Search NASA⌕ Search

SEARCH · Search NASA

Results for “scintillator characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Onset of Fogging and Degradation in Polyvinyl Toluene-Based Scintillators

Plastic-based gamma-ray detector materials such as polyvinyl toluene (PVT) occasionally suffer from loss of optical light transmission due to internal defects or “fogging” when exposed to some environmental conditions over time. Fogging results in reduced scintillation light propagated to the photomultiplier tube for collection. Investigations of the physical cause of these defects and their associated environmental conditions are ongoing. The goal of this work was to characterize the signs and effects of fogging over a simulated 22-year lifespan of the PVT in outdoor environments. Here, two potential mitigation methods were also evaluated, and one successfully mitigated the phenomena.

36 MATERIALS SCIENCE↗

Standard Analytical Methods for Pyrolysis Bio-Oils

There has been significant recent interest in the production of renewable fuels and chemicals from biomass and waste feedstocks. Pyrolysis pathways produce a liquid bio-oil product, which must be processed further, or upgraded, to yield fuel or chemical products. Bio-oils are very complex and often unstable samples, and research and development on upgrading processes needs reliable analytical information. In particular, chemical characterization techniques are needed to quantify both functional groups and individual compounds present in bio-oils. Reliable analytics are also needed to enable the bioenergy industry, as industrial facilities often have different analytical needs and capabilities than research facilities. In this presentation, we will discuss the development of a suite of standard analytical methods for pyrolysis bio-oils. Analytical methods to be discussed include: Determination of Carbon, Hydrogen, Nitrogen, and Oxygen in bio-oils; Accelerated Aging of Fast Pyrolysis Bio-oil using Carbonyl Titration; Determination of Water Content in Bio-oils by Volumetric Karl Fischer Titration; Determination of Carbon Functional Groups; Elemental Analysis of Bio-oils by Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES) - Na, K, Mg, Ca, S, P, and Fe; Determination of Phenolic Groups in Bio-oils using Revised Folin-Ciocalteu Methods: Single Cuvette and Plate Reader; Corrosivity of Bio-oils: Screening Test using Metal Leaching; Determination of Biogenic Content by 14C Measurement using Liquid Scintillation Counter. These new analytical methods are publicly available as Laboratory Analytical Procedures (https://www.nrel.gov/bioenergy/bio-oil-analysis.html), along with previously developed standard methods: GC-MS, Acid Titration, Carbonyl Titration, and 31P NMR. Additionally, the development of diffusion ordered NMR for characterization of bio-oil molecular weight will be discussed. Collectively, this suite of analytical methods represents the most comprehensive set of standard methods available for pyrolysis bio-oils. These standard methods are commonly used by the bioenergy community, and provide reliable information that enables research, scaleup, and industrial processing of biomass to produce renewable fuels and chemicals.

analytical↗

Performance and Stability Characterization of the ICARUS Light Detection System

The ICARUS detector, a key component of the Short Baseline Neutrino (SBN) Program at Fermilab, consists of two identical T300 modules filled with liquid argon. It is equipped with a Light Detection System (LDS) based on 360 8-inch Hamamatsu R5912-MOD photomultiplier tubes (PMTs) arranged behind the wire planes to collect Vacuum Ultraviolet (VUV, $\sim$ 128 nm) scintillation light. Operating under cryogenic conditions ( $\sim$ 87 K), the LDS is essential for determining the event start time (t0) with nanosecond precision for beam spill synchronization, improving longitudinal spatial resolution, and contributing to the event trigger and cosmic-ray mitigation. The performance of the LDS was investigated addressing both hardware and data analysis aspects. Following a progressive degradation in PMT gain observed during operations at FNAL, systematic gain measurements were first carried out from room temperature down to low temperatures. The results show stable performance at room temperature but a significant, irreversible reduction in gain at low temperatures. Based on these findings, a series of mitigation strategies were implemented in the ICARUS detector to preserve PMT performance and ensure reliable cryogenic operation. Currently, ongoing waveform analysis of the PMT signals is being performed to characterize signal shape, charge integration, and timing properties, aiming to refine and improve the agreement between experimental data and Monte Carlo simulations.

