Search NASA⌕ Search

SEARCH · Search NASA

Results for “resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Discovering Hidden Material Properties of MgCl 2 at Atomic Resolution with Structured Temporal Electron Illumination of Picosecond Time Resolution

Abstract A combination of atomic resolution phase contrast electron microscopy and pulsed electron beams reveals pristine properties of MgCl 2 at 1.7 Å resolution that were previously masked by air and beam damage. Both the inter‐ and intra‐layer bonding in pristine MgCl 2 are weak, which leads to uncommonly large local orientation variations that characterize this Ziegler–Natta catalyst support. By delivering electrons with 1–10 ps pulses and ≈160 ps delay times, phonons induced by the electron irradiation in the material are allowed to dissipate before the subsequent delivery of the next electron packet, thus mitigating phonon accumulations. As a result, the total electron dose can be extended by a factor of 80–100 to study genuine material properties at atomic resolution without causing object alterations, which is more effective than reducing the sample temperature. In conditions of minimal damage, beam currents approach femtoamperes with dose rates around 1 eÅ −2 s −1 . Generally, the utilization of pulsed electron beams is introduced herein to access genuine material properties while minimizing beam damage.

Kisielowski, Christian↗

Annotation of DOM metabolomes with an ultrahigh resolution mass spectrometry molecular formula library

Current approaches to analyzing metabolomic data often rely on matching MS/MS fragmentation data to sparse libraries or databases. This approach results in limited identification of features, often with less than 10% of the dataset being annotated. A complementary approach is to assign molecular formula to features based on accurate mass measurements, but the platforms commonly used for metabolomics do not have the needed accuracy or resolving power to do this robustly, particularly for larger molecules. Using our newly modified analysis tool, CoreMS, we generated a library of molecular formula from pooled samples analyzed with LC-21T FT-ICR MS. This library successfully annotated approximately 53.2% of features identified from the exometabolome of marine diatom Phaeodactylum tricornutum – a nearly ten-fold increase over the 5.9% annotation rate achieved using a conventional MS/MS library matching approach. Using this FT-ICR MS library approach, we were able to differentiate differences in the exometabolome of P. tricornutum in iron replete and iron limited conditions, with 668 metabolites being differentially expressed (p < 0.05, 2 x intensity difference) under these conditions. The traditional MS/MS fragmentation-based annotation approach only annotated 61 of these metabolites, while our novel pipeline annotated 450 metabolites and revealed 12 metabolites that were significantly more abundant under low iron conditions. Our results demonstrate the utility of ultrahigh resolution mass spectrometry for generating more comprehensive and confident molecular annotations.

21T-FTICR-MS, CoreMS↗

Spiers Memorial Lecture : Surface-enhanced Raman spectroscopy: from single particle/molecule spectroscopy to ångstrom-scale spatial resolution and femtosecond time resolution

Four decades on, surface-enhanced Raman spectroscopy (SERS) continues to be a vibrant field of research that is growing (approximately) exponentially in scope and applicability while pushing at the ultimate limits of sensitivity, spatial resolution, and time resolution. This introductory paper discusses some aspects related to all four of the themes for this Faraday Discussion. First, the wavelength-scanned SERS excitation spectroscopy (WS-SERES) of single nanosphere oligomers ( viz. , dimers, trimers, etc. ), the distance dependence of SERS, the magnitude of the chemical enhancement mechanism, and the progress toward developing surface-enhanced femtosecond stimulated Raman spectroscopy (SE-FSRS) are discussed. Second, our efforts to develop a continuous, minimally invasive, in vivo glucose sensor based on SERS are highlighted. Third, some aspects of our recent work in single molecule SERS and the translation of that effort to ångstrom-scale spatial resolution in ultrahigh vacuum tip-enhanced Raman spectroscopy (UHV-TERS) and single molecule electrochemistry using electrochemical (EC)-TERS will be presented. Finally, we provide an overview of analytical SERS with our viewpoints on SERS substrates, approaches to address the analyte generality problem ( i.e. target molecules that do not spontaneously adsorb and/or have Raman cross sections <10 -29 cm 2 sr -1 ), SERS for catalysis, and deep UV-SERS.

Chemistry↗

High-resolution photoelectron spectra of the pyrimidine-type nucleobases

High-resolution photoelectron spectra of the gas phase pyrimidine-type nucleobases, thymine, uracil, and cytosine, were collected using synchrotron radiation over the photon energy range 17 ≤ hν ≤ 150 eV. These data provide the highest resolution photoelectron spectra of thymine, uracil, and cytosine published to date. By comparing integrated regions of the energy dependent photoelectron spectra of thymine, the ionization potentials of the first four ionic states of thymine were estimated to be 8.8, 9.8, 10.3, and 10.8 eV. The thymine data also show evidence for low energy shape resonances in three of the outermost valence electronic states. Comparing the uracil spectrum with the thymine spectrum, the four outermost valence electronic states of uracil likely begin at binding energies 9.3, 9.9, 10.5, and 11.0 eV. High-resolution spectra indicate only one tautomeric form of cytosine contributes significantly to the spectrum with the four outermost valence electronic states beginning at binding energies 8.9, 9.9, 10.4, and 10.85 eV.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Toward resolving the catalytic mechanism of dihydrofolate reductase using neutron and ultrahigh-resolution X-ray crystallography [Neutron and ultrahigh resolution X-ray crystallography reveals water as the proton donor in the catalytic mechanism of dihydrofolate reductase]

