Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample thickness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

A New Electromagnetic Instrument for Thickness Gauging of Conductive Materials

Eddy current techniques are widely used to measure the thickness of electrically conducting materials. The approach, however, requires an extensive set of calibration standards and can be quite time consuming to set up and perform. Recently, an electromagnetic sensor was developed which eliminates the need for impedance measurements. The ability to monitor the magnitude of a voltage output independent of the phase enables the use of extremely simple instrumentation. Using this new sensor a portable hand-held instrument was developed. The device makes single point measurements of the thickness of nonferromagnetic conductive materials. The technique utilized by this instrument requires calibration with two samples of known thicknesses that are representative of the upper and lower thickness values to be measured. The accuracy of the instrument depends upon the calibration range, with a larger range giving a larger error. The measured thicknesses are typically within 2-3% of the calibration range (the difference between the thin and thick sample) of their actual values. In this paper the design, operational and performance characteristics of the instrument along with a detailed description of the thickness gauging algorithm used in the device are presented.

Fulton, J. P.↗

Processing Waveform-Based NDE

A computer implemented process for simultaneously measuring the velocity of terahertz electromagnetic radiation in a dielectric material sample without prior knowledge of the thickness of the sample and for measuring the thickness of a material sample using terahertz electromagnetic radiation in a material sample without prior knowledge of the velocity of the terahertz electromagnetic radiation in the sample is disclosed and claimed. Utilizing interactive software the process evaluates, in a plurality of locations, the sample for microstructural variations and for thickness variations and maps the microstructural and thickness variations by location. A thin sheet of dielectric material may be used on top of the sample to create a dielectric mismatch. The approximate focal point of the radiation source (transceiver) is initially determined for good measurements.

Roth, Donald J↗

Simultaneous determination of electrical conductivity and thickness of nonmagnetic metallic foils using two-sided multifrequency eddy current techniques

Here, in this paper, we describe a simple method for performing multifrequency eddy current characterization of free-standing uniform-thickness metallic foils using a forked inductive coil arrangement. The method involves measuring the mutual inductance between two coils when a foil is present between the coils, and when it is not present; the ratio of these mutual inductances is compared with an analytical solution, and foil conductivity, thickness, and sheet resistance are simultaneously estimated using numerical inversion and least-squares fitting. This method was used to characterize 34 non-ferrous metallic samples with thicknesses between 50 and 640 μm and with conductivities between 0.8 × 10 7 and 5.8 × 10 7 S/m. The estimated thicknesses from eddy current characterization agreed well with those measured using confocal optical techniques; the two approaches agreed to within 1 μm for samples that were thinner than 200 μm, and to within 0.5% for samples that had a thickness of 200 μm or greater. The estimated conductivities from eddy current characterization were in close agreement with expected values, given knowledge of the materials used. A particular strength of this approach is that the instrumentation needed is broadly available in research and development laboratories and the associated fixturing is easy to manufacture and assemble. A calibration procedure is described that can be used to reduce errors from geometric uncertainties. This calibration requires a sample that has only a known conductivity or thickness; both do not need to be known. The method described herein is likely extensible to conductivities and thickness well outside the ranges measured as part of this work.

47 OTHER INSTRUMENTATION↗

Results of Large-Scale Spacecraft Flammability Tests

For the first time, a large-scale fire was intentionally set inside a spacecraft while in orbit. Testing in low gravity aboard spacecraft had been limited to samples of modest size: for thin fuels the longest samples burned were around 15 cm in length and thick fuel samples have been even smaller. This is despite the fact that fire is a catastrophic hazard for spaceflight and the spread and growth of a fire, combined with its interactions with the vehicle cannot be expected to scale linearly. While every type of occupied structure on earth has been the subject of full scale fire testing, this had never been attempted in space owing to the complexity, cost, risk and absence of a safe location. Thus, there is a gap in knowledge of fire behavior in spacecraft. The recent utilization of large, unmanned, resupply craft has provided the needed capability: a habitable but unoccupied spacecraft in low earth orbit. One such vehicle was used to study the flame spread over a 94 x 40.6 cm thin charring solid (fiberglasscotton fabric). The sample was an order of magnitude larger than anything studied to date in microgravity and was of sufficient scale that it consumed 1.5 of the available oxygen. The experiment which is called Saffire consisted of two tests, forward or concurrent flame spread (with the direction of flow) and opposed flame spread (against the direction of flow). The average forced air speed was 20 cms. For the concurrent flame spread test, the flame size remained constrained after the ignition transient, which is not the case in 1-g. These results were qualitatively different from those on earth where an upward-spreading flame on a sample of this size accelerates and grows. In addition, a curious effect of the chamber size is noted. Compared to previous microgravity work in smaller tunnels, the flame in the larger tunnel spread more slowly, even for a wider sample. This is attributed to the effect of flow acceleration in the smaller tunnels as a result of hot gas expansion. These results clearly demonstrate the unique features of purely forced flow in microgravity on flame spread, the dependence of flame behavior on the scale of the experiment, and the importance of full-scale testing for spacecraft fire safety.

