Search NASA⌕ Search

SEARCH · Search NASA

Results for “rapid detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Coordinating an Autonomous Earth-Observing Sensorweb

A system of software has been developed to coordinate the operation of an autonomous Earth-observing sensorweb. Sensorwebs are collections of sensor units scattered over large regions to gather data on spatial and temporal patterns of physical, chemical, or biological phenomena in those regions. Each sensor unit is a node in a data-gathering/ data-communication network that spans a region of interest. In this case, the region is the entire Earth, and the sensorweb includes multiple terrestrial and spaceborne sensor units. In addition to acquiring data for scientific study, the sensorweb is required to give timely notice of volcanic eruptions, floods, and other hazardous natural events. In keeping with the inherently modular nature of the sensory, communication, and data-processing hardware, the software features a flexible, modular architecture that facilitates expansion of the network, customization of conditions that trigger alarms of hazardous natural events, and customization of responses to alarms. The soft8 NASA Tech Briefs, July 2006 ware facilitates access to multiple sources of data on an event of scientific interest, enables coordinated use of multiple sensors in rapid reaction to detection of an event, and facilitates the tracking of spacecraft operations, including tracking of the acquisition, processing, and downlinking of requested data.

Sherwood, Robert↗

Challenges of NDE Simulation Tool Challenges of NDE Simulation Tool

Realistic nondestructive evaluation (NDE) simulation tools enable inspection optimization and predictions of inspectability for new aerospace materials and designs. NDE simulation tools may someday aid in the design and certification of advanced aerospace components; potentially shortening the time from material development to implementation by industry and government. Furthermore, modeling and simulation are expected to play a significant future role in validating the capabilities and limitations of guided wave based structural health monitoring (SHM) systems. The current state-of-the-art in ultrasonic NDE/SHM simulation cannot rapidly simulate damage detection techniques for large scale, complex geometry composite components/vehicles with realistic damage types. This paper discusses some of the challenges of model development and validation for composites, such as the level of realism and scale of simulation needed for NASA' applications. Ongoing model development work is described along with examples of model validation studies. The paper will also discuss examples of the use of simulation tools at NASA to develop new damage characterization methods, and associated challenges of validating those methods.

Leckey, Cara A. C.↗

Increased Greenland Melt Triggered by Large-Scale, Year-Round Cyclonic Moisture Intrusions

Surface melting is a major driver of Greenland's mass loss. Yet, the mechanisms that trigger melt are still insufficiently understood because seasonally based studies blend processes initiating melt with positive feedbacks. Here, we focus on the triggers of melt by examining the synoptic atmospheric conditions associated with 313 rapid melt increases, detected in a satellite-derived melt extent product, equally distributed throughout the year over the period 1979-2012. By combining reanalysis and weather station data, we show that melt is initiated by a cyclone-driven, southerly flow of warm, moist air, which gives rise to large-scale precipitation. A decomposition of the synoptic atmospheric variability over Greenland suggests that the identified, melt-triggering weather pattern accounts for approximately 40 percent of the net precipitation, but increases in the frequency, duration and areal extent of the initiated melting have shifted the line between mass gain and mass loss as more melt and rainwater run off or accumulate in the snowpack. Using a regional climate model, we estimate that the initiated melting more than doubled over the investigated period, amounting to approximately 28 percent of the overall surface melt and revealing that, despite the involved mass gain, year-round precipitation events are participating in the ice sheet's decline.

Oltmanns, Marilena↗

Data acquisition and path selection decision making for an autonomous roving vehicle

Problems related to the guidance of an autonomous rover for unmanned planetary exploration were investigated. Topics included in these studies were: simulation on an interactive graphics computer system of the Rapid Estimation Technique for detection of discrete obstacles; incorporation of a simultaneous Bayesian estimate of states and inputs in the Rapid Estimation Scheme; development of methods for estimating actual laser rangefinder errors and their application to date provided by Jet Propulsion Laboratory; and modification of a path selection system simulation computer code for evaluation of a hazard detection system based on laser rangefinder data.