Dihydrofolate reductase (DHFR) catalyzes the NADPH-dependent reduction of dihydrofolate (DHF) to tetrahydrofolate (THF). An important step in the mechanism involves proton donation to the N5 atom of DHF. The inability to determine the protonation states of active site residues and substrate has led to the lack of consensus on a catalytic mechanism. To resolve this ambiguity, we conducted neutron and ultrahigh resolution X-ray crystallographic studies of the pseudo-Michaelis ternary complex of DHFR with folate and NADP + from E. coli. The neutron data were collected to 2.0 Å resolution using a 3.6 mm 3 crystal with the quasi-Laue technique, and the structure reveals that the N3 atom of folate is protonated while Asp27 is negatively charged. Previous mechanisms have proposed a keto-to-enol tautomerization of the substrate to facilitate protonation of the N5 atom. The structure supports the existence of the keto tautomer due to protonation of the N3 atom, suggesting tautomerization is unnecessary for catalysis. In the 1.05 Å resolution X-ray structure of the ternary complex, conformational disorder of the Met20 side chain is coupled to electron density for a partially occupied water within hydrogen-bonding distance of the N5 atom of folate; this suggests direct protonation of substrate by solvent. We propose a catalytic mechanism for DHFR that involves stabilization of the keto tautomer of the substrate, elevation of the pK a of the N5 atom of DHF by Asp27, and protonation of N5 by water whose access to the active site is gated by fluctuation of the Met20 side chain even though the Met-20 loop is closed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Coherence Conversion for Optimized Resolution in Optical Measurements - Example of Femtosecond Time Resolution Using the Transverse Coherence of 100-Picosecond X-Rays

A way is proposed to obtain a femtosecond time resolution over a picosecond range in x-ray spectroscopic measurements where the light source and the detector are much slower than that. It is based on the invariance of the modulus of the Fourier transform to object translations. The method geometrically correlates time in the sample with x-ray amplitudes over a spatial coordinate, and then takes the optical Fourier transform through far-field diffraction. Thus, explicitly time-invariant intensities that encode the time evolution of the sample can be measured with a slow detector. This corresponds to a phase-space transformation that converts the transverse coherence to become effective in the longitudinal direction. Because synchrotron-radiation sources have highly anisotropic coherence properties with about $10^5$ longitudinal electromagnetic-field modes at 1 eV bandwidth, but only tens to hundreds transverse modes, coherence conversion can drastically improve the time resolution. Reconstruction of the femtosecond time evolution in the sample from the Fourier intensities is subject to a phase ambiguity that is well-known in crystallography. However, a way is presented to resolve it that is not available in that discipline. Finally, data from a demonstration experiment are presented. The same concept can be used to obtain attosecond time resolution with an x-ray free-electron laser.

Adams, Bernhard W.↗

Simulation study of energy resolution, position resolution and $\pi^0$-$\gamma$ separation of a sampling electromagnetic calorimeter at high energies

A simulation study of energy resolution, position resolution, and π(0)-γ separation using multivariate methods of a sampling calorimeter is presented. As a realistic example, the geometry of the calorimeter is taken from the design geometry of the Shashlik calorimeter which was considered as a candidate for CMS endcap for the phase II of LHC running. The methods proposed in this paper can be easily adapted to various geometrical layouts of a sampling calorimeter. Energy resolution is studied for different layouts and different absorber-scintillator combinations of the Shashlik detector. It is shown that a boosted decision tree using fine grained information of the calorimeter can perform three times better than a cut-based method for separation of π(0) from γ over a large energy range of 20 GeV–200 GeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Jet energy resolution in proton-proton collisions at $\sqrt{\mathrm{s}}=7\mbox{ TeV}$ recorded in 2010 with the ATLAS detector

The measurement of the jet energy resolution is presented using data recorded with the ATLAS detector in proton-proton collisions at √ s = 7 TeV. The sample corresponds to an integrated luminosity of 35 pb -1 . Jets are reconstructed from energy deposits measured by the calorimeters and calibrated using different jet calibration schemes. The jet energy resolution is measured with two different in situ methods which are found to be in agreement within uncertainties. The total uncertainties on these measurements range from 20 % to 10 % for jets within |y| < 2.8 and with transverse momenta increasing from 30 GeV to 500 GeV. Overall, the Monte Carlo simulation of the jet energy resolution agrees with the data within 10 %.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-resolution ptychographic imaging enabled by high-speed multi-pass scanning

