Search NASA⌕ Search

SEARCH · Search NASA

Results for “salt stress”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Growth of high-quality thin-film Ge single crystals by plasma-enhanced chemical vapor deposition

Thin-film Ge single crystals (approx. 10 microns) have been epitaxially grown on polished NaCl(100) substrates at 450C by using plasma-enhanced chemical vapor deposition. Films on approximately 1 sq cm and larger were separated from the NaCl by either melting the salt or by differential shear stress upon cooling to room temperature. The ordered growth of the Ge was found to be most sensitive to the initial plasma power and to the continuum flow dynamics within the carbon susceptor. The films were visually specular and exhibited a high degree of crysalline order when examined by X-ray diffraction. The films were found to be p-type with a carrier concentration of approximately 3 x 10 to the 16th power/cu cm, a resistivity of 0.11 ohm-cm, and a Hall hole mobility of 1820 sq cm/v/s at room temperature. Vacuum firing minimized the primary contaminant, Na, and corresponding lowered the carrier concentration to 4 x 10 to the 14th power/cu cm.

Outlaw, R. A.↗

Laser-Based Instrument Measures Propagation Of Cracks

Report describes use of commerical laser displacement meter to measure propagation of cracks in stainless-steel specimens in stress tests in corrosive (salt-spray) environment. Measurements directed toward determining time from beginning of each test until onset of propagation of crack.

Lee, Rupert U.↗

GRAPHITE–MOLTEN SALT CONSIDERATIONS FOR COMPONENTS IN NUCLEAR APPLICATIONS

The new High Temperature Reactor (HTR) designs being considered for future Gen IV nuclear reactor deployment include designs utilizing molten salt as the primary coolant. These molten-salt cooled, graphite core designs pose new material compatibility challenges that are not considered within the gas-cooled HTR designs that have been previously built and operated. While the Molten Salt Reactor Experiment (MSRE) demonstrated that the molten salt can be considered chemically inert to graphite the novel physical and thermal interactions that the molten salt poses may be just as impactful as the chemical reactivity. Specifically, molten salt intrusion into the open pore structure of nuclear graphite grades can provide additional internal stresses within the microstructure exacerbating the stress buildup from irradiation induced dimensional change. Additionally, designs using a molten salt containing liquid fuel could provide “hot spots” within graphite structural components causing local thermal stresses. Abrasion and erosion concerns are magnified with molten salt due to the extremely high density of the salts (some have higher densities than the structural graphite components). Finally, the graphite-graphite and fuel pebble-graphite tribological behavior are distinctly difference within the molten salt from the inert gas environments and must be investigated. These topics and others are currently under investigation within the DOE Advanced Reactor Technologies (ART) graphite program and will be discussed in depth.

Gallego, Nidia↗

Reprocessable and Recyclable Polymer Network Electrolytes via Incorporation of Dynamic Covalent Bonds

Mechanically durable polymer network electrolytes are desirable for batteries; however, covalent cross-linking adversely affects their large-scale manufacturing, and they are difficult to recycle post-lifespan. In this work, we address the electrolyte reprocessability and recyclability challenges through the use of dynamic covalent bonds for polymer network solid electrolytes. Specifically, the associative dynamic vinylogous urethane motif is incorporated into a poly(ethylene oxide) network electrolyte containing lithium bis(fluorosulfonyl)imide (LiFSI) salt. The resulting dynamic covalent network electrolyte possesses a modest ion conductivity (~10–5 S/cm at room temperature) and good reprocessability. Stress–relaxation studies indicate that the LiFSI salt can catalyze the bond exchange and enhance the network dynamics. Furthermore, the reprocessability associated with bond exchange can be tuned by simply adjusting the formulation of reagent compositions, in which increasing the amount of excess amine or using a shorter chain of PEO prepolymer can further enhance the network dynamics and corresponding reprocessability.

