Overview of the Acoustic Testing of the European Service Module Structural Test Article (E-STA)

The European Space Agency (ESA) and their prime contractor Airbus Defense Space (ADS) are developing the European Service Module (ESM) for integration and utilization with other modules of NASAs Orion Multi-Purpose Crew Vehicle. As part of this development, ESA, ADS, NASA and the Lockheed Martin Company performed a series of reverberant acoustic tests in April-May 2016 on the ESM Structural Test Article (E-STA), the mechanical mock-up of the ESM designated for mechanical tests. Testing the E-STA under acoustic qualification loads verifies whether it can successfully withstand the medium and high frequency mechanical environment occurring during the vehicles lift-off and atmospheric phases of flight. The testing occurred at the Reverberant Acoustic Test Facility (RATF) at the NASA Glenn Research Centers Plum Brook Station site in Sandusky, OH, USA. This highly successful acoustic test campaign excited the E-STA to acoustic test levels as high as 149.4 dB Overall Sound Pressure Level. This acoustic testing met all the ESA and ADSs test objectives, including establishingverifying the random vibration qualification test levels for numerous hardware components of the ESM, and qualifying the ESMs Solar Array Wing electrical power system. This paper will address the test objectives, the test articles configuration, the test instrumentation and excitation levels, the RATF site and capabilities, the series of acoustic tests performed, and the technical issues faced and overcome to result in a successful acoustic test campaign for the ESM. A discussion of several test results is also included.

Testing↗

Overview of the Acoustic Testing of the European Service Module Structural Test Article (E-STA)

The European Space Agency (ESA) and their prime contractor Airbus Defense Space (ADS) are developing the European Service Module (ESM) for integration and utilization with other modules of NASAs Orion Multi-Purpose Crew Vehicle. As part of this development, ESA, ADS, NASA and the Lockheed Martin Company performed a series of reverberant acoustic tests in April-May 2016 on the ESM Structural Test Article (E-STA), the mechanical mock-up of the ESM designated for mechanical tests. Testing the E-STA under acoustic qualification loads verifies whether it can successfully withstand the medium and high frequency mechanical environment occurring during the vehicles lift-off and atmospheric phases of flight. The testing occurred at the Reverberant Acoustic Test Facility (RATF) at the NASA Glenn Research Centers Plum Brook Station site in Sandusky, OH, USA. This highly successful acoustic test campaign excited the E-STA to acoustic test levels as high as 149.4 dB Overall Sound Pressure Level. This acoustic testing met all the ESA and ADSs test objectives, including establishingverifying the random vibration qualification test levels for numerous hardware components of the ESM, and qualifying the ESMs Solar Array Wing electrical power system. This paper will address the test objectives, the test articles configuration, the test instrumentation and excitation levels, the RATF site and capabilities, the series of acoustic tests performed, and the technical issues faced and overcome to result in a successful acoustic test campaign for the ESM. A discussion of several test results is also included.

Qualification↗

Modal Testing of Seven Shuttle Cargo Elements for Space Station

From December 1996 to May 2001, the Modal and Control Dynamics Team at NASA's Marshall Space Flight Center (MSFC) conducted modal tests on seven large elements of the International Space Station. Each of these elements has been or will be launched as a Space Shuttle payload for transport to the International Space Station (ISS). Like other Shuttle payloads, modal testing of these elements was required for verification of the finite element models used in coupled loads analyses for launch and landing. The seven modal tests included three modules - Node, Laboratory, and Airlock, and four truss segments - P6, P3/P4, S1/P1, and P5. Each element was installed and tested in the Shuttle Payload Modal Test Bed at MSFC. This unique facility can accommodate any Shuttle cargo element for modal test qualification. Flexure assemblies were utilized at each Shuttle-to-payload interface to simulate a constrained boundary in the load carrying degrees of freedom. For each element, multiple-input, multiple-output burst random modal testing was the primary approach with controlled input sine sweeps for linearity assessments. The accelerometer channel counts ranged from 252 channels to 1251 channels. An overview of these tests, as well as some lessons learned, will be provided in this paper.

