 48 +/- 5to 74 +/- 7 cm/s and from 1.5 +/- 0.2 to 2.6 +/- 0.3 mmHg, respectively, P < 0.001 for both). Estimated left atrial pressure decreased from 16.2 +/- 1.1 to 11.5 +/- 0.9 mmHg (P < 0.001). The increase in IVPG correlated with the reduction in the LVOT gradient (r = 0.6, P < 0.01). Reduction of LVOT obstruction after ESR is associated with an improvement in diastolic suction force. Noninvasive measurements of IVPG may be used as an indicator of diastolic function improvement in HOCM.

NASA Program Biomedical Research and Countermeasur↗

Few-femtosecond resolved imaging of laser-driven nanoplasma expansion

Abstract The free expansion of a planar plasma surface is a fundamental non-equilibrium process relevant for various fields but as-yet experimentally still difficult to capture. The significance of the associated spatiotemporal plasma motion ranges from astrophysics and controlled fusion to laser machining, surface high-harmonic generation, plasma mirrors, and laser-driven particle acceleration. Here, we show that x-ray coherent diffractive imaging can surpass existing approaches and enables the quantitative real-time analysis of the sudden free expansion of laser-heated nanoplasmas. For laser-ionized SiO 2 nanospheres, we resolve the formation of the emerging nearly self-similar plasma profile evolution and expose the so far inaccessible shell-wise expansion dynamics including the associated startup delay and rarefaction front velocity. Our results establish time-resolved diffractive imaging as an accurate quantitative diagnostic platform for tracing and characterizing plasma expansion and indicate the possibility to resolve various laser-driven processes including shock formation and wave-breaking phenomena with unprecedented resolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A quantitative imaging framework for lithium morphology: Linking deposition uniformity to cycle stability in lithium metal batteries

Characterizing the morphology of lithium (Li) is crucial for developing long-lasting lithium metal batteries. It is well established that more uniform Li deposition correlates with better cell performance. Li morphology is often characterized through qualitative analysis of scanning electron microscopy (SEM) images; however, there are no widely accepted metrics to quantitatively describe deposition uniformity. Here, we propose a framework to quantify uniformity through SEM image analysis via the index of dispersion (ID) metric, which is defined and presented in the context of Li metal batteries. We also explore experimental impacts of sampling protocols onIDmeasurements. Our results demonstrate that theIDmetric is highly sensitive to variations in deposition uniformity, including the coexistence and uniformity of multiple morphologies, uniformity within a single morphology, and particle size distribution uniformity. Furthermore, it is demonstrated that uniformity, as measured by theID, can be related to the average potential of Li||Li symmetric cells over cycling. Higher capacity cycling leads to more pronounced changes in bothIDand average cell potential. Local minima/maxima are found consistently in bothIDand average cell potential immediately before cells short-circuit, which we suggest may indicate a collapse of the microstructure prior to failure. We put forward this framework as a more robust approach to quantify Li deposition uniformity, advancing the development of Li metal batteries that are safer and longer lasting.

Science & Technology - Other Topics↗

Proposal for a study of computer mapping of terrain using multispectral data from ERTS-A for the Yellowstone National Park test site

The author has identified the following significant results. A terrain map of Yellowstone National Park showed plant community types and other classes of ground cover in what is basically a wild land. The map comprised 12 classes, six of which were mapped with accuracies of 70 to 95%. The remaining six classes had spectral reflectances that overlapped appreciably, and hence, those were mapped less accurately. Techniques were devised for quantitatively comparing the recognition map of the park with control data acquired from ground inspection and from analysis of sidelooking radar images, a thermal IR mosaic, and IR aerial photos of several scales. Quantitative analyses were made in ten 40 sq km test areas. Comparison mechanics were performed by computer with the final results displayed on line printer output. Forested areas were mapped by computer using ERTS data for less than 1/4 the cost of the conventional forest mapping technique for topographic base maps.

