Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample minimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Accounting for Training Data Error in Machine Learning Applied to Earth Observations

Remote sensing, or Earth Observation (EO), is increasingly used to understand Earth system dynamics and create continuous and categorical maps of biophysical properties and land cover, especially based on recent advances in machine learning (ML). ML models typically require large, spatially explicit training datasets to make accurate predictions. Training data (TD) are typically generated by digitizing polygons on high spatial-resolution imagery, by collecting in situ data, or by using pre-existing datasets. TD are often assumed to accurately represent the truth, but in practice almost always have error, stemming from (1) sample design, and (2) sample collection errors. The latter is particularly relevant for image-interpreted TD, an increasingly commonly used method due to its practicality and the increasing training sample size requirements of modern ML algorithms. TD errors can cause substantial errors in the maps created using ML algorithms, which may impact map use and interpretation. Despite these potential errors and their real-world consequences for map-based decisions, TD error is often not accounted for or reported in EO research. Here we review the current practices for collecting and handling TD. We identify the sources of TD error, and illustrate their impacts using several case studies representing different EO applications (infrastructure mapping, global surface flux estimates, and agricultural monitoring), and provide guidelines for minimizing and accounting for TD errors. To harmonize terminology, we distinguish TD from three other classes of data that should be used to create and assess ML models: training reference data, used to assess the quality of TD during data generation; validation data, used to iteratively improve models; and map reference data, used only for final accuracy assessment. We focus primarily on TD, but our advice is generally applicable to all four classes, and we ground our review in established best practices for map accuracy assessment literature. EO researchers should start by determining the tolerable levels of map error and appropriate error metrics. Next, TD error should be minimized during sample design by choosing a representative spatio-temporal collection strategy, by using spatially and temporally relevant imagery and ancillary data sources during TD creation, and by selecting a set of legend definitions supported by the data. Furthermore, TD error can be minimized during the collection of individual samples by using consensus-based collection strategies, by directly comparing interpreted training observations against expert-generated training reference data to derive TD error metrics, and by providing image interpreters with thorough application-specific training. We strongly advise that TD error is incorporated in model outputs, either directly in bias and variance estimates or, at a minimum, by documenting the sources and implications of error. TD should be fully documented and made available via an open TD repository, allowing others to replicate and assess its use. To guide researchers in this process, we propose three tiers of TD error accounting standards. Finally, we advise researchers to clearly communicate the magnitude and impacts of TD error on map outputs, with specific consideration given to the likely map audience.

58 GEOSCIENCES↗

Electrostatic Discharge Testing of Carbon Composite Solar Array Panels for the Europa Mission to Jupiter

Carbon composite solar array panel coupons similar to those considered for use on the planned NASA Europa Mission were exposed to energetic electrons to observe the size and rate of electrostatic discharge production. The discharge size and rate were found to be primarily dependent on the quantity of dielectric binder pooled on the surface of the sample. Cooling the samples to cryogenic temperatures increased the size of discharges but an end of mission radiation dose had only minimal effects. Samples were composed of M55J carbon composite impregnated with an RS3 binder. Additional samples tested included a co-cured Kapton surface.

Green, Nelson W.↗

Nanopillar-based enhanced-fluorescence detection of sur-face-immobilized beryllium.

The unique properties associated with beryllium metal ensures the continued use in many industries despite the documented health and environmental risks. While engineered safeguards and personal protective equipment can reduce risks associated with working with the metal, it has been mandated by the Environmental Protection Agency (EPA) and Occupational Safety and Health Administration (OSHA) that the workplace air and surfaces must be monitored for toxic levels. While many methods have been developed to monitor levels down to the low μg/m 3 , the complexity and expense of these methods have driven the investigation into alternate methodologies. Herein, we use a combination of the previously developed fluorescence Be(II) ion detection reagent, 10-hydroxybenzo[h]quinoline (HBQ), with an optical field enhanced silicon nanopillar array, creating a new surface immobilized (si-HBQ) platform. The si-HBQ platform allows the positive control of the reagent for demonstrated reusability and a pillar diameter based tunable enhancement. Furthermore, native silicon nanopillars are overcoated with thin layers of porous silicon oxide to develop an analytical platform capable of a 0.0006 μg/L limit of detection (LOD) using sub-μL sample volumes. Additionally, we demonstrate a method to multiplex the introduction of the sample to the platform, with minimal 5.2% relative standard deviation (RSD) at 0.1 μg/L, to accommodate the potentially large number of samples needed to maintain industrial compliance. The minimal sample and reagent volumes and lack of complex and highly specific instrumentation, as well as positive control and reusability of traditionally consumable reagents, create a platform that is both accessible and economically advantageous.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An instrument for in situ coherent x-ray studies of metal-organic vapor phase epitaxy of III-nitrides

