Search NASA⌕ Search

SEARCH · Search NASA

Results for “reference device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

GaN-on-GaN p-i-n diodes with avalanche capability enabled by eliminating surface leakage with hydrogen plasma treatment

Traditional mesa terminations require precise angle design to reduce the electric field at the edge and surface treatment to reduce etch damage. Otherwise, the device usually suffers a premature breakdown. This work proposes the use of easy-to-implement hydrogen plasma treatment to solve the premature breakdown caused by mesa and demonstrates the avalanche capability in GaN-on-GaN p-i-n diodes. The breakdown electric field when the avalanche occurred was ∼2.3 MV/cm at room temperature for a GaN drift layer with a doping concentration of ∼7 × 1015 cm−3, which is consistent with the theoretical value. The temperature coefficient of the avalanche breakdown voltage of the devices was 4.64–4.85 × 10−4 K−1. This work shows a simple and effective approach to achieve avalanche capability in vertical GaN power devices, which can serve as an important reference for the future development of efficient and robust GaN power electronics.

Fu, Kai (ORCID:0000000294057512)↗

Scaling Superconducting Quantum Computers with Chiplet Architectures

Fixed-frequency transmon quantum computers (QCs) have advanced in coherence times, addressability, and gate fidelities. Unfortunately, these devices are restricted by the number of on-chip qubits, capping processing power and slowing progress toward fault-tolerance. Although emerging transmon devices feature over 100 qubits, building QCs large enough for meaningful demonstrations of quantum advantage requires overcoming many design challenges. For example, today’s transmon qubits suffer from significant variation due to limited precision in fabrication. As a result, barring significant improvements in current fabrication techniques, scaling QCs by building ever larger individual chips with more qubits is hampered by device variation. Severe device variation that degrades QC performance is referred to as a defect. Here, we focus on a specific defect known as a frequency collision. When transmon frequencies collide, their difference falls within a range that limits two-qubit gate fidelity. Frequency collisions occur with greater probability on larger QCs, causing collision-free yields to decline as the number of on-chip qubits increases. As a solution, we propose exploiting the higher yields associated with smaller QCs by integrating quantum chiplets within quantum multi-chip modules (MCMs). Yield, gate performance, and application-based analysis show the feasibility of QC scaling through modularity. Our results demonstrate that chiplet architectures, relative to monolithic designs, benefit from average yield improvements ranging from 9.6 – 92.6 × for ≲5 qubit machines. In addition, our simulations explore the design space of chiplet systems and discover configurations that demonstrate average two-qubit gate infidelity reductions that are at best 0.815 × their monolithic counterpart. Lastly, we observe that carefully-selected modular systems achieve fidelity improvements on a range of benchmark circuits.

quantum architecture↗

Solar sensor with autocollimator

Monolithic structure, consisting of fused quartz fabricated solar sensor and autocollimator, measures angle between reference surface on spacecraft and solar vector. Device compensates for errors caused by changes in the alignment of its mountings or component parts. Integrated concept is advantageous whenever sensor mounting errors constitute problems.

Fain, D. L.↗

Constant-power source for resistive load

Device uses operational amplifiers, dividers, subtractor, pulsed reference amplifier, and associated integrated-circuit components to deliver constantly-adjustable continual power to variable-resistance load for specialized low-power instrumentation applications.

Nagle, E. M.↗

Direct conversion of light to radio frequency energy

A description is presented of the test results obtained with the latest models of the phototron. The phototron was conceived as a replacement for the high voltage solar cell-high power klystron combination for the solar power satellite concept. Physically, the phototron is a cylindrical evacuated glass tube with a photocathode, two grids, and a reflector electrode in a planar configuration. The phototron can be operated either in a biased mode where a low voltage is used to accelerate the electron beam produced by the photocathode or in an unbiased mode referred to as self-oscillation. The device is easily modulated by light input or voltage to broadcast in AM or FM. The range of operation of the present test model phototrons is from 2 to 200 MHz.

Freeman, J. W.↗

Navigation of the Space Shuttle

Navigational systems and operations for the Space Shuttle are described. All navigational instrumentation is controlled from within the pressurized main cabin. Measurements of the state vector and the attitude are made with an inertial measurement unit (IMU), which uses data initialized at the moment of take-off. Orbital location is calculated in approximations using the initial propulsion conditions, models of the gravity field, and aerodynamic drag forces. Updates are periodically received from ground tracking stations. IMU continues attitude information, and additional references are made with an automated startracker device. Information can also be gathered by optical alignment, and future systems will include radar tracking in an approach mode. Deorbit is accompanied by IMU altitude measurements as well as calculations of altitude based on drag measurements. Barometric measurements begin at about 80,000 ft altitude. Signals are received from TACAN beginning at 145,000 ft, and the microwave scanning beam landing system is started at 20,000 ft. Various radionavigation systems are also employed in all flight phases.

