Search NASA⌕ Search

SEARCH · Search NASA

Results for “quartz”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Post-flight analyses of the crystals from the M0003-14 quartz crystal microbalance experiment

Quartz Crystal Microbalances constructed by QCM Research were flown on the leading and trailing edges of LDEF as one of the sub-experiments of M0003. Response of the crystals coated with 150 A of In2O3 was recorded during the first 424 days of the mission. A second QCM with crystals coated with 150 A of ZnS was also flown but not monitored. After the flight, the QCM's were disassembled and analyzed in The Aerospace Corporation laboratories. The samples included the crystals from the leading and trailing edge samples of both types of coatings along with the reference crystals, which were inside the QCM housing. Analyses were performed by scanning electron microscopy, energy dispersive x-ray analyses, x-ray photoelectron spectroscopy, ion microprobe mass analysis, and reflectance spectroscopy in the infrared and UV/visible regions. The crystals are contaminated predominantly with silicone compounds. The contamination is higher on the leading edge than on the trailing edge and higher on the exposed crystals than on the reference crystals.

Stuckey, W. K.↗

Compensation for 6.5 K cryogenic distortion of a fused quartz mirror by refiguring

A 46 cm diameter, lightweight, Amersil TO8E, fused-natural-quartz mirror with a single-arch cross section was tested at the NASA-Ames Research Center Cryogenic Optical Test Facility to measure its cryogenic distortion at 6.5 K. Then the mirror was refigured with the inverse of the measured cryogenic distortion to compensate for this figure defect. The mirror was retested at 6.5 K and found to have a significantly improved figure. The compensation for cryogenic distortion was not complete, but preliminary analysis indicates that the compensation was better than 0.25 waves P-V if edge effects are ignored. The feasibility of compensating for cryogenic distortion by refiguring has thus been verified.

Augason, Gordon C.↗

A dynamic melting model for the origin of Apollo 15 olivine-normative and quartz-normative mare basalts

Early studies of mare basalts from the Apollo 15 site established that two distinct groups are represented: the olivine-normative basalts (ONB) and the quartz-normative basalts (QNB). The ONB and QNB suites are distinguished petrographically by their phenocryst assemblages (the ONB's are olivine-phyric, the QNB's are generally pyroxene-phyric) and chemically by their major element compositions: the QNB's are higher in SiO2 and MgO/FeO, and lower in FeO and TiO2 than ONB's with similar MgO contents. Experimental data show that the QNB suite is derived from a more magnesian, olivine-normative parent magma, a conclusion which is supported by the recent discovery of high-SiO2 olivine-normative basalt clasts in breccia 15498. The high-SiO2 ONB's fall on olivine control lines with primitive QNB's, and least-squares mixing calculations are consistent with the high-SiO2 ONB's being parental to the more evolved QNB suite. These high-SiO2 ONB's are included as part of the 'QNB suite'. Our major element modeling results also are consistent with the conclusions of earlier studies which showed that the ONB and QNB suites cannot be related to one another by low pressure crystal fractionation. The combination of high Mg#, high SiO2, and low TiO2 in the QNB suite precludes a relationship to the ONB suite by simple removal of liquidus minerals (olivine and pigeonite). Despite these significant differences in petrography and major element composition, both groups have nearly identical trace element concentrations and chondrite-normalized abundance patterns. The major question to be addressed by any petrogenetic model for Apollo 15 mare basalts is how to form mare basalt suites with distinctly different major element characteristics but nearly identical trace element compositions. The similarity in trace element concentrations imply compositionally similar source regions and similar percent melting, but these conclusions are not easily reconciled with the observed differences in major element compositions, which require sources with distinct mineralogies or large differences in percent melt.