Frederick, D. K.↗

Application of cabin atmosphere monitors to rapid screening of breath samples for the early detection of disease states

Analysis of human breath is a nonintrusive method to monitor both endogenous and exogenous chemicals found in the body. Several technologies were investigated and developed which are applicable to monitoring some organic molecules important in both physiological and pathological states. Two methods were developed for enriching the organic molecules exhaled in the breath of humans. One device is based on a respiratory face mask fitted with a polyethylene foam wafer; while the other device is a cryogenic trap utilizing an organic solvent. Using laboratory workers as controls, two organic molecules which occurred in the enriched breath of all subjects were tentatively identified as lactic acid and contisol. Both of these substances occurred in breath in sufficient amounts that the conventional method of gas-liquid chromatography was adequate for detection and quantification. To detect and quantitate trace amounts of chemicals in breath, another type of technology was developed in which analysis was conducted using high pressure liquid chromatography and mass spectrometry.

Valentine, J. L.↗

Satellite Detection of Precipitation over the North Pacific

Intense extratropical winter cyclones often impact the West Coast of North America with strong winds and heavy precipitation. Several times during a winter season, short-term forecasts (24 - 48 hours) of these storms are seriously deficient with central pressure errors in the 10's of hPa and surface low position errors in the 100's of km. For example, 48-hr sea level pressure errors (forecast - observation) at buoy 46005 off the Oregon coast for the 2001 - 2002 winter season is plotted. In addition, two times the standard deviation (determined from pressure errors from the last four winter seasons) are also shown. It is evident from this figure that large forecast errors (i.e. greater than 10 hPa) occurred about 10 times this past winter at buoy 46005 with three events where the errors were 20 hPa. Beside large forecast errors of sea level pressure, numerical forecasts of precipitation for land falling cyclones can also be flawed. This is due in large part to the lack of accurate precipitation information over the ocean. Therefore, remote sensing techniques are the only viable option for obtaining accurate information on the distribution and intensity of precipitation over the North Pacific. Due to the radiative characteristics of precipitation sized hydrometeors at microwave frequencies, microwave sensors are able to detect precipitation over oceanic regions. Past studies have demonstrated the utility of passive microwave rainrate data for locating intense rainfall in rapidly deepening cyclones, in detecting developing polar mesocyclones and in determining frontal bands. There are currently many sources of microwave rainrate data: the Special Sensor Microwave Imager (SSM/I) (currently flying on three platforms), the Advanced Microwave Sounding Unit (AMSU-B) (currently flying on NOAA-15, NOAA-16, and NOAA-17), and the Tropical Rainfall Measuring Mission Microwave Imager (TMI). Data will soon be available from the Advanced Microwave Radiometer-EOS (AMSR-E) on the Aqua platform. In this paper, we present a new technique for mapping rainrate distributions over the North Pacific utilizing rainrate estimates from several microwave sensors and upper-tropospheric winds derived from geosynchronous satellite IR data. The goal of this work is to develop a way to obtain high temporal and spatial rainfall information over the North Pacific. This information will be used to support the verification of model derived precipitation distributions and to support the analysis of in situ measurements of rainfall during the Improvement of Microphysical Parameterization through Observational Verification Experiment (IMPROVE) field campaigns.

Smith, Jeremy↗

Detection of x ray sources in PROS

The problem of detecting discrete sources in x-ray images has much in common with the problem of automatic source detection at other wavelengths. In all cases, one searches for positive brightness enhancements exceeding a certain threshold, which appear consistent with what one expects for a point source, in the presence of a (possibly) spatially variable background. Multidimensional point spread functions (e.g., dependent on detector position and photon energy) are also common. At the same time, the problem in x-ray astronomy has some unique aspects. For example, for typical x-ray exposures in current or recent observatories, the number of available pixels far exceeds the number of actual x-ray events, so Poisson, rather than Gaussian statistics apply. Further, extended cosmic x-ray sources are common, and one often desires to detect point sources in the vicinity or even within bright, diffuse x-ray emission. Finally, support structures in x-ray detectors often cast sharp shadows in x-ray images making it necessary to detect sources in a region of rapidly varying exposure. We have developed a source detection package within the IRAF/PROS environment which attempts to deal with some of the problems of x-ray source detection. We have patterned our package after the successful Einstein Observatory x-ray source detection programs. However, we have attempted to improve the flexibility and accessibility of the functions and to provide a graphical front-end for the user. Our philosophy has been to use standard IRAF tasks whenever possible for image manipulation and to separate general functions from mission-specific ones. We will report on the current status of the package and discuss future developments, including simulation tasks, to allow the user to assess detection efficiency and source significance, tasks to determine source intensity, and alternative detection algorithms.

