Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample size”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Tools for Water Ingress Testing

The Safety Storage and Engineering Team, as part of the Production Support Services division (PSS-2), is tasked with ensuring the safety of containers used for handling and storage of nuclear materials. As part of this work, water ingress tests are conducted to evaluate the water-tightness of containers intended for in-glovebox use. In collaboration, the statistics group of the Computer and Computational Sciences Division (CCS-6) provided support in developing a statistically defensible approach for determining appropriate sample sizes for water ingress testing. Water ingress testing involves multiple measurements on multiple containers. Our approach uses a simple random effects model to analyze a pilot data set, implementing prediction limits to evaluate the efficacy of collecting additional data. Although this study capitalizes on available data, our approach can be used with estimates of the ratio of between and within variability and average values, often available from past testing or expert knowledge. An interactive Shiny tool was developed as a final user-friendly product for future testing. The Shiny interface is an open-source package providing a framework for building web applications. Raw data exploration and prediction interval-based sample size assessments can quickly be conducted by the engineering team without needing to interact with the underlying code.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Uncertainty quantification of fiber orientation distribution measurements for long-fiber-reinforced thermoplastic composites

We present a detailed methodology for experimental measurement of fiber orientation distribution (FOD) in injection-molded discontinuous fiber composites using the method of ellipses on 2D cross sections. Best practices to avoid biases occurring during surface preparation and optical imaging of carbon-fiber-reinforced thermoplastics are discussed. A marker-based watershed transform routine for efficient image segmentation and the separation of touching fiber ellipses is developed. The sensitivity of the averaged orientation tensor to the image sample size is studied for the case of long-fiber thermoplastics. A Mori-Tanaka implementation of the Eshelby model is then employed to quantify the sensitivity of elastic stiffness predictions to biases in the FOD measurements.

fiber orientation distribution measurement↗

A multivariate approach to ensure statistical reproducibility of climate model simulations

Effective utilization of novel hybrid architectures of pre-exascale and exascale machines requires transformations to global climate modeling systems that may not reproduce the original model solution bit-for-bit. Round-off level differences grow rapidly in these non-linear and chaotic systems. This makes it difficult to isolate bugs/errors from innocuous growth expected from round-off level differences. Here, we apply two modern multivariate two sample equality of distribution tests to evaluate statistical reproducibility of global climate model simulations using standard monthly output of short (~ 1-year) simulation ensembles of a control model and a modified model of US Department of Energy's Energy Exascale Earth System Model (E3SM). Both the tests are able to identify changes induced by modifications to some model tuning parameters. We also conduct formal power analyses of the tests by applying them on designed suites of short simulation ensembles each with an increasingly different climate from the control ensemble. The results are compared against those from another such test. These power analyses provide a framework to quantify the degree of differences that can be detected confidently by the tests for a given ensemble size (sample size). This will allow model developers using the tests to make an informed decision when accepting/rejecting an unintentional non-bit-for-bit change to the model solution.

Mahajan, Salil↗

THE BARYONIC ACOUSTIC FEATURE AND LARGE-SCALE CLUSTERING IN THE SLOAN DIGITAL SKY SURVEY LUMINOUS RED GALAXY SAMPLE

We examine the correlation function xi of the Sloan Digital Sky Survey Luminous Red Galaxy sample at large scales (60 h {sup -1} Mpc < s < 400 h {sup -1} Mpc) using the final data release (DR7). Focusing on a quasi-volume-limited (0.16 < z < 0.36) subsample and utilizing mock galaxy catalogs, we demonstrate that the observed baryonic acoustic peak and larger scale signal are consistent with LAMBDACDM at 70%-95% confidence. Fitting data to a non-linear, redshift-space, template-based model, we constrain the peak position at s{sub p} = 101.7+- 3.0 h {sup -1} Mpc when fitting the range 60 h {sup -1} Mpc < s < 150 h {sup -1} Mpc (1sigma uncertainties). This redshift-space distance s{sub p} is related to the comoving sound horizon scale r{sub s} after taking into account matter-clustering non-linearities, redshift distortions, and galaxy-clustering bias. Mock catalogs show that the probability that a DR7-sized sample would not have an identifiable peak is at least {approx}10%. As a consistency check of a fiducial cosmology, we use the observed s{sub p} to obtain the distance D{sub V}{identical_to}((1+z){sup 2}D{sup 2}{sub A}cz/H(z)){sup 1/3} relative to the acoustic scale. We find r{sub s} /D{sub V} (z = 0.278) = 0.1389 +- 0.0043. This result is in excellent agreement with Percival et al., who examine roughly the same data set, but use the power spectrum. Comparison with other determinations in the literature are also in very good agreement. The signal of the full sample at 125 h {sup -1} Mpc < s < 200 h {sup -1} Mpc tends to be high relative to theoretical expectations; this slight deviation can probably be attributed to sample variance. We have tested our results against a battery of possible systematic effects, finding all effects are smaller than our estimated sample variance.

