The role of the geothermal gradient in the emplacement and replenishment of ground ice on Mars

Knowledge of the mechanisms by which ground ice is emplaced, removed, and potentially replenished, are critical to understanding the climatic and hydrologic behavior of water on Mars, as well as the morphologic evolution of its surface. Because of the strong temperature dependence of the saturated vapor pressure of H2O, the atmospheric emplacement or replenishment of ground ice is prohibited below the depth at which crustal temperatures begin to monotonically increase due to geothermal heating. In contrast, the emplacement and replenishment of ground ice from reservoirs of H2O residing deep within the crust can occur by at least three different thermally-driven processes, involving all three phases of water. In this regard, Clifford has discussed how the presence of a geothermal gradient as small as 15 K/km can give rise to a corresponding vapor pressure gradient sufficient to drive the vertical transport of 1 km of water from a reservoir of ground water at depth to the base of the cryosphere every 10(exp 6) - 10(exp 7) years. This abstract expands on this earlier treatment by considering the influence of thermal gradients on the transport of H2O at temperatures below the freezing point.

Clifford, Stephen M.↗

Thermomagnetic analysis of meteorites, 2.C2 chondrites

Samples of all eighteen known C2 chondrites have been analyzed thermomagnetically. For eleven of these, initial Fe3O4 content is low (generally less than 1%) and the saturation magnetization-vs.-temperature curves are irreversible. The heating curves show variable and erratic behavior, whereas the cooling curves are similar to that of Fe3O4. The saturation moment after cooling is greater (up to 10 times) than it is initially. This behavior is attributed to the production of magnetite from a thermally unstable phase - apparently FeS. Four of the remaining seven C2 chondrites contain Fe3O4 as the only significant magnetic phase; initial magnetite contents range from 4 to 13%. The remaining three C2 chondrites contain iron or nickel-iron in addition to Fe3O4. These seven C2 chondrites show little evidence of the breakdown of a thermally unstable phase.

Watson, D. E.↗

A Note on the Relationship between Temperature and Water Vapor in Quasi-Equilibrium and Climate States

An ideal and simple formulation is successfully derived that well represents a quasi-linear relationship found between the domain-averaged water vapor, q (mm), and temperature, T (K), fields obtained from a series of quasi-equilibrium (long-term) simulations for the Tropics using the two-dimensional Goddard Cumulus Ensemble (GCE) model. Earlier model work showed that the forced maintenance of two different wind profiles in the Tropics leads to two different equilibrium states. Investigating this finding required investigation of the slope of the moisture-temperature relations, which turns out to be linear in the Tropics. The extra-tropical climate equilibriums become more complex, but insight on modeling sensitivity can be obtained by linear stepwise regression of the integrated temperature and humidity. A globally curvilinear moisture-temperature distribution, similar to the famous Clausius-Clapeyron curve (i.e., saturated water vapor pressure versus temperature), is then found in this study. Such a genuine finding clarifies that the dynamics are crucial to the climate (shown in the earlier work) but the thermodynamics adjust. The range of validity of this result is further examined herein. The GCE-modeled tropical domain-averaged q and T fields form a linearly-regressed "q-T" slope that genuinely resides within an ideal range of slopes obtained from the aforementioned formulation. A quantity (denoted as dC2/dC1) representing the derivative between the static energy densities due to temperature (C2) and water vapor (C1) for various quasi-equilibrium states can also be obtained. A dC2/dC1 value near unity obtained for the GCE-modeled tropical simulations implies that the static energy densities due to moisture and temperature only differ by a pure constant for various equilibrium states. An overall q-T relation also including extra-tropical regions is, however, found to have a curvilinear relationship. Accordingly, warm/moist regions favor change in water vapor faster than temperature, while cold/dry regions favor an increase in temperature quicker than water vapor.