Edwards, A., Jr.↗

Solid-state curved focal plane arrays

The present invention relates to curved focal plane arrays. More specifically, the present invention relates to a system and method for making solid-state curved focal plane arrays from standard and high-purity devices that may be matched to a given optical system. There are two ways to make a curved focal plane arrays starting with the fully fabricated device. One way, is to thin the device and conform it to a curvature. A second way, is to back-illuminate a thick device without making a thinned membrane. The thick device is a special class of devices; for example devices fabricated with high purity silicon. One surface of the device (the non VLSI fabricated surface, also referred to as the back surface) can be polished to form a curved surface.

Nikzad, Shouleh↗

Suited and Unsuited Hybrid III Impact Testing and Finite Element Model Characterization

NASA spacecraft design requirements for occupant protection are a combination of the Brinkley Dynamic Response Criteria and injury assessment reference values (IARV) extracted from anthropomorphic test devices (ATD). For the ATD IARVs, the requirements specify the use of the 5th percentile female Hybrid III and the 95th percentile male Hybrid III. Each of these ATDs is required to be fitted with an articulating pelvis (also known as the aerospace pelvis) and a straight spine. The articulating pelvis is necessary for the ATD to fit into spacecraft seats, while the straight spine is required as injury metrics for vertical accelerations are better defined for this configuration. Sled testing of the Hybrid III 5th Percentile Female Anthropomorphic Test Device (ATD) was performed at Wright-Patterson Air Force Base (WAPFB). Two 5th Percentile ATDs were tested, the Air Force Research Lab (AFRL) and NASA owned Hybrid III ATDs with aerospace pelvises. Testing was also conducted with a NASA-owned 95th Percentile Male Hybrid III with aerospace pelvis at WPAFB. Testing was performed using an Orion seat prototype provided by Johnson Space Center (JSC). A 5-point harness comprised of 2 inch webbing was also provided by JSC. For suited runs, a small and extra-large Advanced Crew Escape System (ACES) suit and helmet were also provided by JSC. Impact vectors were combined frontal/spinal and rear/lateral. Some pure spinal and rear axis testing was also performed for model validation. Peak accelerations ranged between 15 and 20-g. This range was targeted because the ATD responses fell close to the IARV defined in the Human-Systems Integration Requirements (HSIR) document. Rise times varied between 70 and 110 ms to assess differences in ATD responses and model correlation for different impact energies. The purpose of the test series was to evaluate the Hybrid III ATD models in Orion-specific landing orientations both with and without a spacesuit. The results of these tests were used by the NASA Engineering and Safety Center (NESC) to validate the finite element model (FEM) of the Hybrid III 5th Percentile Female ATD. Physical test data was compared to analytical predictions from simulations, and modelling uncertainty factors have been determined for each injury metric. Additionally, the test data has been used to further improve the FEM, particularly in the areas of the ATD preload, harness, and suit and helmet effects.

Lawrence, C.↗

Method and system for microwave mixer phase response measurement

A system, method and apparatus for mixer phase response measurement comprises a vector network analyzer connectable to a device under test, an additional device connected to the analyzer the additional device configured to have an equal phase response to that of the device under test, a local oscillator connected to the device under test and the additional device, a series of switches connecting the device under test and the additional device to a vector voltmeter, and a reference generator connected to the vector voltmeter.

Frolov, Daniil↗

Determining iconometric parameters of imaging devices using a wide-angle collimator

The problem of determining the iconometric parameters of the imaging device can be solved if the camera being calibrated is used to obtain the image of a group of reference points, the directions to which are known. In order to specify the imaging device coordinate system, it is sufficient in principle to obtain on the picture the images of three reference points which do not lie on a single straight line. Many more such points are required in order to determine the distortion corrections, and they must be distributed uniformly over the entire field of view of the camera being calibrated. Experimental studies were made using this technique to calibrate photographic and phototelevision systems. Evaluation of the results of these experiments permits recommending collimators for calibrating television and phototelevision imaging systems, and also short-focus small-format photographic cameras.