microgravity↗

Three Photon Excited Image Scanning Microscopy for in-Depth Super-Resolution Studies of Biological Samples

Multiphoton laser scanning microscopy is a powerful tool for deep imaging of thick biological samples. Image scanning microscopy (ISM) has demonstrated significant improvements in the signal-to-noise ratio in confocal laser scanning microscopy, while at the same time improving upon the effectively attainable resolution. Two-photon excitation (2PE), combined with ISM, has been shown to allow for deep tissue imaging with enhanced resolution compared to 2PE microscopy. Three-photon excitation (3PE) has enabled record imaging depth and contrast for multiphoton imaging, due to the superior suppression of out-of-focus signal generation. In this paper, we demonstrate super-resolution 3PE ISM. This is achieved using a single-photon avalanche detector array, and 1040-nm pulses for 3PE of blue fluorescence. This method enables subdiffraction limited resolution imaging of biological samples stained with blue fluorescent markers, such as mouse myocardial and spinal cord tissues stained with 4 ′ , 6 -diamidino-2-phenylindole. Deconvolution improves the resolving power further and allows for imaging with better than λ / 8 resolution with respect to the 3PE wavelength λ . With the ISM pixel reassignment procedure, we demonstrate a resolution enhancement of ∼ 1.6 laterally, compared to the resolution attained using a photomultiplier tube in a non-descanned detection arrangement, and a factor of ∼ 1.8 enhancement in axial resolution. The experimentally measured three-dimensional point spread function volume is shrunk ∼ 4.4 -fold, which is close to the theoretically expected enhancement. Published by the American Physical Society 2024

47 OTHER INSTRUMENTATION↗

Validation of Hole-Drilling Residual Stress Measurements in Workpieces of Various Thickness

A recent revision to the ASTM E837 standard for near-surface residual stress measurement by the hole-drilling method describes a new thickness-dependent stress calculation procedure applicable to “thin” and “intermediate” workpieces for which strain versus depth response depends on workpiece thickness. This new calculation procedure differs from that of the prior standard, which applies only to thick workpieces with strain versus depth response independent of thickness. Herein we assess the new calculation procedures by performing hole-drilling residual stress measurements in samples with a range of thickness. Near-surface residual stress is measured in a thick aluminum plate containing near-surface residual stress from a uniform shot peening treatment, and in samples of different thickness removed from the plate at the peened surface. A finite element (FE) model is used to assess consistency between measured residual stress across the range of sample thickness. Measured residual stress varies with sample thickness, with thinner samples exhibiting smaller near-surface compressive stress and a larger gradient of subsurface stress. These trends are consistent with both observed bending (curvature) of the removed samples and the trend in FE-calculated expected residual stress. The measured and expected residual stresses are in good agreement for samples of intermediate thickness, but the agreement decreases with sample thickness. Measured residual stress is invariant with gage circle diameter. The new thickness-dependent stress calculation procedure for hole-drilling provides meaningful improvement compared to thick-workpiece calculations.

42 ENGINEERING↗

Energy-resolved neutron imaging and diffraction including grain orientation mapping using event camera technology

Time-of-flight neutron diffraction and energy-resolved imaging each provide unique perspectives into material properties. Neutron diffraction is useful for assessing microstructural parameters such as phase composition, texture, and dislocation densities, though it typically provides averaged data over the sampled volume. Energy-resolved imaging, on the other hand, offers both spatial and spectral information by detecting Bragg edges and neutron absorption resonances, which enables detailed mapping of microstructure and isotopic composition. When combined, these techniques have the potential to enrich our understanding of material behavior across different scales, enhancing our understanding of complex materials. Traditionally, these modalities are conducted on separate instruments, which is time-consuming and poses challenges for data integration. Here, we report the integration of the LumaCam, an event-mode energy-resolved neutron imaging camera with the HIPPO time-of-flight diffractometer at LANSCE. This integration enables simultaneous diffraction and imaging across the full spectrum, with analysis optimized for diffraction and Bragg-edge imaging in the thermal range (0.45–10 Å) and resonance imaging in the epithermal range (0.5–3000 eV), facilitating comprehensive multi-modal analysis. We demonstrate its capabilities through case studies, including spatial mapping of grain orientations in a steel sample and accurate thickness estimations for irregular samples including a depleted uranium cylinder and a natural silver-containing mineral specimen. The combined setup enhances real-time sample alignment and provides comprehensive data for crystal structure, texture, and isotopic composition analysis. This approach opens new possibilities for advanced applications in nuclear engineering, archaeology, and materials science.