Saia, Clara [U. Catania (main); INAF, Catania; Cat↗

Commissioning a time-gated camera for fast neutron beamline spatial-energy characterization at LANSCE-WNR spallation source

An energy-resolved fast neutron beam imaging diagnostic has been successfully commissioned at the Weapons Neutron Research (WNR) spallation source within the Los Alamos Neutron Science Center (LANSCE) facility. This diagnostic replaces the existing analog phosphor image plates, which integrate across all neutron energies, as well as other particles, with a near-real-time energy-sensitive imaging capability. The system uses a fast plastic scintillator coupled with an intensified CCD camera. Specifically, the Teledyne Pi-MAX4 camera is coupled with either a 4 mm thick Eljen (EJ) 204 or 228 plastic scintillator. These scintillators are most sensitive to the fast neutrons (0.8-800 MeV) directly from the spallation source rather than low energy background radiation. Experimentally, these plastic scintillators were shown to have sufficiently fast decay to differentiate the bright gamma flash from the spallation neutrons. The spatial resolution is dominated by neutron beam divergence, with minimal additional contributions from scatter and light divergence. The system successfully resolved changes in neutron beam characteristics caused by intentional proton steering variations. Additionally, simulations of scintillator light yield as a function of thickness conducted using PHITS (with Scinful-QMD package) found that increasing scintillator thickness from 4 mm to 6 or 8 mm could potentially increase brightness ~ 3x. This may be explored if there is a need to reduce image acquisition time from several minutes to under one minute.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of measurement techniques and sorption of radium-226 in low and high salinity aqueous samples

Human activities have the potential to redistribute radium (Ra) in the marine environment in a manner that may necessitate monitoring or management of subsequent human or environmental exposures. There is therefore a need to identify accurate and accessible techniques for Ra measurement in high salinity samples and to describe the distribution of Ra in estuarine and marine environments, but most efforts in these areas have focused on low salinity matrices. In addition, rapid and reliable measurements are crucial for time-sensitive samples such as short-lived isotopes or emergency situations. The objective of this study is to describe the limits of detection, cost, and relative ease for measurement of Ra in both low and high salinity aqueous samples via three analytical methods: liquid scintillation counting (LSC), high purity germanium (HPGe) gamma spectrometry, and inductively coupled plasma mass spectrometry (ICP-MS). To contextualize these measurements for real-world scenarios, the partitioning of 226 Ra to substrates relevant to the marine environment was also characterized. Although HPGe detection with solid phase extraction had the lowest limit of detection for low salinity samples (0.27 Bq L −1 ), poor 226 Ra recovery for high salinity samples and high materials costs make this method prohibitive for many users. Limits of detection for high salinity samples were lower for LSC (1.28 Bq L −1 ) than for ICP-MS without dilution (11.4 Bq L −1 ), but significant and unexpected degradation of the high salinity LSC standards was observed after six months. Furthermore, our preferred measurement method for high salinity Ra samples is ICP-MS with sample dilution as necessary to reduce matrix effects.

07 ISOTOPE AND RADIATION SOURCES↗

Studies on the scintillation light detection in the ProtoDUNE Dual Phase liquid-argon TPC and its capability for the supernova trigger in DUNE

