Search NASA⌕ Search

SEARCH · Search NASA

Results for “reference material”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Earth's Earliest Ecosystems in the C: The Use of Microbial Mats to Demonstrate General Principles of Scientific Inquiry and Microbial Ecology

Microbial mats are living examples of the most ancient biological communities on Earth. As Earth's earliest ecosystems, they are centrally important to understanding the history of life on our planet and are useful models for the search for life elsewhere. As relatively compact (but complete) ecosystems, microbial mats are also extremely useful for educational activities. Mats may be used to demonstrate a wide variety of concepts in general and microbial ecology, including the biogeochemical cycling of elements, photosynthesis and respiration, and the origin of the Earth's present oxygen containing atmosphere. Microbial mats can be found in a number of common environments accessible to teachers, and laboratory microbial mats can be constructed using materials purchased from biological supply houses. With funding from NASA's Exobiology program, we have developed curriculum and web-based activities centered on the use of microbial mats as tools for demonstrating general principles in ecology, and the scientific process. Our web site (http://microbes.arc.nasa.gov) includes reference materials, lesson plans, and a "Web Lab", featuring living mats maintained in a mini-aquarium. The site also provides information as to how research on microbial mats supports NASA's goals, and various NASA missions. A photo gallery contains images of mats, microscopic views of the organisms that form them, and our own research activities. An animated educational video on the web site uses computer graphic and video microscopy to take students on a journey into a microbial mat. These activities are targeted to a middle school audience and are aligned with the National Science Standards.

Bebout, Brad M.↗

Direct analysis of cotton swipes for plutonium isotope determination by microextraction-ICP-MS

This study demonstrates a method for determining the isotopic composition of low-level (sub-pg) plutonium (Pu) directly from a cotton swipe. Environmental sample (ES) swipes are routinely employed as a tool for monitoring activities in nuclear facilities. Traditional ES swipe analysis, as employed in nuclear safeguards, utilizes laborious ashing, digestion, and chemical separation procedures prior to mass spectrometric (MS) analysis. Here, an innovative sample introduction technique employing a microextraction probe to extract Pu directly from the swipe surface is described. The microextraction probe lowers onto the swipe surface, seals on a small area (8 mm 2 ), and delivers solvent (2% HNO 3 ) to extract actinide material that may be present. The extracted analyte is subsequently directed into a sector field inductively coupled plasma (ICP)-MS for isotope ratio determination. This microextraction-ICP-MS method successfully determined the isotopic composition ( 240 Pu/ 239 Pu and 242 Pu/ 239 Pu) of three Pu certified reference materials (CRM 136, 137, and 138) that were deposited (1 pg) onto ES swipes. The percent relative difference from the certified value, uncorrected for instrumental fractionation, was <2% for the 240 Pu/ 239 Pu ratio on all three CRMs and <10% for the 242 Pu/ 239 Pu ratio on CRM 136 and 138. Here, the percent relative standard deviation, an estimate of the sample-to-sample isotopic precision, was <4% for the 240 Pu/ 239 Pu and <15% for the 242 Pu/ 239 Pu. Method limits of detection were determined, based on measurements of an enriched 244 Pu material, to be ~7 fg. Additionally, a mixed uranium (U) and Pu deposition was made to determine the method's ability to simultaneously extract U and Pu and determine the isotopic composition of both analytes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of Backside Textures for Genesis Solar Wind Silicon Collectors

Genesis solar wind collectors were comprised of a suite of 15 types of ultrapure materials. The single crystal, pure silicon collectors were fabricated by two methods: float zone (FZ) and Czochralski (CZ). Because of slight differences in bulk purity and surface cleanliness among the fabrication processes and the specific vendor, it is desirable to know which variety of silicon and identity of vendor, so that appropriate reference materials can be used. The Czochralski method results in a bulk composition with slightly higher oxygen, for example. The CZ silicon array wafers that were Genesis-flown were purchased from MEMC Electronics. Most of the Genesis-flown FZ silicon was purchased from Unisil and cleaned by MEMC, although a few FZ wafers were acquired from International Wafer Service (IWS).

