Search NASA⌕ Search

SEARCH · Search NASA

Results for “radiation dose estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Impurity color centers in quartz and trapped electron dating - Electron spin resonance, thermoluminescence studies.

Investigation of impurity-related electron-hole traps that are known to be sensitive to ionizing radiations. Electron spin resonance (ESR) equivalent natural doses were determined for the Al hole trap in virgin specimens; the doses agreed with estimates based on published data for the Ge electron trap. The 0.17 deg/sec 180 and 300 C thermoluminescence (TL) peaks in natural specimens were found to have activation energies approximately correct for the Ge trap. The 300 C peak was also found to be correlated with annealing of the Ge electron resonance in gamma-irradiated, step-annealed specimens. Although the 300 C peak occurs in virgin specimens, the corresponding natural Ge electron resonance was not observed.

Mcmorris, D. W.↗

Modeling Acute Health Effects of Astronauts from Exposure to Large Solar Particle Events

In space exploration outside the Earth s geomagnetic field, radiation exposure from solar particle events (SPE) presents a health concern for astronauts, that could impair their performance and result in possible failure of the mission. Acute risks are of special concern during extra-vehicular activities because of the rapid onset of SPE. However, most SPEs will not lead to acute risks but can lead to mission disruption if accurate projection methods are not available. Acute Radiation Sickness (ARS) is a group of clinical syndromes developing acutely (within several seconds to 3 days) after high dose whole-body or significant partial-body ionizing radiation exposures. The manifestation of these syndromes reflects the disturbance of physiological processes of various cellular groups damaged by radiation. Hematopoietic cells, skin, epithelium, intestine, and vascular endothelium are among the most sensitive tissues of human body to ionizing radiation. Most ARS symptoms are directly related to these tissues and other systems (nervous, endocrine, and cardiovascular, etc.) with coupled regulations. Here we report the progress in bio-mathematical models to describe the dose and time-dependent early human responses to ionizing radiation. The responses include lymphocyte depression, granulocyte modulation, fatigue and weakness syndrome, and upper gastrointestinal distress. The modest dose and dose-rates of SPEs are predicted to lead to large sparing of ARS, however detailed experimental data on a range of proton dose-rates for organ doses from 0.5 to 2 Gy is needed to validate the models. We also report on the ARRBOD code that integrates the BRYNTRN and SUMDOSE codes, which are used to estimate the SPE organ doses for astronauts under various space travel scenarios, with our models of ARS. The more recent effort is to provide easy web access to space radiation risk assessment using the ARRBOD code.

Hu, Shaowen↗

Radiation Dose Testing on Juno High Voltage Cables

The Juno mission to Jupiter will have a highly elliptical orbit taking the spacecraft through the radiation belts surrounding the planet. During these passes through the radiation belts, the spacecraft will be subject to high doses of radiation from energetic electrons and protons with energies ranging from 10 keV to 1 GeV. While shielding within the spacecraft main body will reduce the total absorbed dose to much of the spacecraft electronics, instruments and cables on the outside of the spacecraft will receive much higher levels of absorbed dose. In order to estimate the amount of degradation to two such cables, testing has been performed on two coaxial cables intended to provide high voltages to three of the instruments on Juno. Both cables were placed in a vacuum of 5x10-6 torr and cooled to -50 C prior to exposure to the radiation sources. Measurements of the coaxial capacitance per unit length and partial discharge noise floor indicate that increasing levels of radiation make measurable but acceptably small changes to the F EP Teflon utilized in the construction of these cables. In addition to the radiation dose testing, observations were made on the internal electrostatic charging characteristics of these cables and multiple discharges were recorded.

Juno↗

Automation of PCXMC and ImPACT for NASA Astronaut Medical Imaging Dose and Risk Tracking

To automate astronaut organ and effective dose calculations from occupational X-ray and computed tomography (CT) examinations incorporating PCXMC and ImPACT tools and to estimate the associated lifetime cancer risk per the National Council on Radiation Protection & Measurements (NCRP) using MATLAB(R). Methods: NASA follows guidance from the NCRP on its operational radiation safety program for astronauts. NCRP Report 142 recommends that astronauts be informed of the cancer risks from reported exposures to ionizing radiation from medical imaging. MATLAB(R) code was written to retrieve exam parameters for medical imaging procedures from a NASA database, calculate associated dose and risk, and return results to the database, using the Microsoft .NET Framework. This code interfaces with the PCXMC executable and emulates the ImPACT Excel spreadsheet to calculate organ doses from X-rays and CTs, respectively, eliminating the need to utilize the PCXMC graphical user interface (except for a few special cases) and the ImPACT spreadsheet. Results: Using MATLAB(R) code to interface with PCXMC and replicate ImPACT dose calculation allowed for rapid evaluation of multiple medical imaging exams. The user inputs the exam parameter data into the database and runs the code. Based on the imaging modality and input parameters, the organ doses are calculated. Output files are created for record, and organ doses, effective dose, and cancer risks associated with each exam are written to the database. Annual and post-flight exposure reports, which are used by the flight surgeon to brief the astronaut, are generated from the database. Conclusions: Automating PCXMC and ImPACT for evaluation of NASA astronaut medical imaging radiation procedures allowed for a traceable and rapid method for tracking projected cancer risks associated with over 12,000 exposures. This code will be used to evaluate future medical radiation exposures, and can easily be modified to accommodate changes to the risk calculation procedure.

