At least 163 records · Page 9

Distribution System Resilience Assessment Considering PV Vulnerabilities for Hurricane Events

Distribution networks are increasingly vulnerable to damage and outages from extreme weather events. The integration of solar photovoltaics (PVs) further complicates resilience analysis due to its weather-dependent nature. However, limited research has examined the impacts of weather on PVs under severe events like hurricanes. This paper proposes a probabilistic framework to assess distribution system resilience considering PV vulnerabilities during hurricanes. The framework incorporates (i) a spatiotemporal fragility model to evaluate failure probabilities for distribution lines and PVs, and (ii) resilience indices at both system and component levels. The approach offers valuable insights into the resilience of modern distribution grids under extreme weather conditions. Numerical results on the unbalanced IEEE 123-bus test system validate the effectiveness of the framework.

Vahedi, Soroush [University of Connecticut, Storrs↗

ARCADE Technical Pathway and Industry Impact

The Advanced Reactor Cyber Analysis and Development Environment (ARCADE) simplifies the evaluation and assessment of robustness factor and cyber resilience that support secure-by-design for advanced reactor nuclear power plants. In this manner, ARCADE supports risk-informed performance based (RIPB) evaluations of cybersecurity through its integration of plant physics with high-fidelity emulations of control systems. This cross domain approach enables comprehensive analysis of control system sensitivities, cyber-attack scenarios, and their consequences. ARCADE has been custom developed to meet the demands identified in Tier 1 of the Tiered Cyber Analysis (TCA) as outlined in NRC Draft Regulation Guide (RG) 5.96, which provides a RIPB cybersecurity approach for new reactors.

97 MATHEMATICS AND COMPUTING↗

Powered By ERAD [Slides]

Energy Resilience Analysis for Distribution Power System (ERAD) is a free, open-source Python toolkit for estimating the energy and service impacts of hazards like earthquakes and flooding. It uses a graph-based approach to capture high resolution connectivity among the grid, critical services, and customers and rapidly compute household level metrics and aggregated statistics across large distribution systems. It uses asset fragility curves that relate hazard severity to survival probability for power system equipment including cables, transformers, substations, etc. The tool is designed to be modular and extensible, allowing it to interface with third-party hazard simulators and integrate into broader resilience analysis workflows. ERAD enables researchers, students, communities, distribution utilities, and other stakeholders to understand hazard impacts and evaluate the effectiveness of different programs to improve energy resilience. The webinar was hosted by NLR researcher Aadil Latif.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Remote Hardware-in-the-Loop Approach for Microgrid Controller Evaluation

Utilities have been installing microgrids because of the increased resilience and reliability advantages they may provide to the distribution system. A microgrid controller is a critical component in microgrids. It is of great benefit to derisk the installation of microgrid controllers before field deployment. Hardware-in-the-loop (HIL) testing is used by controller developers and utilities to evaluate the controllers under stressful conditions. In this work, a microgrid control function developed by the Synchrophasor Grid Monitoring and Automation (SyGMA) laboratory at the University of California, San Diego is tested in a remote HIL (RHIL) setup. The digital real-time simulation of the detailed microgrid system was operated at the National Renewable Energy Laboratory's Energy Systems Integration Facility. Under such RHIL setup, successful controller operation is contingent on understanding and characterizing the communications channel and in particular network latencies. The novelty of this paper is the proposed use of a RHIL setup that leverages existing power system communications protocols to evaluate the controller in conjunction with the simulation capabilities of a remote facility. The work presented here will provide the complete setup of the HIL evaluation platform, the details of the communications protocols used by the setup for data transfer between the two organizations, test cases developed to evaluate the controller, and the results from the experiments.

