Search NASA⌕ Search

SEARCH · Search NASA

Results for “rf source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

50 MW X-BAND RF SYSTEM FOR A PHOTOINJECTOR TEST STATION AT LLNL

In support of X-band photoinjector development efforts at LLNL, a 50 MW test station is being constructed to investigate structure and photocathode optimization for future upgrades. A SLAC XL-4 klystron capable of generating 50 MW, 1.5 microsecond pulses will be the high power RF source for the system. Timing of the laser pulse on the photocathode with the applied RF field places very stringent requirements on phase jitter and drift. To achieve these requirements, the klystron will be powered by a state of the art, solid-state, high voltage modulator. The 50 MW will be divided between the photoinjector and a traveling wave accelerator section. A high power phase shifter is located between the photoinjector and accelerator section to adjust the phasing of the electron bunches with respect to the accelerating field. A variable attenuator is included on the input of the photoinjector. The distribution system including the various x-band components is being designed and constructed. In this paper, we will present the design, layout, and status of the RF system.

42 ENGINEERING↗

SLED-II: A New Method of RF Pulse Compression

In the SLED 1 method of RF pulse compression, two high Q resonators store energy from an RF source for a relatively long time interval (typically 3 to 5 J.1sec). Triggered by a reversal in RF phase, this stored energy is then released during a much shorter interval equal to the filling time of the accelerating structure. A peak power gain on the order of three and a compression efficiency on the order of 60% are typically attained. The shape of the output pulse is, however, a sharply decaying expo- nential. In SLED-II the two cavities are replaced by two lengths of resonant line, forming a Resonant Line SLED (RELS) and resulting in a flat output pulse. Therefore, RELS stages can be cascaded to give a greater peak power gain. Using two stages, a peak power gain greater than ten can be achieved with a reasonable compression efficiency. Unlike the BEC,2 the RELS compression fac- tor per stage is not limited to two, albeit at the expense of intrinsic efficiency. Like the BEC, it uses long lines rather than short cavities.

Farkas, Z.↗

Diagnostics of the ITER neutral beam test facility

The ITER heating neutral beam (HNB) injector, based on negative ions accelerated at 1 MV, will be tested and optimized in the SPIDER source and MITICA full injector prototypes, using a set of diagnostics not available on the ITER HNB. The RF source, where the H{sup -}/D{sup -} production is enhanced by cesium evaporation, will be monitored with thermocouples, electrostatic probes, optical emission spectroscopy, cavity ring down, and laser absorption spectroscopy. The beam is analyzed by cooling water calorimetry, a short pulse instrumented calorimeter, beam emission spectroscopy, visible tomography, and neutron imaging. Design of the diagnostic systems is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling and simulation of a beam emission spectroscopy diagnostic for the ITER prototype neutral beam injector

A test facility for the development of the neutral beam injection system for ITER is under construction at Consorzio RFX. It will host two experiments: SPIDER, a 100 keV H{sup −}/D{sup −} ion RF source, and MITICA, a prototype of the full performance ITER injector (1 MV, 17 MW beam). A set of diagnostics will monitor the operation and allow to optimize the performance of the two prototypes. In particular, beam emission spectroscopy will measure the uniformity and the divergence of the fast particles beam exiting the ion source and travelling through the beam line components. This type of measurement is based on the collection of the H{sub α}/D{sub α} emission resulting from the interaction of the energetic particles with the background gas. A numerical model has been developed to simulate the spectrum of the collected emissions in order to design this diagnostic and to study its performance. The paper describes the model at the base of the simulations and presents the modeled H{sub α} spectra in the case of MITICA experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multipulse Optical-Rectification-Based THz Source for Accelerator Applications

THz sources offer the potential for higher frequencies and higher breakdown thresholds in accelerating structures in comparison with conventional RF sources. They also benefit from larger field strengths, field gradients, better beam synchronization and compactness. In this work, we first present the development of a 49μJ single-cycle THz source centered at 0.6 THz that provides fields over 30 MV/m. With further modifications, multicycle pulses were produced, narrowing the bandwidth of the source and potentially easing the coupling of THz radiation to relativistic electron beams and increasing the usability in other areas of research.

Lenz, Maximilian (ORCID:0009000579693042)↗

High efficiency normal conducting linac for environmental water remediation

A continuous wave (CW) electron accelerator for the treatment of industrial streams including an electron beam source, a modified high efficiency slot coupled cavity, at least one focusing magnet positioned surrounding the accelerator to contain the beam in the accelerator, an efficient radio frequency power supply means for supplying power of a radio frequency to the cavity to induce a TM01 accelerating mode in the cavity, an electron beam spreader or raster, a fixed magnet array or two-dimensional scanning magnet for deflecting the accelerated beam into a desired shape, and an exit window for extracting the deflected electron beam. The accelerator includes a graded-beta cavity to enable use with a low-power pulsed electron source. The accelerator benefits from a low wall-power loss accelerating cavity that is energized with efficient RF sources, enabling it to be operated in continuous wave mode.