25 ENERGY STORAGE↗

Microscale THMC Modeling of Pressure Solution in Salt Rock: Impacts of Geometry and Temperature

Abstract Pressure solution, a mechanism that involves tight coupling between the geometry and thermal-hydro-mechanical-chemical (THMC) processes, plays an important role in diagenesis. In this study, we make the first attempt to conduct microscale THMC modeling to understand and quantify the impacts of geometry and temperature on pressure solution, taking natural salt rock as an example. This modeling capability is achieved by expanding a novel MC code that we developed previously (Hu et al. J Geophys Res: Solid Earth 126:e2021JB023112, 2021) to include temperature effects. We first conduct a simulation of an example that involves a single brine inclusion within a single halite grain and find that the temperature impact is limited for that case. We then extract geometry from an image of a natural salt rock and conduct simulations with different cases: (A) only temperature and no stress, (B) only stress and no temperature, and (C) with both stress and temperature. These different cases result in quite different phenomena. In case A, dissolution and precipitation occur across the entire system due to isolated pore space reaching a localized mass balance between dissolution, precipitation, and diffusion. In case B, intense geometric features (e.g., major asperities, inclusions) in one area undergo stress concentration, thus dominating pressure solution in that area. In case C, pressure solution is spread out at contacting highly stressed geometric features close to the hotter side. We conclude that geometric features dominate stress distribution, thus dominating pressure solution in a natural salt rock that may be affected by the temperature if a sufficient temperature gradient is applied.

58 GEOSCIENCES↗

Slow Strain Rate Testing of A537 Tank Wall Material

At Savannah River Site (SRS), High-Level Waste is stored in below-grade carbon steel tanks. This waste in part consists of sludge, salt cake, and/or supernate. Preparation of this waste for future processing involves dissolution of the salt cake layer. The salt dissolution process can create conditions that leave the carbon steel tanks susceptible to localized corrosion. The salt to be dissolved contains high concentrations of nitrate, that once released, create an environment that may be conducive to pitting corrosion and/or stress corrosion cracking (SCC) of carbon steel. The salt dissolution process also liberates interstitial liquid trapped between the salt crystals. This liquid is initially high in nitrite and hydroxide concentration. High pH and greater ratios of nitrite to nitrate act as inhibitors to minimize corrosion of carbon steel in high nitrate environments. However, as dissolution proceeds, the concentration of nitrate will increase, while the hydroxide and nitrite concentration of the interstitial liquid will deplete and become insufficient to prevent the onset of corrosion attack. Tank blending and the addition of inhibitors are used to ensure adequate concentrations of hydroxide and nitrite. However, this is not desirable during salt dissolution as it can reduce process efficiency and increase the amount of waste that needs processing. This testing program was designed to examine the risk of SCC associated with utilizing the pitting factor (PF) and nitrite/nitrate (NO 2 - /NO 3 - ) ratio limits for handling dissolved salt solutions at an elevated temperature in the carbon steel waste tanks. The previously identified limits are a PF of 1.2 and an NO 2 - /NO 3 - ratio of 0.15. The results indicate that as long as the NO 2 - /NO 3 - ratio exceeds 0.1 and the PF is above approximately 0.8, there is a discernible safety margin between the open circuit potential (OCP) and the critical cracking potential (CCP) observed during applied potential testing. However, this margin, defined by the difference between the OCP and CCP, is relatively narrow, ranging from 0.1 to 0.25 volts. This small margin raises concerns about potential shifts in OCP during waste retrieval operations, which could inadvertently increase the risk of SCC if the OCP approaches or exceeds the CCP. These results confirm that dissolved salt solutions provide a potent chemistry that, under certain conditions, makes carbon steel susceptible to SCC. The next question to consider is the influence these results have on decisions for storage and retrieval of waste from the tanks. For Type III/IIIA waste tanks, the risk of SCC remains very low. First, and most importantly, the post-weld stress relief of the tanks has reduced the residual stress near the welds. Thus, without the stress component, SCC risk is minimized. The material of construction (A537 Carbon steel) for the Type III/IIIA tanks is superior to the steel in its resistance to SCC than the steel that was utilized for the Type I, II, and IV tanks (A285 carbon steel). From a chemistry control standpoint for a Type III/IIIA tank directly involved with handling dissolved salt solutions, the PF and NO 2 - /NO 3 - ratio limits may be utilized wherein chemistry control provides an extra layer of defense against SCC. Chemistry control for a Type III/IIIA tank minimizes the risk for a tank that may receive the dissolved salt solution, particularly if that tank is a Type I, II, or IV waste tank. On the other hand, if the dissolved salt solution is handled by a Type I, II, or IV waste tank the risk of SCC is real. The potent chemistry, absence of stress relief, and inferior material result in a condition that is conducive to cracking. Efforts should be made to either avoid transferring waste that may not meet the PF and NO 2 - /NO 3 - ratio criteria to one of these tanks or if it is unavoidable, take measures to minimize the consequences of a leak. As shown by these tests, even if the PF and NO 2 - /NO 3 - ratio criteria are met, there is a risk that the tank potential may be disturbed in the positive direction and the risk of SCC increase.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Exopolysaccharide is required for motility, stress tolerance, and plant colonization by the endophytic bacterium Paraburkholderia phytofirmans PsJN