controller hardware-in-the-loop↗

Remote Hardware-in-the-Loop Approach for Microgrid Controller Evaluation

Utilities have been installing microgrids because of the increased resilience and reliability advantages they may provide to the distribution system. A microgrid controller is a critical component in microgrids. It is of great benefit to derisk the installation of microgrid controllers before field deployment. Hardware-in-the-loop (HIL) testing is used by controller developers and utilities to evaluate the controllers under stressful conditions. In this work, a microgrid control function developed by the Synchrophasor Grid Monitoring and Automation (SyGMA) laboratory at the University of California, San Diego is tested in a remote HIL (RHIL) setup. The digital real-time simulation of the detailed microgrid system was operated at the National Renewable Energy Laboratory's Energy Systems Integration Facility. Under such RHIL setup, successful controller operation is contingent on understanding and characterizing the communications channel and in particular network latencies. The novelty of this paper is the proposed use of a RHIL setup that leverages existing power system communications protocols to evaluate the controller in conjunction with the simulation capabilities of a remote facility. The work presented here will provide the complete setup of the HIL evaluation platform, the details of the communications protocols used by the setup for data transfer between the two organizations, test cases developed to evaluate the controller, and the results from the experiments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Tool for the Risk-Informed Management of Critical Mission Resilience

We describe a methodology and tool for the risk-informed management and planning of mission resilience. By mapping concepts of resilience onto the elements of a streamlined risk model we are able to tap the substantial portfolio of established risk concepts to provide rapid insights in the evaluation and high-level screening of prospective resilience enhancement measures. This provides a risk-informed, levelized basis for the comparison of disparate resilience solutions and the means of establishing preferences. The methodology begins with identification of critical missions met by a site, and establishment of the supporting physical assets. Scenarios that would result in failure of these assets are systematically identified. Each scenario comprises three elements: realization of a hazard or threat resulting in loss of resources (the current focus being on power, natural gas, and water) to the asset, failure of measures in place to protect the asset against those losses, and realization of the consequent impacts. These scenarios are quantified in terms of their probabilities of occurrence and the magnitude of the resultant consequences (mission outage time), allowing risk-prioritization to focus resilience enhancement considerations. What-If? analyses are conducted through adjusting elements of the risk calculation to reflect the deployment of prospective resilience measures, by which means the efficacies of each of those measures can be compared using common risk metrics across diverse resilience strategies. This paper will also describe the insights from example applications.

resilience, risk, risk assesment, energy, water↗

Assessing Resilience in Lane Detection Methods: Infrastructure-Based Sensors and Traditional Approaches for Autonomous Vehicles

Traditional autonomous vehicle perception subsystems that use onboard sensors have the drawbacks of high computational load and data duplication. Infrastructure-based sensors, which can provide high quality information without the computational burden and data duplication, are an alternative to traditional autonomous vehicle perception subsystems. However, these technologies are still in the early stages of development and have not been extensively evaluated for lane detection system performance. Therefore, there is a lack of quantitative data on their performance relative to traditional perception methods, especially during hazardous scenarios, such as lane line occlusion, sensor failure, and environmental obstructions. We address this need by evaluating the influence of hazards on the resilience of three different lane detection methods in simulation: (1) traditional camera detection using a U-Net algorithm, (2) radar detections using infrastructure-based radar retro-reflectors (RRs), and (3) direct communication of lane line information using chip-enabled raised pavement markers (CERPMs). The performance of each of these methods is assessed using resilience engineering metrics by simulating the individual methods for each sensor technology’s response to related hazards in the CARLA simulator. Using simulation techniques to replicate these methods and hazards acquires extensive datasets without lengthy time investments. Specifically, the resilience triangle was used to quantitatively measure the resilience of the lane detection system to obtain unique insights into each of the three lane detection methods; notably the infrastructure-based CERPMs and RRs had high resistance to hazards and were not as easily affected as the vision-based U-Net. However, while U-Net was able to recover the fastest from the disruption as compared to the other two methods, it also had the most performance loss. Overall, this study demonstrates that while infrastructure-based lane keeping technologies are still in early development, they have great potential as alternatives to traditional ones.

