Guest Editorial High Performance Computing (HPC) Applications for a More Resilient and Efficient Power Grid

The power grid has been evolving over the last 120 years, but it is seeing more changes in this decade and next than it has seen over the past century. In particular, the widespread deployment of intermittent renewable generation, smart loads and devices, hierarchical and distributed control technologies, phasor measurement units, energy storage, and widespread usage of electric vehicles will require fundamental changes in methods and tools for the operation and planning of the power grid. The resulting new dynamic and stochastic behaviors will demand the inclusion of more complexity in modeling the power grid. Solving such complex models in the traditional computing environment will be a major challenge. Along with the increasing complexity of power system models, the increasing complexity of smart grid data further adds to the prevailing challenges. In this environment, the myriad of smart sensors and meters in the power grid increase by multiple orders of magnitude, so do the volume and speed of the data. The information infrastructure will need to drastically change to support the exchange of enormous amounts of data as smart grid applications will need the capability to collect, assimilate, analyze and process the data, to meet real-time grid functions. High performance computing (HPC) holds the promise to enhance these functions, but it is a great resource that has not been fully explored and adopted for the power grid domain.

Huang, Zhenyu Henry↗

Analytic Estimation Method of Forced Oscillation Amplitude Under Stochastic Continuous Disturbances

This paper proposes an analytic method for the amplitude estimation of the forced oscillation under stochastic continuous disturbances (SCDs). There is considerable interest in the integration of intermittent renewable energy resources into a power system, which leads to the power system in an environment with SCDs. Thus, the forced oscillation issues under SCDs are of concern. In this paper, the SCDs are described as continuous-time stochastic processes, and then the systems under SCDs are modeled by stochastic differential algebraic equations. Furthermore, by employing stochastic theory, an efficient analytic method for calculating the statistics of system states during the forced oscillation is proposed. Moreover, a novel forced oscillation phenomenon, which presents system states oscillate with stationary distributions under SCDs, is clearly characterized and theoretically explained. Based on the proposed analytic method, a scheme is put forth to estimate amplitudes of system states during forced oscillation under SCDs. Finally, compared to Monte Carlo simulation, the proposed scheme has two significant advantages. First, the proposed scheme offers a fast and effective solution for engineering applications. Second, the impact mechanism of SCDs on forced oscillation in power system is clearer, by the proposed scheme.

42 ENGINEERING↗

A Framework for Robust Long-Term Voltage Stability of Distribution Systems

Power injection uncertainties in distribution power grids, which are mostly induced by aggressive introduction of intermittent renewable sources, may drive the system away from normal operating regimes and potentially lead to the loss of long-term voltage stability (LTVS). Naturally, there is an ever increasing need for a tool for assessing the LTVS of a distribution system. This paper presents a fast and reliable tool for constructing inner approximations of LTVS regions in multidimensional injection space such that every point in our constructed region is guaranteed to be solvable. Numerical simulations demonstrate that our approach outperforms all existing inner approximation methods in most cases. Furthermore, the constructed regions are shown to cover substantial fractions of the true voltage stability region. In conclusion, the paper will later discuss a number of important applications of the proposed technique, including fast screening for viable injection changes, constructing an effective solvability index and rigorously certified loadability limits.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quantitative Metrics for Grid Resilience Evaluation and Optimization

Power system resilience has become a critical topic in recent years because of the increasing trend of extreme events and the growing integration of intermittent renewable energy sources. To enhance grid resilience against high-impact, low-frequency events, two questions should be answered: how to quantify the resilience of a given grid and how to incorporate the quantification into power system planning, operation, and restoration. Here this paper develops a new set of quantitative metrics with clear physical interpretation to comprehensively evaluate power system resilience. Using microgrids as an example, an event-based corrective scheduling (ECS) model and an online model predictive control (OMPC) model are developed to integrate the proposed quantitative resilience metrics into power system optimization models for resilience enhancement. The ECS model employs extreme event data to investigate the optimal restoration solution and to help microgrid operators prepare to respond to similar events. The OMPC model provides online decision-making support for operators to handle ongoing outages in the most resilient fashion. The effectiveness and superiority of the proposed quantitative resilience metrics and the resilience enhancement models are demonstrated through simulations and comparative studies on an IEEE test feeder and a real distribution feeder in Southern California.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling Hybrid Nuclear Systems With Chilled-Water Storage