Deponte, J.↗

CyanoSCape: Freshwater Phytoplankton and Floating Aquatic Vegetation Biodiversity

In Southern Africa, the impacts of anthropogenic activities on biodiversity and ecosystem services are exacerbated by the climate crisis. Rapid land use change and the lack of emphasis on environmentally sustainable agricultural practices has hindered hydrological processes and compromised riverine and aquatic ecosystems. This poses obvious risks to natural/indigenous aquatic biodiversity and long-term ecosystem sustainability. Phytoplankton serve as the foundation of the freshwater food web with zooplankton as consumers, which feed fish, invertebrates, and so on up the food chain that comprises the biodiversity of the freshwater system that serves as habitat for biodiversity as well. The diversity of phytoplankton (microscopic organisms) includes photosynthesizing bacteria (cyanobacteria), plant-like diatoms, dinoflagellates, and green algae. Nutrient run-off from agricultural fertilizers and urban overflows, warm temperatures, abundant light availability and compromised hydrological systems provide an ideal environment for cyanobacteria to flourish. Increased prevalence of cyanobacteria, due to both natural and anthropogenic causes, can incur significant effects on the biodiversity of the overall phytoplankton assemblage. These bloom forming algae can significantly outcompete other phytoplankton classes in warmer and eutrophic waters where they are quick to dominate the freshwater system. Eutrophication and toxic cyanobacteria blooms (cyanoHABs) in the inland waters of the Greater Cape Floristic Region (GCFR) incur significant effects on the biodiversity of the overall phytoplankton assemblage and provide a favorable environment forthe overgrowth of floating aquatic vegetation (FAV), which is often invasive and associated with reduced aquatic biodiversity. The algal biodiversity of the GCFR’s freshwater systems is not well characterized. Hyperspectral optical observations are expected to facilitate the improvement of current phytoplankton functional type retrievals significantly, as the sensitivity is sufficient that the distinctive, fine spectral features of different phytoplankton groups can be detected. This will enable testing emerging algorithms and inform the development of new algorithms for use with upcoming hyperspectral satellite missions in this decade. Innovations in optical sensor sensitivity and next generation machine learning capabilities considerably enhance the potential for accurate and rapid detection of phytoplankton, namely the presence, extent, and diversity of cyanobacteria present in cyanoHABs and additionally, invasive FAV. Upcoming hyperspectral satellite missions such as NASA’s Surface Biology and Geology (SBG), Plankton, Aerosol, Cloud, ocean Ecosystem (PACE), and the European Space Agency’s Copernicus Hyperspectral Imaging Mission (CHIME) will provide imagery with unprecedented spectral and spatial resolution which will further enable the discovery of linkages between the seasonality and dynamics of HABs and FAV. The overarching goal of this project is to utilize hyperspectral data, with recently developed and next-generation algorithms, to determine the biodiversity of freshwater systems phytoplankton assemblage with emphasis on genus level distinction, as well as monitor the prevalence and diversity of FAV.