79 ASTRONOMY AND ASTROPHYSICS↗

Human Lacrimal Production Rate and Wetted Length of Modified Schirmer's Tear Test Strips

Purpose: To assess and compare the wetting kinetics of sheathed and unsheathed Schirmer's tear test (STT) strips, and to determine the repeatability of 5-minute wetted length (WL) and basal tear production rate (BTPR). Methods:Seventeen subjects underwent two sheathed and unsheathed STTs each for both eyes on four visits on separate days. After administration of topical anesthetic, WLs were measured every 30 seconds for 5 minutes, and BTPRs were calculated for sheathed strips. Limits of agreement (LoA), difference-versus-mean plots (DVM), and the coefficient of repeatability (CR) assessed WL and BTPR repeatabilities. Variance estimates were used to calculate sample sizes for future study. Results: For the unsheathed STT, the mean (SD) difference in WLs between visits was 0.74 (5.05) mm, LoA were [-9.17, 10.64], and CR was 9.17 mm; for the sheathed STT, the mean (SD) intervisit difference was 0.16 (5.94) mm, LoA were [-11.49, 11.8], and CR was 10.53 mm. Eight of 48 sheathed STTs and 20 of 44 unsheathed STTs showed constant WL for the final 90 seconds of the test. The mean (SD) difference between repeated visits for BTPR was approximately 0.0 μL/min, LoA were [-1.82, 1.82], and CR was 1.91 μL/min. Conclusions: Repeatability of sheathed and unsheathed 5-minute WL and BTPR is inadequate for measuring within-subject changes, but is sufficient for group studies with moderate sample sizes. Constant WL for the fiant WL with the unsheathed STT can be explained by balancing evaporation and BTPR. Translational Relevance: Repeatability of the modified STT is evaluated clinically to establish quantitative BTPRs rather than inference from a strip WL.

59 BASIC BIOLOGICAL SCIENCES↗

Cu2ZnSnSe4 Photovoltaic Absorber Layers Evaluated by Transmission X-Ray Microscopy Tomography: Composition Fluctuations on the Length Scale of Grains

The origins of open-circuit voltage deficits in Cu2ZnSnS(e)4-based solar cells have been an intense topic of research over the past few years as device efficiencies have never approached those of CuInGaSe2 based cells despite the materials sharing similar crystal and electronic structures. In this work, we use transmission X-ray microscopy tomography to investigate the length scales over which elemental fluctuations occur. We find and show evidence of micron-scale Cu to Zn anti-correlations over a previously inaccessible combination of resolution and sample size that is consistent with the length scale of grains in this material. This result yields further insight into the causes of the large open-circuit voltage deficits regularly seen in these devices as well as the challenges of achieving compositional homogeneity in this material.

composition fluctuations↗

Macroinvertebrate Abundance and Biomass: 2007 Data, BPA-51; Preliminary Report, February 10, 2009..