Vetter, Scott K.↗

Calorimetric thermobarometry of experimentally shocked quartz

Structural damage in experimentally shock-metamorphosed, granular quartz is quantitatively measurable by differential scanning calorimetry (DSC). Shock-induced loss of crystallinity is witnessed by disappearance of the alpha/beta phase transformation and evolution of a broad endoenthalpic strain peak at 650-900 K. The strain-energy peak grows rapidly at less than 10 GPa but declines with increasing shock pressure; it approaches zero at 32 GPa where vitrification is extensive. Effects of grain size and post-shock thermal history must be better understood before calorimetric thermobarometry of naturally shocked samples becomes possible.

Ocker, Katherine D.↗

Using a temperature-controlled quartz crystal microbalance in a space equipment cleanroom to monitor molecular contamination

There is a need for continuous monitoring for molecular contamination in clean rooms where spaceflight equipment is assembled, integrated, and tested to insure that contamination budgets are met. The TQCM (temperature-controlled quartz crystal microbalance) can be used to provide both a real time warning and a cumulative measurement of molecular contamination. It has advantages over the other measurement methods such as witness mirrors, NVR (non-volatile residue) plates, and gas analyzers. A comparison of the TQCM sensitivity and ease of operations is made with the other methods. The surface acoustic wave microbalance (SAW), a newly developed instrument similar to TQCM, is considered in the comparison. An example is provided of TQCM use at Goddard Space Flight Center when the Wide Field Planetary Camera 2(WFPC-2) and the Corrective Optics Space Telescope Axial Replacement (COSTAR) were undergoing integrated testing prior to their installation in the Hubble Space Telescope on its first servicing mission. Areas for further investigation are presented.

Mitchell, William J.↗

Some Sources of Contaminants in the Shuttle Bay Measured with Temperature-Controlled Quartz Crystal Microbalances (TQCM)

The sources of molecular deposits on a Temperature-Controlled Quartz Crystal Microbalance (TQCM) attached to the shuttle bay wall at some distance from the payload and pointing out of the bay have been investigated. Explored as possible sources are: (1) the outgassing of the shuttle tiles treated with the water proofing di-methyl-ethoxy-silane (DMES) compound, scattered back by the ambient molecules into the bay; (2) The ambient scattered return flux of the outgassing, from the RTV 560 silicone which is used as the adhesive for the tiles; (3) the ambient scattered return flux of the payload outgassing; (4) the return C, flux from outgassing source originating near, below, or adjacent to the package containing the TQCM; and (5) the self-scattering of venting plumes and outgassing above the monitor package depositing on the TQCM. In all of these sources, the magnitudes of the outgassing, of the leakage rates, and venting had to be estimated in the absence of data. The resulting analyses which can be useful for similar investigations, indicates that the outgassin- from the tiles, the RTV, the payloads, or the shuttle may not have been the sources of the deposit (about 1 micro g/cm(sup 2) during a the period from bay door opening and payload release from the bay). It appears more probable that the origin is the self- and/or ambient-scattered return fluxes originating near, below, or internal to the monitor package.

Scialdone, John J.↗

Gas Dynamics, Characterization, and Calibration of Fast Flow Flight Cascade Impactor Quartz Crystal Microbalances (QCM) for Aerosol Measurements

During recent high altitude flights, we have tested the aerosol section of the fast flow flight cascade impactor quartz crystal microbalance (QCM) on loan to Howard University from NASA. The aerosol mass collected during these flights was disappointingly small. Increasing the flow through the QCM did not correct the problem. It was clear that the instrument was not being operated under proper conditions for aerosol collect ion primarily because the gas dynamics is not well understood. A laboratory study was therefore undertaken using two different fast flow QCM's in an attempt to establish the gas flow characteristics of the aerosol sections and its effect on particle collection, Some tests were made at low temperatures but most of the work reported here was carried out at room temperature. The QCM is a cascade type impactor originally designed by May (1945) and later modified by Anderson (1966) and Mercer et al (1970) for chemical gas analysis. The QCM has been used extensively for collecting and sizing stratospheric aerosol particles. In this paper all flow rates are given or corrected and referred to in terms of air at STP. All of the flow meters were kept at STP. Although there have been several calibration and evaluation studies of moderate flow cascade impactors of less than or equal to 1 L/rein., there is little experimental information on the gas flow characteristics for fast flow rates greater than 1 L/rein.