Hannon, Fay↗

Python-EPICS RF Conditioning Automatic Control System at the Spallation Neutron Source

The RF Test Facility (RFTF) at the Spallation Neutron Source (SNS) is used for the conditioning of RF compo-nents such as ceramic vacuum windows and power cou-plers prior to their installation in the H- ion linear accel-erator. This process exposes components to high-power RF fields and thermal cycling to improve performance and remove surface impurities. To automate and optimize this process, a Python-based EPICS control system was developed alongside targeted hardware upgrades. The system enables real-time monitoring and control of RF power levels, temperature, and vacuum pressure. A user-friendly graphical interface was implemented using CS-Studio (Phoebus), allowing operators to adjust parameters and collect data efficiently. The system integrates a High-Power Protection Module (HPM) for interlocks based on vacuum and arc detection, ensuring safe operation. These upgrades have significantly improved the efficiency, accuracy, and safety of RF conditioning at the SNS RFTF. This paper describes the updated RF conditioning sys-tem, highlighting the software and hardware develop-ments and their application in support of the Proton Pow-er Upgrade (PPU) project.

Lee, Sung-Woo [ORNL] (ORCID:000000030915835X)↗

Development of a radio-frequency ion beam source for fast-ion studies on the large plasma device

A helium ion beam source (23 kV/2.0 A) has been constructed for studying fast-ion physics in the cylindrical magnetized plasma of the large plasma device (LAPD). An inductive RF source produces a 10{sup 19} m{sup -3} density plasma in a ceramic dome. A multi-aperture, rectangular (8 cm x 8 cm) three-grid system extracts the ion beam from the RF plasma. The ion beam is injected at a variety of pitch angles with Alfvenic speeds in the LAPD. The beam current is intense enough to excite magnetic perturbations in the ambient plasma. Measurements of the ion beam profile were made to achieve an optimum beam performance and a reliable source operation was demonstrated on the LAPD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Numerical modeling of the SNS H{sup −} ion source

Ion source rf antennas that produce H- ions can fail when plasma heating causes ablation of the insulating coating due to small structural defects such as cracks. Reducing antenna failures that reduce the operating capabilities of the Spallation Neutron Source (SNS) accelerator is one of the top priorities of the SNS H- Source Program at ORNL. Numerical modeling of ion sources can provide techniques for optimizing design in order to reduce antenna failures. There are a number of difficulties in developing accurate models of rf inductive plasmas. First, a large range of spatial and temporal scales must be resolved in order to accurately capture the physics of plasma motion, including the Debye length, rf frequencies on the order of tens of MHz, simulation time scales of many hundreds of rf periods, large device sizes on tens of cm, and ion motions that are thousands of times slower than electrons. This results in large simulation domains with many computational cells for solving plasma and electromagnetic equations, short time steps, and long-duration simulations. In order to reduce the computational requirements, one can develop implicit models for both fields and particle motions (e.g. divergence-preserving ADI methods), various electrostatic models, or magnetohydrodynamic models. We have performed simulations using all three of these methods and have found that fluid models have the greatest potential for giving accurate solutions while still being fast enough to perform long timescale simulations in a reasonable amount of time. We have implemented a number of fluid models with electromagnetics using the simulation tool USim and applied them to modeling the SNS H- ion source. We found that a reduced, single-fluid MHD model with an imposed magnetic field due to the rf antenna current and the confining multi-cusp field generated increased bulk plasma velocities of > 200 m/s in the region of the antenna where ablation is often observed in the SNS source. We report here on comparisons of simulated plasma parameters and code performance using more accurate physical models, such as two-temperature extended MHD models, for both a related benchmark system describing a inductively coupled plasma reactor, and for the SNS ion source. We also present results from scaling studies for mesh generation and solvers in the USim simulation code.

