Search NASA⌕ Search

SEARCH · Search NASA

Results for “reactive power control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Benchmark Calculation for Surry Unit 1 Cycles 1-3 Using the SCALE 6.3/Polaris–PARCS v3.4.2 Code Package

The benchmark calculations were performed for Surry Unit 1 cycles 1–3 to validate the SCALE 6.3/Polaris–Purdue Advanced Reactor Core Simulator (PARCS) v3.4.2 with the ENDF/B–VII.1 56–group library by comparing the simulated results with the measured data. The benchmark results will be used to evaluate uncertainties of the SCALE/Polaris–PARCS code package for pressurized water reactor physics analysis for key nuclear parameters such as reactivity, control bank worth, temperature coefficients, and pin and assembly power peaking factors. This report details plant and fuel design specifications and input data for SCALE/Polaris, GenPMAXS, and PARCS. Additional details are provided for the input and output files produced for the benchmark calculations. The benchmark results were summarized such that they can be used in evaluating uncertainties with other benchmark results for key nuclear parameters.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Benchmark Calculation for the Watts Bar Unit 1 Cycles 1-3 Using the SCALE 6.3/Polaris–PARCS v3.4.2 Code Package

Benchmark calculations for the Watts Bar Unit 1 cycles 1–3 were performed to validate the SCALE 6.3/Polaris–PARCS v3.4.2 with the ENDF/B-VII.1 56-group library by comparing the simulated results with the measured data. The benchmark results are used in evaluating uncertainties of the SCALE/Polaris–PARCS code package for pressurized water reactor physics analysis for key nuclear parameters such as reactivity, control bank worth, temperature coefficients, and pin and assembly power peaking factors. This report details plant and fuel design specifications and input data for SCALE/Polaris, GenPMAXS, and PARCS. Additional details are provided for the input and output files produced for the benchmark calculations. The benchmark results were summarized such that they can be used in evaluating uncertainties for key nuclear parameters with other benchmark results.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Benchmark Calculation for BEAVRS Cycles 1 and 2 Using the SCALE 6.3/Polaris–PARCS v3.4.2 Code Package

This study performed the benchmark calculation for BEAVRS to validate the SCALE 6.3/Polaris–PARCS v3.4.2 code package with the ENDF/B-VII.1 56-group library, comparing the simulated results with the measured data. The benchmark results will be used in evaluating uncertainties of the SCALE/Polaris–PARCS code package for pressurized water reactor physics analysis for key nuclear parameters such as reactivity, control bank worth, temperature coefficients, and pin and assembly power peaking factors. This report details plant and fuel design specifications and input data for SCALE/Polaris as well as GenPMAXS and PARCS. Additionally, detailed information is provided for all the input and output files produced for the benchmark calculations. The benchmark results are summarized herein so that they can be used in evaluating uncertainties for key nuclear parameters with other benchmark results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SCALE 6.3 Validation: Reactor Physics

This study was performed to validate the SCALE/Polaris v6.3.0–PARCS v3.4.2 code procedure with the ENDF/B-VII.1 AMPX 56-group library for light-water reactor analysis by comparing the simulated results with the measured data for critical experiments and operating light-water reactors. Uncertainties of the SCALE/Polaris–PARCS code procedure for light-water reactor physics analysis were evaluated in the validation for key nuclear parameters such as reactivity, control bank work, temperature coefficients, and pin and assembly power peaking factors. In addition, the SCALE/TRITON v6.3.1 procedure with the ENDF/B-VII.1 and VIII.0 252-group and continuous-energy cross sections was validated for non-lightwater reactors including the HTR-10 reactor, the High-Temperature Test Reactor, the Molten Salt Reactor Experiment, and the Experimental Breeder Reactor II.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Validation of the SCALE/Polaris-PARCS Code Procedure with the ENDF/B-VII.1 AMPX 56-Group Library: Pressurized Water Reactor

This study was conducted to validate the SCALE/Polaris v6.3.0–PARCS v3.4.2 code procedure with the Evaluated Nuclear Data File (ENDF)/B-VII.1 AMPX 56-group library for pressurized water reactor (PWR) analysis, by comparing simulated results with measured data for critical experiments and operating PWRs. Uncertainties of the SCALE/Polaris–PARCS code procedure for PWR analysis were evaluated in the validation for the PWR key nuclear parameters such as critical boron concentrations, reactivity, control bank work, temperature coefficients, and pin and assembly power peaking factors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Design Power Control Strategies of Grid-Forming Inverters for Microgrid Application: Preprint