Here, we describe an instrument that exploits the ongoing revolution in synchrotron sources, optics, and detectors to enable in situ studies of metal-organic vapor phase epitaxy (MOVPE) growth of III-nitride materials using coherent x-ray methods. The system includes high-resolution positioning of the sample and detector including full rotations, an x-ray transparent chamber wall for incident and diffracted beam access over a wide angular range, and minimal thermal sample motion, giving the sub-micron positional stability and reproducibility needed for coherent x-ray studies. The instrument enables surface x-ray photon correlation spectroscopy, microbeam diffraction, and coherent diffraction imaging of atomic-scale surface and film structure and dynamics during growth, to provide fundamental understanding of MOVPE processes.

36 MATERIALS SCIENCE↗

Reduced electron exposure for energy-dispersive spectroscopy using dynamic sampling

Analytical electron microscopy and spectroscopy of biological specimens, polymers, and other beam sensitive materials has been a challenging area due to irradiation damage. There is a pressing need to develop novel imaging and spectroscopic imaging methods that will minimize such sample damage as well as reduce the data acquisition time. The latter is useful for high-throughput analysis of materials structure and chemistry. Here, in this work, we present a novel machine learning based method for dynamic sparse sampling of EDS data using a scanning electron microscope. Our method, based on the supervised learning approach for dynamic sampling algorithm and neural networks based classification of EDS data, allows a dramatic reduction in the total sampling of up to 90%, while maintaining the fidelity of the reconstructed elemental maps and spectroscopic data. In conclusion, we believe this approach will enable imaging and elemental mapping of materials that would otherwise be inaccessible to these analysis techniques.

36 MATERIALS SCIENCE↗

Soluble and Particulate Mercury Deployment of Analytical Method for the Savannah River Site Liquid Waste System

Savannah River National Laboratory (SRNL) developed, tested, and deployed in a radiological containment unit (CU) an analytical method for quantifying particulate total mercury and soluble total mercury in radioactive samples such as the those generated by the dilution of Savannah River Site (SRS) High-Level Waste. This method relies on direct mercury analysis and other associated capabilities for matrix independent quantification of total mercury in solids or liquids (i.e., any sample that can be introduced into the instrument oven for pyrolysis to release all mercury for measurement). The matrix independence allows for discreet measurements of the starting sample, the collected particulates and the filtrate liquid, thus enabling a mass balance quality check. For example, an analysis of a diluted sample from the SRS liquid waste system (LWS) resulted in a measured total mercury value of 55.0 mg Hg/L and a nearly matching calculated total mercury value of 55.1 mg Hg/L (± 20% 2σ) from the summation of measured soluble mercury (47.8 mg Hg/L ± 20% 2σ) and measured particulate mercury (7.26 mg Hg/L ± 20% 2σ). The advantages of the particulate-soluble mercury analysis method are: waste minimization using small radioactive liquid volumes, minimal radiological sample processing and reduced handling steps protective of workers (ALARA) and improved data quality, syringe filter technology which eliminates vacuum filtration and the potential loss of volatile species, small diameter filters (13 mm nominal to 25 mm if needed to avoid clogging) and small disposable poly filter holders (no need to clean) which minimize waste, flexibility provided for a range of starting concentrations, particulate-soluble ratios, and sample matrix conditions, soluble and particulate are measured results that, when summed, and are in good agreement with the total mercury measurement.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of the biofilm landscape of Bacillus subtilis by spatial microproteomics