CyanoSCape↗

NuSTAR Detection of High-Energy X-Ray Emission and Rapid Variability from Sagittarius A(star) Flares

Sagittarius A(star) harbors the supermassive black hole that lies at the dynamical center of our Galaxy. Sagittarius A(star) spends most of its time in a low luminosity emission state but flares frequently in the infrared and X-ray, increasing up to a few hundred fold in brightness for up to a few hours at a time. The physical processes giving rise to the X-ray flares are uncertain. Here we report the detection with the NuSTAR observatory in Summer and Fall 2012 of four low to medium amplitude X-ray flares to energies up to 79 keV. For the first time, we clearly see that the power-law spectrum of Sagittarius A(star) X-ray flares extends to high energy, with no evidence for a cut off. Although the photon index of the absorbed power-law fits are in agreement with past observations, we find a difference between the photon index of two of the flares (significant at the 95% confidence level). The spectra of the two brightest flares (approx. 55 times quiescence in the 2- 10 keV band) are compared to simple physical models in an attempt to identify the main X-ray emission mechanism, but the data do not allow us to significantly discriminate between them. However, we confirm the previous finding that the parameters obtained with synchrotron models are, for the X-ray emission, physically more reasonable than those obtained with inverse-Compton models. One flare exhibits large and rapid (less than 100 s) variability, which, considering the total energy radiated, constrains the location of the flaring region to be within approx. 10 Schwarzschild radii of the black hole.

NuSTAR detection of high-energy X-ray emission and↗

Keeping a Beat on the Heart

Feel the relief of a patient suffering from heart arrhythmia, who is able to return home while having her heart monitored by health professionals 24 hours a day, without the fear that she will miss an important indicator and suffer a fatal heart attack - using technology originally developed to conduct experiments on the Space Shuttle. Approximately 400,000 Americans die every year from sudden heart attacks . Medical research revealed that patterns of electrical activity in the heart can act as predictors of these lethal cardiac events known as arrhythmias. Fortunately, certain arrhythmias such as ventricular fibrillation (loss of regular heartbeat and subsequent loss of function) and ventricular tachycardia (rapid heartbeats), can be detected and appropriately treated. Today, patients at moderate risk of arrhythmias can benefit from technology that would permit long- term continuous monitoring of electrical cardiac rhythms outside the hospital environment in the comfort of their own homes. Medical telemetry systems, also known as telemedicine, are evolving rapidly as wireless communication technology advances, evidenced by the commercial products and research prototypes for remote health monitoring that have appeared in recent years. Wireless systems allow patients to move freely in their home and work environment while being monitored remotely by health care professionals.

Liszka, Kathy J.↗

Establishing and Monitoring an Aseptic Workspace for Building the MOMA Mass Spectrometer

Mars Organic Molecule Analyzer (MOMA) is an instrument suite on the ESA ExoMars 2018 Rover, and the Mass Spectrometer (MOMA-MS) is being built at Goddard Space Flight Center (GSFC). As MOMA-MS is a life-detection instrument and it thus falls in the most stringent category of Planetary Protection (PP) biological cleanliness requirements. Less than 0.03 sporem2 is allowed in the instrument sample path. In order to meet these PP requirements, MOMA-MS must be built and maintained in a low bioburden environment. The MOMA-MS project at GSFC maintains three cleanrooms with varying levels of bioburden control. The Aseptic Assembly Cleanroom has the highest level of control, applying three different bioburden reducing methods: 70 IPA, 7.5 Hydrogen Peroxide, and Ultra-Violet C light. The three methods are used in rotation and each kills microbes by a different mechanism, reducing the likelihood of microorganisms developing resistance to all three. The Integration and Mars Chamber Cleanrooms use less biocidal cleaning, with the option to deploy extra techniques as necessary. To support the monitoring of cleanrooms and verification that MOMA-MS hardware meets PP requirements, a new Planetary Protection lab was established that currently has the capabilities of standard growth assays for spore or vegetative bacteria, rapid bioburden analysis that detects Adenosine Triphosphate (ATP), plus autoclave and DHMR verification. The cleanrooms are monitored both for vegetative microorganisms and by rapid ATP assay, and a clear difference in bioburden is observed between the aseptic the other cleanroom.