Four Excel files containing information on the 2007 macroinvertebrate data were initially provided to Statistical Consulting Services (SCS) by EcoAnalysts on 1/27/2009. These data files contained information on abundance and biomass data at the level of taxonomic groups. The data were subsequently reformatted and compiled, and aggregated for analysis by SCS. All descriptions and analyses below relate to this compiled data. Computations were carried out separately for each site over all sample periods. Basic summary information for both the abundance and biomass data is presented in Print Out No.2. The 14 sites varied widely in their minimum, mean, maximum and variance values. The number of observations ranged from 10 to 18. Some large abundance values (abundance > 40,000) were noted for sites KR6 and KR13. A more detailed summary of each site is given in Print Out No.3. Site KR3, for example, had a mean abundance of 6914 with a sample size of 17. The variance was 4591991 and the standard error of the mean was 1643. The skewness value, a measure of symmetry for the frequency distribution, was moderately large at 1.29 indicating an asymmetric distribution. Biomass for KR3 had a mean value of 0.87 g/m{sup 2} with 17 observations. The variance was 0.8872 and the standard error was 0.228 g/m{sup 2}. Skewness for biomass was also high at 1.29. Further examination of the quantiles and frequency plots for abundance and biomass also indicate considerable skewness. The stem and leaf diagram (frequency plot) for abundance in KR3 shows most of the data centered on smaller values with a few very large counts. The distribution for biomass has a similar pattern. Statistical tests for normality are significant for both response variables in KR3, thus, the hypothesis that the data originates from a symmetric normal distribution is rejected. Because sample size estimation and statistical inference assume normally distributed data, a transformation of the data is required prior to further analysis. As was the case for previous years, the natural logarithm was chosen as a transformation to mitigate distributional skewness. Abundance and biomass for the remaining sites were also notably skewed, therefore, these data were also log transformed prior to analysis. Summary information for the transformed data (referred to as L-abun and L-bio for abundance and biomass, respectively) are given in Print Out No.4. For site KR3, the logarithmic transformation reduced skewness value for biomass to -0.66. The distributions of abundance and biomass in the other sites also generally showed improvement as well. Hence, all subsequent statistical analyses reported here will be based on the log transformed data.

13 HYDRO ENERGY↗

The Evolution of Randomized Clinical Trial Designs to Assess Therapeutics in Alzheimer Disease

Importance The success of recent randomized clinical trials (RCTs) for Alzheimer disease (AD), particularly those focusing on anti-amyloid therapies, has been discussed at length. However, the evolution of RCT design features for AD that preceded this success remain underexplored. Objective To describe temporal changes in the features of RCT design for interventions in AD. Evidence Review PubMed, Scopus, and Web of Science databases were searched in January 2025 for phase 2 and 3 AD RCTs published between January 1992 and December 2024. RCTs that investigated an intervention for AD, with a placebo or standard-of-care control group, were included. Four assessors independently reviewed full-text articles to capture study characteristics. Main Outcomes and Measures The number of participants and the duration of RCTs as well as the target population, outcomes, and funding were extracted from published reports. These features were analyzed with respect to time using linear regression and χ 2 analyses. Results The study included 203 RCTs with 79 589 participants testing interventions in AD. From 1992 to 2024, the mean sample size increased by 464% for phase 2 RCTs (from 42 to 237), and 50% for phase 3 RCTs (from 632 to 951), while the mean trial duration increased by 188% (from 16 to 46 weeks) for phase 2, and 256% (from 20 to 71 weeks) for phase 3 RCTs. This longer duration of RCTs may be partially attributed by a greater share of disease-modifying rather than symptomatic treatments. Similarly, more recent trials required AD biomarker evidence for enrollment (from 1 of 36 [2.7%] before 2006 to 40 of 76 [52.6%] since 2019). A substantial difference in the type of therapeutics researched was observed, with anti-amyloid and anti-tau RCTs being more likely to be funded by the pharmaceutical industry compared with neurotransmitter or other RCTs (anti-amyloid or anti-tau, 68 of 71 [95.8%]; neurotransmitter, 52 of 69 [77.6%]; other, 33 of 52 [63.5%]). RCT transparency improved, with more frequent data accessibility statements, registered reports, and better reporting on race and ethnicity. Conclusions and Relevance This methodology research of AD RCTs highlights substantial changes in key features of AD clinical trials from 1992 to 2024. AD RCTs have become larger and longer, such that they are powered to detect smaller clinical differences. The increased sample sizes and duration should enable the detection of smaller and more slowly occurring outcomes, which may lead to successful RCTs of therapies with slower and more subtle efficacy.

