ISRU Pilot Excavator: Bucket Drum Scaling Experimental Results

NASA’s Space Technology Mission Directorate (STMD) is funding the development of a robotic excavator called the “ISRU Pilot Excavator” which will be a technology demonstration of excavating and transporting 10 metric tons of lunar regolith on the surface of the moon with a 30k-class robotic excavator. ISRU Pilot Excavator will be the next generation of robotic excavator to use bucket drums as excavation tools. This is an evolution of the Regolith Advanced Surface Systems Operations Robot (RASSOR) developed at NASA’s Kennedy Space Center. Bucket drums are hollow cylinders with regularly spaced scoops around the perimeter. The drums rotate in one direction to collect regolith with the scoops. The regolith slides down an internal baffling system inside the drum which prevents the regolith from falling back out of the scoops. The captured regolith can then be transported while held in the drum and then deposited by rotating the drum in the opposite direction allowing the regolith to slide back down the baffling and out of the excavation scoops. Bucket drums were developed by Lockheed Martin in 2008 and used on multiple robotic excavator prototypes ever since. However the forces on a bucket drum and considerations for scaling have not been measured in detail. Bucket drums are challenging to model using classical blade\bucket equations because of their unique geometry. Therefore this experiment was performed to measure the forces on three bucket drums of the same geometry at different scales. Small: 9.4” (239mm) dia. x 8.1” (206mm) width, Medium: 11.6” (294mm) dia. x 10” (254mm) width, and Large: 17” (432mm) dia. x 14.1”(358mm) width. The test stand consisted of an actuated gantry with controlled motion in the vertical (Z) and horizontal (X) axes and a single rotation axis (R). The bucket drums were individually mounted to the rotary axis of the test stand and translated across a prepared bed of BP-1 lunar regolith simulant at a specified linear speed and cutting depth. The test stand was outfitted with a torque sensor in line with the rotation of the drum (R) and a 3 axis (X, Y, and Z) load cell. In addition to the three sizes of bucket drums the linear excavation speed and cutting depth were test variables. The results of these experiments show the relationship between the three scales of bucket drums for factors such as: excavation force, torque due to regolith rotation inside the drum, excavation energy, time to fill, etc. and will be discussed in detail in this paper. This fundamental data will be used in the design of the ISRU Pilot Excavator and can inform the design of future bucket drum excavators.

Jason Michael Schuler↗

ISRU Pilot Excavator: Bucket Drum Scaling Experimental Results

NASA’s Space Technology Mission Directorate (STMD) is funding the development of a robotic excavator called the “ISRU Pilot Excavator” (IPEx) which will be a technology demonstration of excavating and transporting 10 metric tons of lunar regolith on the surface of the moon with a 30kg-class robotic excavator. IPEx will be the next generation of robotic excavators to use bucket drums as excavation tools. This is an evolution of the Regolith Advanced Surface Systems Operations Robot (RASSOR) developed at NASA’s Kennedy Space Center (KSC). Bucket drums are hollow cylinders with regularly spaced scoops around the perimeter. The drums rotate in one direction to collect regolith with the scoops. The regolith slides down an internal baffling system inside the drum which prevents the regolith from falling back out of the scoops (see Figure 1). The captured regolith can then be transported while held in the drum and then deposited by rotating the drum in the opposite direction allowing the regolith to slide back down the baffling and out of the excavation scoops. Bucket drums were developed by Lockheed Martin in 2008 and used on multiple robotic excavator prototypes ever since. However, the forces on a bucket drum and considerations for scaling have not been measured in detail. Bucket drums are challenging to model using classical blade\bucket equations because of their unique geometry. Therefore, this experiment was performed to measure the forces on three bucket drums of the same geometry at different scales. Small: 9.4” (239mm) dia. x 8.1” (206mm) width, Medium: 11.6” (294mm) dia. x 10” (254mm) width, and Large: 17” (432mm) dia. x 14.1” (358mm) width. The test stand consisted of an actuated gantry with controlled motion in the vertical (Z) and horizontal (X) axes and a single rotation axis (R). The bucket drums were individually mounted to the rotary axis of the test stand and translated across a prepared bed of BP-1 lunar regolith simulant at a specified linear speed and cutting depth. The test stand was outfitted with a torque sensor in line with the rotation of the drum (R) and a 3 axis (X, Y, and Z) load cell. In addition to the three sizes of bucket drums the linear excavation speed and cutting depth were test variables. The results of these experiments show the relationship between the three scales of bucket drums for factors such as: excavation force, torque due to regolith rotation inside the drum, excavation energy, time to fill, etc. and will be discussed in detail in this paper. This fundamental data will be used in the design of IPEx and can inform the design of future bucket drum excavators.