Bulk proteomics has been demonstrated to differentiate subpopulations within bacterial colonies, yet advanced analyses by mass spectrometry imaging (MSI) hold even greater promise for the future. This technology can enable high-throughput spatial phenotyping that can reshape biological discovery by providing visualization of components of various biomolecular mechanisms. With high mass resolving power and high spatial resolution analyses being routine, we can confidently enable intact protein imaging directly from samples with minimal preparation. Pairing those analyses with bulk experimental libraries can provide high confidence in annotations of post-translational modifications (PTMs) and truncations. Revealing PTM localization within the samples unlocks a direct window into unknown biology at the microscale. However, top-down proteomics (TDP) is not commonplace for microbial species, largely due to challenges in identifying detected peptides and proteins; considering the theoretical proteome of even the well-studied model bacterium Bacillus subtilis was only partially mapped recently. With little still known about the form and function of many of these proteins – let alone proteoforms, where PTMs and truncations of the same protein may possess unique physiological roles – there is a wealth of work to be done. Here we jointly apply TDP and MSI to describe the microscale spatial proteomic landscape within B. subtilis and further demonstrate the feasibility of detecting differentiated subpopulations through proteoforms across the biofilm landscape.

bacterial biofilms↗

Design and Integration of a Compact Mobile Outdoor Soil Sampling Agricultural Robot

The lack of feedback on soil management for crop systems necessitates the collection of soil samples to derive insights into prevailing soil conditions. Achieving an accurate model of these plantations requires a substantial number of soil samples, which is a labor-intensive process that can suffer from inconsistencies in both the methodology of collection and the locations from which samples are gathered. In addition, the close spacing of crop rows constrains the maneuverability of mobile agricultural equipment during sample collection. This article proposes the use of agricultural robotics to facilitate the acquisition of composite soil samples with minimal human intervention, allowing for precise data collection for a Populus plant system. More specifically, this article presents a case study on the design and construction of a compact agricultural robot for soil sample collection. The performance of the robot, including its soil collection efficacy, maneuverability, and positional accuracy, is evaluated.

42 ENGINEERING↗

Sample size requirements for estimating effective dose from computed tomography using solid-state metal-oxide-semiconductor field-effect transistor dosimetry

Purpose: Effective dose (ED) is a widely used metric for comparing ionizing radiation burden between different imaging modalities, scanners, and scan protocols. In computed tomography (CT), ED can be estimated by performing scans on an anthropomorphic phantom in which metal-oxide-semiconductor field-effect transistor (MOSFET) solid-state dosimeters have been placed to enable organ dose measurements. Here a statistical framework is established to determine the sample size (number of scans) needed for estimating ED to a desired precision and confidence, for a particular scanner and scan protocol, subject to practical limitations. Methods: The statistical scheme involves solving equations which minimize the sample size required for estimating ED to desired precision and confidence. It is subject to a constrained variation of the estimated ED and solved using the Lagrange multiplier method. The scheme incorporates measurement variation introduced both by MOSFET calibration, and by variation in MOSFET readings between repeated CT scans. Sample size requirements are illustrated on cardiac, chest, and abdomen–pelvis CT scans performed on a 320-row scanner and chest CT performed on a 16-row scanner. Results: Sample sizes for estimating ED vary considerably between scanners and protocols. Sample size increases as the required precision or confidence is higher and also as the anticipated ED is lower. For example, for a helical chest protocol, for 95% confidence and 5% precision for the ED, 30 measurements are required on the 320-row scanner and 11 on the 16-row scanner when the anticipated ED is 4 mSv; these sample sizes are 5 and 2, respectively, when the anticipated ED is 10 mSv. Conclusions: Applying the suggested scheme, it was found that even at modest sample sizes, it is feasible to estimate ED with high precision and a high degree of confidence. As CT technology develops enabling ED to be lowered, more MOSFET measurements are needed to estimate ED with the same precision and confidence.