Air-conditioning loads during the warmer months of the year are large contributors to an increase in the daily peak electrical demand. Traditionally, utility companies boost output to meet daily cooling load spikes, often using expensive and polluting fossil fuel plants to match the demand. Likewise, heating, ventilation, and air conditioning (HVAC) system components must be sized to meet these peak cooling loads. However, the use of a properly sized stratified chilled-water storage system in conjunction with conventional HVAC system components can shift daily energy peaks from cooling loads to off-peak hours. This process is examined in light of the recent development of small modular nuclear reactors (SMRs). In this paper, primary components of an air-conditioning system with a stratified chilled-water storage tank were modeled in FORTRAN 95. A basic chiller operation criterion was employed. Simulation results confirmed earlier work that the air-conditioning system with thermal energy storage (TES) capabilities not only reduced daily peaks in energy demand due to facility cooling loads but also shifted the energy demand from on-peak to off-peak hours, thereby creating a more flattened total electricity demand profile. Thus, coupling chilled-water storage-supplemented HVAC systems to SMRs is appealing because of the decrease in necessary reactor power cycling, and subsequently reduced associated thermal stresses in reactor system materials, to meet daily fluctuations in cooling demand. Finally and also, such a system can be used as a thermal sink during reactor transients or a buffer due to renewable intermittency in a nuclear hybrid energy system (NHES).

25 ENERGY STORAGE↗

Preliminary Component Design and Cost Estimation of a Novel Electric-Thermal Energy Storage System Using Solid Particles

Energy storage will become indispensable to complement the uncertainty of intermittent renewable resources and to firm the electricity supply as renewable power generation becomes the mainstream new-built energy source and fossil fuel power plants are phased out to meet carbon-neutral utility targets. Current energy storage methods based on pumped storage hydropower or batteries have many limitations. Thermal energy storage (TES) has unique advantages in scale and siting flexibility to provide grid-scale storage capacity. A particle-based TES system is projected to have promising cost and performance characteristics to meet the future growing energy storage needs. This paper introduces the system and components required for particle TES to become technically and economically competitive. The system integrates electric particle heaters, particle TES within insulated concrete silos, and an efficient air-Brayton combined-cycle power system to provide power for storage durations up to several days via low-cost, high-performance storage cycles. Design specifications and cost estimation of major components in a commercial-scale system are presented in this paper. A techno-economic analysis based on preliminary component designs and performance indicates that particle TES integrated with an air-Brayton combined-cycle power system has a path to achieve the targeted levelized cost of storage of 5 ¢/kWh-cycle at a round-trip efficiency of 50% when taking low-cost energy-specific components and leveraging basic assets from existing thermal power plants. The cost model provides insights for further development and economic potentials for long-duration energy storage.

14 SOLAR ENERGY↗

Zinc–air batteries in neutral/near-neutral electrolytes

The need to fully utilize intermittent renewable energy and have energy security, large-scale batteries are necessary. The aqueous zinc–air battery (ZAB) is a promising potential candidate for its safety, low-cost, and theoretical capacity. This research on ZAB mainly focused on alkaline electrolytes. These are favored for their conductivity, but greatly reduce the stability of the battery by zinc corrosion from the hydrogen evolution reaction (HER), dendrite formation, and carbonate formation. To address these issues, recently neutral and near-neutral electrolytes have been applied to aqueous ZAB to suppress HER, dendrite formation, and minimize carbonate formation. These include the use of chloride-based, potassium nitrate, aqueous organic, solid-state electrolytes supplemented with additives to improve the performance and stability. This field is still young with significant opportunities available for research.

25 ENERGY STORAGE↗

Ionomer Optimization for Hydroxide-Exchange-Membrane Water Electrolyzers Operated with Distilled Water: A Modeling Study

The hydroxide-exchange-membrane water electrolyzer (HEMWE) is a promising means to store intermittent renewable energy in the form of hydrogen chemical energy. The hydroxide-exchange ionomer (HEI) in the gas-evolving electrodes and the hydroxide-exchange membrane (HEM) are key components of HEMWE. In this work, we simulate the cell and examine explicitly the impact of HEI and HEM properties with a focus on improving HEMWE performance when operated with distilled water ( i.e ., no supporting electrolyte). The tradeoff between the ionic conductivity gain and electrochemically active surface area (ECSA) loss is studied. For a constant catalyst loading, distributing more catalyst next to the HEM or making thinner but denser catalyst layer is beneficial for HEMWE performance. The results demonstrate that a higher water diffusion coefficient is desired for HEM to supply reactant water to the cathode. In contrast, a lower water diffusion coefficient is preferred for the cathode HEI to retain the water in the regions with high reaction rates. Overall, the findings provide important insights to optimizing HEI/HEM materials for improved HEMWE performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrolyte Study for High-Nickel LiNi 0.9 Mn 0.05 Co 0.05 O 2 Cathodes