RASSOR↗

Flexure Based Linear and Rotary Bearings

A flexure based linear bearing includes top and bottom parallel rigid plates; first and second flexures connecting the top and bottom plates and constraining exactly four degrees of freedom of relative motion of the plates, the four degrees of freedom being X and Y axis translation and rotation about the X and Y axes; and a strut connecting the top and bottom plates and further constraining exactly one degree of freedom of the plates, the one degree of freedom being one of Z axis translation and rotation about the Z axis.

Voellmer, George M.↗

A dynamic analysis of the motion of a low-wing general aviation aircraft about its calculated equilibrium flat spin mode

The properties of the flat spin mode of a general aviation configuration have been studied through analysis of rotary balance data, numerical simulation, and analytical study of the equilibrium state. The equilibrium state is predicted well from rotary balance data. The variations of yawing moment and pitching moment as functions of sideslip have been shown to be of great importance in obtaining accurate modeling. These dependencies are not presently available with sufficient accuracy from previous tests or theories. The stability of the flat spin mode has been examined extensively using numerical linearization, classical perturbation methods, and reduced order modeling. The stability exhibited by the time histories and the eigenvalue analyses is shown to be strongly dependent on certain static cross derivatives and more so on the dynamic derivatives. Explicit stability criteria are obtained from the reduced order models.

Tischler, M. B.↗

Fluid management technology: Liquid slosh dynamics and control

Flight experiments were defined for the Cryogenic On-Orbit Liquid Depot Storage, Acquisition and Transfer Satellite (COLD-SAT) test bed satellite and the Shuttle middeck to help establish the influence of the gravitational environment on liquid slosh dynamics and control. Several analytical and experimental studies were also conducted to support the experiments and to help understand the anticipated results. Both FLOW-3D and NASA-VOF3D computer codes were utilized to simulate low Bond number, small amplitude sloshing, for which the motions are dominated by surface forces; it was found that neither code provided a satisfactory simulation. Thus, a new analysis of low Bond number sloshing was formulated, using an integral minimization technique that will allow the assumptions made about surface physics phenomena to be modified easily when better knowledge becomes available from flight experiments. Several examples were computed by the innovative use of a finite-element structural code. An existing spherical-pendulum analogy of nonlinear, rotary sloshing was also modified for easier use and extended to low-gravity conditions. Laboratory experiments were conducted to determine the requirements for liquid-vapor interface sensors as a method of resolving liquid surface motions in flight experiments. The feasibility of measuring the small slosh forces anticipated in flight experiments was also investigated.

Dodge, Franklin T.↗

Rotorcraft Flight Dynamics and Controls Research at NASA

In recent years, NASA has invested in key activities in the areas of flight controls, handling qualities and operations of rotorcraft for civilian applications. More specifically, the flight dynamics and control discipline has focused on analyzing the unique flight control and handling qualities challenges of large rotary wing vehicles anticipated for future passenger service, and examining the effect of control system augmentation on handling qualities for current civilian helicopters in order to improve safety and reduce accident rates. This paper highlights two recent research efforts in these areas. The first is an examination of flight control and handling qualities aspects of large rotorcraft. A series of experiments were performed in the large-motion Vertical Motion Simulator at NASA Ames Research Center to quantify the effects of vehicle size on flight control requirements and piloted handling qualities. These experiments used a large tilt-rotor concept (~100 passengers) to also investigate the control augmentation required to obtain Level 1 handling qualities for a vehicle of this size. The second is an examination of the effect of control system augmentation on handling qualities for current civil rotorcraft, like those currently used for Emergency Medical Service type operations. Many current civilian helicopters have rate response type control systems and little or no control system augmentation, although current technologies allow helicopters to be fitted with stability augmentation systems, either as standard equipment or aftermarket options. A simulation experiment was conducted in the Vertical Motion Simulator to quantify the effects of advanced control modes available with a partial authority stability augmentation system on task performance and handling qualities in both good and degraded visual conditions. In addition to providing an overview of the rotary wing flight dynamics and controls research at NASA, this paper will provide an overview of these two research activities along with key results and conclusions.

