Search NASA⌕ Search

SEARCH · Search NASA

Results for “screening interval”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Factors associated with serum thyroglobulin in a Ukrainian cohort exposed to iodine-131 from the accident at the Chernobyl Nuclear Plant

Background: Serum thyroglobulin (Tg) is associated with the presence of thyroid disease and has been proposed as a biomarker of iodine status. Few studies have examined factors related to serum Tg in populations environmentally exposed to ionizing radiation and living in regions with endemic mild-to-moderate iodine deficiency. Methods: We screened 10,430 individuals who were living in Ukraine and under 18 years of age at the time of the 1986 Chernobyl Nuclear Power Plant accident for thyroid disease from 2001 to 2003. We estimated the percent change (PC) in serum Tg associated with demographic factors, iodine-131 thyroid dose, and indicators of thyroid structure and function using linear regression. We also examined these relationships for individuals with and without indications of thyroid abnormality. Results: Mean and median serum Tg levels were higher among participants with abnormal thyroid structure/function. Percent change in serum Tg increased among females, smokers and with older age (p-values<0.001), and Tg increased with increasing thyroid volume, and serum thyrotropin (p-values for trend<0.001). We found no evidence of significant associations between iodine-131 thyroid dose and Tg. Serum Tg levels were inversely associated with iodized salt intake (PC=−7.90, 95% confidence interval: −12.08, −3.52), and over the range of urinary iodine concentration, the odds of having elevated serum Tg showed a U-shaped curve with elevated Tg at low and high urinary iodine concentrations. Conclusion: Serum Tg may be a useful indicator of population iodine status and a non-specific biomarker of structural and functional thyroid abnormalities in epidemiological studies. - Highlights: • We evaluated serum thyroglobulin (Tg) in 10,430 irradiated, mostly iodine deficient Ukrainians. • Tg levels were higher among subjects with abnormal thyroid structure/function. • Increased Tg was associated with increasing age, thyroid volume and thyrotropin levels. • The odds of elevated Tg showed a U-shaped curve over categories of dietary iodine status. • Serum Tg is a useful indicator of population iodine status and thyroid abnormalities.

54 ENVIRONMENTAL SCIENCES↗

Hyperthermia and Radiation Therapy in Locoregional Recurrent Breast Cancers: A Systematic Review and Meta-analysis

Purpose: To conduct a systematic review and meta-analysis to evaluate the outcome of hyperthermia (HT) and radiation therapy (RT) in locally recurrent breast cancers (LRBCs). Methods and Materials: A total of 708 abstracts were screened from 8 databases according to the PRISMA guidelines. Single-arm and 2-arm studies, treating LRBCs with HT and RT but without surgery (for local recurrence) or concurrent chemotherapy were considered. The evaluated endpoint was complete response (CR). Results: Thirty-one full text articles, pertaining to 34 studies, were shortlisted for the meta-analysis. Eight were 2-arm (randomized, n=5; nonrandomized, n=3), whereas 26 were single-arm studies. In all, 627 patients were enrolled in 2-arm and 1483 in single-arm studies. Patients were treated with a median of 7 HT sessions, and an average temperature of 42.5°C was attained. Mean RT dose was 38.2 Gy (range, 26-60 Gy). Hyperthermia was most frequently applied after RT. In the 2-arm studies, a CR of 60.2% was achieved with RT + HT versus 38.1% with RT alone (odds ratio 2.64, 95% confidence interval [CI] 1.66-4.18, P<.0001). Risk ratio and risk difference were 1.57 (95% CI 1.25-1.96, P<.0001) and 0.22 (95% CI 0.11-0.33, P<.0001), respectively. In 26 single-arm studies, RT + HT attained a CR of 63.4% (event rate 0.62, 95% CI 0.57-0.66). Moreover, 779 patients had been previously irradiated (696 from single-arm and 83 from 2-arm studies). A CR of 66.6% (event rate 0.64, 95% CI 0.58-0.70) was achieved with HT and reirradiation (mean ± SD dose: 36.7 ± 7.7 Gy). Mean acute and late grade 3/4 toxicities with RT + HT were 14.4% and 5.2%, respectively. Conclusions: Thermoradiation therapy enhances the likelihood of CR rates in LRBCs over RT alone by 22% with minimal acute and late morbidities. For even those previously irradiated, reirradiation with HT provides locoregional control in two-thirds of the patients. Thermoradiation therapy could therefore be considered as an effective and safe palliative treatment option for LRBCs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Risk Factors and Trends for HPV-Associated Subsequent Malignant Neoplasms among Adolescent and Young Adult Cancer Survivors