With an increasing demand for intermittent renewable energy and electric vehicles, it is imperative to develop lithium-ion batteries with Earth-abundant cathode materials. Cobalt (Co) is preferred to be kept at a minimum because of its high cost and limited mining options, yet it has played an essential role in the high-performance transition metal oxides (TMOs). Herein, we report work from Argonne National Laboratory, conducted under the U.S. DoE's Vehicle Technologies Office, Deep Dive consortium on Next-Generation Cathodes, to optimize electrolytes for LiNi 0.9 Mn 0.05 Co 0.05 O 2 . LiNi 0.9 Mn 0.05 Co 0.05 O 2 is a high-Ni TMO benchmark as it outperforms most other TMOs under standard cycling conditions. In this study, we use the figure-of-merit approach to optimize electrolytes for this novel cathode material. Dual-salt carbonate electrolytes containing lithium difluorooxyphosphate and hexafluorophosphates were found to be the best for capacity retention and slowing the impedance rise. Importantly, transition metal dissolution and lithium inventory losses in the solid electrolyte interface were found to be the major causes for capacity fade.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exploring the Effectiveness of Carbon Cloth Electrodes for All-Vanadium Redox Flow Batteries

Vanadium redox flow batteries (VRFBs) have shown to be a promising technology for integrating intermittent renewable energy sources into the existing electrical grid. Incorporation of carbon cloth electrodes into VRFB is an area of interest for their enhanced electrochemical performance, however, issues with performance degradation throughout the duration of the experiment persist. This study investigates the performance evolution of carbon cloth electrodes during VRFB cycling to build a hypothesis on possible reasons for the declining performance. Electrochemical impedance spectroscopy and polarization curve measurements are used in conjunction to monitor the electrode degradation and shed light on the effectiveness of carbon cloth electrodes during extended cycling experiments. A detailed investigation into the structure of the carbon cloth electrodes before and after cycling, via several material characterization tests, provides insight needed to determine an explanation for the increasing resistance. The structural integrity and surface morphology of the carbon cloth electrodes are evaluated to compare the electrode before and after cycling, displaying any changes to the electrode due to cycling. Durability of hydrophilicity during RFB cycling is found to be a key feature for future carbon cloth electrode design efforts.

25 ENERGY STORAGE↗

Binder-Coated Carbon Cloth Electrodes for All-Vanadium Redox Flow Batteries

Vanadium redox flow batteries (VRFBs) are a promising solution for integrating intermittent renewable energy sources into the existing power grid. However, enhancing the electrochemical performance of VRFBs is critical for their widespread adoption in grid-scale energy storage. This study investigates the impact of adding a porous binder to a carbon-cloth electrode, with a focus on optimizing thermal activation conditions. The electrochemical performance of the binder-coated electrodes compared to uncoated electrodes is evaluated through electrochemical impedance spectroscopy, polarization curve measurements, and charge-discharge cycling. The surface morphology and structural integrity of the binder-coated electrodes at each activation stage are examined using various material characterization techniques to assess the effects of thermal activation. The results are benchmarked against the experiments using non-coated electrodes to determine the performance improvements offered by the binder coating. Notably, the study reveals that binder-coated electrodes exhibit significantly lower resistance and improved efficiency compared to their uncoated counterparts, with optimal activation conditions enhancing performance metrics crucial for VRFB applications. These findings provide valuable insights for further optimizing electrode design and activation strategies, advancing the development of more efficient VRFB systems for large-scale energy storage.

Caiado, Ashley A.↗

(Invited) Virtual Analysis of Gas-Diffusion-Electrode CO 2 Electrolyzers

The electrochemical reduction of CO 2 (CO 2 R) to value-added products is an attractive technology for tackling the rising atmospheric CO 2 levels and storing intermittent renewable energy into chemical bonds. Fundamental understanding of CO 2 R has progressed significantly in recent years and is critical in the development of CO 2 R to liquid-fuel electrolyzers, where gas-diffusion electrodes (GDEs) have been shown to be key enabling architectures. Various designs have been proposed and studied in the literature to enhance overall selectivity, rates, and maximize the conversion of CO 2 , the latter of which is only now being recognized as a critical issue. In this respect, there is a need to explore the governing phenomena inherent in these architectures to enable optimization. Mathematical modeling is ideally suited to tackle and explore these multiphysics interactions and provide virtual design analysis. In this talk, we discuss modeling methodologies and physics inherent in these devices and present our recent modeling of GDEs for CO 2 reduction. We specifically examine the impacts of multiphase flow and related phenomena on overall cell performance. We then explore the performance and limitations of various cell designs guided by simulation results and examine potential methods for improving water management and tuning catalyst selectivity including the use of different anion-exchange and bipolar membranes. Finally, we discuss the disparities in local environments between aqueous and GDE devices and propose strategies to reduce the gap in knowledge between the two systems.