Paraburkholderia phytofirmans PsJN is an endophytic bacterium and has been shown to promote the growth and health of many different plants. Exopolysaccharide (EPS) plays important roles in plant-bacteria interaction and tolerance to environmental stresses. However, the function of EPS in PsJN and its interaction with plants remain largely unknown. In this study, a deletion mutation of bceQ gene, encoding a putative flippase for the EPS biosynthesis, was introduced in the genome of PsJN. The ΔbceQ mutant produced a significantly lower level of EPS than the wild type strain in culture media. Compared to the wild type PsJN, the ΔbceQ mutant was more sensitive to desiccation, UV damage, salt (NaCl) and iron (FeCl 3 ) stresses, and bacteriophage infection. More importantly, the mutation of bceQ decreased the endophytic colonization of PsJN in camelina (Camelina sativa) and pea (Camelina sativa) under plant drought stress conditions. To the best of our knowledge, this is the first report that EPS production is required for the maximal colonization of an endophytic bacterium in the plant tissues under stress conditions.

59 BASIC BIOLOGICAL SCIENCES↗

Effects of sodium and calcium chloride ionic stresses on model yeast membranes revealed by molecular dynamics simulation

As efforts to move a renewable economy grow, it will be necessary to make use of microbial conversion strategies for the production of novel materials or the upgrading of waste to high-value products. One critical technical challenge currently limiting waste upgrading remains the difficulty in obtaining single-pot conversion techniques where physical, chemical, and biological conversion are performed in a single step. To overcome this challenge, a detailed understanding of how different stresses impact microbial membrane stability will be necessary. In this work, using all-atom molecular dynamics simulations, we examine the impacts of moderate concentrations of NaCl and CaCl 2 on a model yeast plasma membrane. Weak, though statistically significant, changes in membrane morphology and dynamics functions are observed that are consistent with swelling and stiffening. Additionally, an examination of the ion-lipid contacts and the behavior of water at the water-membrane interface suggests that the impacts of these common salts may, in part, be mediated through changes to water-membrane hydrogen-bonding and hydration water dynamics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A rapid stress-corrosion test for aluminum alloys

Stressed alloy specimens are immersed in a salt-dichromate solution at 60 degrees C. Because of the minimal general corrosion of these alloys in this solution, stress corrosion failures are detected by low-power microscopic examination.