61 RADIATION PROTECTION AND DOSIMETRY↗

An interface for the direct coupling of small liquid samples to AMS

We describe the moving wire interface attached to the 1-MV AMS system at LLNL’s Center for Accelerator Mass Spectrometry for the analysis of nonvolatile liquid samples as either discrete drops or from the direct output of biochemical separatory instrumentation, such as high-performance liquid chromatography (HPLC). Discrete samples containing at least a few 10 s of nanograms of carbon and as little as 50 zmol 14 C can be measured with a 3–5% precision in a few minutes. The dynamic range of our system spans approximately 3 orders in magnitude. Sample to sample memory is minimized by the use of fresh targets for each discrete sample or by minimizing the amount of carbon present in a peak generated by an HPLC containing a significant amount of 14 C. As a result, liquid sample AMS provides a new technology to expand our biomedical AMS program by enabling the capability to measure low-level biochemicals in extremely small samples that would otherwise be inaccessible.

14C↗

Do Diurnal Aerosol Changes Affect Daily Average Radiative Forcing?

Strong diurnal variability of aerosol has been observed frequently for many urban/industrial regions. How this variability may alter the direct aerosol radiative forcing (DARF), however, is largely unknown. To quantify changes in the time-averaged DARF, we perform an assessment of 29 days of high temporal resolution ground-based data collected during the Two-Column Aerosol Project (TCAP) on Cape Cod, which is downwind of metropolitan areas. We demonstrate that strong diurnal changes of aerosol loading (about 20% on average) have a negligible impact on the 24-h average DARF, when daily averaged optical properties are used to find this quantity. However, when there is a sparse temporal sampling of aerosol properties, which may preclude the calculation of daily averaged optical properties, large errors (up to 100%) in the computed DARF may occur. We describe a simple way of reducing these errors, which suggests the minimal temporal sampling needed to accurately find the forcing.

aerosol↗

NifH -Harboring Bacterial Community Composition across an Alaskan Permafrost Thaw Gradient

Since nitrogen (N) is often limiting in permafrost soils, we investigated the N 2 -fixing genetic potential and the inferred taxa harboring those genes by sequencing nifH gene fragments in samples taken along a permafrost thaw gradient in an Alaskan boreal soil. Samples from minimally, moderately and extensively thawed sites were taken to a depth of 79 cm to encompass zones above and below the depth of the water table. NifH reads were translated with frameshift correction and 112,476 sequences were clustered at 5% amino acid dissimilarity resulting in 1,631 OTUs. Sample depth in relation to water table depth was correlated to differences in the NifH sequence classes with those most closely related to group I nifH -harboring Alpha- and Beta-Proteobacteria in higher abundance above water table depth while those related to group III nifH -harboring Delta Proteobacteria more abundant below. The most dominant below water table depth NifH sequences, comprising 1/3 of the total, were distantly related to Verrucomicrobia-Opitutaceae . Overall, these results suggest that permafrost thaw alters the class-level composition of N 2 -fixing communities in the thawed soil layers and that this distinction corresponds to the depth of the water table. These nifH data were also compared to nifH sequences obtained from a study at an Alaskan taiga site, and to those of other geographically distant, non-permafrost sites. The two Alaska sites were differentiated largely by changes in relative abundances of the same OTUs, whereas the non-Alaska sites were differentiated by the lack of many Alaskan OTUs, and the presence of unique halophilic, sulfate- and iron-reducing taxa in the Alaska sites.

54 ENVIRONMENTAL SCIENCES↗

Adjustable collimation for dark-field proton radiography contrast enhancement

A dark-field imaging condition established through pre- and post-object beam collimation has been tested for a variety of different settings at the proton radiography facility (pRad) at Los Alamos National Laboratory. This technique facilitates imaging of thin samples and materials with small areal density changes with 800 MeV protons that would otherwise appear nearly transparent for high energy protons. In the configuration that was examined, the pre-object (upstream) collimator is utilized to remove protons with large scattering angles prior to the target object. The post-object collimation entails a combination of a conventional collimator, which eliminates protons with large scattering angles after target interaction, and an inverse collimator. The inverse collimator removes unscattered protons traveling on the beam axis and those with smaller scattering angles up to a desired angle. This establishes a dark-field condition by permitting solely protons that exhibit scattering angles from target interaction within a designated range to contribute to the image. This study explores the potential of combining different sized collimators for pre- and post-object collimation. The objective is to optimize contrast for a range of samples with minimal areal density variations. A series of dark-field conditions are explored employing a remote-controlled collimator wheel and the contrast-to-noise ratio, spatial resolution, and proton transmission are compared for those combinations. It is found that the contrast-to-noise ratio can be substantially enhanced for thin samples and low areal density objects, thereby facilitating capturing high-contrast images of objects that were previously invisible to high energy protons.