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino oscillation experiment that aims at addressing key questions in neutrino physics in the next decades. Its scientific program includes the detection of the neutrino flux from a core-collapse supernova. The DUNE far detector will have four 17-kt mass liquid-argon (LAr) time-projection chamber (TPC) modules. ProtoDUNE Dual Phase (DP), a dual-phase LAr TPC with 300 t of active mass and 6 m of drift distance, was operated with cosmic muons in 2019-2020 as part of an R&D program at the CERN Neutrino Platform to demonstrate the feasibility of the technology at such a large scale. In a LAr TPC, the photon detection system (PDS) provides fun- damental timing information and trigger capabilities. The PDS of ProtoDUNE-DP, which consisted of 36 photomultiplier tubes (PMTs), counted on a dedicated light calibration system (LCS) to monitor the PMT response. In this dissertation, the characterization and validation of the ProtoDUNE-DP PDS and LCS components before their installation will be reviewed, highlighting the results of general interest for experiments that use liquid noble gasses as target medium. The results from the stable performance of both systems in the detector during 15 months will be presented next as well as the studies on the scintillation light detection in ProtoDUNE-DP, where the collection of light produced in LAr at 7 m from the photosensors has been achieved for the first time. It is worth pointing out that the excellent LAr purity and the large size of the detector have enabled to develop a unique data-driven investigation on aspects that are critical for LAr- based experiments but that are not completely understood. The analyses cover the characterization of the low-energy background detected by the PDS, the quantification of the electric field impact on the light yield, the evaluation of the Rayleigh scattering affecting the light propagation, and the analysis of the PMT detection efficiency. The effect of the VUV reflectivity of the detector materials will be also discussed. In addition, the estimation of the cosmic muon flux crossing the TPC and the study of the observed light yield by the PDS will be reported. Finally, the results from the simulation-based study of the supernova burst trigger capability with the PDS of a 12.1-kt active mass dual-phase LAr TPC as the one proposed for DUNE will be summarized. Several configurations of reflective foils installed in the TPC to enhance the light collection will be compared

Gallego-Ros, Ana↗

Studies on the scintillation light detection in the ProtoDUNE Dual Phase liquid-argon TPC and its capability for the supernova trigger in DUNE

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino oscillation experiment that aims at addressing key questions in neutrino physics in the next decades. Its scientific program includes the detection of the neutrino flux from a core-collapse supernova. The DUNE far detector will have four 17-kt mass liquid-argon (LAr) time-projection chamber (TPC) modules. ProtoDUNE Dual Phase (DP), a dual-phase LAr TPC with 300 t of active mass and 6 m of drift distance, was operated with cosmic muons in 2019-2020 as part of an R&D program at the CERN Neutrino Platform to demonstrate the feasibility of the technology at such a large scale. In a LAr TPC, the photon detection system (PDS) provides fundamental timing information and trigger capabilities. The PDS of ProtoDUNE-DP, which consisted of 36 photomultiplier tubes (PMTs), counted on a dedicated light calibration system (LCS) to monitor the PMT response. In this dissertation, the characterization and validation of the ProtoDUNE-DP PDS and LCS components before their installation will be reviewed, highlighting the results of general interest for experiments that use liquid noble gasses as target medium. The results from the stable performance of both systems in the detector during 15 months will be presented next as well as the studies on the scintillation light detection in ProtoDUNE-DP, where the collection of light produced in LAr at 7 m from the photosensors has been achieved for the first time. It is worth pointing out that the excellent LAr purity and the large size of the detector have enabled to develop a unique data-driven investigation on aspects that are critical for LAr-based experiments but that are not completely understood. The analyses cover the characterization of the low-energy background detected by the PDS, the quantification of the electric field impact on the light yield, the evaluation of the Rayleigh scattering affecting the light propagation, and the analysis of the PMT detection efficiency. The effect of the VUV reflectivity of the detector materials will be also discussed. In addition, the estimation of the cosmic muon flux crossing the TPC and the study of the observed light yield by the PDS will be reported. Finally, the results from the simulation-based study of the supernova burst trigger capability with the PDS of a 12.1-kt active mass dual-phase LAr TPC as the one proposed for DUNE will be summarized. Several configurations of reflective foils installed in the TPC to enhance the light collection will be compared.