General & Internal Medicine↗

Nonequilibrium defect-phase nanostructures stabilized by irradiation in undersaturated Ni-Si nanocrystalline alloy

Nanocrystalline thin films of the undersaturated alloy Ni-8.5 at% Si were subjected to 2 MeV Ti irradiation at temperatures ranging from 450˚C to 550˚C. Correlative microscopy combining transmission electron microscopy (TEM), scanning-TEM and atom probe tomography (APT revealed that large dose irradiation at 450˚C of samples with initial grain sizes below 100 nm stabilized a novel nanostructure which surprisingly contained three co-existing phases, the γ face-centered-cubic (FCC) matrix, γ' L12 ordered precipitates on intragranular dislocation loops and Ni 31 Si 12 precipitates at triple junctions (TJs). In contrast, irradiation at 550˚C and irradiation of larger grain-size samples at 450˚C only produced a γ-γ' two-phase coexistence. Analysis of the three-phase nanostructure and phase field simulations indicates that radiation-induced segregation is most pronounced at TJs, thus triggering the formation of Ni 31 Si 12 precipitates. These incoherent precipitates, in turn, are expected to stabilize the grain size under irradiation. The results are generalized using the concept of driven defect-phases. It is suggested that the stabilization of driven defect-phases may impart radiation resilience by providing localized relaxation modes to the microstructure evolution during and after temporary perturbations in irradiation conditions.

36 MATERIALS SCIENCE↗

A search for anisotropy in the arrival directions of ultra high energy cosmic rays recorded at the Pierre Auger Observatory

Observations of cosmic ray arrival directions made with the Pierre Auger Observatory have previously provided evidence of anisotropy at the 99% CL using the correlation of ultra high energy cosmic rays (UHECRs) with objects drawn from the Véron-Cetty Véron catalog. In this paper we report on the use of three catalog independent methods to search for anisotropy. The 2pt–L, 2pt+ and 3pt methods, each giving a different measure of self-clustering in arrival directions, were tested on mock cosmic ray data sets to study the impacts of sample size and magnetic smearing on their results, accounting for both angular and energy resolutions. If the sources of UHECRs follow the same large scale structure as ordinary galaxies in the local Universe and if UHECRs are deflected no more than a few degrees, a study of mock maps suggests that these three methods can efficiently respond to the resulting anisotropy with a P-value = 1.0% or smaller with data sets as few as 100 events. Using data taken from January 1, 2004 to July 31, 2010 we examined the 20,30,...,110 highest energy events with a corresponding minimum energy threshold of about 49.3 EeV. The minimum P-values found were 13.5% using the 2pt-L method, 1.0% using the 2pt+ method and 1.1% using the 3pt method for the highest 100 energy events. In view of the multiple (correlated) scans performed on the data set, these catalog-independent methods do not yield strong evidence of anisotropy in the highest energy cosmic rays.

79 ASTRONOMY AND ASTROPHYSICS↗

The effect of lighting environment on task performance in buildings – A review

The effects of indoor environmental conditions on human health, satisfaction, and performance have been the focal point of research for decades. This paper reviews and summarizes the impact of lighting environment on task performance, specifically for the built environment audience. Existing studies included a variety of performance tests on cognitive performance and perception, visual acuity and reaction, memory, reasoning, and labor productivity. Illuminance, luminance ratio and correlated color temperature were found to affect performance in different ways, reflecting the impact of experimental techniques, conditions, performance evaluation methods used and data analysis methods. These were reviewed and categorized, with discussion on limitations related to sample size, modeling approach, carryover effects and other factors affecting individual differences in performance, with recommendations for future improvement. Although no universal conclusions can be made, in general, task performance seems to improve with higher illuminances, contrast ratios in the range of 7–11:1 (while always making sure that glare will not occur in the space) and higher correlated color temperature, while spectral tuning in the red or blue wavelengths has also shown positive effects. To obtain more generic evidence, future studies should be more consistent in terms of experimental procedures and overall light conditions, and also consider the effects of vertical illuminance, daylight provision/control, and outside views on task performance. Finally, studying performance with multi-factorial designs in a human-centered optimized manner (such as deploying variable lighting scenarios optimized for various tasks) can lead to deeper understanding of lighting effects on task performance, and ultimately to improved lighting design and operation in buildings overall.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A lathe system for micrometre-sized cylindrical sample preparation at room and cryogenic temperatures

A simple two-spindle based lathe system for the preparation of cylindrical samples intended for X-ray tomography is presented. The setup can operate at room temperature as well as under cryogenic conditions, allowing the preparation of samples down to 20 and 50 µm in diameter, respectively, within minutes. Case studies are presented involving the preparation of a brittle biomineral brachiopod shell and cryogenically fixed soft brain tissue, and their examination by means of ptychographic X-ray computed tomography reveals the preparation method to be mainly free from causing artefacts. Since this lathe system easily yields near-cylindrical samples ideal for tomography, a usage for a wide variety of otherwise challenging specimens is anticipated, in addition to potential use as a time- and cost-saving tool prior to focused ion-beam milling. Fast sample preparation becomes especially important in relation to shorter measurement times expected in next-generation synchrotron sources.