Subsequent malignant neoplasms (SMN; new cancers that arise after an original diagnosis) contribute to premature mortality among adolescent and young adult (AYA) cancer survivors. Because of the high population prevalence of human papillomavirus (HPV) infection, we identify demographic and clinical risk factors for HPV-associated SMNs (HPV-SMN) among AYA cancer survivors in the SEER-9 registries diagnosed from 1976 to 2015. Outcomes included any HPV-SMN, oropharyngeal-SMN, and cervical-SMN. Follow-up started 2 months after their original diagnosis. Standardized incidence ratios (SIR) compared risk between AYA survivors and general population. Age-period-cohort (APC) models examined trends over time. Fine and Gray's models identified therapy effects controlling for cancer and demographic confounders. Of 374,408 survivors, 1,369 had an HPV-SMN, occurring on average 5 years after first cancer. Compared with the general population, AYA survivors had 70% increased risk for any HPV-SMN [95% confidence interval (CI), 1.61–1.79] and 117% for oropharyngeal-SMN (95% CI, 2.00–2.35); cervical-SMN risk was generally lower in survivors (SIR, 0.85; 95% CI, 0.76–0.95), but Hispanic AYA survivors had a 8.4 significant increase in cervical-SMN (SIR, 1.46; 95% CI, 1.01–2.06). AYAs first diagnosed with Kaposi sarcoma, leukemia, Hodgkin, and non-Hodgkin lymphoma had increased HPV-SMN risks compared with the general population. Oropharyngeal-SMN incidence declined over time in APC models. Chemotherapy and radiation were associated with any HPV-SMN among survivors with first HPV-related cancers, but not associated among survivors whose first cancers were not HPV-related. HPV-SMN in AYA survivors are driven by oropharyngeal cancers despite temporal declines in oropharyngeal-SMN. Hispanic survivors are at risk for cervical-SMN relative to the general population. Encouraging HPV vaccination and cervical and oral cancer screenings may reduce HPV-SMN burden among AYA survivors.

60 APPLIED LIFE SCIENCES↗

SU-E-T-586: Optimal Determination of Tolerance Level for Radiation Dose Delivery Verification in An in Vivo Dosimetry System

Purpose: To statistically determine the optimal tolerance level in the verification of delivery dose compared to the planned dose in an in vivo dosimetry system in radiotherapy. Methods: The LANDAUER MicroSTARii dosimetry system with screened nanoDots (optically stimulated luminescence dosimeters) was used for in vivo dose measurements. Ideally, the measured dose should match with the planned dose and falls within a normal distribution. Any deviation from the normal distribution may be redeemed as a mismatch, therefore a potential sign of the dose misadministration. Randomly mis-positioned nanoDots can yield a continuum background distribution. A percentage difference of the measured dose to its corresponding planned dose (ΔD) can be used to analyze combined data sets for different patients. A model of a Gaussian plus a flat function was used to fit the ΔD distribution. Results: Total 434 nanoDot measurements for breast cancer patients were collected across a period of three months. The fit yields a Gaussian mean of 2.9% and a standard deviation (SD) of 5.3%. The observed shift of the mean from zero is attributed to the machine output bias and calibration of the dosimetry system. A pass interval of −2SD to +2SD was applied and a mismatch background was estimated to be 4.8%. With such a tolerance level, one can expect that 99.99% of patients should pass the verification and at most 0.011% might have a potential dose misadministration that may not be detected after 3 times of repeated measurements. After implementation, a number of new start breast cancer patients were monitored and the measured pass rate is consistent with the model prediction. Conclusion: It is feasible to implement an optimal tolerance level in order to maintain a low limit of potential dose misadministration while still to keep a relatively high pass rate in radiotherapy delivery verification.