Research at NASA↗

Rotorcraft Flight Dynamics and Controls Research at NASA

In recent years, NASA has invested in key activities in the areas of flight controls, handling qualities and operations of rotorcraft for civilian applications. More specifically, the flight dynamics and control discipline has focused on analyzing the unique flight control and handling qualities challenges of large rotary wing vehicles anticipated for future passenger service, and examining the effect of control system augmentation on handling qualities for current civilian helicopters in order to improve safety and reduce accident rates. This paper highlights two recent research efforts in these areas. The first is an examination of flight control and handling qualities aspects of large rotorcraft. A series of experiments were performed in the large-motion Vertical Motion Simulator at NASA Ames Research Center to quantify the effects of vehicle size on flight control requirements and piloted handling qualities. These experiments used a large tilt-rotor concept (~100 passengers) to also investigate the control augmentation required to obtain Level 1 handling qualities for a vehicle of this size. The second is an examination of the effect of control system augmentation on handling qualities for current civil rotorcraft, like those currently used for Emergency Medical Service type operations. Many current civilian helicopters have rate response type control systems and little or no control system augmentation, although current technologies allow helicopters to be fitted with stability augmentation systems, either as standard equipment or aftermarket options. A simulation experiment was conducted in the Vertical Motion Simulator to quantify the effects of advanced control modes available with a partial authority stability augmentation system on task performance and handling qualities in both good and degraded visual conditions. In addition to providing an overview of the rotary wing flight dynamics and controls research at NASA, this paper will provide an overview of these two research activities along with key results and conclusions.

Rotorcraft↗

Special cases of friction and applications

Two techniques for reducing friction forces are presented. The techniques are applied to the generalized problem of reducing the friction between kinematic pairs which connect a moveable link to a frame. The basic principles are: (1) Let the moveable link be supported by two bearings where the relative velocities of the link with respect to each bearing are of opposite directions. Thus the resultant force (torque) of friction acting on the link due to the bearings is approximately zero. Then, additional perturbation of motion parallel to the main motion of the moveable link will require only a very small force; (2) Let the perturbation in motion be perpendicular to the main motion. Equations are developed which explain these two methods. The results are discussed in relation to friction in geared couplings, gyroscope gimbal bearings and a rotary conveyor system. Design examples are presented.

Litvin, F. L.↗

Special cases of friction and applications

Two techniques for reducing friction forces are presented. The techniques are applied to the generalized problem of reducing the friction between kinematic pairs which connect a moveable link to a frame. The basic principles are: (1) Let the moveable link be supported by two bearings where the relative velocities of the link with respect to each bearing are of opposite directions. Thus the resultant force (torque) of friction acting on the link due to the bearings is approximately zero. Then, additional perturbation of motion parallel to the main motion of the moveable link will require only a very small force; (2) Let the perturbation in motion be perpendicular to the main motion. Equations are developed which explain these two methods. The results are discussed in relation to friction in geared couplings, gyroscope gimbal bearings and a rotary conveyor system. Design examples are presented.

Litvin, F. L.↗

Estimation of Aircraft Nonlinear Unsteady Parameters From Wind Tunnel Data

Aerodynamic equations were formulated for an aircraft in one-degree-of-freedom large amplitude motion about each of its body axes. The model formulation based on indicial functions separated the resulting aerodynamic forces and moments into static terms, purely rotary terms and unsteady terms. Model identification from experimental data combined stepwise regression and maximum likelihood estimation in a two-stage optimization algorithm that can identify the unsteady term and rotary term if necessary. The identification scheme was applied to oscillatory data in two examples. The model identified from experimental data fit the data well, however, some parameters were estimated with limited accuracy. The resulting model was a good predictor for oscillatory and ramp input data.

Klein, Vladislav↗

Prototyping of a Rotary Triboelectric Nanogenerator for Power at Sea

Increasing at-sea power generation by Triboelectric Nanogenerator (TENG) energy harvesters towards the order of 1-Watt will create significant opportunities to power ocean observation buoys and distributed sensor nodes by extending mission time and increasing sensor payload. Of the many possible configurations of harvesting wave energy with TENGs, we document the rationale for choosing and developing a rotary TENG that operates by the freestanding mode. The rotary TENG prototype consists of two plates, a rotor and a stator, to take advantage of the various mechanisms of converting wave action into rotational motion. We have constructed a testing apparatus that allows us to vary several key parameters of the device: distance between rotor and stator, triboelectric material, rotational speed, number of electrodes and output load impedance. Preliminary results show that when driven at a constant 500 rpm, we can achieve a power density of 0.7 W/m3. A variable speed motor drives the rotor, which can be driven using a velocity profile informed by the equivalent to the output from a wave energy converter (WEC). The optimized rotational TENG can be stacked and driven by a single shaft, increasing the energy density of the device. The output of such a TENG could be used to power devices in the ocean at a low cost and high durability.

electrostatic generator↗

Postural illusions experienced during Z-axis recumbent rotation and their dependence upon somatosensory stimulation of the body surface

A blindfolded recumbent subject experiences a variety of postural illusions when rotated about his Z axis. Initially, during the acceleratory phase of rotation, turning about his Z axis is experienced; but, as rotary velocity increases, a spiraling of the body outward in the direction opposite to true rotation is experienced as well. Above 15-20 rpm, only orbital motion of the body is experienced, with the subject feeling that he is always facing in the same direction. One cycle of the apparent orbit is completed each time the subject actually rotates 360 deg. The reverse sequence of illusory motion is experienced during deceleration. The illusory motion all subjects experience during Z-axis recumbent rotation is shown to depend upon the touch and pressure stimulation of the body surface generated by contact forces of support.