Ziman, Y. L.↗

Anthropomorphic Telemanipulation System in Terminus Control Mode

This paper describes a prototype anthropomorphic kinesthetic telepresence system that is being developed at JPL. It utilizes dexterous terminus devices in the form of an exoskeleton force-sensing master glove worn by the operator and a replica four finger anthropomorphic slave hand. The newly developed master glove is integrated with our previously developed non-anthropomorphic six degree of freedom (DOF) universal force-reflecting hand controller (FRHC). The mechanical hand and forearm are mounted to an industrial robot (PUMA 560), replacing its standard forearm. The notion of 'terminus control mode' refers to the fact that only the terminus devices (glove and robot hand) are of anthropomorphic nature, and the master and slave arms are non-anthropomorphic. The system is currently being evaluated, focusing on tool handling and astronaut equivalent task executions. The evaluation revealed the system's potential for tool handling but it also became evident that hand tool manipulations and space operations require a dual arm robot. This paper describes the system's principal components, its control and computing architecture, discusses findings of the tool handling evaluation, and explains why common tool handling and EVA space tasks require dual arm robots.

glove exoskeleton force-sensing master glove EVA s↗

Power Electronics Being Developed for Deep Space Cryogenic Applications

Electronic circuits and systems designed for deep space missions need to operate reliably and efficiently in harsh environments that include very low temperatures. Spacecraft that operate in such cold environments carry a large number of heaters so that the ambient temperature for the onboard electronics remains near 20 C. Electronics that can operate at cryogenic temperatures will simplify system design and reduce system size and weight by eliminating the heaters and their associated structures. As a result, system development and launch cost will be reduced. At the NASA Glenn Research Center, an ongoing program is focusing on the development of power electronics geared for deep space low-temperature environments. The research and development efforts include electrical components design, circuit design and construction, and system integration and demonstration at cryogenic temperatures. Investigations are being carried out on circuits and systems that are targeted for use in NASA missions where low temperatures will be encountered: devices such as ceramic and tantalum capacitors, metal film resistors, semiconductor switches, magnetics, and integrated circuits including dc/dc converters, operational amplifiers, voltage references, and motor controllers. Test activities cover a wide range of device and circuit performance under simple as well as complex test conditions, such as multistress and thermal cycling. The effect of low-temperature conditions on the switching characteristics of an advanced silicon-on-insulator field effect transistor is shown. For gate voltages (VGS) below 2.6 V, drain currents at -190 C are lower than drain currents at room temperature (20 C).

Patterson, Richard L.↗

An assembly to provide a time reference for the JPL Network Operations Control Center, Real-Time

A device is described which provides the value of date coordinated universal time (date UTC) to the JPL Network Operations Control Center, Real Time (NOCC-RT) facility. The NOCC-RT is the real time portion of the NOCC upgrade task. The time scale is generated in the NOCC-RT clock processor; however, there is a continuous reference to UTC, as realized by the National Institute of Standards and Technology and transmitted by Earth orbiting satellites. An important functional design requirement is the 99.9 pct. availability.

Clements, P. A.↗

Fiber optic reference frequency distribution to remote beam waveguide antennas

In the NASA/JPL Deep Space Network (DSN), radio science experiments (probing outer planet atmospheres, rings, gravitational waves, etc.) and very long-base interferometry (VLBI) require ultra-stable, low phase noise reference frequency signals at the user locations. Typical locations for radio science/VLBI exciters and down-converters are the cone areas of the 34 m high efficiency antennas or the 70 m antennas, located several hundred meters from the reference frequency standards. Over the past three years, fiber optic distribution links have replaced coaxial cable distribution for reference frequencies to these antenna sites. Optical fibers are the preferred medium for distribution because of their low attenuation, immunity to EMI/IWI, and temperature stability. A new network of Beam Waveguide (BWG) antennas presently under construction in the DSN requires hydrogen maser stability at tens of kilometers distance from the frequency standards central location. The topic of this paper is the design and implementation of an optical fiber distribution link which provides ultra-stable reference frequencies to users at a remote BWG antenna. The temperature profile from the earth's surface to a depth of six feet over a time period of six months was used to optimize the placement of the fiber optic cables. In-situ evaluation of the fiber optic link performance indicates Allan deviation on the order of parts in 10(exp -15) at 1000 and 10,000 seconds averaging time; thus, the link stability degradation due to environmental conditions still preserves hydrogen maser stability at the user locations. This paper reports on the implementation of optical fibers and electro-optic devices for distributing very stable, low phase noise reference signals to remote BWG antenna locations. Allan deviation and phase noise test results for a 16 km fiber optic distribution link are presented in the paper.

Calhoun, Malcolm↗