61 RADIATION PROTECTION AND DOSIMETRY↗

Uncertainty in Synthetic Tropical Cyclone Hazard and Risk Estimates: Insights from RAFT, CHAZ, MIT, STORM, and CLIMADA

We synthesize five complementary tropical cyclone (TC) hazard frameworks—RAFT (physics-based machine learning), CHAZ and MIT (statistical–dynamical), STORM (fully statistical), and CLIMADA (observation-driven resampling)—to characterize uncertainty in wind-related TC metrics relevant to energy applications. All datasets and the IBTrACS observational record are harmonized to a common 6-hourly, 2.5° grid. We compare basin-wide and coastal properties using consistent definitions for TC frequency, mean and maximum intensity, 24-hour intensification, and 6-hour translation speed, and quantify agreement with Pearson r, RMSE, and Kling–Gupta efficiency (KGE) alongside resampling-based confidence intervals. CLIMADA is included for basin context but excluded from coastal skill scoring because it resamples historical IBTrACS; if supplied with projected future tracks from an external hazard model, CLIMADA can be used to simulate future TC scenarios. Results show robust, cross-model signals: (i) a corridor of activity from the tropical Atlantic through the Caribbean into the Bahamas and western subtropical Atlantic; (ii) a meridional dipole in 24-hour intensification (low-latitude strengthening, subtropical weakening); and (iii) a transition from slower tropical motion to faster midlatitude translation. Coastal winds (mean and maximum) consistently cluster from the eastern Gulf into the Bahamas–western Atlantic transition. The largest structural spread occurs in the amplitude and footprint of lifetime maximum intensity and, secondarily, in translation speed; intensification exhibits similar central behavior across frameworks with variability in extremes. Translation speed shows the most uniform coastal agreement. These findings provide a decision envelope for wind-focused risk screening and clarify where uncertainty should be carried forward; wind-only results represent a lower bound on total hazard, motivating integration of surge and rainfall modules and a companion, asset-level damage analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

1-D profiling using highly dispersive guided waves

Corrosion is one of the industries major issues regarding the integrity of assets. Currently, inspections are conducted at regular intervals to ensure a sufficient integrity level of these assets. Cost reduction while maintaining a high level of reliability and safety of installations is a major challenge. There are many situations where the actual defect location is not accessible, e.g., a pipe support or a partially buried pipe. Guided wave tomography has been developed to reconstruct the wall thickness of steel pipes. In case of bottom of the line corrosion, i.e., a single corrosion pit, a simpler approach may be followed. Data is collected in a pitch-catch configuration at the 12 o'clock position using highly dispersive guided waves. After dispersion correction the data collapses to a short pulse, any residual dispersion indicates wall loss. The phase spectrum is used to invert for the wall thickness profile in the circumferential direction, assuming a Gaussian defect profile. The approach is evaluated on numerically simulated and on measured data. The method is intended for rapid, semi-quantitative screening of pipes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantification of uncertainties in thermoelectric properties of materials from a first-principles prediction method: An approach based on Gaussian process regression