Kappus, Kathy O.↗

Orion MPCV Service Module Avionics Ring Pallet Testing, Correlation, and Analysis

The NASA Orion Multi-Purpose Crew Vehicle (MPCV) is being designed to replace the Space Shuttle as the main manned spacecraft for the agency. Based on the predicted environments in the Service Module avionics ring, an isolation system was deemed necessary to protect the avionics packages carried by the spacecraft. Impact, sinusoidal, and random vibration testing were conducted on a prototype Orion Service Module avionics pallet in March 2010 at the NASA Glenn Research Center Structural Dynamics Laboratory (SDL). The pallet design utilized wire rope isolators to reduce the vibration levels seen by the avionics packages. The current pallet design utilizes the same wire rope isolators (M6-120-10) that were tested in March 2010. In an effort to save cost and schedule, the Finite Element Models of the prototype pallet tested in March 2010 were correlated. Frequency Response Function (FRF) comparisons, mode shape and frequency were all part of the correlation process. The non-linear behavior and the modeling the wire rope isolators proved to be the most difficult part of the correlation process. The correlated models of the wire rope isolators were taken from the prototype design and integrated into the current design for future frequency response analysis and component environment specification.

Staab, Lucas↗

Dynamic Capability of an Operating Stirling Convertor

The NASA John H. Glenn Research Center and the US Department of Energy are currently developing a Stirling convertor for use as an advanced spacecraft power system for future NASA deep-space missions. NASA Headquarters has recently identified the Stirling technology generator for potential use as the spacecraft power system for two of NASA's new missions, the Europa Orbiter and the Solar Probe missions (planned for launch in 2006 and 2007 respectively). As part of the development of this power system, a Stirling Technology Demonstration Convertor was vibration tested at NASA John H. Glenn Research Center to verify its survivability and capability of withstanding the harsh dynamic environment typically seen by the spacecraft when it is launched by an expendable launch vehicle. The Technology Demonstration Convertor was fully operational (producing power) during the random vibration testing. The output power of the convertor and other convertor performance indicators were measured during the testing, and these results are discussed in this paper. Numerous accelerometers and force gauges also were used to provide information on the dynamic characteristics of the Technology Demonstration Convertor and as an indication of any possible damage due to the vibration. These measurements will also be discussed in this paper. The vibration testing of the Stirling Technology Demonstration Convertor was extremely successful. The Technology Demonstration Convertor survived all its vibration testing with no structural damage or functional performance degradation. As a result of this testing, the Stirling convertor's capability to withstand vibration has been demonstrated, enabling its usage in future spacecraft power systems.

Goodnight, Thomas W.↗

Vibration Testing of Electrical Cables to Quantify Loads at Tie-Down Locations

The standard method for defining static equivalent structural load factors for components is based on Mile s equation. Unless test data is available, 5% critical damping is assumed for all components when calculating loads. Application of this method to electrical cable tie-down hardware often results in high loads, which often exceed the capability of typical tie-down options such as cable ties and P-clamps. Random vibration testing of electrical cables was used to better understand the factors that influence component loads: natural frequency, damping, and mass participation. An initial round of vibration testing successfully identified variables of interest, checked out the test fixture and instrumentation, and provided justification for removing some conservatism in the standard method. Additional testing is planned that will include a larger range of cable sizes for the most significant contributors to load as variables to further refine loads at cable tie-down points. Completed testing has provided justification to reduce loads at cable tie-downs by 45% with additional refinement based on measured cable natural frequencies.