Patil, Pritesh↗

DISCOVR: Development of Integrated Screening, Cultivar Optimization, and Verification Research

The DISCOVR consortium has developed and is applying an integrated platform and workflow for standardized, deep characterization of highly productive and resilient microalgae strains. New strains are screened using three consecutive tiers in a conceptual down-selection funnel to arrive at the most promising strains. At tier I, strains are screened on gradient incubators to determine their temperature and salinity tolerance range, and to evaluate their resistance to infectious agents (e.g., chytrids). At tier II, the strains’ winter and summer season biomass productivities are quantified in Laboratory Environmental Algae Pond Simulator (LEAPS) photobioreactors, and biomass composition is determined under N-replete and N-deplete conditions. At tier III, the best winter and summer season strains are evaluated in indoor crash ponds to determine their resilience to induced infections, and strains are tested in outdoor raceway ponds to confirm high biomass productivity and culture stability. The top strains are then evaluated in seasonal SOT outdoor pond culture trials at AzCATI, the dedicated Department of Energy SOT (State of Technology) testbed. Additional research is carried out on evaluating growth promoting molecules, reducing the impact of oxygen inhibition, optimizing pond operational conditions, measuring compositional shift dynamics, developing integrated pest management strategies, analysing culture health using 96 well-plate tools, implementing spectroradiometric monitoring and using machine learning to predict culture crashes.

Huesemann, Michael H↗

Defining weather scenarios for simulation-based assessment of thermal resilience of buildings under current and future climates: A case study in Brazil

In response to increasingly severe weather conditions, optimization of building performance and investment provides an opportunity to consider co-benefits of thermal resilience during energy efficiency retrofits. This work aims to assess thermal resilience of buildings using building performance simulation to evaluate the indoor overheating risk under nine weather scenarios, considering historical (2010s), mid-term future (2050s), and long-term future (2090s) typical meteorological years, and heat wave years. Such an analysis is based on resilience profiles that combine six integrated indicators. A case study with a district of 92 buildings in Brazil was conducted, and a combination of strategies to improve thermal resilience was identified. Results reflect the necessity of planning for resilience in the context of climate change. This is because strategies recommended under current conditions might not be ideal in the future. Therefore, an adaptable design should be prioritized. Cooling energy consumption could increase by 48 % by the 2050s, while excessive overheating issues could reach 37 % of the buildings. Simple passive strategies can significantly reduce the heat stress. A comprehensive thermal resilience analysis should ultimately be accompanied by a thorough reflection on the stakeholders’ objectives, available resources, and planning horizon, as well as the risks assumed for not being resilient.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

WaterTAP3 (The Water Technoeconomic Assessment Pipe-Parity Platform)

The Water Technoeconomic Assessment Pipe-Parity Platform (WaterTAP3) was developed under the National Alliance for Water Innovation (NAWI) to facilitate consistent technoeconomic assessments of desalination treatment trains. The WaterTAP3 is an analytically robust modeling tool that can be used to evaluate water technology cost, energy, environmental, and resiliency tradeoffs across different water sources, sectors, and scales. The model simulates steady-state water treatment train performance and costs including flow and constituent mass balance across unit processes, based on source water conditions, configurations of treatment technologies, and system-level techno-economic assumptions. Users can build a new treatment train by connecting any number of unit processes, specific for their context and system, or selecting a train from the treatment train library. The model contains various technical and cost parameter options for a range of treatment processes and a library of influent water quality characteristics for a variety of source waters and case studies. Users can customize water quality parameters to evaluate the technology performance in their context. The model can be set up for different assessment needs including simulation, optimization, and uncertainty and sensitivity analyses. The results from WaterTAP3 can help identify trade-offs among the different system performance metrics, with insight on how particular technologies or systems promote pipe-parity. The flexibility and comprehensive scope of the tool makes it a promising solution to industry-wide water technoeconomic evaluations, leading to more informed water investment decisions and technologies. As a user-friendly, open-source platform, WaterTAP3 can be used by industry, academia, policymakers, planners, and those with or without extensive analytical experience.