We present the electron-phonon averaged via Gaussian process regression (EPA-GPR) method, in which the electron-phonon coupling matrix is represented as a function of two energies and is in turn modeled as a Gaussian process. The EPA-GPR method can be used as an efficient method to estimate thermoelectric properties of materials for fast-screening applications, comparable to the original electron-phonon averaged (EPA) method and the electron-phonon averaged via moving-least-squares (EPA-MLS) method. The EPA-GPR method does not require specification of any open parameter, unlike the other EPA-related methods, since all the hyperparameters in the model can be unambiguously estimated within the type II maximum likelihood (ML-II) approximation. Thus, the EPA-GPR method is a parameter-free estimation method. Additionally, the concept of Gaussian processes in the EPA-GPR method allows us to quantify the uncertainty in estimated properties of thermoelectric materials. One can randomly realize the electron-phonon coupling coefficients from the identified Gaussian process, and those realized samples can be further analyzed in the solution process of the semiclassical Boltzmann transport equation for charge carriers. The results of the semiclassical Boltzmann transport equation provide the statistical properties of the thermoelectric properties of interest. The means, standard deviations, histograms, and confidence intervals of the Seebeck coefficient, the electrical conductivity, and the power factor can be constructed and analyzed. Furthermore the proposed EPA-GPR method is applied to a p-type half-Heusler compound, i.e., HfCoSb, as a case example, the results of which clearly present the advantages of the method.

30 DIRECT ENERGY CONVERSION↗

Effective field theory for quantum liquid in dwarf stars

An effective field theory approach is used to describe quantum matter at greater-than-atomic but less-than-nuclear densities which are encountered in white dwarf stars. We focus on the density and temperature regime for which charged spin-0 nuclei form an interacting charged Bose-Einstein condensate, while the neutralizing electrons form a degenerate fermi gas. After a brief introductory review, we summarize distinctive properties of the charged condensate, such as a mass gap in the bosonic sector as well as gapless fermionic excitations. Charged impurities placed in the condensate are screened with great efficiency, greater than in an equivalent uncondensed plasma. We discuss a generalization of the Friedel potential which takes into account bosonic collective excitations in addition to the fermionic excitations. We argue that the charged condensate could exist in helium-core white dwarf stars and discuss the evolution of these dwarfs. Condensation would lead to a significantly faster rate of cooling than that of carbon- or oxygen-core dwarfs with crystallized cores. This prediction can be tested observationally: signatures of charged condensation may have already been seen in the recently discovered sequence of helium-core dwarfs in the nearby globular cluster NGC 6397. Sufficiently strong magnetic fields can penetrate the condensate within Abrikosov-like vortices. We find approximate analytic vortex solutions and calculate the values of the lower and upper critical magnetic fields at which vortices are formed and destroyed respectively. The lower critical field is within the range of fields observed in white dwarfs, but tends toward the higher end of this interval. This suggests that for a significant fraction of helium-core dwarfs, magnetic fields are entirely expelled within the core.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparative Effectiveness of 5 Treatment Strategies for Early-Stage Non-Small Cell Lung Cancer in the Elderly

Purpose: The incidence of early-stage non-small cell lung cancer (NSCLC) among older adults is expected to increase because of demographic trends and computed tomography-based screening; yet, optimal treatment in the elderly remains controversial. Using the Surveillance, Epidemiology, and End Results (SEER)-Medicare cohort spanning 2001-2007, we compared survival outcomes associated with 5 strategies used in contemporary practice: lobectomy, sublobar resection, conventional radiation therapy, stereotactic ablative radiation therapy (SABR), and observation. Methods and Materials: Treatment strategy and covariates were determined in 10,923 patients aged {>=}66 years with stage IA-IB NSCLC. Cox regression, adjusted for patient and tumor factors, compared overall and disease-specific survival for the 5 strategies. In a second exploratory analysis, propensity-score matching was used for comparison of SABR with other options. Results: The median age was 75 years, and 29% had moderate to severe comorbidities. Treatment distribution was lobectomy (59%), sublobar resection (11.7%), conventional radiation (14.8%), observation (12.6%), and SABR (1.1%). In Cox regression analysis with a median follow-up time of 3.2 years, SABR was associated with the lowest risk of death within 6 months of diagnosis (hazard ratio [HR] 0.48; 95% confidence interval [CI] 0.38-0.63; referent is lobectomy). After 6 months, lobectomy was associated with the best overall and disease-specific survival. In the propensity-score matched analysis, survival after SABR was similar to that after lobectomy (HR 0.71; 95% CI 0.45-1.12; referent is SABR). Conventional radiation and observation were associated with poor outcomes in all analyses. Conclusions: In this population-based experience, lobectomy was associated with the best long-term outcomes in fit elderly patients with early-stage NSCLC. Exploratory analysis of SABR early adopters suggests efficacy comparable with that of surgery in select populations. Evaluation of these therapies in randomized trials is urgently needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