43 PARTICLE ACCELERATORS↗

A novel flow cell for optical particle analyzers—application to measurements of Malvern Insitec under high pressure and temperature

A flow cell is a necessary measurement interface for some important optical analyzers. In our application of the flow cell, we utilize a state-of-the-art optical analyzer (Malvern Insitec) to measure particle size distribution and concentration in-situ in a sampled flow from a novel pressurized oxygen-fuel combustion process. However, since this sampling flow is a flow of moist flue gas under high temperature and pressure, and the flow contains particles and corrosive acid gases, it is an extreme challenge to obtain a flow cell with a high optical quality that does not perturb the measurement. To address this challenge, we propose a new design for an optical flow cell. By using a unique flow field in the proposed flow cell, the measurement zone can be well defined by the sampling flow, minimizing the influence of purge flow. To demonstrate this flow cell, we have built a test system, and conduct measurements utilizing polydisperse-particle standards (10-100 µm and 1-10 µm). The results reveal that the optical windows are well protected by the purge flow field, without risk of deposition from the sampling flow, and the Malvern Insitec can measure the particle size distribution by using this flow cell, without generating sample bias.

Cheng, Mao↗

SRNL Report on Vendor Solicitation and Selective Ion-Electrode Testing

Effective operation of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) will require information collected from sampling and/or monitoring to maintain environmental compliance, product quality, and operating efficiency. The U.S. Department of Energy (DOE) – Office of River Protection (ORP) recognizes the potential long-term benefit of developing real-time, in-line monitoring (RTIM) at the WTP to improve the current strategy of collecting tens of thousands of samples and analyzing them. In-line monitoring can decrease processing time associated with waiting for sample analysis, reduce workers’ exposure to radiation and chemical hazards, decrease secondary waste volumes, potentially improve product quality, and provide production support and enhance overall operational control. The Assistant Manager, WTP chartered an Integrated Technical Team (ITT), which includes personnel from the Savannah River National Laboratory (SRNL), Bechtel National, Inc., and DOE-ORP, to evaluate the capability and potential benefits of replacing routine sample collection requirements with real-time, in-line monitoring. The initial focus of the ITT is the Direct Feed Low Activity Waste (DFLAW) Program. This work scope is being performed in multiple phases. Phase 1 is Requirements and Opportunities Analysis, Phase 2 is Applications and Benefits Determination, and Phase 3 is Qualification and Demonstration. Phase 1 included 6 tasks and was completed by SRNL in 2017. The tasks in Phase 1 were: (1) determining the functional requirements for determining analytes and properties of streams, (2) determining the technical basis for process control, (3) determining the sampling points within the Low Activity Waste (LAW) facility and Effluent Management Facility (EMF), (4) data quality and management, (5) process control challenges, and (6) preparing a Preliminary Analysis Plan. DOE-ORP was briefed on the findings from the Phase 1 tasks and requested that Phase 2 work focus on establishing a basis for a materials balance approach that minimized process sampling. The Phase 2 work scope contains tasks to evaluate a materials balance only approach as well as continuing scoping evaluations for instruments that could be used for RTIM. The Phase 2 work scope was completed by both SRNL and Pacific Northwest National Laboratory (PNNL). The tasks performed in Phase 2 were: 1. Overall program administration and technical oversight 2. Evaluation of a Material Balance Approach, a. Evaluation of uncertainty of this approach compared to uncertainty of current methods b. Evaluation of automating the material balance within the framework of existing control software, c. Development of the methodology to obtain and evaluate data during cold commissioning to support a material balance approach, and d. Development of a framework to utilize during presentation of the revised approach to stakeholders and regulators. 3. Screening Evaluations of Instruments to Supplement the Material Balance Approach, a. AP-105 melter condensate evaluations, and b. Screening testing with simulants. 4. Evaluation of the current DFLAW feed qualification program to identify analytes that could be eliminated, a. Inorganic analytes, b. Radionuclides, and c. Organic analytes. This report describes the results of Task 3b, Screening testing with simulants. The Savannah River National Laboratory requested demonstrations of commercially available analytical instruments by the vendors or laboratory demonstration. The techniques tested included: Raman spectroscopy, Infrared spectroscopy (IR), laser induced breakdown spectroscopy (LIBS), X-Ray Fluorescence Spectroscopy (XRF), and ion-selective electrochemical probes. Additionally, the instrumentation would need to be durable enough to withstand the environment of the plant, preferably with little to no maintenance. The insertion point of the instrument would be dependent upon the instrumentation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