36 MATERIALS SCIENCE↗

Genesis of compositional characteristics of Stillwater AN-I and AN-II thick anorthosite units

Compositional variations among samples of the thick Stillwater anorthosite units are used here to model the mechanism by which the anorthosite formed. Suspended plagioclase, on reaching a volumetric crystal concentration of about 65 percent, formed a plagioclase framework here called cumulus plagioclase (CP). Within the interstices among the crystals, some plagioclase and pyroxene precipitated, producing what is here called adcumulus plagioclase and pyroxene (APP). The final materials consists mainly of plagioclase and pyroxene formed from complete crystallization of trapped supporting liquid and called intercumulus plagioclase and pyroxene (IPP). Where the CP framework was relatively open initially, bulk liquid communicated with the interior of the framework to produce APP. Where this communication with the bulk liquid stopped or was prevented initially, the intercumulus liquid froze. Where the CP framework was more tightly packed initially, a relatively higher proportion of IPP to APP was produced.

Haskin, Larry A.↗

Estimation of Complex Permittivity of Composite Multilayer Material at Microwave Frequency Using Waveguide Measurements

A simple method is presented to estimate the complex dielectric constants of individual layers of a multilayer composite material. Using the MatLab Optimization Tools simple MatLab scripts are written to search for electric properties of individual layers so as to match the measured and calculated S-parameters. A single layer composite material formed by using materials such as Bakelite, Nomex Felt, Fiber Glass, Woven Composite B and G, Nano Material #0, Cork, Garlock, of different thicknesses are tested using the present approach. Assuming the thicknesses of samples unknown, the present approach is shown to work well in estimating the dielectric constants and the thicknesses. A number of two layer composite materials formed by various combinations of above individual materials are tested using the present approach. However, the present approach could not provide estimate values close to their true values when the thicknesses of individual layers were assumed to be unknown. This is attributed to the difficulty in modelling the presence of airgaps between the layers while doing the measurement of S-parameters. A few examples of three layer composites are also presented.

Deshpande, Manohar D.↗

A hybrid data–model approach to map soil thickness in mountain hillslopes

Abstract. Soil thickness plays a central role in the interactions between vegetation, soils, and topography, where it controls the retention and release of water, carbon, nitrogen, and metals. However, mapping soil thickness, here defined as the mobile regolith layer, at high spatial resolution remains challenging. Here, we develop a hybrid model that combines a process-based model and empirical relationships to estimate the spatial heterogeneity of soil thickness with fine spatial resolution (0.5 m). We apply this model to two aspects of hillslopes (southwest- and northeast-facing, respectively) in the East River watershed in Colorado. Two independent measurement methods – auger and cone penetrometer – are used to sample soil thickness at 78 locations to calibrate the local value of unconstrained parameters within the hybrid model. Sensitivity analysis using the hybrid model reveals that the diffusion coefficient used in hillslope diffusion modeling has the largest sensitivity among all input parameters. In addition, our results from both sampling and modeling show that, in general, the northeast-facing hillslope has a deeper soil layer than the southwest-facing hillslope. By comparing the soil thickness estimated between a machine-learning approach and this hybrid model, the hybrid model provides higher accuracy and requires less sampling data. Modeling results further reveal that the southwest-facing hillslope has a slightly faster surface soil erosion rate and soil production rate than the northeast-facing hillslope, which suggests that the relatively less dense vegetation cover and drier surface soils on the southwest-facing slopes influence soil properties. With seven parameters in total for calibration, this hybrid model can provide a realistic soil thickness map with a relatively small amount of sampling dataset comparing to machine-learning approach. Integrating process-based modeling and statistical analysis not only provides a thorough understanding of the fundamental mechanisms for soil thickness prediction but also integrates the strengths of both statistical approaches and process-based modeling approaches.