Lackner, J. R.↗

Eigenvalues and stability problems of rotors

The essential theoretical results of the application of a developed transfer matrix method to the free transverse vibration of a rotor are shown. Gyroscopic and shear effects, rotary inertia, and external and internal damping as well as the influence of sleeve bearings and rotor supports are taken into consideration. The eigenvalues of the motion equations of the rotor are searched by using a modified determinant method.

Walczyk, Z.↗

Force reflecting hand controller

A universal input device for interfacing a human operator with a slave machine such as a robot or the like includes a plurality of serially connected mechanical links extending from a base. A handgrip is connected to the mechanical links distal from the base such that a human operator may grasp the handgrip and control the position thereof relative to the base through the mechanical links. A plurality of rotary joints is arranged to connect the mechanical links together to provide at least three translational degrees of freedom and at least three rotational degrees of freedom of motion of the handgrip relative to the base. A cable and pulley assembly for each joint is connected to a corresponding motor for transmitting forces from the slave machine to the handgrip to provide kinesthetic feedback to the operator and for producing control signals that may be transmitted from the handgrip to the slave machine. The device gives excellent kinesthetic feedback, high-fidelity force/torque feedback, a kinematically simple structure, mechanically decoupled motion in all six degrees of freedom, and zero backlash. The device also has a much larger work envelope, greater stiffness and responsiveness, smaller stowage volume, and better overlap of the human operator's range of motion than previous designs.

Mcaffee, Douglas A.↗

Electrically Controlled Valve With Small Motor

Design of electrically controlled valve exploits force-multiplying principle to overcome large back-pressure force resisting initial opening. Design makes possible to open valve by use of relatively small motor adequate for rest of valve motion, but otherwise not large enough to open valve. In simple linear lifting, small horizontal forces applied to pair of taut cables to lift large weight through short distance. In rotary lifting, similar effect achieved by rotating, about an axis, disk to which initially axial cables attached.

Reinicke, Robert H.↗

The Effects on Dynamic Lateral Stability and Control of Large Artificial Variations in the Rotary Stability Derivatives

This report presents the results of an investigation conducted in the Langley free-flight tunnel to determine the effects of large artificial variations of several rotary lateral-stability derivatives on the dynamic lateral stability and control characteristics of a 45 degree sweptback-wing airplane model. Calculations of the period and damping of the lateral motions and of the response to roll and yaw disturbances were made for correlation with the experimental results. The calculated results were in qualitative agreement with the experimental results in predicting the general trends in flight characteristics produced by large changes in the stability derivatives, but in some cases the theory with the assumption of zero lag was not in good quantitative agreement with the experimental results.

Schade, Robert O↗

HART-II Acoustic Predictions using a Coupled CFD/CSD Method

This paper documents results to date from the Rotorcraft Acoustic Characterization and Mitigation activity under the NASA Subsonic Rotary Wing Project. The primary goal of this activity is to develop a NASA rotorcraft impulsive noise prediction capability which uses first principles fluid dynamics and structural dynamics. During this effort, elastic blade motion and co-processing capabilities have been included in a recent version of the computational fluid dynamics code (CFD). The CFD code is loosely coupled to computational structural dynamics (CSD) code using new interface codes. The CFD/CSD coupled solution is then used to compute impulsive noise on a plane under the rotor using the Ffowcs Williams-Hawkings solver. This code system is then applied to a range of cases from the Higher Harmonic Aeroacoustic Rotor Test II (HART-II) experiment. For all cases presented, the full experimental configuration (i.e., rotor and wind tunnel sting mount) are used in the coupled CFD/CSD solutions. Results show good correlation between measured and predicted loading and loading time derivative at the only measured radial station. A contributing factor for a typically seen loading mean-value offset between measured data and predictions data is examined. Impulsive noise predictions on the measured microphone plane under the rotor compare favorably with measured mid-frequency noise for all cases. Flow visualization of the BL and MN cases shows that vortex structures generated in the prediction method are consist with measurements. Future application of the prediction method is discussed.

Boyd, D. Douglas, Jr.↗