42 ENGINEERING↗

Mathematical Modeling of Hydroxide-Exchange-Membrane Water Electrolyzer

Water electrolyzers can transform intermittent renewable energy like solar energy and wind energy into the chemical energy of hydrogen with zero greenhouse-gas emissions. The hydroxide-exchange membrane electrolyzer (HEME) combines the capability to produce pressurized hydrogen with the advantage of being able to use low or non-platinum group metal (PGM) electrocatalysts in the alkaline environment.1 Hydroxide salts, for example, KOH, are added to the HEME water feed on both anode and cathode to improve its performance. However, the specific mechanism of performance improvement still needs to be further understood. In addition, at high current densities, bubble evolution can result in mass-transport limitations, a less well studied phenomena. Mathematical modeling is ideal to explore these issues as it is cost and time efficient and can deconvolute the physics, processes, and observed phenomena and study the applied-voltage breakdown. In this work, we extend our previously developed 1D two-phase continuum model2 to study the varies processes in the HEME and provide insights on performance optimizations. First, the oxygen evolution reaction (OER) and hydrogen evolution reaction (HER) kinetics at different hydroxide concentrations have been studied by rotating disk electrodes (RDE) and implemented in the model. Then, the model is calibrated and validated against experimental HEME polarization curves for different KOH concentrations as a liquid electrolyte. The model clearly shows a performance increase with increasing KOH concentrations, which is consistent with the experimental results. The reduced ohmic resistance and increased electrochemical active surface area (ECSA) are the two main reasons for performance increase. The large amount of hydroxide in the liquid electrolyte not only helps to distribute the reactant hydroxide throughout the catalyst layer (CL), which reduces ohmic loss, but also enables reaction at the interface between the liquid electrolyte and electrocatalyst, which increases the ECSA. Applied-voltage breakdown demonstrates that the electrolyzer performance is dominated by anode kinetics and ohmic loss. A comparison with the DI water feed shows a more uniform current distribution in the anode CL when KOH is added, which indicates a higher utilization of the CL. Second, we present modeling on the effects of bubble coverage. As gas evolves, part of the ECSA is minimized due to bubble coverage. To account for this effect, an empirical relationship between the fractional bubble coverage and the current density is implemented in the model.3 The model shows this bubble coverage effect is more pronounced at large current densities with DI water feed. Acknowledgements This work was funded under the HydroGEN Consortium by the Energy Efficiency and Renewable Energy, Hydrogen and Fuel Cell Technologies Office, of the U. S. Department of Energy under contract number DE-AC02-05CH11231. References R. Abbasi, B. P. Setzler, S. Lin, J. Wang, Y. Zhao, H. Xu, B. Pivovar, B. Tian, X. Chen, G. Wu and Y. Yan, 31, 1805876 (2019). L. N. Stanislaw, M. R. Gerhardt and A. Z. Weber, ECS Transactions, 92, 767 (2019). H. Vogt and R. J. Balzer, Electrochimica Acta, 50, 2073 (2005).

Liu, Jiangjin↗

Virtual Analysis of Gas-Diffusion-Electrode CO 2 Electrolyzers

The electrochemical reduction of CO 2 (CO2R) to value-added products is an attractive technology for tackling the rising atmospheric CO 2 levels and storing intermittent renewable energy into chemical bonds. Fundamental understanding of CO 2 R has progressed significantly in recent years and is critical in the development of CO 2 R to liquid-fuel electrolyzers, where gas-diffusion electrodes (GDEs) have been shown to be key enabling architectures. Various designs have been proposed and studied in the literature to enhance overall selectivity, rates, and maximize the conversion of CO 2 , the latter of which is only now being recognized as a critical issue. In this respect, there is a need to explore the governing phenomena inherent in these architectures to enable optimization. Mathematical modeling is ideally suited to tackle and explore these multiphysics interactions and provide virtual design analysis. In this talk, we discuss modeling methodologies and physics inherent in these devices and present our recent modeling of GDEs for CO 2 reduction. Here, we specifically examine the impacts of multiphase flow and related phenomena on overall cell performance. We then explore the performance and limitations of various cell designs guided by simulation results and examine potential methods for improving water management and tuning catalyst selectivity including the use of different anion-exchange and bipolar membranes. Finally, we discuss the disparities in local environments between aqueous and GDE devices and propose strategies to reduce the gap in knowledge between the two systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

GRAF-Plan for Vietnam

Evaluates the reserve requirements for power system balancing areas based on variability and uncertainty of load as well as wind and solar generation scenarios. The tool uses minute‐by‐minute site‐specific generation and load information, as well as information from generation and load forecasting algorithms used in the balancing areas. The Balancing‐Plan Tool can be used directly by utility planners and operators to aid in the integration of intermittent renewable resources. The tool provides reserve requirements of various kinds, such as day‐ahead, load following and regulation, as well as estimates the capacity of the generation fleet to provide the require reserves.