Gonzalez, C. P.↗

Theory and Practical Design of Phase-locked Receivers, Volume I

This is Volume I of a two-volume work on the theory, of phase-locked receivers, with pertinent reference material on practical receiver design. Volume I is primarily devoted to the performance of carrier-tracking loops, including a rigorous treatment of narrow-band systems having IF limiters. The bulk of the work is based on a theoretical linear model, but a nonlinear method is also presented to predict behavior near the threshold. The emphasis throughout the work is toward completeness, simplicity, and internal consistency of the material assembled. Part I of this Volume is an exposition of the theory, the resulting equations, and the design philosophy that have enabled the phase-lock concept to evolve into the basic principle underlying the most sensitive receivers il, the world today. Part II is a condensed version of Part I, intended as a quick reference to formulas, definitions, and salient design considerations.

RECEIVER↗

Differential Scanning Calorimetry (DSC) for planetary surface exploration

Differential Scanning Calorimetry (DSC) is the quantitative measurement of the enthalpic response of a material to a systematic change in temperature. In practice, the heat flow into or outward from a sample is measured as the sample is heated or cooled at a carefully controlled rate. DSC superficially resembles, but is not the same as differential thermal analysis (DTA), which is the measurement of temperature differences between a sample and reference material as the pair is heated or cooled. The fundamental properties measured by DSC are enthalpies and temperatures of phase transitions and constant-pressure heat capacities. Depending on instrument design and the nature of the sample, high-quality DSC analyses can be obtained on only a few milligrams of solid materials. DSC requires direct contact with the sample and generally degrades, if not destroys, the sample as a consequence of heating. In laboratory applications, it is common to subject the gaseous effluent from the DSC to analysis by a separate evolved-gas analyzer (EGA).

Gooding, James L.↗

Utilization of traceable standards to validate plutonium isotopic purification and separation of plutonium progeny using AG MP-1M resin for nuclear forensic investigations

Radio-chronometric studies on plutonium (Pu) materials require independent measurement of the Pu (parent) content and isotopic distribution as well as concentration and isotopic distribution of the plutonium isotopic decay products. We performed a series of experiments to demonstrate the consistency of separations using the Lewatit MP 800 macroporous anion exchange resin and the AG MP-1M resin with traceable Pu isotopic certified reference material (CRM) standards 136, 137, 138, and 126-A. Two different mesh-sizes of the AG MP-1M resin were tested and the 50–100 mesh size resin was found to work more efficiently for the separation task. Both Lewatit and AG MP-1M resins were found to perform satisfactorily for quantitatively extracting the americium (Am) and uranium (U) progeny as well as gallium (Ga) present as a tracer in the Pu material. Both resins were effective in removing isobaric interferences from the Pu fraction used in isotopic measurements by thermal ionization mass spectrometry (TIMS). To address the co-elution of uranium and gallium, Alizarin red S (ARS) was used as a colorimetric dye to determine the behavior of UO 2 2+ and Ga 3+ on AG MP-1M resin with various acidic solutions as eluents using UV–vis spectra. Poor resolution of these peaks complicated quantitative analysis by UV–vis spectroscopy, but these results were informative in planning automated separation experiments by HPLC. LA-UR-24-28919.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

230Th/234U radiochronometry for uranium materials by alpha spectrometry for nuclear forensics analysis

We have developed an alpha spectrometry method for 230Th/234U radiochronometry to determine the model separation age for uranium materials. This method offers an alternative to the more commonly used, but significantly more resource intensive multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) while providing similar accuracy and precision. The development included radiochemical separation of uranium and thorium, calibration of the 232U tracer and the alpha spectrometry measurement. The method was validated by analyzing a certified reference material, CRM 125-A, which is a uranium oxide pellet assay, isotopic, and radiochronometric standard. The results were compared to those obtained by our routine MC-ICP-MS 230Th/234U radiochronometry analysis method to assess the performance parameters for alpha spectrometry compared to the state-of-the-art technique.