36 MATERIALS SCIENCE↗

Scaling of EPR spectral-spatial images with size of sample: Images of a sample greater than 5 cm in linear dimension

The authors have obtained spectral-spatial EPR images of a phantom significantly larger than those previously obtained. Images of a homogeneous phantom 4.2 cm in diameter and 6.5 cm in length with B{sub 1} equivalent to that used for smaller samples give a similar linewidth resolution both with linewidth population distributions of width 0.1 {mu}T. Spatial resolution appeared to have modest degradation. Images of the large homogeneous phantom provide maps of the magnetic field of a partially shimmed magnet.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enhancement of Structural Health Monitoring Framework by Optimizing Vibro-Acoustic Modulation Technique to Localize Alkali-Silica Reaction Degradation in Medium-Sized Concrete Samples

Assessment and management of aging concrete structures in nuclear power plants require a more systematic approach than simple reliance on existing code margins of safety. Health monitoring of concrete structures is performed to understand the current condition of a structure based on heterogeneous measurements and then produce high confidence actionable information regarding structural integrity. This information can then be used to support operational and maintenance decisions. The objectives of this ongoing research project focus on health monitoring and data analytics of concrete slabs containing reactive aggregates and thus subjected to degradation due to alkali-silica reaction (ASR). A controlled concrete slab with four pockets of reactive aggregates (pure silica, wells, placitas, and spratt) was cast at Vanderbilt University and cured in representative conditions to accelerate degradation due to ASR. A set of four concrete samples were also cast and cured at the University of Alabama for ASR testing. Of these four samples, two slabs contained reactive aggregates while the other two had the non-reactive aggregate counterparts mixed throughout the samples. Vibro-acoustic methods were used on these slabs to locate large pockets of ASR within the reactive samples and determine the effects of rebar using the non-reactive slabs. Vibro-acoustic modulation (VAM) is a vibration-based NDE method that utilizes signatures of nonlinear dynamic interactions on contact surfaces of crack or delamination damage to detect and localize the damage. VAM analysis was conducted on both Vanderbilt and Alabama’s samples using multiple variables for damage detection and localization. The results from the data analysis of the NDE vibro-acoustic techniques on concrete slabs cured at Vanderbilt University and the University of Alabama are discussed in detail in this report. The major outcome of the analysis suggests that the VAM method can be used to detect damage within the concrete samples by comparing the results found in different sections of the samples. Results for damage localization are dependent on multiple variables used in the vibro-acoustic modulation experiments. Digital image correlation (DIC) is a three-dimensional, full-field, optical NDE technique to measure contour, deformation, vibration, and strain. The application of the digital image correlation technique to study ASR-related degradation on a large concrete sample at the University of Tennessee Knoxville is discussed and observations are presented in this report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Uncertainty Quantification in Vibro-Acoustics Diagnosis of Alkali-Silica Reaction Degradation in Medium-Sized Concrete Samples