Gallego Ros, Ana↗

Proton damage in (Y,Lu,Gd) 3 (Al,Ga) 5 O 12 :Ce mixed garnet scintillators

Scintillators are vital components for nuclear instrumentation and its applications, including plasma diagnostics and imaging. As yields in controlled fusion experiments increase, the radiation tolerance of scintillator candidates for use in instrumentation is of particular importance. High radiation exposure can damage scintillating materials and alter the optical properties. The effects of radiation damage in Ce-doped mixed garnet ceramics over the compositional range (Y,Gd,Lu) 3 (Al,Ga) 5 O 12 are investigated using optical techniques. The samples were exposed to 200 keV protons to an accumulated fluence of 10 16 protons per square centimeter, then characterized using diffuse reflectance spectroscopy (DRS). DRS with visible light can assess the radiation tolerance of opaque poly-crystalline samples, which can be easily sintered from powders and thus offer distinct advantages in characterization compared to single crystals. Qualitative trends in induced absorption are presented as a function of composition, and the ideal cerium dopant concentration for Y 2 LuAl 5 O 12 is determined to be 0.60–0.75 mol.%.

47 OTHER INSTRUMENTATION↗

An all-digital associated particle imaging system for the 3D determination of isotopic distributions

Associated particle imaging (API) is a non-destructive nuclear technique for the 3D determination of isotopic distributions. By detecting the alpha particle associated with the emitted neutron in the deuterium–tritium fusion reaction with a position- and time-resolving detector, the direction of the 14.1 MeV neutron and its time of emission can be determined. Employing this method, isotope characteristic gamma rays emitted in inelastic neutron scattering events can be correlated with the neutron interaction location. Here, an API system consisting of a sealed-type neutron generator, gamma detectors, and a position-sensitive alpha detector was designed, constructed, and characterized. The system was tested with common soil elements and shown to be sensitive to 12 C, 16 O, 28 Si, 27 Al, and 56 Fe. New aspects of our approach are the use of a yttrium–aluminum–perovskite scintillator, using a sapphire window instead of a fiber-optic faceplate for light transport to the photomultiplier, and the all-digital data acquisition system. We present a description of the system with simulations and experimental results that show a position resolution on the alpha detector of 1 mm, a depth resolution using a LaBr 3 detector of 6.2 cm, and an angular resolution of 4.5°. Additionally, we present single-element gamma response measurements for the elements mentioned above together with a comparison to Monte Carlo simulations (MCNP6).

47 OTHER INSTRUMENTATION↗

Development of a pixelated BaF 2 test bed for timing applications [Slides]

BaF 2 one of the fastest known scintillators, emitting at 195 & 220 nm with sub-nanosecond decay constant. Fast emission only comprises ~13% of total light. The goal is to develop a prototype BaF 2 detector system with a practical form factor and variable geometry, and characterize system performance for various timing applications.

42 ENGINEERING↗

Detection of scintillation light in noble gases with wavelength-shifting optical fibers

Wavelength-shifting (WLS) techniques enable particle detectors based on noble gases, whose scintillation light is predominantly emitted in the vacuum-ultraviolet. We investigate WLS fibers coated with tetraphenyl butadiene (TPB) for scintillation light detection in gaseous xenon and argon at pressures up to 8.5 bar, motivated by future high-pressure xenon time-projection chambers of the NEXT program. Two detector configurations are studied: an elongated high-pressure vessel with four PTFE panels equipped with WLS fibers read by temperature-stabilized SiPMs, and a compact box-shaped detector operated at 1 bar Xe with WLS fibers read out by PMTs. Both operate with continuous gas purification. The detector response is characterized using cosmic muons and alpha particles from a $^{241}$Am source. With the SiPM setup, we measure a light collection efficiency (LCE) of ${1.18 \pm 0.01~\mathrm{(sta.)}~^{+0.07}_{-0.09}~\mathrm{(sys.)}~\%}$ for xenon and ${1.07 \pm 0.01~\mathrm{(sta.)}~^{+0.06}_{-0.08}~\mathrm{(sys.)}~\%}$ for argon. With PMT readout, we measure a LCE of ${0.45 \pm 0.01~\mathrm{(sta.)} \pm 0.05~\mathrm{(sys.)}~\%}$ in xenon, in agreement with the SiPM result once photon detection efficiency is accounted for. Average scintillation waveforms in xenon and argon are studied to assess the time structure of the emitted light. Cosmic-muon measurements yield a mean energy required to produce a scintillation photon $45\pm7~\mathrm{(sta.)}~^{+4}_{-5}~\mathrm{(sys.)}~\mathrm{eV}$ at 1.5 bar, in agreement with the literature. The results demonstrate that TPB-coated WLS fiber systems can reliably detect scintillation light in high-pressure gaseous noble detectors, with a LCE representing an upper limit for realistic large-scale TPCs, where additional photon losses from materials and fiber attenuation are expected.