Dutson, Joseph D.↗

Effects of Mild Hypobaric Hypoxia on Response From Mild Exercise in NASA Exploration Atmosphere Tests

INTRODUCTION: The NASA Exploration Atmosphere study aims to validate a new prebreathe protocol incorporating an alternate habitat atmosphere of 56.5 kPa (8.2psia), 34% O 2 , and 66% N 2 to control and mitigate decompression sickness risk associated with spaceflight extravehicular activities. This alternate atmosphere results in a mild hypoxic environment (PIO 2 of 128 mmHg) that may influence inhabitant physiological responses to exercise. Therefore, the responses to light exercise in relation to the mild hypobaric hypoxic environment were investigated. METHODS: Eight participants (4M/4F; age=38.3±9.0 yr; weight=76.0±13.1 kg; peak aerobic capacity [VO 2 pk]= 3.1±0.7 L/min) were exposed to a mild hypobaric hypoxic environment for 11 days in NASA’s 20-foot hypobaric chamber at Johnson Space Center. Participants alternated test days between a habitat atmosphere of 56.5 kPA/34% O 2 and simulated 6-hour EVA environment, 29.6 kPa/85% O 2 . Participants completed pre-mission graded VO 2 pk tests on a LODE cycle ergometer with ParvoMedics metabolic analyzer. Submaximal aerobic tests were performed pre and during the mission (10-minutes of exercise at a workload of 40% VO 2 pk).Pre-mission, performed submaximal exercise exposed to a breathing air mixture of, 18% O 2 and balance N 2 , to simulate the mildly hypoxic environment within the 20-foot chamber. Linear mixed models (fixed effect: test day; random effects: subject, age) were performed to determine whether physiological responses (oxygen uptake [VO 2 ], carbon dioxide production [VCO 2 ], ventilation [VE], oxygen saturation [SPO 2 ], heart rate [HR], respiratory exchange ratio [RER]) to submaximal exercise performed within the 20-foot hypobaric chamber every 2 days differed from the pre-mission (18% O 2 ) testing. Results are presented as estimated marginal means with lower and upper confidence limits, with significance set to 0.05. RESULTS AND DISCUSSION: Seven of eight participants completed the chamber study. Mixed models for VO 2 , VCO 2 , SpO 2 , HR, and RER indicated negligible impact of the mild hypoxic chamber environment compared to pre-mission testing (all p>0.05).Results for VE indicated a minor impact of chamber environment compared to pre-mission testing (37.0 L/min [30.8, 43.2]), with increased VE at test day 10 (40.4 L/min [34.2, 46.6]; p= 0.029).The aerobic performance data collected suggests limited physiologic responses to mild exercise when performed at normobaric hypoxia and hypobaric hypoxia.

B Siders↗

Study of Dynamic Characteristics of Aeroelastic Systems Utilizing Randomdec Signatures

The feasibility of utilizing the random decrement method in conjunction with a signature analysis procedure to determine the dynamic characteristics of an aeroelastic system for the purpose of on-line prediction of potential on-set of flutter was examined. Digital computer programs were developed to simulate sampled response signals of a two-mode aeroelastic system. Simulated response data were used to test the random decrement method. A special curve-fit approach was developed for analyzing the resulting signatures. A number of numerical 'experiments' were conducted on the combined processes. The method is capable of determining frequency and damping values accurately from randomdec signatures of carefully selected lengths.

Chang, C. S.↗

Supporting Development for the Stirling Radioisotope Generator and Advanced Stirling Technology Development at NASA Glenn Research Center

A high-efficiency, 110-We (watts electric) Stirling Radioisotope Generator (SRG110) for possible use on future NASA Space Science missions is being developed by the Department of Energy, Lockheed Martin, Stirling Technology Company (STC), and NASA Glenn Research Center (GRC). Potential mission use includes providing spacecraft onboard electric power for deep space missions and power for unmanned Mars rovers. GRC is conducting an in-house supporting technology project to assist in SRG110 development. One-, three-, and six-month heater head structural benchmark tests have been completed in support of a heater head life assessment. Testing is underway to evaluate the key epoxy bond of the permanent magnets to the linear alternator stator lamination stack. GRC has completed over 10,000 hours of extended duration testing of the Stirling convertors for the SRG110, and a three-year test of two Stirling convertors in a thermal vacuum environment will be starting shortly. GRC is also developing advanced technology for Stirling convertors, aimed at substantially improving the specific power and efficiency of the convertor and the overall generator. Sunpower, Inc. has begun the development of a lightweight Stirling convertor, under a NASA Research Announcement (NRA) award, that has the potential to double the system specific power to about 8 We/kg. GRC has performed random vibration testing of a lower-power version of this convertor to evaluate robustness for surviving launch vibrations. STC has also completed the initial design of a lightweight convertor. Status of the development of a multi-dimensional computational fluid dynamics code and high-temperature materials work on advanced superalloys, refractory metal alloys, and ceramics are also discussed.