This paper compares two control schemes in the application control layer of a non-PLL grid-forming (GFM) inverter to gain the insights and understanding of how the two schemes affect the dynamic responses of the GFM inverters and the transition operation of microgrids. Both schemes can achieve smooth microgrid transition operation and power tracking, however, the first scheme expects to exhibit more transients due to the feedforward of the inverse dynamic model of the output filter. Simulation results show that both control schemes achieve successful transition operation with smooth transients, and the second control scheme exhibits slightly better transients in the system frequency during islanding operation and the first one has slightly superior transients in the system frequency during reconnection operation. The power tracking performance in the grid-connected mode is evaluated, which shows that the first scheme has better active power tracking and the second one has better reactive power tracking. The analysis and results are useful to develop reliable control schemes for non-PLL GFM inverters because more and more inverters will work as non-PLL grid-forming sources in the future grids due to better stability and reliability.

grid-forming inverter↗

Modeling and control of cascaded bridgeless multilevel rectifier under unbalanced load conditions

The goal of this project is to model and control a novel unidirectional cascaded multilevel bridgeless rectifier as an active front end in medium and high voltage applications. This topology has many advantages over a conventional cascaded H-bridge rectifier, such as lower implementation cost, higher reliability, and greater flexibility with similar power quality. The complete design process of the proposed converter is developed step by step in order to meet all the desired objectives. The steady-state mathematical model is used to develop a method for the voltage balancing of dc cells. Power factor analysis is discussed to mathematically derive requirements for the number of partially controlled and fully controlled H-bridges in the proposed H-bridge converter. Power loss, efficiency, and cost comparison studies between the traditional cascaded H-Bridge converter and the proposed bridgeless converter demonstrate the advantages. After exploring various well-established control methods, a novel control strategy is proposed to achieve dc voltage balancing, fast and robust grid synchronization, power factor correction, and elimination of zero crossing current distortion under both balanced and unbalanced load conditions. The converter can also be used for reactive power compensation in a grid tied power system if a sufficient number of fully controlled H-bridge modules are included. Processor-In-the-Loop (PIL) simulation has been the utilized to validate the performance of discrete control structure. Simulation and experimental results validate the models and control method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling of the TRIGA IPR-R1 research reactor with the Serpent2/RINNOVO Nodal core analysis package

The Serpent2/RINNOVO nodal core analysis code system, a dedicated tool for modeling research reactors, has the capability to accurately predict important core physics parameters involved in the safety of reactor operation, such as various reactivity coefficients, control rod and bank worths including the shutdown margin, power distributions as well as local neutron flux predictions at various core locations of high importance, e.g., at irradiation rigs. In this work, a hexagonal model of the unrodded initial core of the Brazilian IPR-R1 Mark I type TRIGA nuclear reactor has been created using the Serpent2/RINNOVO code system. The choice of employing a hexagonal core geometry representation has mainly been made to facilitate subsequent fuel shuffling operations and core follow calculations of this reactor. Numerical results in terms of the core eigenvalue and the assembly power distribution have then been compared against corresponding full core Serpent2 results to prove feasibility of using the Serpent2/RINNOVO code system for modeling small and highly heterogeneous TRIGA reactors. Overall, RINNOVO predicts the power distribution very accurately but the eigenvalue error still remains quite large. In light of being the very first evaluation of a TRIGA reactor with the RINNOVO nodal core simulator, these results are also considered to be very preliminary. Improved accuracy is expected by incorporating a proper methodology in the current code system for computing discontinuity factors for multi-assembly configurations. Furthermore, improved results are expected by increasing the number of energy groups used by RINNOVO in these core calculations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Forward and inverse predictive transient models of TREAT using surrogate reactivity models

In this work, we present two novel approaches for predicting the power evolution and control rod height of the Transient Reactor Test Facility (TREAT) to support experiment modeling; specifically, transient analysis of the NASA-sponsored Sirius series of experiments. These approaches utilize steady-state Monte Carlo model, point kinetics model, and surrogate models to predict power evolution and control rod axial position during transient experiments. Both approaches were tested and validated against several Sirius experiments that were performed in the TREAT facility at different power levels. The validation test results show very good agreement with the experimental data, and the models were able to accurately predict the power evolution and the axial control rod position with an average error within 3.0%. Finally, this indicates that these approaches will help the reactor engineering team of the TREAT facility in preparing and predicting the power and temperature of the experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Distributed Secondary Control of Grid-Forming Inverters and AC Microgrids: Impacts of Voltage Feedback Choices