Soleti, S. R. [Donostia Intl. Phys. Ctr., San Seba↗

Quantification of the light output anistropy in deuterated stilbene

Deuterated stilbene is an organic scintillator that is a desirable material for fast neutron spectroscopy using spectrum unfolding techniques without requiring time-of-flight information. Due to the crystal structure of the material, some anisotropy of the light output exists, which is dependent on the direction of heavy charged particle recoil relative to the crystal structure. The anisotropy of trans-stilbene (hereafter referred to as stilbene) has been well characterized in previous work, but for deuterated stilbene, the anisotropy has only been partially characterized along the a and b crystal axes, while the artificial c' axis, which shows the largest anisotropy in stilbene, has not been characterized until this publication. Here, in this work, two deuterated stilbene crystals were characterized with neutron energies up to 35 MeV at the Los Alamos Neutron Science Center. For one of the crystals, the response is characterized along the a, b, and c' axes. This characterization shows a distinct anisotropy along the axes in deuterated stilbene, which is very similar to that found in regular stilbene, such that the a axis is the brightest, while the b' and c' axes are approximately 3% and 20%–35% lower relative to the a axis.

36 MATERIALS SCIENCE↗

Upgrade of the CAESium-iodide scintillator ARray (CAESAR) electronics and data acquisition system for optimized performance at FRIB

Here, we report on the upgrade of the electronics and data acquisition (DAQ) of the high-efficiency CAESium-iodide scintillator ARray (CAESAR) at the Facility for Rare Isotope Beams (FRIB). With the on-going capability ramp-up of FRIB, CAESAR is expected to continue to be an in-demand -ray spectrometer owing to its high detection efficiency, compactness, and modularity, enabling easy integration with additional detection and DAQ systems. Within this context, the CAESAR electronics and DAQ were upgraded to remove obsolete modules, enhance the ease of integration with external instruments, and optimize the DAQ live time. We present the comprehensive results from offline (γ-ray sources) and online (in-beam experiment) commissioning, characterizing the performance of CAESAR’s new electronics and DAQ.

CsI(Na) scintillator array↗

ANNIE: Neutron multiplicity in neutrino interactions and new technologies

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) aims at measuring the neutron abundance in the final state of neutrino-nucleus interactions. This measurement will have a direct impact on our understanding of neutrino interactions and will lead to a better reduction of systematic errors and an improvement of signal-background discrimination in future large neutrino detectors, thus impacting long baseline oscillation experiments as well as proton decay searches and supernova detection. With a volume of about 26 tons of pure water doped with gadolinium to enhance neutron tagging efficiency, ANNIE will provide a measurement of the neutron yield of neutrino interactions as a function of the neutrino energy in the well-characterized Booster Neutrino Beam at Fermilab. The modularity of ANNIE will allow it to perform several fundamental tests of new technologies to be used in neutrino detectors, such as a novel kind of photodetectors called Large Area Picosecond Photodetectors and Water-based Liquid Scintillator, a newly-developed detection medium. The technology behind the ANNIE detector will have a noticeable impact on the development of future large water Cherenkov detectors as well as on detection techniques for neutrino physics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of dynamics and decay in the St. Benedict Paul trap

The St. Benedict experiment includes a linear Paul trap designed to measure the beta-neutrino angular correlation coefficient 𝑎 𝛽ν of mixed superallowed 𝛽-decay transitions between mirror nuclei via coincidence detection of 𝛽-particles and recoiling ions. The emitted 𝛽 particle and daughter ion are detected with plastic scintillators and micro-channel plate detectors, respectively, allowing for accurate measurements of their time-of-flights. From the shape of the coincidence time-of-flight distribution, a value of 𝑎 𝛽ν can be determined. This manuscript presents detailed simulations of the St. Benedict Paul trap, with a focus on ion cloud dynamics and recoiling daughter trajectories.