March-June 2009 monitoring results for Barnes, Kansas.

The Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) operated a grain storage facility at Barnes, Kansas, during most of the interval 1949-1974. Carbon tetrachloride contamination was initially detected in 1986 in the town's public water supply wells. In 2006-2007, the CCC/USDA conducted a comprehensive targeted investigation at and near its former property in Barnes to characterize this contamination. Those results were reported previously (Argonne 2008a). In November 2007, the CCC/USDA began quarterly groundwater monitoring at Barnes. The monitoring is being conducted on behalf of the CCC/USDA by Argonne National Laboratory, in accord with the recommendations made in the report for the 2006-2007 targeted investigation (Argonne 2008a). The objective is to monitor the carbon tetrachloride contamination identified in the groundwater at Barnes. The sampling is presently conducted in a network of 28 individual monitoring wells (at 19 distinct locations), 2 public water supply wells, and 1 private well (Figure 1.1). The results of the 2006-2007 targeted investigation and the subsequent monitoring events (Argonne 2008a-d, 2009) demonstrated the presence of carbon tetrachloride contamination in groundwater at levels exceeding the Kansas Department of Health and Environment (KDHE) Tier 2 risk-based screening level (RBSL) of 5.0 {micro}g/L for this compound. The contaminant plume appears to extend from the former CCC/USDA property northwestward, toward the Barnes public water supply wells. Information obtained during the 2006-2007 investigation indicates that at least one other potential source might have contributed to the groundwater contaminant plume (Argonne 2008a). The former agriculture building owned by the local school district, located immediately east of well PWS3, is also a potential source of the contamination. This current report presents the results of the fifth and sixth quarterly monitoring events, conducted in March and June 2009. During these two monitoring events, low-flow sampling methods were used to purge and sample all wells. These were the fourth and fifth events at Barnes during which the low-flow sampling method was used.

54 ENVIRONMENTAL SCIENCES↗

High-throughput prediction of Acacia and eucalypt lignin syringyl/guaiacyl content using FT-Raman spectroscopy and partial least squares modeling

High-throughput techniques are necessary to efficiently screen potential lignocellulosic feedstocks for the production of renewable fuels, chemicals, and bio-based materials, thereby reducing experimental time and expense while supplanting tedious, destructive methods. The ratio of lignin syringyl (S) to guaiacyl (G) monomers has been routinely quantified as a way to probe biomass recalcitrance. Mid-infrared and Raman spectroscopy have been demonstrated to produce robust partial least squares models for the prediction of lignin S/G ratios in a diverse group of Acacia and eucalypt trees. The most accurate Raman model has now been used to predict the S/G ratio from 269 unknown Acacia and eucalypt feedstocks. This study demonstrates the application of a partial least squares model composed of Raman spectral data and lignin S/G ratios measured using pyrolysis/molecular beam mass spectrometry (pyMBMS) for the prediction of S/G ratios in an unknown data set. The predicted S/G ratios calculated by the model were averaged according to plant species, and the means were not found to differ from the pyMBMS ratios when evaluating the mean values of each method within the 95 % confidence interval. Pairwise comparisons within each data set were employed to assess statistical differences between each biomass species. While some pairwise appraisals failed to differentiate between species, Acacias , in both data sets, clearly display significant differences in their S/G composition which distinguish them from eucalypts. In conclusion, this research shows the power of using Raman spectroscopy to supplant tedious, destructive methods for the evaluation of the lignin S/G ratio of diverse plant biomass materials.