The objectives of this ongoing research project focus on health monitoring and data analytics of concrete slabs containing reactive aggregates and thus subjected to degradation due to alkali-silica reaction (ASR). A controlled concrete slab with four pockets of reactive aggregates (pure silica, wells, placitas, and spratt) was cast at Vanderbilt University and cured in representative conditions to accelerate degradation due to ASR. A set of four concrete samples were also cast and cured at the University of Alabama for ASR testing. Of these four samples, two slabs contained reactive aggregates while the other two had the non-reactive aggregate counterparts mixed throughout the samples. Vibro-acoustic testing was used on these slabs to locate ASR damage within the reactive samples. Vibro-acoustic modulation (VAM) is a vibration-based NDE method that utilizes signatures of nonlinear dynamic interactions on contact surfaces of crack or delamination damage to detect and localize the damage. VAM analysis was conducted on both the Vanderbilt and Alabama samples using multiple variables for damage detection and localization. The results from the data analysis of the vibro-acoustic testing on concrete slabs cured at Vanderbilt University and the University of Alabama are discussed in detail in this report. Results for damage localization are dependent on multiple variables used in the vibro-acoustic modulation experiments. A major focus of this report is to quantify the uncertainty in the diagnosis due to multiple factors and uncertainty sources. The uncertainty quantification methodology presented in this report was applied to VAM-based diagnosis and prognosis. However, the methodology is general, and is capable of being applied to multiple technique that collect spatially distributed data. Future work needs to investigate the incorporation of uncertainty quantification in developing a robust Prognostics and Health Management framework. Digital image correlation is a three-dimensional, full-field, optical NDE technique to measure contour, deformation, vibration, and strain. The application of the digital image correlation technique to study ASR-related degradation on a large concrete specimen at the University of Tennessee is discussed and observations are presented in this report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Artificial Intelligence and Machine Learning Support for Probabilistic Fracture Mechanics

In this research, artificial intelligence and machine learning (ML) methods are used to search an uncertain parameter space more efficiently for the most important inputs with respect to response sensitivities. These methods are applied to the Extremely Low Probability of Rupture (xLPR) probabilistic fracture mechanics code used at the U.S. Nuclear Regulatory Commission (NRC) in support of nuclear regulatory research. This report documents two separate but related sub-tasks: (1) ranking important uncertain input features with respect to target outputs, determined by convergence in confidence intervals for increasing sample sizes using simple random sampling; and (2) implementation of a reduced-order surrogate model for fast, approximate sample generation. Unoptimized readily available off-the-shelf ML models were used in both sub-tasks.

97 MATHEMATICS AND COMPUTING↗

Elemental Mixing State of Aerosol Particles Collected in Central Amazonia during GoAmazon2014/15

Two complementary techniques, Scanning Transmission X-ray Microscopy/Near Edge Fine Structure spectroscopy (STXM/NEXAFS) and Scanning Electron Microscopy/Energy Dispersive X-ray spectroscopy (SEM/EDX), have been quantitatively combined to characterize individual atmospheric particles. This pair of techniques was applied to particle samples at three sampling sites (ATTO, ZF2, and T3) in the Amazon basin as part of the Observations and Modeling of the Green Ocean Amazon (GoAmazon2014/5) field campaign during the dry season of 2014. The combined data was subjected to k-means clustering using mass fractions of the following elements: C, N, O, Na, Mg, P, S, Cl, K, Ca, Mn, Fe, Ni, and Zn. Cluster analysis identified 12 particle types, across different sampling sites and particle sizes. Samples from the remote Amazon Tall Tower Observatory (ATTO, also T0a) exhibited less cluster variety and fewer anthropogenic clusters than samples collected at the sites nearer to the Manaus metropolitan region, ZF2 (also T0t) or T3. Samples from the ZF2 site contained aged/anthropogenic clusters not readily explained by transport from ATTO or Manaus, possibly suggesting the effects of long range atmospheric transport or other local aerosol sources present during sampling. In addition, this data set allowed for recently established diversity parameters to be calculated. All sample periods had high mixing state indices (χ) that were >0.8. Two individual particle diversity (D i ) populations were observed, with particles <0.5 μm having a D i of ~2.4 and >0.5 μm particles having a D i of ~3.6, which likely correspond to fresh and aged aerosols respectively. The diversity parameters determined by the quantitative method presented here will serve to aid in the accurate representation of aerosol mixing state, source apportionment, and aging in both less polluted and more industrialized environments in the Amazon Basin.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Waste reduction and process improvements in the analysis of plutonium by x-ray fluorescence

Significant modifications were made to a sample preparation process for quantifying gallium in plutonium metal by wavelength dispersive X-ray fluorescence. These changes were made to minimize waste and improve process safety and efficiency. Sample sizes were reduced, cheaper sample preparation acids were used, and safety improvements were implemented. Using this modified process, results from analyzing a batch oftest samples indicated that relative precision and accuracy were {approx}0.2% and {approx}0.1% respectively, which is comparable to that obtained using the older, established sample preparation method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