Linear Paul trap↗

Design and Characterization of an Optically Segmented Single Volume Scatter Camera Module

Here, the optically segmented single volume scatter camera (OS-SVSC) aims to image neutron sources for nuclear nonproliferation applications using the kinematic reconstruction of elastic double-scatter events. We report on the design, construction, and calibration of one module of a new prototype. The module includes 16 EJ-204 organic plastic scintillating bars individually wrapped in Teflon tape, each measuring 0.5cx0.5cmx20cm . The scintillator array is coupled to two custom silicon photomultiplier (SiPM) boards consisting of a 2x8 array of SensL J-Series-60035 SiPMs, which are read out by a custom 16 channel DRS4 based digitizer board. The electrical crosstalk between SiPMs within the electronics chain is measured as 0.76%±0.11% among all 16 channels. We report the detector response of one module including interaction position, time, and energy, using two different optical coupling materials: EJ-560 silicone rubber optical coupling pads and EJ-550 optical coupling grease. We present results in terms of the overall mean and standard deviation of the z -position reconstruction and interaction time resolutions for all 16 bars in the module. We observed the 1σz -position resolution for gamma interactions in the 0.3–0.4 MeVee range to be 2.24 cm ± 1.10 cm and 1.45 cm ± 0.19 cm for silicone optical coupling pad and optical grease, respectively. The observed 1σ interaction time resolution is 265 ps ± 29 ps and 235 ps ± 10 ps for silicone optical coupling pad and optical grease, respectively.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

UCNProBe NaI Veto System Characterization and Simulation

This paper presents a summary of my research and technical contributions during a summer internship at Los Alamos National Laboratory, supporting the development of the active veto system for the UCNProBe experiment. UCNProBe aims to perform a state-of-the-art measurement of the free neutron lifetime, requiring low-background conditions facilitated by an array of sodium iodide (NaI) scintillators.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

3D printed water-stable Cd-doped Cs 4 MnBi 2 Cl 12 /polylactic acid perovskite/polymer composites for high-flux X-ray scintillation

Stable and efficient X-ray scintillators are crucial for medical diagnostics, industrial, and defense applications. However, conventional scintillator technologies face a trade-off between stability, optimal performance, and sustainability. Herein, we introduce 3D-printed Cs 4 MnBi 2 Cl 12 (Pero1) and Cs 4 Cd 0.68 Mn 0.32 Bi 2 Cl 12 (Pero2) perovskite microcrystals embedded within a polylactic acid (PLA) polymer composite as X-ray scintillators, combining efficiency, stability, and sustainability. The orange luminescent perovskite powder phosphors exhibited poor water stability, which was successfully addressed through incorporation into PLA via filament extrusion and fused deposition modeling (FDM) 3D printing. The resulting composite films demonstrated remarkable water stability while maintaining uniform orange emission throughout the polymer matrix, as confirmed by 3D topography scanning and X-ray fluorescence mapping. Structural characterization revealed minimal chemical interaction between the perovskite and PLA matrix, with the composites retaining their crystalline properties. The PLA-Pero2 composite exhibited superior optical properties, with a photoluminescence quantum yield of 47%, nearly 17 times higher than that of PLA-Pero1 (2.8%), attributed to the effective suppression of non-radiative decay pathways through Cd 2+ doping. Under hard X-ray irradiation at synchrotron beamlines, both composites exhibited excellent radioluminescence, with emission peaks at 605 nm, a linear response across a wide X-ray flux range, and remarkable radiation stability, showing less than 3% intensity degradation after 600 seconds of continuous high-dose exposure. The PLA-Pero2 composite achieved a spatial resolution of 5 line pairs per millimeter and a contrast ratio of 0.255. These performance metrics, combined with the polymer's biodegradability and scalability through additive manufacturing, position PLA-based composites as a more sustainable alternative to conventional petroleum-based polymer scintillators for next-generation medical imaging, radiation monitoring, and industrial radiography applications.

3D Printing↗