Grant, J.R.↗

Two-Step Calibration of a Multiwavelength Pyrometer for High Temperature Measurement Using a Quartz Lamp

There is no theoretical upper temperature limit for pyrometer application in temperature measurements. NASA Glenn's multiwavelength pyrometer can make measurements over wide temperature ranges. However, the radiation spectral response of the pyrometer's detector must be calibrated before any temperature measurement is attempted, and it is recommended that calibration be done at temperatures close to those for which measurements will be made. Calibration is a determination of the constants of proportionality at all wavelengths between the detector's output (voltage) and its input signals (usually from a blackbody radiation source) in order to convert detector output into radiation intensity. To measure high temperatures, the detectors are chosen to be sensitive in the spectral range from 0.4 to 2.5 micrometers. A blackbody furnace equilibrated at around 1000 C is often used for this calibration. Though the detector may respond sensitively to short wavelengths radiation, a blackbody furnace at 1000 C emits only feebly at very short wavelengths. As a consequence, the calibration constants that result may not be the most accurate. For pyrometry calibration, a radiation source emitting strongly at the short wavelengths is preferred. We have chosen a quartz halogen lamp for this purpose.

Ng, Daniel↗

Observation of Quartz Cathode-Luminescence in a Low Pressure Plasma Discharge

Intense, steady-state cathode-luminescence has been observed from exposure of quartz powder to a low pressure rf-excited argon plasma discharge. The emission spectra (400 to 850 nm) associated with the powder luminescence were documented as a function of bias voltage using a spectrometer. The emission was broad-band, essentially washing out the line spectra features of the argon plasma discharge.

Foster, John E.↗

Quartz Crystal Microbalance Operation and In Situ Calibration

Quartz crystal microbalances (QCMs) are commonly used to measure the rate of deposition of molecular species on a surface. The measurement is often used to select materials with a low outgassing rate for applications where the material has a line of sight to a contamination-sensitive surface. A quantitative, in situ calibration of the balance, or balances, using a pure material for which the enthalpy of sublimation is known, is described in this Technical Memorandum. Supporting calculations for surface dwell times of deposited materials and the effusion cell Clausing factor are presented along with examples of multiple QCM measurements of outgassing from a common source.

Albyn, K. C.↗

Quartz Microbalance Study of 400-angstrom Thick Films near the lambda Point

In a recent measurement we observed the thinning of an adsorbed helium film induced by the confinement of critical fluctuations a few millikelvin below the lambda point. A capacitor set-up was used to measure this Casimir effect. In this poster we will present our measurement of an adsorbed helium film of 400 angstroms near the lambda point with a quartz microbalance. For films this thick, we must take into account the non-linear dynamics of the shear waves in the fluid. In spite of the added complications, we were able to confirm the thinning of the film due to the Casimir effect and the onset of the superfluid transition. In addition, we observe a sharp anomaly at the bulk lambda point, most likely related to critical dissipation of the first sound. This work is carried out in collaboration with Rafael Garcia, Stephen Jordon and John Lazzaretti. This work is funded by NASA's Office of Biological and Physical Research under grant.

Chan, Moses H. W.↗

Vacuum Ultraviolet Radiation Desorption of Molecular Contaminants Deposited on Quartz Crystal Microbalances

Recent quartz crystal microbalance measurements made in the Marshall Space Flight Center, Photo-Deposition Facility, for several materials, recorded a significant loss of deposited contaminants when the deposition surface of the microbalance was illuminated by a deuterium lamp. These measurements differ from observations made by other investigators in which the rate of deposition increased significantly when the deposition surface was illuminated with vacuum ultraviolet radiation. These observations suggest that the accelerated deposition of molecular contaminants on optically sensitive surfaces is dependant upon the contaminant being deposited and must be addressed during the materials selection process by common material screening techniques.