3D Motion of DNA-Au Nanoconjugates in Graphene Liquid Cell Electron Microscopy

Liquid-phase transmission electron microscopy (TEM) can probe and visualize dynamic events with structural or functional details at the nanoscale in a liquid medium. Prior efforts have focused on the growth and transformation kinetics of hard material systems, relying on their stability under electron beam. Our recently developed graphene liquid cell technique pushed the spatial resolution of such imaging to the atomic scale but still focused on growth trajectories of metallic nanocrystals. Here, we adopt this technique to imaging three-dimensional (3D) dynamics of soft materials instead, double strand (dsDNA) connecting Au nanocrystals as one example, at nanometer resolution. We show first that a graphene liquid cell can seal an aqueous sample solution of a lower vapor pressure than previously investigated well against the high vacuum in TEM. Then, from quantitative analysis of real time nanocrystal trajectories, we show that the status and configuration of dsDNA dictate the motions of linked nanocrystals throughout the imaging time of minutes. This sustained connecting ability of dsDNA enables this unprecedented continuous imaging of its dynamics via TEM. Moreover, the inert graphene surface minimizes sample-substrate interaction and allows the whole nanostructure to rotate freely in the liquid environment; we thus develop and implement the reconstruction of 3D configuration and motions of the nanostructure from the series of 2D projected TEM images captured while it rotates. In addition to further proving the nanoconjugate structural stability, this reconstruction demonstrates 3D dynamic imaging by TEM beyond its conventional use in seeing a flattened and dry sample. Altogether, we foresee the new and exciting use of graphene liquid cell TEM in imaging 3D biomolecular transformations or interaction dynamics at nanometer resolution.

3D motion↗

The Multispectral Microscopic Imager: Integrating Microimaging with Spectroscopy for the In-Situ Exploration of the Moon

To maximize the scientific return, future robotic and human missions to the Moon will need to have in-situ capabilities to enable the selection of the highest value samples for returning to Earth, or a lunar base for analysis. In order to accomplish this task efficiently, samples will need to be characterized using a suite of robotic instruments that can provide crucial information about elemental composition, mineralogy, volatiles and ices. Such spatially-correlated data sets, which place mineralogy into a microtextural context, are considered crucial for correct petrogenetic interpretations. . Combining microscopic imaging with visible= nearinfrared reflectance spectroscopy, provides a powerful in-situ approach for obtaining mineralogy within a microtextural context. The approach is non-destructive and requires minimal mechanical sample preparation. This approach provides data sets that are comparable to what geologists routinely acquire in the field, using a hand lens and in the lab using thin section petrography, and provide essential information for interpreting the primary formational processes in rocks and soils as well as the effects of secondary (diagenetic) alteration processes. Such observations lay a foundation for inferring geologic histories and provide "ground truth" for similar instruments on orbiting satellites; they support astronaut EVA activities and provide basic information about the physical properties of soils required for assessing associated health risks, and are basic tools in the exploration for in-situ resources to support human exploration of the Moon.