Macsik, Zsuzsanna [Los Alamos National Laboratory ↗

Radiation Hardness Assurance (RHA) Guideline

Radiation Hardness Assurance (RHA) consists of all activities undertaken to ensure that the electronics and materials of a space system perform to their design specifications after exposure to the mission space environment. The subset of interests for NEPP and the REAG, are EEE parts. It is important to register that all of these undertakings are in a feedback loop and require constant iteration and updating throughout the mission life. More detail can be found in the reference materials on applicable test data for usage on parts.

Radiation Hardness Assurance (RHA)↗

Method of determining load in anisotropic non-crystalline materials using energy flux deviation

An ultrasonic wave is applied to an anisotropic sample material in an initial direction and the intensity of the ultrasonic wave is measured on an opposite surface of the sample material by two adjacent receiving points located in an array of receiving points. A ratio is determined between the measured intensities of two adjacent receiving points, the ratio being indicative of an angle of flux deviation from the initial direction caused by an unknown applied load. This determined ratio is then compared to a plurality of ratios of a similarly tested, similar anisotropic reference material under a plurality of respective, known load conditions, whereby the load applied to the particular anisotropic sample material is determined. A related method is disclosed for determining the fiber orientation from known loads and a determined flux shift.

Prosser, William H.↗

Adapting Nuclear Forensics from Light Water to Molten Salt Reactors: A Survey of Emerging Needs

Rising interest in molten salt reactors for commercial power production presents an opportunity to evaluate the techniques used to characterize materials of nuclear forensic interest. Since extensive research has been performed to identify and develop signatures of light water reactor (LWR) materials (e.g. uranium ore concentrates and uranium dioxide fuel pellets), we use this as a basis to explore possibilities for molten salt signature development. Through this comparative method, nuclear forensic signatures used today to identify the provenance of nuclear materials found out of regulatory control are adapted to molten salt reactor (MSR) fuel cycle materials. Radiological, elemental composition, isotopic composition, and model age signatures will likely not need large adaptations before being applied to MSR materials but may need to expand to be applicable to both thorium- and uranium-fueled systems. The liquid nature of molten salt fuel may erase signatures related to production and irradiation history that are informative for typical LWR materials. However, it may also lead to opportunities for new signatures, such as cooling rate–controlled morphology. Targets identified for further research include radiological attributes of fuel salts; elemental, chemical, and isotopic analysis of salts with differing production routes; morphological effects of various thermodynamic environments; and relevant fuel cycle radiochronometers. Additionally, the comparative nature of the proposed signatures implies a need for MSR-relevant databases and the production of salt standard reference materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

DEVELOPMENT OF STANDARDIZED LUNAR REGOLITH SIMULANT MATERIALS

Lunar exploration activities require scientific and engineering studies that use standardized testing procedures and ultimately support flight certification of hardware and the development of technologies for their use on the lunar surface. It is necessary to anticipate the full range of source materials and environmental constraints that are expected on the Moon and Mars, and to evaluate in-situ resource utilization (ISRU) coupled with testing and development. Historical use of lunar simulants has focused on physical aspects of the lunar regolith for landing and transportation activities. Lunar mare simulants MLS-1 and JSC-1 have been developed, but supplies have been exhausted. Renewed emphasis on exploration and ISRU activities requires development of standardized simulant reference materials that are traceable interlaboratory standards for testing and simulate the lunar regolith in terms of physical, chemical, and mineralogical properties. This new generation of lunar regolith simulants must therefore support both technological development and testing methods. These issues were extensively discussed at the 2005 Lunar Regolith Simulant Materials Workshop.