07 ISOTOPE AND RADIATION SOURCES↗

Installation of spectrally selective imaging system in RF negative ion source

A spectrally selective imaging system has been installed in the RF negative ion source in the International Thermonuclear Experimental Reactor-relevant negative ion beam test facility ELISE (Extraction from a Large Ion Source Experiment) to investigate distribution of hydrogen Balmer-α emission (H{sub α}) close to the production surface of hydrogen negative ion. We selected a GigE vision camera coupled with an optical band-path filter, which can be controlled remotely using high speed network connection. A distribution of H{sub α} emission near the bias plate has been clearly observed. The same time trend on H{sub α} intensities measured by the imaging diagnostic and the optical emission spectroscopy is confirmed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Self-consistent electrodynamics of large-area high-frequency capacitive plasma discharge

Capacitively coupled plasmas (CCPs) generated using high frequency (3-30 MHz) and very high frequency (30-300 MHz) radio-frequency (rf) sources are used for many plasma processing applications including thin film etching and deposition. When chamber dimensions become commensurate with the effective rf wavelength in the plasma, electromagnetic wave effects impose a significant influence on plasma behavior. Because the effective rf wavelength in plasma depends upon both rf and plasma process conditions (e.g., rf power and gas pressure), a self-consistent model including both the rf power delivery system and the plasma discharge is highly desirable to capture a more complete physical picture of the plasma behavior. A three-dimensional model for self-consistently studying both electrodynamic and plasma dynamic behavior of large-area (Gen 10, >8 m{sup 2}) CCP is described in this paper. This model includes Maxwell's equations and transport equations for charged and neutral species, which are coupled and solved in the time domain. The complete rf plasma discharge chamber including the rf power delivery subsystem, rf feed, electrodes, and the plasma domain is modeled as an integrated system. Based on this full-wave solution model, important limitations for processing uniformity imposed by electromagnetic wave propagation effects in a large-area CCP (3.05x2.85 m{sup 2} electrode size) are studied. The behavior of H{sub 2} plasmas in such a reactor is examined from 13.56 to 200 MHz. It is shown that various rectangular harmonics of electromagnetic fields can be excited in a large-area rectangular reactor as the rf or power is increased. The rectangular harmonics can create not only center-high plasma distribution but also high plasma density at the corners and along the edges of the reactor.

36 MATERIALS SCIENCE↗

Long Pulse H{sup -} Beam Extraction With A RF Driven Ion Source With Low Fraction Of Co-Extracted Electrons

IPP Garching is developing H{sup -}/D{sup -} RF ion sources for the ITER neutral beam system. On the MANITU testbed the experiments are focussed on long pulse H{sup -}/D{sup -} beam extraction with a 100 kW prototype source. The negative ion production is based on surface conversion of atoms and positive ions on Caesium layers. In long pulses with H{sup -} beam extraction the ion currents were stable but with too high fraction of co-extracted electrons. The electron current could be lowered considerably by avoiding copper impurities from the Faraday screen in the plasma which was achieved by coating of the inner surfaces of the source with Molybdenum. A positive bias potential with respect to the source applied to the plasma grid, the bias plate or to a metal rod installed near the plasma grid enables regulation of the electron current during long pulses. In this way low values consistent with the ITER requirements can be achieved without significant loss of ion current.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of Open Waveguide RF Hazard

Radiofrequency (RF) radiation is used in particle accelerators to develop electromagnetic fields in resonant cavities coupled to the RF source. Particles passing through the aperture in a resonant cavity are accelerated by the electric field and deflected by the magnetic field. Accelerator staff manage RF exposure hazards by using a robust combination of engineered safeguards and administrative controls - much like other industrial hazards. Consequently, direct exposure to RF (from an open wave guide, for example) is an extremely unlikely scenario. However, it is important to eliminate any scenario that might lead to such an event and it is instructive to evaluate the prompt somatic effects. This presentation discusses one possible scenario by which hazardous RF exposure can occur at a particle accelerator and the possible outcomes.

May, Robert↗

Linear accelerator x-ray sources with high duty cycle

X-ray cargo inspection systems typically use a several-MV pulsed linear accelerator (linac) to produce a bremsstrahlung spectrum of x rays by bombarding a target with electrons. The x rays traverse the cargo and are detected by a detector array. Spectroscopy of the detected x rays is very desirable: if one can determine the spectrum of the transmitted x rays, one can determine the Z of the material they traversed. Even in relatively low-dose modes of operation, thousands of x rays arrive at each detector element during each pulse, unless the x rays are heavily absorbed or scattered by the cargo. For portal or fixed-site systems, dose rates, and therefore x-ray count rates, are even higher. Because of the high x-ray count rate, spectroscopy is impractical in conventional cargo inspection systems, except in certain special cases. For a mobile system, typical pulse durations are a few microseconds, and the number of pulses is on the order of 100 per second, leading to a duty factor of about 0.04%. Clearly, a linear accelerator x-ray source with much higher duty factor would be useful, since then the same number of x rays could be spread out over time, reducing the x-ray count rate. In this paper, we explore the possibility of designing a linear accelerator system, using more or less Conventional Off the Shelf (COTS) components, capable of duty cycles of 1% or greater. A survey was conducted of available linac RF source options and, given the possibilities, calculations were performed for suitable beam centerline designs. Keeping in mind that the size and cost of the accelerator system should be practical for use in a mobile cargo inspection system, only a few options are shown to be reasonably feasible, both requiring the use of klystrons instead of the magnetrons used in conventional systems. An S-Band design appears clearly possible, and there is also a promising X-Band design.