Contamination Control Engineering↗

Establishing and Monitoring an Aseptic Workspace for Building the MOMA Mass Spectrometer

Mars Organic Molecule Analyzer (MOMA) is an instrument suite on the European Space Agency (ESA) ExoMars 2020 Rover, and the Mass Spectrometer (MOMA-MS) is being built at Goddard Space Flight Center (GSFC). MOMA-MS is a life-detection instrument and thus falls in the most stringent category of Planetary Protection (PP) biological cleanliness requirements. Less than 0.03 spore/m2 are allowed in the instrument sample path. In order to meet these PP requirements, MOMA-MS must be built and maintained in a low bioburden environment. The MOMA-MS project at GSFC maintains three clean rooms with varying levels of bioburden control. The Aseptic Assembly Clean room has the highest level of control, applying three different bioburden reducing methods: 70% Isopropyl Alcohol (IPA), 7.5% Hydrogen Peroxide, and Ultra-Violet C (UVC) light. The three methods are used in rotation and each kills microorganisms by a different mechanism, reducing the likelihood of microorganisms developing resistance to all three. The Integration and Mars Chamber Clean rooms use less biocidal cleaning, with the option to deploy extra techniques as necessary. To support the monitoring of clean rooms and verification that MOMA-MS hardware meets PP requirements, a new Planetary Protection lab was established that currently has the capabilities of standard growth assays for spore or vegetative bacteria, rapid bioburden analysis that detects Adenosine Triphosphate (ATP), plus autoclave and Dry Heat microbial Reduction (DHMR) verification. The clean rooms are monitored for vegetative microorganisms and by rapid ATP assay, and a clear difference in bioburden is observed between the aseptic and other clean room.

Contamination Control Engineering↗

Operational Use of the AIRS Total Column Ozone Retrievals Along with the RGB Air Mass Product as Part of the GOES-R Proving Ground

The National Oceanic and Atmospheric Administration (NOAA) National Centers for Environmental Prediction (NCEP) Hydrometeorological Prediction Center (HPC) and Ocean Prediction Center (OPC) provide short-term and medium-range forecast guidance of heavy precipitation, strong winds, and other features often associated with mid-latitude cyclones over both land and ocean. As a result, detection of factors that lead to rapid cyclogenesis and high wind events is key to improving forecast skill. One phenomenon that has been identified with these events is the stratospheric intrusion that occurs near tropopause folds. This allows for deep mixing near the top of the atmosphere where dry air high in ozone concentrations and potential vorticity descends (sometimes rapidly) deep into the mid-troposphere. Observations from satellites can aid in detection of these stratospheric air intrusions (SAI) regions. Specifically, multispectral composite imagery assign a variety of satellite spectral bands to the red, green, and blue (RGB) color components of imagery pixels and result in color combinations that can assist in the detection of dry stratospheric air associated with PV advection, which in turn may alert forecasters to the possibility of a rapidly strengthening storm system. Single channel or RGB satellite imagery lacks quantitative information about atmospheric moisture unless the sampled brightness temperatures or other data are converted to estimates of moisture via a retrieval process. Thus, complementary satellite observations are needed to capture a complete picture of a developing storm system. Here, total column ozone retrievals derived from a hyperspectral sounder are used to confirm the extent and magnitude of SAIs. Total ozone is a good proxy for defining locations and intensity of SAIs and has been used in studies evaluating that phenomenon (e.g. Tian et al. 2007, Knox and Schmidt 2005). Steep gradients in values of total ozone seen by satellites have been linked to stratosphere-troposphere exchange (WMO, 1985).

Folmer, Michael↗

Development of a Point of Care Technology for Military Medical Applications in Austere Environments