Carpenter, P.↗

Wrinkle ridges in the floor material of Kasei Valles, Mars: Nature and origin

Wrinkle ridges on Mars occur almost exclusively in smooth plains material referred to as ridged plains. One of the largest contiguous units of ridged plains occurs on Lunae Planum on the eastern flank of the Tharsis rise. The eastern, western, and northern margins of the ridged plains of Lunae Planum suffered extensive erosion in early Amazonian channel-forming events. The most dramatic example of erosion in early Amazonian plains is in Kasei Valles. The nature an origin of the wrinkle ridges in the floor material of Kasei Valles are discussed.

Watters, Thomas R.↗

A Review of Nuclear Forensics: 2016-2020

The study of nuclear forensics harkens back to the Manhattan Project-era, when scientists first started to analyze the debris from the 1945 Trinity test. Political turmoil stemming from the Cold War and the rehabilitation of Germany following WWII has led to new challenges in international security involving nuclear proliferation. Nuclear materials have, on occasion, been lost, misplaced, or stolen from former Soviet countries, and illicit materials have been interdicted all over the world. The National Technical Nuclear Forensics Center (NTNFC) was established in 2006, and has been at the forefront of drive to advance nuclear forensic capabilities in the United States. The ultimate goal of nuclear forensics is to examine nuclear and other radioactive materials using analytical techniques to determine origin and history of the material, particularly in the context of law enforcement investigations. Nuclear forensics can be divided into two parts: predetonation and post-detonation. Pre-detonation forensics, as the name implies, is the investigation of a nuclear material or weapon that has not been detonated or involved in an explosion, whereas postdetonation forensics is the study of activation or fission products in debris or the environment following the use of a nuclear or radiological dispersal device (RDD). Both parts require a number of analytical chemical and radiochemical techniques to determine identification of the material. Many advancements in analytical techniques, including rapidity, sample size, and forensic signatures have been made in recent years. The analytical methods that can be used in a nuclear forensic investigation, such as mass spectrometry and gamma spectroscopy, have been described in detail in previous reviews, including Straub et.al, and will not be explained here. This review will discuss recent publications (from 2016 to present) describing advancements of techniques such as radiochronometry, morphology, development of novel reference materials, and inter-laboratory collaborations for both pre- and post-detonation nuclear forensics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Depth profiling and standardization from the back side of a sample for accurate analyses: Emphasis on quantifying low‐fluence, shallow implants in diamond‐like carbon

Rationale Back‐side thinning of wafers is used to eliminate issues with transient sputtering when analyzing near‐surface element distributions. Precise and accurate calibrated implants are created by including a standard reference material during the implantation. Combining these methods allows accurate analysis of low‐fluence, shallow features even if matrix effects are a concern. Methods Implanted Na (<2.0 × 10 11 ions/cm 2 , peaking <50 nm) in diamond‐like carbon (DLC) film on silicon (solar wind returned by NASA's Genesis mission) was prepared for measurement as follows. Implanted surfaces of samples were epoxied to wafers and back‐side‐thinned using physical or chemical methods. Thinned samples were then implanted with reference ions for accurate quantification of the solar wind implant. Analyses used a CAMECA IMS 7f‐GEO SIMS in depth‐profiling mode. Results Back‐side‐implanted reference ions reduced the need to change sample mounts or stage position and could be spatially separated from the solar wind implant even when measuring monoisotopic ions. Matrix effects in DLC were mitigated and the need to find an identical piece of DLC for a reference implant was eliminated. Accuracy was only limited by the back‐side technique itself. Conclusions Combining back‐side depth profiling with back‐side‐implanted internal standards aides quantification of shallow mono‐ and polyisotopic implants. This technique helps mitigate matrix effects and keeps measurement conditions consistent. Depth profile acquisition times are longer, but if sample matrices are homogeneous, procedural changes can decrease measurement times.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Aspects of Crystal Growth and Atomic-Scale Characterization of U/Th Age-Dating Particles

Trace analysis of particulate material collected on environmental swipe samples continues to be one of the cornerstones of the IAEA’s process of verifying member state compliance as part of the Non-Proliferation Treaty (NPT). While complementary to traditional bulk analysis, the ability to measure individual particles can be far more impactful from a radiochronometry perspective. The 234U/230Th radiochronometer is being evaluated as a means of establishing model ages for discrete particles with sufficient confidence. To support the extension of current capabilities, reference materials with a suitable particle form factor and well-documented purification date are actively sought for development with large geometry secondary ion mass spectroscopy.