As a coherent diffraction imaging technique, ptychography provides high-spatial resolution beyond Rayleigh’s criterion of the focusing optics, but it is also sensitively affected by the decoherence coming from the spatial and temporal variations in the experiment. Here we show that high-speed ptychographic data acquisition with short exposure can effectively reduce the impact from experimental variations. To reach a cumulative dose required for a given resolution, we further demonstrate that a continuous multi-pass scan via high-speed ptychography can achieve high-resolution imaging. This low-dose scan strategy is shown to be more dose-efficient, and has potential for radiation-sensitive sample studies and time-resolved imaging.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Commission < 5 µm spatial resolution x-ray imager for High Resolution Turbulence experiments

This report presents the successful development, commissioning, and deployment of the Scintillation-Based X-ray Imager (SBXI) for the High-Resolution Turbulence (HRT) campaign at the National Ignition Facility (NIF). The SBXI system was designed to overcome the spatial resolution and efficiency limitations of conventional x-ray imaging detectors. Through careful system engineering, rigorous laboratory characterization, and experimental validation at NIF, the SBXI has demonstrated spatial resolution at the object plane of 5 μm (±0.5 μm) and a detective quantum efficiency (DQE) of 34% at 7.2 keV, both of which surpass the requirements set by the campaign, and meeting the L2 milestone. The system’s deployment enables high-fidelity imaging of fine-scale hydrodynamic instabilities, directly supporting advanced turbulence model validation and future high energy density physics research.

42 ENGINEERING↗

Fine Resolution Topographic Mapping of the Jovian Moons: A Ka-Band High Resolution Topographic Mapping Interferometric Synthetic Aperture Radar

The topographic data set obtained by MOLA has provided an unprecedented level of information about Mars' geologic features. The proposed flight of JIMO provides an opportunity to accomplish a similar mapping of and comparable scientific discovery for the Jovian moons through use of an interferometric imaging radar analogous to the Shuttle radar that recently generated a new topographic map of Earth. A Ka-band single pass across-track synthetic aperture radar (SAR) interferometer can provide very high resolution surface elevation maps. The concept would use two antennas mounted at the ends of a deployable boom (similar to the Shuttle Radar Topographic Mapper) extended orthogonal to the direction of flight. Assuming an orbit altitude of approximately 100km and a ground velocity of approximately 1.5 km/sec, horizontal resolutions at the 10 meter level and vertical resolutions at the sub-meter level are possible.

Madsen, S. N.↗

Fine resolution topographic mapping of the Jovian moons: a Ka-band high resolution topographic mapping interferometric synthetic aperture radar

The topographic data set obtained by MOLA has provided an unprecedented level of information about Mars' geologic features. The proposed flight of JIMO provides an opportunity to accomplish a similar mapping of and comparable scientific discovery for the Jovian moons through us of an interferometric imaging radar analogous to the Shuttle radar that recently generated a new topographic map of Earth. A Ka-band single pass across-track synthetic aperture radar (SAR) interferometer can provide very high resolution surface elevation maps. The concept would use two antennas mounted at the ends of a deployable boom (similar to the Shuttle Radar Topographic Mapper) extended orthogonal to the direction of flight. Assuming an orbit altitude of approximately 100 km and a ground velocity of approximately 1.5 km/sec, horizontal resolutions at the 10 meter level and vertical resolutions at the sub-meter level are possible.

Jupiter Icy Moon Orbiter↗

Acoustically Mounted Microcrystals Yield High-Resolution X-ray Structures

We demonstrate a general strategy for determining structures from showers of microcrystals. It uses acoustic droplet ejection to transfer 2.5 nL droplets from the surface of microcrystal slurries, through the air, onto mounting micromesh pins. Individual microcrystals are located by raster-scanning a several-micrometer X-ray beam across the cryocooled micromeshes. X-ray diffraction data sets merged from several micrometer-sized crystals are used to determine 1.8 {angstrom} resolution crystal structures.

58 GEOSCIENCES↗

Coupled-cluster representation of Green function employing modified spectral resolutions of similarity transformed Hamiltonians

In this paper we discuss a new formalism for producing an analytic coupled-cluster (CC) Green's function for an N-electron system by shifting the poles of similarity transformed Hamiltonians represented in N − 1 and N + 1 electron Hilbert spaces. Simple criteria are derived for the states in N − 1 and N + 1 electron spaces that are then corrected in the spectral resolution of the corresponding matrix representations of the similarity transformed Hamiltonian. The accurate description of excited state processes within a Green's function formalism would be of significant importance to a number of scientific communities ranging from physics and chemistry to engineering and the biological sciences. This is because the Green's function methodology provides a direct path for not only calculating properties whose underlying origins come from coupled many-body interactions but also provides a straightforward path for calculating electron transport, response, and correlation functions that allows for a direct link with experiment. As a special case of this general formulation, we discuss the application of this technique for Green's function defined by the CC with singles and doubles representation of the ground-state wave function.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