In this paper, the operational choices in distributed secondary control are examined, and their impacts on grid-forming (GFM) inverters and grid operation are investigated. In particular, the effects of feedback voltage choices, either average voltage feedback (AVF) or terminal voltage feedback (TVF), are studied with respect to reactive power sharing, voltage regulation, and grid-forming operation during black start. The secondary control used is a subgradient-based distributed cooperative control, and it provides the voltage, angle, and frequency references to the GFM inverters and their primary tracking controls. The overall control architecture employs multi-rate sampling such that the secondary control is slower than the primary control. The operational choices and their control performance are illustrated using a four-GFM-inverter microgrid in MATLAB/SIMULINK. Furthermore, the results show the effectiveness of the secondary controller, and several conclusions are drawn on the voltage feedback signals as the design choices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Deadband Voltage Control and Power Buffering for Extreme Fast Charging Station

Voltage fluctuation is one of the most common challenges that electric vehicle charging station (EVCS) may introduce to the power grid. Local reactive power compensation (Q-compensation) capability of bi-directional electric vehicle (EV) chargers can mitigate the steady-state voltage violations caused by the EV charging itself or changes in the neighboring loads. Power buffering, using energy storage system (ESS), can be utilized to address the voltage transients (sags and swells) as a result of EV charging at the EVCS. To address PI controller’s ‘hunting’ issue, this paper proposes a Q-sign triggered deadband voltage control (V-control) method at the point of common coupling (PCC). In addition, to ensure the ramp rate of EV charging is within the allowable limits set forth by the grid code, a ramp rate control is proposed that uses the ESS as a ‘power buffer’. Lastly, different from most reported work in the literature where no explicit limit of the power electronic converters (PECs) is considered, this work considers a reasonable apparent power capacity limit of the PECs when achieving the V-control. This limit also affects the amount of active power that can be obtained from the grid, and subsequently may require ESS to function as ‘load sharing’ device to provide supplemental active power to satisfy EV load. A case study simulated in MATLAB (interfaced with PLECS) is presented to demonstrate the effectiveness of the proposed approaches for EVCS operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Automatic voltage regulation application for PV inverters in low-voltage distribution grids – A digital twin approach

This paper proposes a hierarchical coordinated control strategy for PV inverters to keep voltages in low-voltage (LV) distribution grids within specified limits. The top layer of the proposed architecture consists of the designed automatic voltage regulation (AVR) application, which has access to voltage measurements and grid parameters from the LV distribution grid, both current and historical. The AVR application solves a constrained optimization problem, which provides a set of local control set-points that bring the voltage across the grid within bounds. The middle layer consists of a local Volt/VAR controller, which is adjusted by the AVR app, while the bottom layer is the inner-loop controller of the PV inverter. The proposed method not only improves the voltage quality in the grid but also manages the reactive power outputs of PV inverters efficiently. Further, a digital twin of the cyber-physical system has also been employed that interacts with the control system to ensure its appropriate operation. The effectiveness of the proposed methodology is demonstrated on a representative low-voltage feeder located in Denmark.

24 POWER TRANSMISSION AND DISTRIBUTION↗

System and method for implementing a zero-sequence current filter for a three-phase power system

In a three-phase, four-wire electrical distribution system, a zig-zag transformer and at least one Cascade Multilevel Modular Inverter (CMMI) is coupled between the distribution system and the neutral. A controller modulates the states of the H-bridges in the CMMI to build an AC waveform. The voltage is chosen by the controller in order to control an equivalent impedance that draws an appropriate neutral current through the transformer. This neutral current is generally chosen to cancel the neutral current sensed in the line. The chosen neutral current may be based on a remotely sensed imbalance, rather than on a local value, determined by the power utility as a critical load point in the system. The desired injection current is then translated by the controller into a desired zero-sequence reactive impedance, based on measurement of the local terminal voltage, allowing the controller to regulate the current without generating or consuming real power.

Benavides, Nicholas↗

Enabling Grid-Forming Control with Fault Ride-Through in Unbalanced Distribution Networks

Distribution networks are often unbalanced, causing oscillatory responses in inverter control designed for balanced conditions. Here, to address this problem, this paper proposes a novel time-domain transformation appropriate for inverter control and enables the decomposition of three-phase unbalanced signals into constant positive and negative components. Relations useful for calculating unbalanced active and reactive power are derived from first principle, providing insight into vector products of unbalanced three-phase signals. Furthermore, a grid-forming control effective under unbalanced conditions is developed, which delivers superior performance while meeting UNIFI1 specifications for grid-forming control under unbalanced conditions. specifications applicable to category 4 inverter-based resource, like setting and regulating frequency/voltage, providing voltage support, sharing active power, injecting negative sequence current, and riding through faults. A current limiter is proposed for safe fault ride-through and integrates with the grid-forming control featuring frequency/voltage droop controllers and current and voltage control loops. The transformation of interconnected inverters is formulated and stability of the proposed control analyzed to support robust parameter selections. The effectiveness of the proposed transformation and grid-forming control is demonstrated through analytical results and real-time simulation of a IEEE 123 distribution network on the Real-Time Digital Simulator. Comparison with existing methods shows that the proposed strategy satisfies the UNIFI specifications with a much better performance.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Simulation of CEFR neutronic start-up tests with FENNECS