Thieme, Lanny G.↗

Supporting Development for the Stirling Radioisotope Generator and Advanced Stirling Technology Development at NASA Glenn

A high-efficiency, 110-W(sub e) (watts electric) Stirling Radioisotope Generator (SRG110) for possible use on future NASA Space Science missions is being developed by the Department of Energy, Lockheed Martin, Stirling Technology Company (STC), and NASA Glenn Research Center (GRC). Potential mission use includes providing spacecraft onboard electric power for deep space missions and power for unmanned Mars rovers. GRC is conducting an in-house supporting technology project to assist in SRG110 development. One-, three-, and six-month heater head structural benchmark tests have been completed in support of a heater head life assessment. Testing is underway to evaluate the key epoxy bond of the permanent magnets to the linear alternator stator lamination stack. GRC has completed over 10,000 hours of extended duration testing of the Stirling convertors for the SRG110, and a three-year test of two Stirling convertors in a thermal vacuum environment will be starting shortly. GRC is also developing advanced technology for Stirling convertors, aimed at substantially improving the specific power and efficiency of the convertor and the overall generator. Sunpower, Inc. has begun the development of a lightweight Stirling convertor, under a NASA Research Announcement (NRA) award, that has the potential to double the system specific power to about 8 W(sub e) per kilogram. GRC has performed random vibration testing of a lowerpower version of this convertor to evaluate robustness for surviving launch vibrations. STC has also completed the initial design of a lightweight convertor. Status of the development of a multi-dimensional computational fluid dynamics code and high-temperature materials work on advanced superalloys, refractory metal alloys, and ceramics are also discussed.

Thieme, Lanny G.↗

Characterization Testing of Lockheed Martin Micro1-2 Cryocoolers Optimized for 220 K Environment

The Mapping Imaging Spectrometer for Europa (MISE) Instrument on the Europa Clipper mission has baselined a Lockheed Martin high-power Micro1-2 pulse tube cryocooler operating at 135 Hz with a 220 K heat rejection temperature. This paper describes the testing and results of two Lockheed Martin Micro1-2 coolers optimized for these conditions. The thermal performance of the microcoolers was measured in vacuum for heat reject temperatures between 220 and 230 K. The coolers were operated with input powers ranging from 5 W to 40 W and drive frequency between 125 Hz and 145 Hz. The optimal drive frequency was strongly dependent on heat reject temperature. In addition, the exported forces and torques of the coolers were measured at 300 K heat rejection for input powers ranging from 5 W to 60 W and drive frequency between 120 Hz and 160 Hz. The exported forces were dependent on both piston amplitude and drive frequency. Moreover, the following were measured on one of the coolers: DC and AC magnetic fields at various locations, the off-state conductance of the pulse tube, and the effect of inclination angle of the pulse tube relative to gravity on the performance of the cooler. Finally, one of the coolers was subjected to random vibration testing.

Rodriguez, J.I.↗

Thermal advection and stratification effects on surface winds and the low level meridional mass transport

Statistical tests are performed on the Seasat scatterometer observations to examine if and to what degree thermal advection and stratification effects manifest themselves in these remotely sensed measurements of mean wind and wind stress over the ocean. On the basis of a two layer baroclinic boundary layer model which is presented, it is shown that the thermal advection and stratification of the entire boundary layer as well as the geostrophic forcing influence the modeled near surface wind and wind stress profiles. Evidence of diurnal variation in the stratification under barotropic conditions is found in the data, with the daytime marine boundary layer being more convective than its nighttime counterpart. The temporal and spacial sampling pattern of the satellite makes it impossible to recover the full diurnal cycle, however. The observed effects of the thermal advection are shown to be statistically significant during the day (and presumed more convective) hours, causing a systematic increase in the poleward transport of mass and heat. The statistical results are in a qualitative agreement with the model simulations and cannot be reproduced in randomized control tests.