Shie, C.-L.↗

Seasonal Variations in Triton's Atmospheric Mass and Composition

Condensed phases of gases which make up the bulk of Triton's atmosphere are likely to exist on Triton's surface in the form of solid or liquid polar caps which extend as far as 55 deg from the poles. The mass of Triton's atmosphere is governed by the energy balance between the sunlight these caps absorb and the heat they radiate to space. The polar cap temperatures should be approximately equal and uniform over their surfaces. Because of the rapid precession of Triton's orbit about Neptune's pole, the insolation and, therefore, the temperature of the polar caps must vary in a complex fashion. The variations in the temperature of the polar caps will also cause seasonal variations in the mixing ratio of the volatile atmospheric gases owing to the different behaviors of their saturation vapor pressures with temperature. Triton's visible hemisphere is approaching a major southern summer with solstices. If the polar caps are not too thin a dramatic increase in the CH4 column abundance would occur.

Trafton, L. M.↗

Comments on determination of bandgap narrowing from activation plots

A determination is made of the temperature-dependence of emitter saturation current in bipolar devices which allows the derivation of a value for bandgap narrowing that is in better agreement with other determinations than previous results based on ohmic contact measurements of temperature dependence. The new values were obtained by varying the surface recombination velocity at the emitter surface. This improves accuracy by varying the minority carrier surface recombination velocity at the emitter contacts of otherwise indistinguishable emitters.

Park, J.-S.↗

Melting in Martian Snowbanks

Precipitation as snow is an emerging paradigm for understanding water flow on Mars, which gracefully resolves many outstanding uncertainties in climatic and geomorphic interpretation. Snowfall does not require a powerful global greenhouse to effect global precipitation. It has long been assumed that global average temperatures greater than 273K are required to sustain liquid water at the surface via rainfall and runoff. Unfortunately, the best greenhouse models to date predict global mean surface temperatures early in Mars' history that differ little from today's, unless exceptional conditions are invoked. Snowfall however, can occur at temperatures less than 273K; all that is required is saturation of the atmosphere. At global temperatures lower than 273K, H2O would have been injected into the atmosphere by impacts and volcanic eruptions during the Noachian, and by obliquity-driven climate oscillations more recently. Snow cover can accumulate for a considerable period, and be available for melting during local spring and summer, unless sublimation rates are sufficient to remove the entire snowpack. We decided to explore the physics that controls the melting of snow in the high-latitude regions of Mars to understand the frequency and drainage of snowmelt in the high martian latitudes.

Zent, A. P.↗

The silicon vidicon: Integration, storage and slow scan capability - Experimental observation of a secondary mode of operation.

Description of the performance of the silicon diode array vidicon - an imaging sensor which possesses wide spectral response, high quantum efficiency, and linear response. These characteristics, in addition to its inherent ruggedness, simplicity, and long-term stability and operating life make this device potentially of great usefulness for ground-base and spaceborne planetary and stellar imaging applications. However, integration and charged storage for periods greater than approximately five seconds are not possible at room temperature because of diode saturation from dark current buildup. Since dark current can be reduced by cooling, measurements were made in the range from -65 to 25 C. Results are presented on the extension of integration, storage, and slow scan capabilities achievable by cooling. Integration times in excess of 20 minutes were achieved at the lowest temperatures. The measured results are compared with results obtained with other types of sensors and the advantages of the silicon diode array vidicon for imaging applications are discussed.

Ando, K. J.↗

Physiological response of rats to delivery of helium and xenon: implications for hyperpolarized noble gas imaging

The physiological effects of various hyperpolarized helium and xenon MRI-compatible breathing protocols were investigated in 17 Sprague-Dawley rats, by continuous monitoring of blood oxygen saturation, heart rate, EKG, temperature and endotracheal pressure. The protocols included alternating breaths of pure noble gas and oxygen, continuous breaths of pure noble gas, breath-holds of pure noble gas for varying durations, and helium breath-holds preceded by two helium rinses. Alternate-breath protocols up to 128 breaths caused a decrease in oxygen saturation level of less than 5% for either helium or xenon, whereas 16 continuous-breaths caused a 31.5% +/- 2.3% decrease in oxygen saturation for helium and a 30.7% +/- 1. 3% decrease for xenon. Breath-hold protocols up to 25 s did not cause the oxygen saturation to fall below 90% for either of the noble gases. Oxygen saturation values below 90% are considered pathological. At 30 s of breath-hold, the blood oxygen saturation dropped precipitously to 82% +/- 0.6% for helium, and to 76.5% +/- 7. 4% for xenon. Breath-holds longer than 10 s preceded by pre-rinses caused oxygen saturation to drop below 90%. These findings demonstrate the need for standardized noble gas inhalation procedures that have been carefully tested, and for continuous physiological monitoring to ensure the safety of the subject. We find short breath-hold and alternate-breath protocols to be safe procedures for use in hyperpolarized noble gas MRI experiments. Copyright 2000 John Wiley & Sons, Ltd.