Bahadori, Amir↗

Non-Targeted Effects and the Dose Response for Heavy Ion Tumorigenesis

BACKGROUND: There is no human epidemiology data available to estimate the heavy ion cancer risks experienced by astronauts in space. Studies of tumor induction in mice are a necessary step to estimate risks to astronauts. Previous experimental data can be better utilized to model dose response for heavy ion tumorigenesis and plan future low dose studies. DOSE RESPONSE MODELS: The Harderian Gland data of Alpen et al.[1-3] was re-analyzed [4] using non-linear least square regression. The data set measured the induction of Harderian gland tumors in mice by high-energy protons, helium, neon, iron, niobium and lanthanum with LET s ranging from 0.4 to 950 keV/micron. We were able to strengthen the individual ion models by combining data for all ions into a model that relates both radiation dose and LET for the ion to tumor prevalence. We compared models based on Targeted Effects (TE) to one motivated by Non-targeted Effects (NTE) that included a bystander term that increased tumor induction at low doses non-linearly. When comparing fitted models to the experimental data, we considered the adjusted R2, the Akaike Information Criteria (AIC), and the Bayesian Information Criteria (BIC) to test for Goodness of fit.In the adjusted R2test, the model with the highest R2values provides a better fit to the available data. In the AIC and BIC tests, the model with the smaller values of the summary value provides the better fit. The non-linear NTE models fit the combined data better than the TE models that are linear at low doses. We evaluated the differences in the relative biological effectiveness (RBE) and found the NTE model provides a higher RBE at low dose compared to the TE model. POWER ANALYSIS: The final NTE model estimates were used to simulate example data to consider the design of new experiments to detect NTE at low dose for validation. Power and sample sizes were calculated for a variety of radiation qualities including some not considered in the Harderian Gland data set and with different background tumor incidences. We considered different experimental designs with varying number of doses and varying low doses dependant on the LET of the radiation. The optimal design to detect a NTE for an individual ion had 4 doses equally spaced below a maximal dose where bending due to cell sterilization was < 2%. For example at 100 keV/micron we would irradiate at 0.03 Gy, 0.065 Gy, 0.13 Gy, and 0.26 Gy and require 850 mice including a control dose for a sensitivity to detect NTE with 80% power. Sample sizes could be improved by combining ions similar to the methods used with the Harderian Gland data.

Chappelli, Lori J.↗

Cancer Risk Map for the Surface of Mars

We discuss calculations of the median and 95th percentile cancer risks on the surface of Mars for different solar conditions. The NASA Space Radiation Cancer Risk 2010 model is used to estimate gender and age specific cancer incidence and mortality risks for astronauts exploring Mars. Organ specific fluence spectra and doses for large solar particle events (SPE) and galactic cosmic rays (GCR) at various levels of solar activity are simulated using the HZETRN/QMSFRG computer code, and the 2010 version of the Badhwar and O Neill GCR model. The NASA JSC propensity model of SPE fluence and occurrence is used to consider upper bounds on SPE fluence for increasing mission lengths. In the transport of particles through the Mars atmosphere, a vertical distribution of Mars atmospheric thickness is calculated from the temperature and pressure data of Mars Global Surveyor, and the directional cosine distribution is implemented to describe the spherically distributed atmospheric distance along the slant path at each elevation on Mars. The resultant directional shielding by Mars atmosphere at each elevation is coupled with vehicle and body shielding for organ dose estimates. Astronaut cancer risks are mapped on the global topography of Mars, which was measured by the Mars Orbiter Laser Altimeter. Variation of cancer risk on the surface of Mars is due to a 16-km elevation range, and the large difference is obtained between the Tharsis Montes (Ascraeus, Pavonis, and Arsia) and the Hellas impact basin. Cancer incidence risks are found to be about 2-fold higher than mortality risks with a disproportionate increase in skin and thyroid cancers for all astronauts and breast cancer risk for female astronauts. The number of safe days on Mars to be below radiation limits at the 95th percent confidence level is reported for several Mission design scenarios.