This paper presents simulation results of selected Neutronic Start-up Tests of the China Experimental Fast Reactor (CEFR) obtained by the neutronics code FENNECS that have been performed within the frame of the IAEA Coordinated Research Program I31032. The Finite Element Neutronics code FENNECS is developed at GRS and solves the few-group steady-state and transient diffusion equation using a Galerkin-based finite element approach. Its main purpose is the safety assessment of Small Modular Reactors and Micro Reactors with complex geometry (e.g., rotating control drums) which gain increased interest internationally. Serpent has been applied to create reference models of the CEFR and cross-section libraries in 10 energy groups for FENNECS. Using these libraries, the following experiments have been simulated with FENNECS: net criticality, control rod integral and differential worth, void reactivity effect, subassembly exchange reactivity effects and reaction rate distribution. The obtained satisfactory agreements with the measurements represent a valuable contribution to the validation of FENNECS. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Identification of a Delay Attack in the Secondary Control of Grid-Tied Inverter Systems

This work is developed for the identification of a denial-of-service cyberattack on the secondary controller of inverter systems which is connected to the power grid. The identification is made through the dynamic response of the reactive power (Q) of the system under attack. By observing the dynamic characteristic of Q, it is possible to correlate the attack with the nominal response of the hierarchical controller. The article shows that the occurrence of the attack can be identified through a supervisory control that runs a model in parallel. The article argues that after an early identification of the attack, a local controller can take action to mitigate its effects on the system’s response.

Roig Greidanus, Mateo D.↗

Real-time Simulation of Coordinated Sub-Transmission Volt-Var Control Tool under High Distributed PV Penetration

With the rapid penetration of intermittent solar photovoltaic (PV) and other distributed energy resources (DER) into the grid, and subsequent changes in power flow patterns in both distribution and sub-transmission, voltage regulation is becoming a major challenge. It is prudent to leverage PV and DER to provide ancillary services to the grid, such as voltage regulation. Recently, a quasi-static, coordinated real-time sub transmission volt-var control algorithm (CReST-VCT) was developed for voltage regulation under high PV penetration by dispatching the reactive power settings of the shunt devices and PV inverters. The algorithm was validated offline, on a quasistatic study. Such quasi-static dispatching algorithms cannot guarantee its performance for highly nonlinear dynamical power systems. In this paper the performance of the algorithm is validated with a real time nonlinear dynamic simulation of a modified IEEE 118 bus system in Opal-RT. The real time simulation is used to emulate the actual system operation, providing a more realistic testing environment for CReST-VCT. The dispatch and control signals are communicated between the power system (Opal solver) and the control center (GAMS solver) in real-time with a MODBUS bridge. The results demonstrate i) system is stable with the new dispatch points ii) significant improvement in system-wide voltage profiles compared to an uncontrolled scenario. Another significant contribution of the work is developing a framework for dispatchable, long duration dynamic simulations that can be leveraged for market/dispatch studies.

CReST-VCT, Opal-RT, Volt/Var Control, renewable in↗

Hierarchical Distributed Optimal Power Flow of HV and MV Distribution Networks With Continuous and Discrete Devices

With large-scale distributed photovoltaics (PVs) being integrated into distribution networks (DNs), coordinated optimal power flow (OPF) of high voltage (HV) and medium voltage (MV) DNs should be investigated to optimally dispatch the distributed PVs and other network devices. Here, this paper presents a hierarchical distributed OPF method for HV and MV DNs with on-load tap changers, reactive power compensators, feeder switches and distributed PVs. A hierarchical master-slave control architecture is applied to implement coordinated OPF of two-layer DNs. The HV master problem and MV subproblems are transformed into mixed-integer convex problems respectively with second order cone programming and LinDistFlow approximation. Since there is no efficient distributed algorithm to solve such OPF models with integer subproblems, a novel distributed algorithm is proposed in this paper to efficiently solve the hierarchical coordinated OPF model with integer subproblems in a distributed manner. In the proposed algorithm, the coordinated OPF model is solved in a branch-and-bound framework, where in each branch node generalized Benders decomposition (GBD) algorithm is applied to decompose the coordinated OPF model into a master problem and relaxed subproblems and solves them iteratively to get optimal solution. The GBD optimal and feasible cutting planes generated in a branch node are proved to be valid for its descendants. Moreover, three acceleration techniques are introduced into the proposed algorithm to improve computational efficiency. Finally, the effectiveness and accuracy of the proposed method are verified via simulation tests in Jinzhai DNs of China.

42 ENGINEERING↗