NASA Discipline Life Sciences Technologies↗

Nonlinear absorption properties of AlGaAs/GaAs multiple quantum wells grown by metalorganic chemical vapor deposition

The nonlinear absorption properties of the excitonic resonances associated with multiple quantum wells (MQWs) in AlGaAs/GaAs grown by metalorganic chemical vapor deposition are reported. The dependence of the saturation properties on growth parameters, especially growth temperature, and the well width are described. The minimum measured saturation intensity for these materials is 250 W/sq cm, the lowest reported value to date. The low saturation intensities are the result of excellent minority carrier properties. A systematic study of minority carrier lifetimes in quantum wells are reported. Lifetimes range from 50-350 ns depending on growth temperature and well width. When corrected for lateral diffusion effects and the measured minority carrier lifetime, the saturation data suggest that saturation intensities as low as 2.3 W/sq cm can be achieved in this system. The first measurements of the dependence of the exciton area and the magnitude of the excitonic absorption on well width are prsented. The growth of MQW structures on transparent GaP substrates is demonstrated and the electroabsorption properties of these structures are reviewed.

Lee, Hsing-Chung↗

Effects of Polar Stratospheric Clouds in the Nimbus 7 LIMS Version 6 Data Set

The historic Limb Infrared Monitor of the Stratosphere (LIMS) measurements of 1978-1979 from the Nimbus 7 satellite were re-processed with Version 6 (V6) algorithms and archived in 2002. The V6 data set employs updated radiance registration methods, improved spectroscopic line parameters, and a common vertical resolution for all retrieved parameters. Retrieved profiles are spaced about every 1.6 of latitude along orbits and include the additional parameter of geopotential height. Profiles of O3 are sensitive to perturbations from emissions of polar stratospheric clouds (PSCs). This work presents results of implementing a first-order screening for effects of PSCs using simple algorithms based on vertical gradients of the O3 mixing ratio. Their occurrences are compared with the co-located, retrieved temperatures and related to the temperature thresholds needed for saturation of H2O and/or HNO3 vapor onto PSC particles. Observed daily locations where the major PSC screening criteria are satisfied are validated against PSCs observed with the Stratospheric Aerosol Monitor (SAM) II experiment also on Nimbus 7. Remnants of emissions from PSCs are characterized for O3 and HNO3 following the screening. PSCs may also impart a warm bias in the co-located LIMS temperatures, but by no more than 1-2K at the altitudes of where effects of PSCs are a maximum in the ozone; thus, no PSC screening was applied to the V6 temperatures. Minimum temperatures vary between 187 and 194K and often occur 1 to 2 km above where PSC effects are first identified in the ozone (most often between about 21 and 28 hPa). Those temperature-pressure values are consistent with conditions for the existence of nitric acid trihydrate (NAT) mixtures and to a lesser extent of super-cooled ternary solution (STS) droplets. A local, temporary uptake of HNO3 vapor of order 1-3 ppbv is indicated during mid-January for the 550K surface. Seven-month time series of the distributions of LIMS O3 and HNO3 are shown based on their gridded Level 3 data following the PSC screening. Zonal coefficients of both species are essentially free of effects from PSCs on the 550K surface, based on their average values along PV contours and in terms of equivalent latitude. Remnants of PSCs are still present in O3 on the 450K surface during mid- January. It is judged that the LIMS Level 3 data are of good quality for analyzing the larger-scale, stratospheric chemistry and transport processes during the Arctic winter of 1978- 1979.