Albyn, Keith↗

In-Flight Performance of the Cassini Hemispherical Quartz Resonator Gyro Inertial Reference Units

The Cassini-Huygens mission is a flagship class NASA/ESA mission to the planet Saturn. Launched in 1997, Cassini is still successfully operating after 16 years of flight and the telemetry from the attitude control hardware on Cassini has produced an immense dataset that allows the Cassini operations team to report on the long-term performance of several commercially available GNC hardware components in the space environment. This investigation summarizes the in-flight performance of the two inertial reference units aboard Cassini. Each of the two Cassini inertial reference units contains four hemispherical quartz resonator gyros. The Cassini operations team previously reported on the performance of the inertial reference units in 2007, and this paper provides an update with an additional 6 years of flight experience at Saturn.

guidance, navigation, and control (GNC)↗

Development of an Ablative 3D Quartz / Cyanate Ester Composite for the Orion Spacecraft Compression Pad

With the successful flight test of the Orion Multipurpose Crew Vehicle last December, NASA is well on its way to sending humans into deep space with the goal of putting astronauts on Mars in the 2030s. Orion will receive some upgrades for its next launch in 2018 including a newly developed 3D Quartz Cyanate Ester composite material for the compression pad. The compression pads are 10-inches in diameter and 3-inches thick. The pucks are at 4 locations in the heat shield that serve as a part of the mechanism for holding the Crew and Service modules together during most mission phases prior to separation followed by Earth re-entry. Thus the compression pad has structural, aerothermal and thermal protection requirements.This paper describes the approach used for developing the new 3D composite, including continuous 3D weaving on an automated loom followed by resin transfer molding. Mechanical, thermal and arc jet testing of the 3D composite are also described.

Feldman, Jay↗

Development of an Ablative 3D Quartz / Cyanate Ester Composite for the Orion Spacecraft Compression Pad

With the successful flight test of the Orion Multipurpose Crew Vehicle last December, NASA is well on its way to sending humans into deep space with the ultimate goal of putting astronauts on Mars in the 2030s. Orion will receive some upgrades for its next launch in 2018 including a newly developed 3D quartz / cyanate ester composite material for the compression pad. Multiple pad locations in the heat shield serve as a part of the mechanism for holding the Crew and Service Modules together during most mission phases prior to separation followed by Earth re-entry of the Crew Module. Thus the compression pad must survive structural and aerothermal loads, and protect the adjascent structure and heat shield materials from over-heating.This paper describes the approach used for developing the new 3D composite, including continuous 3D weaving on an automated loom followed by resin transfer molding. Mechanical, thermal, arc jet ,and stress relaxation testing of the 3D composite are also described.

Feldman, Jay D.↗

A Method for Incorporating Quartz Crystal Microbalance Thermo-Gravimetric Assessment Data in Contamination Modeling

The science objectives of increasingly ambitious space missions require meeting stringent contamination requirements. Contamination transport models are based on established principles such as Fick’s law for contamination diffusion within the source material, Arrhenius factors to account for temperature variations and free molecular transport for spacecraft operating in vacuum. In addition to the science principles, empirical data obtained from ASTM E1559 testing is used for engineering contamination modeling. The ASTM E1559 test provides outgassing rate data for materials at expected spacecraft temperatures during a mission. Multiple quartz crystal microbalances (QCMs) can be operated at different temperatures to measure the amount of contamination condensation that can occur on various spacecraft surfaces. At the conclusion of the ASTM E1559 test a thermo-gravimetric assessment (TGA) can be performed by heating the QCMs at a linear rate to obtain contamination desorption data. This TGA data provides a wealth of information that can be incorporated into contamination models. A method for applying this data is presented.

Anderson, John R↗