43 PARTICLE ACCELERATORS↗

Application of Goubau Surface Wave Transmission Line for Improved Bench Testing of Diagnostic Beamline Elements

In-air test fixtures for beamline elements typically utilize an X-Y positioning stage, and a wire antenna excited by an RF source. In most cases, the antenna contains a standing wave, and is useful only for coarse alignment measurements in CW mode. A surface-wave (SW) based transmission line permits RF energy to be launched on the wire, travel through the beamline component, and then be absorbed in a load. Since SW transmission lines employ travelling waves, the RF energy can be made to resemble the electron beam, limited only by ohmic losses and dispersion. Although lossy coaxial systems are also a consideration, the diameter of the coax introduces large uncertainties in centroid location. A SW wire is easily constructed out of 200 micron magnet wire, which more accurately approximates the physical profile of the electron beam. Benefits of this test fixture include accurate field mapping, absolute calibration for given beam currents, Z-axis independence, and temporal response measurements of sub-nanosecond pulse structures. Descriptions of the surface wave launching technique, transmission line, and instrumentation are presented, along with measurement data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-MW K-Band 7th Harmonic Multiplier for High-Gradient Accelerator R&D

A preliminary design and current status are presented for a two-cavity 7th harmonic multiplier, intended as a high-power RF source for use in experiments aimed at developing high-gradient structures for a future collider. The harmonic multiplier is to produce power in K-band using as its RF driver an XK-5 S-band klystron (2.856 GHz). The multiplier is to be built with a TE{sub 111} rotating mode input cavity and interchangeable output cavities, a principal example being a TE{sub 711} rotating mode cavity running at 20 GHz. The design that is described uses a 250 kV, 20 A injected laminar electron beam. With 8.5 MW of S-band drive power, 4.4 MW of 20-GHz output power is predicted. The design uses a gun, magnetic coils, and beam collector from an existing waveguide 7th harmonic multiplier. The gun has been re-conditioned and the desired operating parameters have been achieved.

43 PARTICLE ACCELERATORS↗

Broadband RF Interferometric Mapping and Polarization (BIMAP) Observations of Lightning Discharges: Revealing New Physics Insights Into Breakdown Processes

We report broadband radio frequency (RF) interferometry was first introduced in 1996 for lightning studies. The technique has since been improved significantly and has been increasingly widely used in the lightning community. In addition to the interferometry, we now introduce a broadband polarization capability that simultaneously measures the full polarization state of the corresponding RF sources. Polarization observation provides another level of understanding of the discharge processes. In this paper, we describe the new system and present example observations with such a system. Initial observations of impulsive lightning RF pulses, a K-event leader, and the initiating process for an intracloud flash are presented. The impulsive pulses were often linearly polarized and are consistent with conventional breakdown processes, whereas some occasional pulses were elliptically polarized and are likely related to relativistic breakdown processes. The K-event was detected polarized along a section of its channel, and the orientation of the polarization was mostly orthogonal to the channel, apparently due to the preceding charge deposition along the channel. The intracloud flash in this paper was initiated with downward fast positive streamers, and the corresponding signals were linearly polarized, consistent with conventional breakdown processes. The orientations of the polarization were nearly uniformly aligned with the propagation direction of the streamers, indicating a near uniform electric field in the region of the initiating streamers. Lastly, an observation of a cosmic-ray shower is presented.

58 GEOSCIENCES↗

Single element of the matrix source of negative hydrogen ions: Measurements of the extracted currents combined with diagnostics

Combining measurements of the extracted currents with probe and laser-photodetachment diagnostics, the study is an extension of recent tests of factors and gas-discharge conditions stimulating the extraction of volume produced negative ions. The experiment is in a single element of a rf source with the design of a matrix of small-radius inductively driven discharges. The results are for the electron and negative-ion densities, for the plasma potential and for the electronegativity in the vicinity of the plasma electrode as well as for the currents of the extracted negative ions and electrons. The plasma-electrode bias and the rf power have been varied. Necessity of a high bias to the plasma electrode and stable linear increase of the extracted currents with the rf power are the main conclusions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