Remsberg, Ellis↗

Apparatus Makes Precisely Saturated Solutions

Simple laboratory apparatus establishes equilibrium conditions of temperature and concentration in solutions for use in precise measurements of saturation conditions. With equipment typical measurement of saturation concentration of protein in solution established and measured within about 24 hours. Precisely saturated solution made by passing solvent or solution slowly along column packed with solute at precisely controlled temperature. If necessary, flow stopped for experimentally determined interval to allow equilibrium to be established in column.

Pusey, Marc L.↗

Anorthite - Thermal equation of state to high pressures

New shock-wave data are presented for anorthite from which a full high-temperature, high-pressure equation of state is derived. Whereas anorthite has relatively low values of thermal expansion and Grueneisen parameter at zero pressure, it is found that these attain relatively high values in the high density state corresponding to the high-pressure phase Hugoniot but decrease upon compression as expected. It is noted that higher order anharmonic contributions decrease more rapidly with pressure and that the thermal expansion therefore saturates to a high temperature value at pressures above about 100 GPa. Reduction of the Hugoniot data permits shock temperatures to be calculated; it also yields a principal adiabat for the high pressure branch of the Hugoniot. The initial bulk modulus of this adiabat is essentially identical to that of anorthite, whereas the initial density is about 3.40 Mg/cu m.

Jeanloz, R.↗

Change of Exposure Time Mid-test in High Temperature DIC Measurement

Performing digital image correlation (DIC) at extreme temperatures has been greatly challenging due to the radiation which saturates the camera sensor. At such high temperatures, the light intensity emitted from an object is occasionally so powerful that the acquired images are overwhelmingly saturated. This induces data loss, potentially ruining the test, thus requiring the user to restart the test. For this reason, selection of an appropriate camera sensitivity plays a crucial role prior to beginning the test. Exposure time is a factor contributing to camera sensitivity and it is the easiest setting to manipulate during the test since it introduces minimal errors when comparing to other factors, especially in quasi-static tests. This paper examines the influence of changing exposure time mid-test on DIC measurement uncertainty. The investigation was conducted by rigid body motion experiments at room temperature and 1600 ◦C, respectively. Thereby, some recommendations are given to help DIC users assess their images at room temperature to extrapolate the exposure at extreme temperatures along with accompanying solutions to salvage data at high temperature.

Digital Image Correlation↗

Insulation-Testing Cryostat With Lifting Mechanism

The figure depicts selected aspects of an apparatus for testing thermal-insulation materials for cryogenic systems at temperatures and under vacuum or atmospheric conditions representative of those encountered in use. This apparatus, called "Cryostat-100," is based on the established cryogen-boil-off calorimeter method, according to which the amount of heat that passes through an insulation specimen to a cryogenic fluid in a container, and thus the effective thermal conductance of the specimen, is taken to be proportional to the amount of the cryogenic fluid that boils off from the container. The design of Cryostat-100 is based partly on, and incorporates improvements over, the design of a similar prior apparatus called "Cryostat-1" described in "Improved Methods of Testing Cryogenic Insulation Materials" (KSC-12107 & KSC- 12108), NASA Tech Briefs, Vol. 24, No. 12 (December 2000), page 46. The design of Cryostat-100 also incorporates the best features of two other similar prior apparatuses called "Cryostat-2" (also described in the cited prior article) and "Cryostat- 4." Notable among the improvements in Cryostat-100 is the addition of a lifting mechanism that enables safe, rapid, reliable insertion and removal of insulation specimens and facilitates maintenance operations that involve lifting. As in Cryostat-1, the cold mass is a vertical stainless-steel cylindrical vessel subdivided into a larger measurement vessel with smaller thermal-guard vessels at both ends. During operation, all three vessels are kept filled with liquid nitrogen near saturation at ambient pressure (temperature .77.4 K). The cold mass of Cryostat-100 has a length of 1 m and diameter of 168 mm. Each specimen has a corresponding nominal length and inner diameter and a nominal thickness of 25.4 mm. Specimens that are shorter and have thicknesses between 0 and 50 mm are also acceptable. Bulk-fill, foam, clam-shell, multilayer insulation, and layered materials can be tested over a very wide range of thermal transmission: apparent thermal conductivity from 0.01 to 60 mW/m-K and heat flux from 0.1 to 500 W/sq m. A test in Cryostat-100 can be conducted at any desired gas pressure between ambient atmospheric pressure at one extreme and a vacuum with residual pressure <10(exp -5) torr (<1.33 10(exp -3) Pa) at the other extreme. The residual gas (and purge gas) is typically nitrogen, but can be any suitable purge gas (e.g., helium, argon, or carbon dioxide). Usually, the temperature on the warm boundary of the insulation specimen is maintained near the ambient value (approximately 293 K), while the boiling of liquid nitrogen at atmospheric pressure in the cold mass maintains the temperature on the cold boundary of the specimen at approximately 77 K.