Kim, Myung-Hee Y.↗

Radiation Dose Testing on Juno High Voltage Cables

The Juno mission to Jupiter will have a highly elliptical orbit taking the spacecraft through the radiation belts surrounding the planet. During these passes through the radiation belts, the spacecraft will be subject to high doses of radiation from energetic electrons and protons with energies ranging from 10 keV to 1 GeV. While shielding within the spacecraft main body will reduce the total absorbed dose to much of the spacecraft electronics, instruments and cables on the outside of the spacecraft will receive much higher levels of absorbed dose. In order to estimate the amount of degradation to two such cables, testing has been performed on two coaxial cables intended to provide high voltages to three of the instruments on Juno. Both cables were placed in a vacuum of 5x10(exp -6) torr and cooled to -50(deg)C prior to exposure to the radiation sources. Measurements of the coaxial capacitance per unit length and partial discharge noise floor indicate that increasing levels of radiation make measurable but acceptably small changes to the F EP Teflon utilized in the construction of these cables. In addition to the radiation dose testing, observations were made on the internal electrostatic charging characteristics of these cables and multiple discharges were recorded.

partial discharge↗

Evaluations of Risks from the Lunar and Mars Radiation Environments

Protecting astronauts from the space radiation environments requires accurate projections of radiation in future space missions. Characterization of the ionizing radiation environment is challenging because the interplanetary plasma and radiation fields are modulated by solar disturbances and the radiation doses received by astronauts in interplanetary space are likewise influenced. The galactic cosmic radiation (GCR) flux for the next solar cycle was estimated as a function of interplanetary deceleration potential, which has been derived from GCR flux and Climax neutron monitor rate measurements over the last 4 decades. For the chaotic nature of solar particle event (SPE) occurrence, the mean frequency of SPE at any given proton fluence threshold during a defined mission duration was obtained from a Poisson process model using proton fluence measurements of SPEs during the past 5 solar cycles (19-23). Analytic energy spectra of 34 historically large SPEs were constructed over broad energy ranges extending to GeV. Using an integrated space radiation model (which includes the transport codes HZETRN [1] and BRYNTRN [2], and the quantum nuclear interaction model QMSFRG[3]), the propagation and interaction properties of the energetic nucleons through various media were predicted. Risk assessment from GCR and SPE was evaluated at the specific organs inside a typical spacecraft using CAM [4] model. The representative risk level at each event size and their standard deviation were obtained from the analysis of 34 SPEs. Risks from different event sizes and their frequency of occurrences in a specified mission period were evaluated for the concern of acute health effects especially during extra-vehicular activities (EVA). The results will be useful for the development of an integrated strategy of optimizing radiation protection on the lunar and Mars missions. Keywords: Space Radiation Environments; Galactic Cosmic Radiation; Solar Particle Event; Radiation Risk; Risk Analysis; Radiation Protection.

Kim, Myung-Hee↗

Development of TID Hardness Assurance Methodologies to Capitalize on Statistical Radiation Environment Models

We develop methods for bounding part-to-part variation in TID data. When used in conjunction with statistical radiation environment models, these methods allow development of RHA that deliver estimated piece part reliability for any desired confidence level, moving beyond risk avoidance methodologies based on radiation design margin. Two methods are developed, and their results compared for realistic data.

Total Ionizing Dose↗

Development of TID Hardness Assurance Methodologies to Capitalize on Statistical Radiation Environment Models

We develop methods for bounding part-to-part variation in TID data. When used in conjunction with statistical radiation environment models, these methods allow development of RHA that deliver estimated piece part reliability for any desired confidence level, moving beyond risk avoidance methodologies based on radiation design margin. Two methods are developed, and their results compared for realistic data.

Total ionizing dose↗

The JPL Neptune Radiation Model (NMOD)

The objective of this study is the development of a comprehensive radiation model of the Neptunian environment for JPL mission planning. The ultimate goal is to provide a description of the high-energy electron and proton environments and the magnetic field at Neptune that can be used for engineering design. The JPL Neptune Radiation Model (NMOD) models the high-energy electrons and protons between 0.025 MeV and 5 MeV based on the California Institute of Technology's Cosmic Ray Subsystem and the Applied Physics Laboratory's Low Energy Charged Particle Detector on Voyager 2. As in previous JPL radiation models, the form of the Neptunian model is based on magnetic field coordinates and requires a conversion from spacecraft coordinates to Neptunian-centered magnetic "B-L" coordinates. Two types of magnetic field models have been developed for Neptune: 1) simple "offset, tilted dipoles" (OTD), and 2) a complex, multi-pole expansion model ("O8"). A review of the existing data on Neptune and a search of the NASA Planetary Data System (PDS) were completed to obtain the most current descriptions of the Neptunian high-energy particle environment. These data were fit in terms of the O8 B-L coordinates to develop the electron and proton flux models. The flux predictions of the new model were used to estimate the total ionizing dose (TID) rate along the Neptunian equator, meridional flux contours for the electrons and protons, and for flux and dose comparisons with the other radiation belts in the Solar System.