Miara, Ariel↗

Water Technoeconomic Assessment Pipe-Parity Platform (WaterTAP3)

The Water Technoeconomic Assessment Pipe-Parity Platform (WaterTAP3) was developed under the National Alliance for Water Innovation (NAWI) to facilitate consistent technoeconomic assessments of desalination treatment trains. The WaterTAP3 is an analytically robust modeling tool that can be used to evaluate water technology cost, energy, environmental, and resiliency tradeoffs across different water sources, sectors, and scales. The model simulates steady-state water treatment train performance and costs including flow and constituent mass balance across unit processes, based on source water conditions, configurations of treatment technologies, and system-level techno-economic assumptions. Users can build a new treatment train by connecting any number of unit processes, specific for their context and system, or selecting a train from the treatment train library. The model contains various technical and cost parameter options for a range of treatment processes and a library of influent water quality characteristics for a variety of source waters and case studies. Users can customize water quality parameters to evaluate the technology performance in their context. The model can be set up for different assessment needs including simulation, optimization, and uncertainty and sensitivity analyses. The results from WaterTAP3 can help identify trade-offs among the different system performance metrics, with insight on how particular technologies or systems promote pipe-parity. The flexibility and comprehensive scope of the tool makes it a promising solution to industry-wide water technoeconomic evaluations, leading to more informed water investment decisions and technologies. As a user-friendly, open-source platform, WaterTAP3 can be used by industry, academia, policymakers, planners, and those with or without extensive analytical experience. A publicly available graphical user interface is currently under development.

Miara, Ariel↗

Framework for Assessing Impact of Wave-Powered Desalination on Resilience of Coastal Communities

Coastal communities face unique challenges in maintaining continuous service from critical infrastructure. This research advances capabilities for evaluating the impact of using wave energy to desalinate water on the resilience of coastal communities. The study focuses on the feasibility of using wave energy conversion to provide drinking water to communities in need and applying resilience metrics to quantify its impact on the community. To assess the feasibility of wave-powered desalination, this research couples the open-source software Wave Energy Converter SIMulator (WEC-Sim) and Water Network Tool for Resilience (WNTR). This research explores variations in both the wave resource (location, seasonality, and duration) and the ability to maintain drinking water service during a disruption scenario by applying the simulation framework to three case studies, which are based on communities in Puerto Rico. The simulation framework provides a contextualized assessment of the ability of wave-powered desalination to improve the resilience of coastal communities, which can serve as a methodology for future studies seeking the integration of wave-powered desalination with water distribution systems.

16 TIDAL AND WAVE POWER↗

Dynamics and Control of Microgrids as a Resiliency Source

Microgrids can be operated in a utility-connected mode with the neighboring distribution system or in an islanded mode in separation with the distribution system. As the major disasters occur more and more often, islanded microgrid is proposed as a possible solution to serve essential loads until the utility service is restored. This paper evaluates the feasibility of using microgrids as a resiliency resource by a field test. A control scheme, integrating droop control and feedback control, is applied on a modified IEEE 13-node test feeders. The simulation results validate the proposed control scheme and the transient stability

Lee, Lung-An↗

Preventive Power Outage Estimation Based on a Novel Scenario Clustering Strategy

The increasing occurrence of extreme weather events is challenging power grid operation. For extreme weather events, the system operator is responsible for estimating the power outages and scheduling the restoration resources. This paper proposes an outage evaluation framework to identify the possible unserved load profiles, vulnerable areas, and mobile energy adequacy. The outputs of an outage prediction model tool are used to generate numerous faulted line scenarios. Next, each scenario's nodal unserved load profile is obtained by solving a three-phase restoration model that considers repair crews and mobile energy resources (MERs). Then, a novel scenario clustering strategy is developed to cluster the unserved load profiles into multiple representative profiles which the system operator can focus on. Finally, case studies on a distribution system evaluate the damage caused by an extreme weather event and verify the effectiveness of the proposed scenario clustering strategy.