Helfrich, W. J.↗

Refinement of Salt Dissolution Inhibitor Requirements (Interim Report)

At Savannah River Site, High-Level Waste is stored in below-grade carbon steel tanks. This waste in part consists of sludge, salt cake, and/or supernate. Preparation of this waste for future processing involves dissolution of the salt cake layer. The salt dissolution process can create conditions that leave the carbon steel tanks susceptible to localized corrosion. The salt to be dissolved contains high concentrations of nitrate, that once released, create an environment that may be conducive to pitting corrosion or stress corrosion cracking (SCC) of carbon steel. The salt dissolution process also liberates interstitial liquid trapped between the salt crystals. This liquid is initially high in nitrite and hydroxide concentration. High pH and greater ratios of nitrite to nitrate act as inhibitors to minimize corrosion of carbon steel in high nitrate environments. However, as dissolution proceeds, the concentration of nitrate increases while the hydroxide and nitrite concentration of the interstitial liquid depletes and becomes insufficient to prevent the onset of corrosion attack. While tank blending and the addition of inhibitors are used to ensure adequate concentrations of hydroxide and nitrite during normal operation, this is not desirable during salt dissolution as it can reduce process efficiency and increase the amount of waste that needs processed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Stress Relaxation Cracking of Alloys at Temperatures Higher Than 540°C

Type 347H stainless steel (347H SS), used in commercial concentrating solar power (CSP) thermal energy storage to store solar-salt at a temperature of 565°C, has been reported in the literature to be susceptible to stress-relaxation cracking (SRC). The welded heat-affected zone (HAZ) and fusion zone (FZ) of 347H SS, particularly in thick sections, are known to be susceptible to failure during post-weld heat treatment (reheat cracking). SRC could also occur after months or years under an elevated-temperature service environment. Two conditions must be present for failure to occur in the HAZ and/or FZ: 1) a modified or sensitized microstructure and 2) sufficiently high tensile residual stresses present at the elevated service temperature. The overarching goal of this project is to recommend SRC mitigation protocols to avoid susceptibility to fail through SRC at temperatures relevant for CSP. Post weld heat treatment conditions and alternative alloys are investigated as potential mitigation solutions to SRC. We used Gleeble thermomechanical simulation tests and finite element (FE) models to understand the susceptibility of 347H SS to SRC as a function of temperature, stress, and microstructure. We started with a literature review of weldability issues with 347H SS and techniques to mitigate SRC in 347H SS weldments. Next, we used Gleeble experiments to determine reheat cracking susceptibility in the simulated HAZ of 347SS weldments and an alternative alloy, 316L SS (NUCL 167 SPH) with boron added. We also performed Gleeble experiments to compare the reheat cracking susceptibility of 347H cross welded with two different fillers: E347, which is used in some commercial CSP TES tanks, and E16.8.2. We validated the experimental results with FE models of the residual stresses. We found that although the 316L (NUCL 167 SPH) is less susceptible to reheat cracking, it is slightly weaker than 347H and ASME BP&V codes limit its use to a service condition of 565°C. We also found that welds using E16.8.2 as the weld filler are less susceptible to failure than those using E347, likely due to the higher creep ductility of E16.8.2, and that it may be used as an alternative filler for repair welding of 347H welds or as the primary choice of filler for newly developed weld joints. We also found that post weld heat treatment could be a viable solution for mitigating stress in E347-347H SS thick, constrained welds, like those found in CSP tanks, and propose several options for mitigating SRC in existing and future TES tanks.

14 SOLAR ENERGY↗

Plating and Stripping of Lithium Metal Stabilized by a Block Copolymer Electrolyte: Local Current Density Measurement and Modeling

Here, plating and stripping of lithium protrusions in lithium metal symmetric cells containing a solid block copolymer electrolyte was studied as a function of time in 3D using time-resolved X-ray tomography. These measurements enabled determination of the spatial variation in current densities at the plating and stripping electrodes. The initial interelectrode distance was 27 μm. Correlation functions were calculated to reveal the relationships between current densities at the two electrodes and local electrolyte thickness. Current densities at opposing electrode locations during protrusion growth is uncorrelated until the local interelectrode distance decreases to less than 6 μm, just before the cell shorts. Mass balance was used to determine the area from which lithium ions that form a protrusion were stripped. Computational modeling of the plating and stripping process reveals the interplay between electrochemical and mechanical driving forces and their effect on nonuniform current distribution. Model predictions were compared with experiments without resorting to any adjustable parameters. The computed correlation functions were in qualitative agreement with experiments. Finally, the model was used to calculate contour plots of electrochemical potential within the electrolyte, shedding light on how geometry, salt concentration, interelectrode distance, and mechanical stress influence local rates of electrochemical reaction.