58 GEOSCIENCES↗

Eddy-current measurements of thickness of high-temperature coatings

The eddy-current technique was applied to measuring the thickness of a fused silicide coating on a refractory alloy slab. Phase and magnitude of the test signal were measured at four places in 13 different samples, and thickness of coating was computed on the basis of each of these quantities. These results were then compared with those obtained by conventional metallographic methods. Phase-based measurements were most reliable, and the maximum error between the metallographically determined thickness and the thickness as determined by the least squares fit to the phase measurements was less than 0.01 mm (about 1%). Photomicrography of a typical sample shows that a large source of error resides in the fact that two regions - an outer rough region and an inner uniform region - of the coating layer exist rather than the single region upon which the calculations were based.

Dodd, C. V.↗

Swelling of FK800

The report summarizes an assessment of the strain experienced by FK800 upon change in humidity and temperature of its surroundings. The FK800 samples were obtained from Laural Hargrove in the form of a disk that was 12 mm in diameter and 0.5 – 1 mm in thickness. The sample had a Lot # 05172301. For TMA testing, the sample was cut into a small film of dimensions 0.5 mm x 3.38 mm x 6.57 mm and tested under the tensile mode. A single set of swelling experiments were performed on the sample between November and December 2024.

36 MATERIALS SCIENCE↗

Pulsed Laser Deposition of BaCe(sub 0.85)Y(sub 0.15)0(sub 3) FILMS

Pulsed laser deposition has been used to grow nanostructured BaCe(sub 0.85)Y(sub 0.15)0(sub 3) films. The objective is to enhance protonic conduction by reduction of membrane thickness. Sintered samples and laser targets were prepared by sintering BaCe(sub 0.85)Y(sub 0.15)O(sub 3) powders derived by solid state synthesis. Films 2 to 6 m thick were deposited by KrF excimer laser on Si and porous Al2O3 substrates. Nanocrystalline films were fabricated at deposition temperatures of 600-800 C deg at O2 pressure of 30 mTorr and laser fluence of 1.2 J/cm square. Films were characterized by x-ray diffraction, scanning electron microscopy and electrical impedance spectroscopy. Dense single phase BaCe(sub 0.85)Y((sub 0.15) 0(sub 3) films with a columnar growth morphology is observed, preferred crystal growth was found to be dependent upon deposition temperature and substrate type. Electrical conductivity of bulk samples produced by solid state sintering and thin film samples were measured over a temperature range of 100 C deg to 900 C deg in moist argon. Electrical conduction of the fabricated films was 1 to 4 orders of magnitude lower than the sintered bulk samples. With respect to the film growth direction, activation energy for electrical conduction is 3 times higher in the perpendicular direction than the parallel direction.

Dynys, F. W.↗

Freshwater ice thickness observations using passive microwave sensors

Walden Reservoir, a freshwater lake in north-central Colorado, was overflown six times by a NASA C-130 aircraft between January 1977 and April 1980. The aircraft was equipped with four microwave radiometers operating between 0.81 and 6.0 cm in wavelength (37.0 to 5.0 GHz). The 6.0-cm radiometer data showed a good relationship with ice thickness based on a sample of four ice thickness values. The 1.67- and 1.35-cm radiometer data showed weaker relationships with ice thickness. The 0.81-cm sensor data showed no positive relationship with ice thickness. None of the relationships was statistically significant because of the small sample size. The 6.0-cm sensor data in the nadir-viewing mode was found to have the most potential of all the wavelengths studied, for use in remotely determining ice thickness. The 6.0-cm radiometer probably sensed the entire thickness of the ice on the reservoir (ranging from 25.4 to 67.3 cm in thickness) and was apparently not significantly affected by the snow overlying the ice. The shorter wavelengths are scattered by the snow overlying the ice and are more suitable for snow studies than for ice thickness studies.

Hall, D. K.↗

Inversion of Many-Beam Bragg Intensities for Phasing by Iterated Projections: Removal of Multiple Scattering Artifacts from Diffraction Data

An iterated projection algorithm (N-Phaser) is developed that reconstructs a scattering potential from N-beam multiple Bragg scattered intensities. The method may be used to eliminate multiple scattering artifacts from electron diffraction data, solving the phase problem and increasing the thicknesses of samples used in materials science, solid-state chemistry, and small molecule crystallography. For high-energy transmission electron diffraction, we show that the algorithm recovers accurate complex structure factors from a wide range of thicknesses, orientations, and relativistic beam energies, and does not require known thickness or atomic-resolution data if sufficient multiple scattering occurs. Furthermore, extensions to Cryo-electron microscopy and Micro-electron diffraction are suggested.

36 MATERIALS SCIENCE↗