MATHEMATICS AND COMPUTING,POWER TRANSMISSION AND D↗

Irrigation Modernization Task 4: Accelerating Energy Solutions (FY2022 Final Report)

This report offers insights on energy solutions for irrigation modernization that serve the needs of farmers as well as residents and industry in the local community. Solutions are found in the irrigation districts where local generation from renewable energy sources – solar, hydro, and wind – can be combined with energy storage and customer loads. These combined resources configured in microgrids can lower costs during peak loads and provide resiliency by maintaining electricity supply during outages. The goal of this project, as stated in the FY2022 AOP, is to promote realization of energy solutions that are tailored to physical location, community, infrastructure, and energy value streams. Further, it is to develop examples of how to increase value of, and overcome barriers to, energy solutions in the context of irrigation modernization. In pursuit of that goal, the project looked at options for: 1) Reducing the cost of energy consumed in irrigation systems, 2) Increasing the revenue from surplus power generation, and 3) Deploying new power generation configured as part of a local microgrid. Potential solutions to reducing energy costs and increasing surplus power revenue revolve around addressing regulatory and legal constraints tied to how power is purchased by and sold to the irrigator or irrigation district. Some headway was made in identifying barriers and ways to push utilities to be more accommodating to distributed energy sources; however, for the most part, real progress hinges on changes at the regulatory and legislative level. Deployment of local, renewable generation systems can be implemented provided the economics of the project and the location are favorable. In concert with Famers Conservation Alliance and Energy Trust of Oregon, a number of approaches were studied in the past year, including off-grid solar powered pumps, grid-tied community solar projects, and in-conduit canal hydropower systems. Ultimately three viable projects were identified: 1) North Unit Irrigation District/City of Redmond, Oregon Critical Facility Microgrid – offers combined in-conduit hydro and solar power generation. 2) Wallowa County/Joseph, Oregon Irrigation System Upgrades – centered on upgrades to a non-powered dam that will add a turbine as well as in-conduit power in canal feeders downstream. 3) Medford, Oregon Wastewater Treatment Plant Biogas Cogeneration System – centered on building out biogas storage and grid upgrades to power the plant, sell excess power, and provide emergency backup power (supplanting a diesel generator). Each of these projects has characteristics that broaden the understanding of the value of microgrids employing renewable energy to achieve resiliency and net-zero carbon goals. The first two projects are centered on new hydropower systems. Although the Medford project is only tangentially tied to an irrigation district, it was selected for study analysis as it was the only one mature enough (with sufficient data) to complete an analysis within this project year. Thus, we chose to move forward developing a case study, in concert with the Community Water-Power Resilience project, to demonstrate a method for evaluating such projects. Essentially, this case study serves as a template for studies to be carried out next year that more directly involve irrigation system hydropower, e.g., the project at the Wallowa County/Joseph, Oregon Irrigation System. Lastly, it is recognized that the locations and case studies in this report are all located in Oregon. We recognize this as a limitation. While the intent is not to ignore other states or regions, this result is driven by the fact that we have cultivated a collaboration with non-profit entities in Oregon that focus on these topics – Farmers Conservation Alliance and Energy Trust of Oregon. These partners were central to identifying projects that may be good fits for this program. A goal in the coming year is to establish collaboration with entities in other states/regions that, similarly, can connect us to potential projects in their geographic area. The potential benefits from the WPTO’s support for demonstration projects as energy solutions in irrigation districts include: (1) Alternative power supplies for communities and farms using renewable, carbon-free energy resources, (2) Cost savings for electricity for communities and farms, (3) Resiliency of power supplies for critical loads when electricity from the grid is not available, (4) Resiliency of power supplies for critical infrastructure in the event of catastrophic events, and (5) Demonstration of irrigation modernization projects that provide resilience and a reduced carbon footprint to irrigation districts and nearby communities. These deployments can serve as vanguards/archetypes spurring similar projects in other districts and states.