Nuclear Safeguards, IAEA, Particle Standards↗

Large-Scale Interlaboratory DI-FT-ICR MS Comparability Study Employing Various Systems

We report ultra-high resolution mass spectrometry (UHR-MS) coupled with direct infusion (DI) electrospray ionization offers a fast solution for accurate untargeted profiling. Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometers have been shown to produce a wealth of insights into complex chemical systems because they enable unambiguous molecular formula assignment even if the vast majority of signals is of unknown identity. Inter-laboratory comparisons are required to apply this type of instrumentation in quality control (for food industry or pharmaceutics), large-scale environmental studies or clinical diagnostics. Extended comparisons employing different FT-ICR MS instruments with qualitative direct infusion analysis are scarce since the majority of detected compounds cannot be quantified. The extent to which observations can be reproduced by different laboratories remains unknown. We set up a preliminary study which encompassed a set of seventeen laboratories around the globe, diverse in instrumental characteristics and applications, to analyze the same sets of extracts from commercially available standard human blood plasma and Standard Reference Material (SRM) for blood plasma (SRM1950), which were delivered at different dilutions or spiked with different concentrations of pesticides. The aim of this study was to assess the extent to which the outputs of differently tuned FTICR mass spectrometers, with different technical specifications, are comparable for setting the frames of a future DI-FT-ICR MS ring trial. We concluded that a cluster of five laboratories, with diverse instrumental characteristics showed comparable and representative performance across all experiments, setting a reference to be used in a future ring trial on blood plasma.

47 OTHER INSTRUMENTATION↗

Integrating crystallographic and computational approaches to carbon-capture materials for the mitigation of climate change

Here, this article presents an overview of the current state of the art in the structure determination of microporous carbon-capture materials, as discussed at the recent NIST workshop “Integrating Crystallographic and Computational Approaches to Carbon-Capture Materials for the Mitigation of Climate Change”. The continual rise in anthropogenic CO 2 concentration and its effect on climate change call for the implementation of carbon capture technologies to reduce the CO 2 concentration in the atmosphere. Porous solids, including metal–organic frameworks (MOFs), are feasible candidates for gas capture and storage applications. However, determining the structure of these materials represents a significant obstacle in their development into advanced sorbents. The existing difficulties can be overcome by integrating crystallographic methods and theoretical modeling. The workshop gathered experimentalists and theorists from academia, government, and industry to review this field and identify approaches, including collaborative opportunities, required to develop tools for rapid determination of the structures of porous solid sorbents and the effect of structure on the carbon capture performance. We highlight the findings of that workshop, especially in the need for reference materials, standardized procedures and reporting of sorbent activation and adsorption measurements, standardized reporting of theoretical calculations, and round-robin structure determination.

36 MATERIALS SCIENCE↗

Aerodynamic mission concepts for the Mars sample return mission

Future plans for the continued exploration of Mars call for a sample return mission. This plan proposes bringing a distributed, selected sample of Mars material from several locales on Mars back to earth. The mission options studied to date utilize an extensive number of aerodynamic concepts not previously planned in past planetary exploration programs. These include various modes of orbit modification using atmospheric braking, aeromaneuvering to effect precision surface landing, very low ballistic entry for a network of surface penetrators, low flying hydrazine powered airplanes, balloons, ascent vehicles and direct entry of the samples on return to earth. This paper will discuss the concepts and their feasibility along with technology problems associated with them as surveyed from the reference material. The paper focuses primarily on the aerocapture technique as it relates to Mars orbit modification. Remaining orbit modification techniques are also discussed briefly for comparison.

Cruz, M. I.↗