Smedes, H. W.↗

Robust collection and processing for label-free single voxel proteomics

With advanced mass spectrometry (MS)-based proteomics, genome-scale proteome coverage can be achieved from bulk tissues. However, such bulk measurement lacks spatial resolution and obscures tissue heterogeneity, precluding proteome mapping of tissue microenvironment. Here we report an integrated $\underline{w}et$ $\underline{c}ollection$ of single microscale tissue voxels and $\underline{S}urfactant$$-assisted$ $\underline{O}ne$-$\underline{P}ot$ voxel processing method termed wcSOP for robust label-free single voxel proteomics. wcSOP capitalizes on buffer droplet-assisted wet collection of a single voxel dissected by LCM into the PCR tube cap and MS-compatible surfactant-assisted one-pot voxel processing in the collection cap. This convenient method allows reproducible label-free quantification of ~900 and ~4,600 proteins for single voxels at 20 µm × 20 µm × 10 µm (close to single cells) and 200 µm × 200 µm × 10 µm (~100 cells) from fresh frozen human spleen tissue, respectively. 100s-1000s of protein signatures were spatially resolved between spleen red and white pulp regions depending on the voxel size. Region-specific signaling pathways were enriched from single voxel proteomics data. To evaluate its broad applicability, we applied wcSOP-MS to two commonly accessible, OCT-embedded and FFPE, human archived tissues. It enabled to identify spatially resolved proteome changes and enriched pathways between diseased (breast cancer tumor or AD amyloid plaque) and adjacent normal regions. Antibody-based CODEX and IHC imaging validated label-free MS quantitation for single voxel analysis. The wcSOP-MS method paves the way for routine robust single voxel proteomics and spatial proteomics.

59 BASIC BIOLOGICAL SCIENCES↗

An empirical method for geometric calibration of a photon counting detector-based cone beam CT system

BACKGROUND: Geometric calibration is essential in developing a reliable computed tomography (CT) system. It involves estimating the geometry under which the angular projections are acquired. Geometric calibration of cone beam CTs employing small area detectors, such as currently available photon counting detectors (PCDs), is challenging when using traditional-based methods due to detectors’ limited areas. OBJECTIVE: This study presented an empirical method for the geometric calibration of small area PCD-based cone beam CT systems. METHODS: Unlike the traditional methods, we developed an iterative optimization procedure to determine geometric parameters using the reconstructed images of small metal ball bearings (BBs) embedded in a custom-built phantom. An objective function incorporating the sphericities and symmetries of the embedded BBs was defined to assess performance of the reconstruction algorithm with the given initial estimated set of geometric parameters. The optimal parameter values were those which minimized the objective function. The TIGRE toolbox was employed for fast tomographic reconstruction. To evaluate the proposed method, computer simulations were carried out using various numbers of spheres placed in various locations. Furthermore, efficacy of the method was experimentally assessed using a custom-made benchtop PCD-based cone beam CT. RESULTS: Computer simulations validated the accuracy and reproducibility of the proposed method. The precise estimation of the geometric parameters of the benchtop revealed high-quality imaging in CT reconstruction of a breast phantom. Within the phantom, the cylindrical holes, fibers, and speck groups were imaged in high fidelity. The CNR analysis further revealed the quantitative improvements of the reconstruction performed with the estimated parameters using the proposed method. CONCLUSION: Apart from the computational cost, we concluded that the method was easy to implement and robust.

Instruments & Instrumentation↗

Recent advances in geologic mapping by radar

Quantitative techniques are available which allow the analysis of SAR images for the derivation of geological surface and process data. In conjunction with calibrated radar sensors operating at several incidence angles, wavelengths, and polarizations, the compilation of multiparameter radar signatures of lithological and geomorphic units can accordingly proceed for geological mapping in unknown areas. While radar image tone can be used in arid zones to derive surface micromorphology, heavily vegetated tropical regions require the analysis of radar image texture by means of Fourier techniques which decompose the image into bandpasses that represent different scales of texture.