NASA, Lawrence Livermore National Laboratory (LLNL) and the Department of Defense (DoD) share a common interest in compact medical diagnostic technologies—also known as “point of care testing” (POCT) technologies. For NASA, the need is to take care of astronauts on deep space missions. For LLNL, the focus is on technologies needed to support homeland security applications. For DoD, the need is to support warfighters in military theaters of operation, especially for prolonged field care and en route care. A recently patented technology, “Portable Medical Diagnosis Instrument” (U.S. Patent 9824870), co-invented by NASA and LLNL, is being developed further in a partnership between NASA, LLNL and Travis Air Force Base, with a focus on military applications. This instrument, the NASA-LLNL Medical Tricorder, can be used for a wide range of clinical samples including breath, saliva and blood. One component of the Tricorder is the NASA E-Nose, a carbon nanotube-based chemical sensor, integrated into a hand-held smart phone, that can detect and measure “breath biomarkers” in the gas phase of exhaled breath. The response of the NASA E-Nose is rapid, which makes it possible to detect various gas-phase substances in real time. The NASA E-Nose, with modification, can also be used for breath condensate analysis. Another component of the Tricorder is a miniaturized microfluidic analyzer, under development by LLNL, that does not require any pumps. The microfluidic analyzer can detect and measure biomarkers in liquid samples, such as blood, saliva and breath condensate. This microfluidic system requires small quantities of liquid sample and can perform analysis very rapidly (seconds to minutes), which makes it possible to detect relevant biomarkers in near real time in the field. The Clinical Investigation Facility (CIF) at Travis Air Force Base is currently conducting research with the goal to develop improved field-able technologies and procedures for the emergency response to life threatening injuries soldiers may receive in theater. This work includes experimental large animal systems and comprehensive collection of clinical specimens and physiological data. NASA and LLNL are partnering with Travis to test and further develop the Tricorder technology for high priority military applications, initially focused on lung injury models and traumatic brain injury.

Loftus, David J.↗

Simulation of obstacle detection scheme for Mars terrain using minicomputer

Simulation for detection of obstacles on Martian terrain by a laser rangefinder mounted on an autonomous roving vehicle is achieved by a rapid estimation scheme on a computer with IDIIOM display. Near and far edges of pyramids and hemispherical craters or boulders can be recognized if the obstacles are more than about 15 m from the laser rangefinder and the noise standard deviation is less than about 10 cm. If these conditions are not met the rapid estimation scheme can still detect the top edge of a boulder and the near edge of a crater. The scheme is considered equivalent or better than an earlier (Reed, Sanyal, and Shen, 1974) four-directional Laplacian method, but requires slightly more computation.

Leung, K. L.↗

The architecture of the avian retina following exposure to chronic 2 G

Rhode Island Red female chicks at 2 weeks posthatch were subjected, for 7 d, to either earth gravity of 1 G or a 2-G hypergravity environment by chronic whole-body centrifugation. Animals were sacrificed at 3 weeks posthatch and the eyes were enucleated, fixed in 10% BNF, doubly embedded, sectioned at 7-8 microns and routinely processed with H & E for histological examination. Compared to normogravity controls, animal exposure for 1 week to the chronic effects of 2-G resulted in a significantly decreased mean width of the photoreceptor, inner nuclear, and inner plexiform retinal layers. The outer nuclear, outer plexiform, and ganglion cell layers of the retina appeared minimally affected by the hypergravity state since the mean width of these layers showed no noticeable differences from earth gravity control animals. The present anatomic findings suggest a reduction in the detection of motion or rapid changes in illumination by the avian retina when the animal is exposed at a 2-G environment.

Orlando, R. G.↗

Optical fiber sensors for the non-destructive evaluation of materials

The operation of the modal domain vibration sensor was demonstrated in several simple vibrational systems. Two apparent advantages are the sensors bandwidth and sensitivity. An inherent drawback of standard vibration detection devices is their rapid cost increase with high frequency bandwidth. This sensor showed consistent response in the freqency range of 1.5 to 400 Hz. By imparting very small but measurable excitations in the structures, the sensors ability to respond to very low order vibration induced strain was established. Dynamic ranges on the order of 18 to 22 dB for the CF beam and string systems respectively were observed. The sensor itself represents a very simple system: a coherent source, a single fiber and a low bandwidth detector. The inherent advantages of ruggedness and immunity to external radiation can also be added. Finally, the sensor minimally impairs structural motion through loading, an advantage in monitoring small vibrations or lightweight structures. Some drawbacks of the sensor are also noted.

Source record↗