Campbell, Allison↗

Dynamic Earth Energy Storage: Terawatt-Year, Grid-Scale Energy Storage using Planet Earth as a Thermal Battery (GeoTES): Seedling Project Final Report

Grid-scale energy storage has been identified as a needed technology to support the continued build-out of intermittent renewable energy resources. As of April 2017, the U.S. had approximately 24.2 GW of energy storage on line, compared to 1,081 GW of installed generation capacity (Litynski et al. 2006, Hellstrom 2003). This represents a large shortfall of the storage needed to stabilize the U.S. grids with the rising penetration of renewable energy. Our team proposed to address this shortfall through the storage of excess energy as geothermal brine in deep geologic formations. This concept, known as geologic thermal energy storage (GeoTES), relies on the storage of thermal energy in geologic formations for recovery and use in large-scale direct use geothermal applications. As such, GeoTES has the potential to play a significant role in meeting the energy storage shortfall in the coming decades by assisting with peak demand ramping, easing stress on transmission, providing regional storage to support sustainable direct use geothermal applications, and providing a variety of grid stabilization benefits due to renewable outages or inaccurate forecasting and rotor stability.

15 GEOTHERMAL ENERGY↗

Preparation of 1,3-Dihydroxyphenazine

The ability to effectively store energy produced by intermittent renewable sources is a critical challenge for chemists and materials scientists. Redox flow batteries (RFB), which generate current by the flow of electrons between dissolved redox active compounds in separate solutions, are envisioned as a method to store renewable energy at the electrical grid scale. The best known examples of RFBs are driven by redox active metal or main group complexes. Within the past decade, redox active organic molecules have begun to be used in the construction of RFBs with high cell potential and cycle stability, at economical price points. Of particular interest are substituted dihydroxy phenazines, a class of heterocycles, that have recently been used as an anolyte for aqueous organic RFBs. Recent work indicates that different regioisomers of dihydroxyphenazine show dramatically different solubility and stability under electrochemical cycling conditions. Of particular interest was 1,3-dihydroxyphenazine (1,3-DHP), which showed greater than 1.5 M solubility in 2M KOH and excellent electrochemical stability. Current methods of producing 1,3-DHP, however, are low yielding and cumbersome. In the article proposal that follows, we offer an improved method of producing 1,3-DHP at high purity and moderate yield. The method detailed below was used by the Materials Engineering Research Facility (MERF) at Argonne National Lab to deliver more than 1.5 kg of this compound for use in the construction of aqueous organic RFBs.

Dzwiniel, Trevor [Argonne National Laboratory (ANL↗

Developing and Evaluating Metrics for Demand Flexibility in Buildings: Comparing Simulations and Field Data

Building demand flexibility (DF) has attracted significant attention in recent years among researchers, technology developers and control companies, aggregators, utilities, and many others. There are numerous challenges with today’s electricity systems such as managing peak demand capacity and integrating variable renewables into the grid. Flexible building loads can provide various grid services to help reduce electricity costs, smooth out renewables intermittency and balance supply and demand. Recognizing this, the US DOE is leading the Grid-interactive Efficient Buildings (GEB) initiative which includes research to evaluate the potential, availability and timing of flexible loads. In this paper we present load shed metrics for three building types – medium office, large office and retail store – and compare prototype simulation results with measured data from 12 actual buildings that participated in hot summertime utility demand response (DR) events. The DR strategies included varying zone temperature and reducing light levels. The magnitude of a key DF metric, “demand decrease intensity” (or “shed intensity”) (W/ft2), between the simulation results and field data are similar (14-32% differences) for both mean and median values, though the field data show much larger variation among DR events. The coefficient p-values from linear regression model tests showed that outside air temperature is a significant variable for the whole building shed intensity when the resetting zone temperature strategy is deployed. These findings support the concept of using prototype building simulation to estimate building DF and expanding future simulation research to additional building types and climate zones.

Liu, Jingjing↗