Garrett, Henry↗

The JPL Neptune Radiation Model (NMOD)

The objective of this study is the development of a comprehensive radiation model of the Neptunian environment for JPL mission planning. The ultimate goal is to provide a description of the high-energy electron and proton environments and the magnetic field at Neptune that can be used for engineering design. The JPL Neptune Radiation Model (NMOD) models the high-energy electrons and protons between 0.025 MeV and 5 MeV based on the California Institute of Technology's Cosmic Ray Subsystem and the Applied Physics Laboratory's Low Energy Charged Particle Detector on Voyager 2. As in previous JPL radiation models, the form of the Neptunian model is based on magnetic field coordinates and requires a conversion from spacecraft coordinates to Neptunian-centered magnetic "B-L" coordinates. Two types of magnetic field models have been developed for Neptune: 1) simple "offset, tilted dipoles" (OTD), and 2) a complex, multi-pole expansion model ("O8"). A review of the existing data on Neptune and a search of the NASA Planetary Data System (PDS) were completed to obtain the most current descriptions of the Neptunian high-energy particle environment. These data were fit in terms of the O8 B-L coordinates to develop the electron and proton flux models. The flux predictions of the new model were used to estimate the total ionizing dose (TID) rate along the Neptunian equator, meridional flux contours for the electrons and protons, and for flux and dose comparisons with the other radiation belts in the Solar System.

magnetic field↗

Charged particle radiation environment for the Spacelab and other missions in low earth orbit, revision A

The physical charged particle dose to be encountered in low earth orbit Spacelab missions is estimated for orbits of inclinations from e8.5 to 90 deg and altitudes from 200 to 800 km. The dose encountered is strongly altitude dependent, with a weaker dependence on inclination. Doses range from 0.007 rads/day at 28.5 deg and 200 km to 1.57 rads/day at 28.5 deg and 800 km behind a 5.0 g/sq cm shield. Geomagnetically trapped protons were the primary source of damage over most of the range of altitudes and inclinations, with galactic cosmic rays making a significant contribution at the lowest altitudes.

Watts, J. W., Jr.↗

A Photo-Realistic 3-D Mapping System for Extreme Nuclear Environments: Chornobyl

We present a novel stereoscopic mapping system for use in nuclear accident settings. First we discuss a radiation shielded sensor array desigtned to tolerate 10(sup 6)R of cumulative dose. Next we give procedures to ensure timely, accurate range estimation using trinocular stereo. Finally, we review the implementation of a system for the integration of range information into a 3-D, textured, metrically accurate surface mesh.

3-D mapping Chornobyl robot Pioneer robot Pioneer ↗

MIRACAL: A mission radiation calculation program for analysis of lunar and interplanetary missions

A computational procedure and data base are developed for manned space exploration missions for which estimates are made for the energetic particle fluences encountered and the resulting dose equivalent incurred. The data base includes the following options: statistical or continuum model for ordinary solar proton events, selection of up to six large proton flare spectra, and galactic cosmic ray fluxes for elemental nuclei of charge numbers 1 through 92. The program requires an input trajectory definition information and specifications of optional parameters, which include desired spectral data and nominal shield thickness. The procedure may be implemented as an independent program or as a subroutine in trajectory codes. This code should be most useful in mission optimization and selection studies for which radiation exposure is of special importance.

Nealy, John E.↗

Description, analysis and impact of major solar activity during recent U.S. Shuttle missions

Since STS-26, three large solar events have occurred during Shuttle missions: a geomagnetic storm during STS-29 and solar particle events (SPEs) during STS-28 and -34. The maximum dose to a crew attributed to an SPE was estimated to be 30 micro-Gy. Time-resolved dosimetry measurements of the SPE dose during STS-28 were made using the USAF Radiation Monitoring Equipment. Comparison of calculated and measured dose demonstrated a discrepancy, possibly a result of deficiencies in the geomagnetic cutoff model used. This experience demonstrates that dose from an SPE is strongly dependent on numerous factors such as orbit inclination, SPE start time, spectral parameters and geomagnetic field conditions; the exact combination of these factors is fortuitous. New sources of data and procedures are being investigated, including real-time tracking of auroral oval positions or determination of particle cutoff latitudes, for incorporation into operational Shuttle radiation support practices.

Golightly, M. J.↗