Farr, T. G.↗

Automated Bacterial Identification and Morphological Feature Analysis in Low‐Dose Cryo‐EM Using YOLOv11

Bacteria rapidly adapt to environmental cues through morphological and ultrastructural changes that correlate with physiology and behavior. Cryogenic transmission electron microscopy (cryo‐TEM) can capture these phenotypic changes in near‐native, vitrified states, but manual analysis of low‐dose micrographs is labor intensive and limits throughput. Here, we present an end‐to‐end workflow that combines low‐dose cryo‐TEM imaging with a YOLOv11‐based instance‐segmentation model to automatically identify bacteria and quantify key structural features directly from the micrographs. This workflow enables (i) robust bacterial localization and counting from low‐magnification atlas/montage images, (ii) automated measurements of cell‐envelope (outer–inner membrane) thickness and anisotropy from higher‐magnification views, and (iii) detection and quantification of bacteria–flagella interactions, including overlap length and curvature metrics for interacting versus noninteracting flagella. Using Pantoea sp. YR343 grown under distinct media conditions, we show that the automated measurements agree with manual annotations while substantially reducing analysis time. Together, these tools provide a practical framework for scalable bacterial identification and quantitative phenotyping in low‐dose cryo‐TEM datasets and establish a foundation for extending cryo‐TEM image analysis toward higher‐throughput studies of microbial heterogeneity and biointerfaces.

YOLOv11↗

Light microscopic image analysis system to quantify immunoreactive terminal area apposed to nerve cells

The present report describes a desktop computer-based method for the quantitative assessment of the area occupied by immunoreactive terminals in close apposition to nerve cells in relation to the perimeter of the cell soma. This method is based on Fast Fourier Transform (FFT) routines incorporated in NIH-Image public domain software. Pyramidal cells of layer V of the somatosensory cortex outlined by GABA immunolabeled terminals were chosen for our analysis. A Leitz Diaplan light microscope was employed for the visualization of the sections. A Sierra Scientific Model 4030 CCD camera was used to capture the images into a Macintosh Centris 650 computer. After preprocessing, filtering was performed on the power spectrum in the frequency domain produced by the FFT operation. An inverse FFT with filter procedure was employed to restore the images to the spatial domain. Pasting of the original image to the transformed one using a Boolean logic operation called 'AND'ing produced an image with the terminals enhanced. This procedure allowed the creation of a binary image using a well-defined threshold of 128. Thus, the terminal area appears in black against a white background. This methodology provides an objective means of measurement of area by counting the total number of pixels occupied by immunoreactive terminals in light microscopic sections in which the difficulties of labeling intensity, size, shape and numerical density of terminals are avoided.

Non-NASA Center↗

Analysis of the density field around a supersonic conical projectile using quantitative schlieren

Quantitative schlieren imaging is a flow measurement technique that is capable of measuring density fields throughout refractive flowfields. The technique was applied here to measure the density field surrounding supersonic conical projectiles in free flight. Shock waves attached to a supersonic conical projectile offer a simple geometry with the well-established Taylor–Maccoll analytical flow solution to which these experimental measurements were compared. The schlieren images recorded a projection of the index of refraction field surrounding the 10° half-angle cones which was converted to density first through an Abel inversion and then the Gladstone–Dale law. Three Abel inversion methods—two-point, three-point, and arbitrary ray axisymmetric projection (ARAP)—were applied to deconvolute the three-dimensional flow within the constrained axisymmetric flow field. The resulting reconstructed density profiles were compared to the Taylor–Maccoll solution, parameterized by cone geometry and Mach number. The experimental density fields demonstrated strong agreement with the theoretical profiles. Experimental consistency was confirmed across various projectile speeds, demonstrating quantitative schlieren’s capability to accurately reconstruct the density of the flow field, even within the resolution constraints imposed by high-speed imaging. In conclusion, an assessment of experimental uncertainties in the density reconstruction was performed.