Nunez, J. I.↗

Montana Cropland Enrolled Farm Fields Carbon Sequestration Field Sampling, Measurement, Monitoring, and Verification: Application of Visible-Near Infrared Diffuse Reflectance Spectroscopy (VNIR) and Laser-induced Breakdown Spectroscopy (LIBS)

There is growing need for rapid, accurate, and inexpensive methods to measure, and verify soil organic carbon (SOC) change for national greenhouse gas accounting and the development of a soil carbon trading market. Laboratory based soil characterization typically requires significant soil processing, which is time and resource intensive. This severely limits application for large-region soil characterization. Thus, development of rapid and accurate methods for characterizing soils are needed to map soil properties for precision agriculture applications, improve regional and global soil carbon (C) stock and flux estimates and efficiently map sub-surface metal contamination, among others. The greatest gains for efficient soil characterization will come from collecting soil data in situ, thus minimizing soil sample transportation, processing, and lab-based measurement costs. Visible and near-infrared diffuse reflectance spectroscopy (VisNIR) and laser-induced breakdown spectroscopy (LIBS) are two complementary, yet fundamentally different spectroscopic techniques that have the potential to meet this need. These sensors have the potential to be mounted on a soil penetrometer and deployed for rapid soil profile characterization at field and landscape scales. Details of sensor interaction, efficient data management, and appropriate statistical analysis techniques for model calibrations are first needed. In situ or on-the-go VisNIR spectroscopy has been proposed as a rapid and inexpensive tool for intensively mapping soil texture and organic carbon (SOC). While lab-based VisNIR has been established as a viable technique for estimating various soil properties, few experiments have compared the predictive accuracy of on-the-go and lab-based VisNIR. Eight north central Montana wheat fields were intensively interrogated using on-the-go and lab-based VisNIR. Lab-based spectral data consistently provided more accurate predictions than on-the-go data. However, neither in situ nor lab-based spectroscopy yielded even semi-quantitative SOC predictions. There was little SOC variability to explain across the eight fields, and on-the-go VisNIR was not able to capture the subtle SOC variability in these Montana soils. With more variation in soil clay content compared to SOC, both lab and on-the-go VisNIR showed better explanatory power. There are several potential explanations for poor on-the-go predictive accuracy: soil heterogeneity, field moisture, consistent sample presentation, and a difference between the spatial support of on-the-go measurements and soil samples collected for laboratory analyses. Though the current configuration of a commercially available on-the-go VisNIR system allows for rapid field scanning, on-the-go soil processing (i.e. drying, crushing, and sieving) could improve soil carbon predictions. Laser-induced breakdown spectroscopy (LIBS) is an emerging elemental analysis technology with the potential to provide rapid, accurate and precise analysis of soil constituents, such as carbon, in situ across landscapes. The research team evaluated the accuracy of LIBS for measuring soil profile carbon in field-moist, intact soil cores simulating conditions that might be encountered by a probe-mounted LIBS instrument measuring soil profile carbon in situ. Over the course of three experiments, more than120 intact soil cores from eight north central Montana wheat fields and the Washington State University (WSU) Cook Agronomy Farm near Pullman, WA were interrogated with LIBS for rapid total carbon (TC), inorganic carbon (IC), and SOC determination. Partial least squares regression models were derived and independently validated at field- and regional scales. Researchers obtained the best LIBS validation predictions for IC followed by TC and SOC. Laser-induced breakdown spectroscopy is fundamentally an elemental analysis technique, yet LIBS PLS2 models appeared to discriminate IC from TC. Regression coefficients from initial models suggested a reliance upon stoichiometric relationships between carbon (247.8 nm) and other elements related to total and inorganic carbon in the soil matrix [Ca (210.2 nm, 211.3 nm, and 220.9 nm), Mg (279.55-280.4 nm, 285.26 nm), and Si (251.6 nm, 288.1 nm)]. Expanding the LIBS spectral range to capture emissions from a broader range of elements related to soil organic matter was explored using two spectrometer systems to improve SOC predictions. Results for increasing the spectral range of LIBS to the full 200-800 nm found modest gains in prediction accuracy for IC, but no gains for predicting TC or SOC. Poor SOC predictions are likely a function of (1) the lack of a consistent/definable molecular composition of SOC, (2) relatively little variation in SOC across field sites, and (3) inorganic carbon constituting the primary form of soil carbon, particularly for Montana soils.

54 ENVIRONMENTAL SCIENCES↗