13 HYDRO ENERGY↗

Instrumentation for Assessing DC Electrical Distribution Systems in Buildings

Direct current (DC) distribution systems is emerging as a favorable option over alternating current in buildings due to its energy and non-energy benefits (e.g., efficiency, resilience, safety). However, limited guidelines exist to evaluate the DC electrical distribution infrastructure. This paper aims to fill that gap by detailing our experience with metering a building-level electrical DC distribution system. Our case study is a DC microgrid at the Direct Energy Partners Research & Development facility located in Charlotte, North Carolina. This paper presents our approach, technical challenges, and lessons learned with DC metering and instrumentation.

buildings↗

Urban Energy and Climate: Prospects for a Sustainable Transition

With the continuous migration of people towards metropolitan areas in search of employment, the demands for core services and energy, coupled with an increasing awareness of the impact of climate change, have placed the management and planning of global urban energy under a lot of pressure. Trends toward urban energy service transformations that offer greater affordability, reliability, efficiency and adaptability provide hope for a global sustainable future. At the same time, there are also limits to these transitions, as well as risks involved. For example, on one end of the spectrum, our urban energy future includes land use sprawl, high fossil fuel use, pollution, and unhealthy urban conditions. On the other side of this transition spectrum is more energy choices, and healthier, more livable cities, along with less energy use and fewer greenhouse gas emissions. What the future might hold for transforming the world's cities depends upon an understanding of the risks of current trajectories and the opportunities for and limitations to developing sustainable urban energy systems. This edited volume brings together leading experts on the prospects and challenges of urban energy innovation and on related-economic, social and environmental sustainability transitions. The focus of the volume is on multidisciplinary reviews, research informing technologies and policies for sustainability, and analytical insights addressing rapid urbanization and changes across a diverse typology of global cities. The volume will include an overview of the current state of urban energy systems. It will also document and evaluate urban energy prospects for a sustainable, resilient future.

drivers of change↗

Linking resource availability to pantropical forest canopy resistance and resilience to cyclone disturbance

Statement of purpose: Tropical cyclones are intensifying and occurring at higher latitudes in recent decades, but the mechanisms underpinning the resistance (ability to withstand disturbance-induced change) and resilience (pace of return to pre-disturbance reference values) of tropical forests to cyclones remains largely unexplored at the pantropical scale. We conducted a meta-analysis to investigate the role of soil resource availability (i.e., total soil phosphorus concentration) in mediating site-level forest canopy resistance and resilience to cyclones pan-tropically. We evaluated cyclone-induced and post-cyclone litterfall mass (g/m2/day), phosphorus (P) and nitrogen (N) fluxes (mg/m2/day), as well as concentrations (mg/g) across 73 case studies in Australia, Guadeloupe, Hawaii, Mexico, Puerto Rico, and Taiwan. The dataset zip file includes three data and two metadata files: - The compiled Litterfall Mass Flux data from tropical forests across the globe prior to and after varying tropical cyclone disturbances are provided in Litterfall_Mass.csv. This data file also includes site location, geographical characteristics, elevation, soil phosphorus concentration, geology, and several variables related to each tropical cyclone disturbance. - The compiled Litterfall Nitrogen and Phosphorus Flux data from tropical forests across the globe prior to and after varying tropical cyclone disturbances are provided in Litterfall_Nutrients.csv. This data file also includes site location, geographical characteristics, elevation, soil phosphorus concentration, geology, and several variables related to each tropical cyclone disturbance. - Tropical cyclone track data compiled from HURDAT2 and IBTrACS databases and used as input in the HURRECON model (https://github.com/hurrecon-model/HurreconR) to generate wind data is provided in hurdat2-1851-2019-052520.txt. - The metadata file (Metadata_Meta-analysis_Litterfall-Mass.pdf) has the complete information on each variable included in the Litterfall_Mass.csv dataset, the data sources, and data processing information. - The metadata file (Metadata_Meta-analysis_Litterfall-Nutrients.pdf) has the complete information on each variable included in the Litterfall_Nutrients.csv dataset, the data sources, and data processing information.

54 ENVIRONMENTAL SCIENCES↗