Fesmire, James↗

Hybrid simulations of the saturated Farley-Buneman instability in the ionosphere

Numerical simulations of the Farley-Buneman instability in 2-1/2 dimensions using particle ions and fluid electrons show the growth, saturation and nonlinear behavior of two-stream waves. This hybrid technique models the saturated state of the instability for a much longer period of time than the pure particle codes that preceded it. While focusing principally on modeling the topside E region equatorial electrojet, many of these results apply to the auroral two-stream instability as well. The following features are seen in all our hybrid simulations: (1) wave growth at an angle offset from the electron drift direction where the angle depends on the strength of the driving electric field, (2) nonlinear coupling to waves traveling perpendicular to the propagation direction of the principal two-stream waves, (3) a saturated wave phase velocity at or above the sound speed but well below the velocity predicted by linear theory and (4) phase velocities which remain almost constant as a simulated radar sweeps from a horizontal direction to nearly vertical. The nonlinear electron motion dominates the behavior of these waves. Further, these simulations indicate that ion kinetic effects are not essential for the saturation of the instability and that electron temperature effects have a minor impact on the final saturated state.

Oppenheim, Meers↗

Preliminary study of the minimum temperatures for valid testing in a cryogenic wind tunnel

The minimum operating temperature which avoids real-gas effects, such as condensation, was determined for M sub infinity = 0.85 flow over a 0.137-meter NACA 0012-64 airfoil mounted in the Langley 1/3-meter transonic cryogenic tunnel. For temperatures within 5 K of reservoir saturation and total pressures from 1.2 to 4.5 atmospheres, the pressure distributions over the airfoil are not altered by real-gas effects. This ability to test at total temperatures below those which avoid saturation over the airfoil allows an increase in Reynolds number capability of at least 17 percent for a constant tunnel total pressure. Similarly, 17 percent less total pressure is required to obtain a given Reynolds number.

Hall, R. M.↗

Phase change in liquid face seals

A study is made of boiling (or phase change) in liquid face seals. An appropriate model is set up and approximate solutions obtained. Some practical illustrative examples are given. Major conclusions are that (1) boiling may occur more often than has been suspected particularly when the sealed liquid is near saturation conditions, (2) the temperature variation in a seal clearance region may not be very great and the main reason for boiling is the flashing which occurs as the pressure decreases through the seal clearance, and (3) there are two separate values of the parameter film-thickness/angular-velocity-squared (and associated radii where phase change takes place) which provide the same separating force under a given set of operating conditions. For a given speed seal face excursions about the larger spacing are stable, but excursions about the smaller spacing are unstable, leading to a growth to the larger spacing or a catastrophic collapse.

Hughes, W. F.↗

Vapor-liquid phase separator studies

Porous plugs serve as both entropy rejection devices and phase separation components separating the vapor phase on the downstream side from liquid Helium 2 upstream. The liquid upstream is the cryo-reservoir fluid needed for equipment cooling by means of Helium 2, i.e Helium-4 below its lambda temperature in near-saturated states. The topics outlined are characteristic lengths, transport equations and plug results.