Levy, Gad↗

Using Dynamic Sensitivity Analysis to Assess Testability

This paper discusses sensitivity analysis and its relationship to random black box testing. Sensitivity analysis estimates the impact that a programming fault at a particular location would have on the program's input/output behavior. Locations that are relatively \"insensitive" to faults can render random black box testing unlikely to uncover programming faults. Therefore, sensitivity analysis gives new insight when interpreting random black box testing results. Although sensitivity analysis is computationally intensive, it requires no oracle and no human intervention.

Voas, Jeffrey↗

Investigating performance and variability of NIF ICF experiments with deep learning

The parameter space involved in designing an inertial confinement fusion shot at the National Ignition Facility (NIF) is massively multi-dimensional and the cost of a single shot makes a comprehensive set of sensitivity studies in the laboratory impractical. The use of machine learning to overcome these challenges has gained popularity and has had several successful applications by the scientific community. We extend on these efforts by training a neural network (NN) on information about the experimental design, engineering elements, and drive asymmetry to predict with uncertainty the neutron yield of an experiment. We find the measured and model predicted values are in good agreement, with an R 2 value of 0.91 for a randomly selected test dataset. Almost all the predicted 95% credible intervals contain the corresponding measured value for both training and test datasets. We identify correlations picked up by the NN between the shot design, yield, and variability and use them to motivate shot sensitivity studies. The first shot to exceed the Lawson-like ignition criteria (N210808) was conducted at the NIF and subsequent shots studied the design’s robustness. In a follow-up shot to N210808, our model predicts capsule quality to be the main performance degradation mechanism that prevented the shot from repeating previous performance levels. Shot N221204 was the first shot to exceed a target energy gain of 1. Our model predicts increased yield with reduced coast time for a N221204 study and greater variability for designs with lower peak powers at constant yield. The model’s fast prediction speed and uncertainty prediction are useful for identifying interesting design paths that could warrant further investigation with conventional simulations to search for robust high yield designs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of theory with the experimental characterization of the spatial frequency response of interferometers using a binary pseudo-random array sample

Experimental evaluations of the surface height response of an interference microscope using a binary pseudo-random array test sample are compared with a theory based on a Fourier optics model. Measurements of key instrument characteristics, including the illumination, imaging, and obscuring apertures of three different Mirau objectives, support the theoretical calculations. Agreement between experimental and theoretical modeling confirms the predictability of the spatial frequency response for the purpose of specification and optimization of instrument configuration for specific metrology tasks. The results also provide confidence in methods of compensating for the decrease in instrument response with spatial frequency.

Calibration↗

Detection of faults and software reliability analysis

Multi-version or N-version programming is proposed as a method of providing fault tolerance in software. The approach requires the separate, independent preparation of multiple versions of a piece of software for some application. These versions are executed in parallel in the application environment; each receives identical inputs and each produces its version of the required outputs. The outputs are collected by a voter and, in principle, they should all be the same. In practice there may be some disagreement. If this occurs, the results of the majority are taken to be the correct output, and that is the output used by the system. A total of 27 programs were produced. Each of these programs was then subjected to one million randomly-generated test cases. The experiment yielded a number of programs containing faults that are useful for general studies of software reliability as well as studies of N-version programming. Fault tolerance through data diversity and analytic models of comparison testing are discussed.

Knight, John C.↗

Random vibration (stress screening) of printed wiring assemblies

The results of a random vibration test screening (RVSS) study of the determination of the upper and lower vibration limits on printed wiring assemblies (PWA) are summarized. The study results are intended to serve as a guide for engineers and designers who make decisions on PWA features that need to withstand the stresses of dynamic testing and screening. The maximum allowable PWA deflection, G levels, and PSD levels are compared to the expected or actual levels to determine if deleterious effects will occur.

Bastien, Gilbert J.↗