36 MATERIALS SCIENCE↗

Reaction Control System Thruster Cracking Consultation: NASA Engineering and Safety Center (NESC) Materials Super Problem Resolution Team (SPRT) Findings

The shuttle orbiter s reaction control system (RCS) primary thruster serial number 120 was found to contain cracks in the counter bores and relief radius after a chamber repair and rejuvenation was performed in April 2004. Relief radius cracking had been observed in the 1970s and 1980s in seven thrusters prior to flight; however, counter bore cracking had never been seen previously in RCS thrusters. Members of the Materials Super Problem Resolution Team (SPRT) of the NASA Engineering and Safety Center (NESC) conducted a detailed review of the relevant literature and of the documentation from the previous RCS thruster failure analyses. It was concluded that the previous failure analyses lacked sufficient documentation to support the conclusions that stress corrosion cracking or hot-salt cracking was the root cause of the thruster cracking and lacked reliable inspection controls to prevent cracked thrusters from entering the fleet. The NESC team identified and performed new materials characterization and mechanical tests. It was determined that the thruster intergranular cracking was due to hydrogen embrittlement and that the cracking was produced during manufacturing as a result of processing the thrusters with fluoride-containing acids. Testing and characterization demonstrated that appreciable environmental crack propagation does not occur after manufacturing.

MacKay, Rebecca A.↗

The ulcerogenic effect of bile and bile acid in rats during immobilization stress

The effect of different concentrations of oxen bile and individual bile acids or their sodium salts on the gastric mucosa of rats was investigated in combination with immobilization stress. A statistically significant higher frequency of ulcers was only determined in the application of 10% oxen bile. Dosages on 10% sodium glycocholic acid demonstrated strong toxic damage with atonic dilation of the stomach and extensive mucosal bleeding.

Weisener, J.↗

Stress corrosion evaluation of HP 9Ni-4Co-0.30C steel plate welds

A stress corrosion cracking (SCC) investigation was conducted on HP 9Ni-4Co-0.30C steel plate welds (welded by using straight polarity plasma arc and HP 9Ni-4Co-0.20C weld wire) since this material is being considered for use in the Advanced Solid Rocket Motor (ASRM) program. Prior to the welding, the material was double tempered at 538 C (1,000 F). After welding, only part of the material was stress relieved at 510 C (950 F) for 3 h. Round tensile specimens obtained from nonstress-relieved material were tested in 100-percent relative humidity at 38 C (100 F), in 3.5-percent NaCl alternate immersion, and in 5-percent salt spray at 35 C (95 F). Specimens obtained from stress-relieved material were tested in alternate immersion. The stress levels were 50, 75, and 90 percent of the corresponding 0.2-percent yield strength (YS). All the nonstress-relieved specimens exposed to salt spray and alternate immersion failed. Stress-relieved specimens (exposed to alternate immersion) failed at 75 and 90 percent of YS. No failures occurred at 50 percent of YS in the stress-relieved specimens which indicates a beneficial effect of the stress relief on the SCC resistance of these welds. The stress relief also had a positive effect on the mechanical properties of the welds (the most important being an increase of 21 percent on the YS). Under the conditions of these tests, the straight polarity plasma are welded HP 9Ni4Co-0.30C steel plate was found highly susceptible to SCC in the nonstress-relieved condition. This susceptibility to SCC was reduced by stress relieving.

Torres, Pablo D.↗