Abel Inversion↗

The use of multidate multichannel radiance data in urban feature analysis

Two images were obtained from thematic mappers on Landsats 4 and 5 over the Washington, DC area during November 1982 and March 1984. Selected training areas containing different types of urban land use were examined,one area consisting entirely of forest. Mean digital radiance values for each bandpass in each image were examined, and variances, standard deviations, and covariances between bandpasses were calculated. It has been found that two bandpasses caused forested areas to stand out from other land use types, especially for the November 1982 image. In order to evaluate quantitatively the possible utility of the principal components analysis in selected feature extraction, the eigenvectors were evaluated for principal axes rotations which rendered each selected land use type most separable from all other land use types. The evaluated eigenvectors were plotted as a function of land use type, whose order was decided by considering anticipated shadow component and by examining the relative loadings indicative of vegetation for each of the principal components for the different features considered. The analysis was performed for each seven-band image separately and for the two combined images. It was found that by combining the two images, more dramatic land use type separation could be obtained.

Duggin, M. J.↗

Electron-Beam Diagnostic Methods for Hypersonic Flow Diagnostics

The purpose of this work was the evaluation of the use of electron-bean fluorescence for flow measurements during hypersonic flight. Both analytical and numerical models were developed in this investigation to evaluate quantitatively flow field imaging concepts based upon the electron beam fluorescence technique for use in flight research and wind tunnel applications. Specific models were developed for: (1) fluorescence excitation/emission for nitrogen, (2) rotational fluorescence spectrum for nitrogen, (3) single and multiple scattering of electrons in a variable density medium, (4) spatial and spectral distribution of fluorescence, (5) measurement of rotational temperature and density, (6) optical filter design for fluorescence imaging, and (7) temperature accuracy and signal acquisition time requirements. Application of these models to a typical hypersonic wind tunnel flow is presented. In particular, the capability of simulating the fluorescence resulting from electron impact ionization in a variable density nitrogen or air flow provides the capability to evaluate the design of imaging instruments for flow field mapping. The result of this analysis is a recommendation that quantitative measurements of hypersonic flow fields using electron-bean fluorescence is a tractable method with electron beam energies of 100 keV. With lower electron energies, electron scattering increases with significant beam divergence which makes quantitative imaging difficult. The potential application of the analytical and numerical models developed in this work is in the design of a flow field imaging instrument for use in hypersonic wind tunnels or onboard a flight research vehicle.

Source record↗

Quantitative Scanning Transmission Electron Microscopy for Materials Science: Imaging, Diffraction, Spectroscopy, and Tomography

Scanning transmission electron microscopy (STEM) is one of the most powerful characterization tools in materials science research. Due to instrumentation developments such as highly coherent electron sources, aberration correctors, and direct electron detectors, STEM experiments can examine the structure and properties of materials at length scales of functional devices and materials down to single atoms. STEM encompasses a wide array of flexible operating modes, including imaging, diffraction, spectroscopy, and 3D tomography experiments. This review outlines many common STEM experimental methods with a focus on quantitative data analysis and simulation methods, especially those enabled by open source software. The hope is to introduce both classic and new experimental methods to materials scientists and summarize recent progress in STEM characterization. The review also discusses the strengths and weaknesses of the various STEM methodologies and briefly considers promising future directions for quantitative STEM research.

36 MATERIALS SCIENCE↗

Analytical and experimental design and analysis of an optimal processor for image registration

The author has identified the following significant results. A quantitative measure of the registration processor accuracy in terms of the variance of the registration error was derived. With the appropriate assumptions, the variance was shown to be inversely proportional to the square of the effective bandwidth times the signal to noise ratio. The final expressions were presented to emphasize both the form and simplicity of their representation. In the situation where relative spatial distortions exist between images to be registered, expressions were derived for estimating the loss in output signal to noise ratio due to these spatial distortions. These results are in terms of a reduction factor.

Mcgillem, C. D.↗