09 BIOMASS FUELS↗

Semi-annual monitoring report for Barnes, Kansas, for July-December 2009.

The Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) operated a grain storage facility at Barnes, Kansas, during most of the interval 1949-1974. Carbon tetrachloride contamination was initially detected in 1986 in the town's public water supply wells. In 2006-2007, the CCC/USDA conducted a comprehensive targeted investigation at and near its former property in Barnes to characterize this contamination. Those results were reported previously (Argonne 2008a). In November 2007, the CCC/USDA began quarterly groundwater monitoring at Barnes. The monitoring is being conducted on behalf of the CCC/USDA by Argonne National Laboratory, in accord with the recommendations made in the report for the 2006-2007 targeted investigation (Argonne 2008a). The objective is to monitor the carbon tetrachloride contamination identified in the groundwater at Barnes. The sampling is presently conducted in a network of 28 individual monitoring wells (at 19 distinct locations), 2 public water supply wells, and 1 private well (Figure 1.1). The results of the 2006-2007 targeted investigation and the subsequent monitoring events (Argonne 2008a-d, 2009a,b) demonstrated the presence of carbon tetrachloride contamination in groundwater at levels exceeding the Kansas Department of Health and Environment (KDHE) Tier 2 risk-based screening level (RBSL) of 5.0 {micro}g/L for this compound. The contaminant plume appears to extend from the former CCC/USDA property northwestward, toward the Barnes public water supply wells. Information obtained during the 2006-2007 investigation indicates that at least one other potential source might have contributed to the groundwater contaminant plume (Argonne 2008a). The former agriculture building owned by the local school district, located immediately east of well PWS3, is also a potential source of the contamination. This current report presents the results of the seventh quarterly monitoring event, conducted in September-October, and also sampling of only the public wells in December 2009. During the September-October quarterly event, low-flow sampling methods were used to purge and sample all wells. This was the seventh event at Barnes during which the low-flow sampling method was used. After the September-October 2009 quarterly sampling event, the KDHE (2009) approved a change in the sampling frequency for the monitoring wells from quarterly to twice yearly. Quarterly sampling is to continue for the public water supply wells. Accordingly, in December 2009, only the public wells were sampled. All results for the six-month period July-December 2009 are reported here.

54 ENVIRONMENTAL SCIENCES↗

Changes in plasma vasopressin during motion sickness in cats

Changes in levels of plasma vasopressin (AVP) and cortisol (C) have been shown to be correlated with motion sickness and nausea in man. As part of the research aimed at validation of the cat as an appropriate animal model for motion sickness research, levels of these hormones were investigated in the cat during motion sickness elicited by vertical linear acceleration of approximately 0.6 Hz and 1 +/- 0.6 G. In Study 1, 15 cats previously screened for susceptibility to motion sickness were prepared with indwelling jugular catheters to permit withdrawl of blood with minimal disruption of the stimulus and minimum stress to the animal. AVP and C were measured in blood samples obtained during exposure to vertical linear acceleration and during control sessions in which the animals were placed in the stationary apparatus. 10 min and 1 min prior to duration; 1, 5, 10, and 20 min after start of motion. Total duration of exposure to motion was 20 min. The data indicate that both AVP and C are elevated during exposure to motion if emesis occurs. AVP reaches maximum levels during or about the same time as emesis, while C increases gradually throughout the period of vertical acceleration. In Study 2, four cats were prepared with indwelling catheters and AVP was measured in blood withdrawn during exposure to the vertical linear acceleration. A single pre-motion sample consisting of three samples drawn 5 min prior to motion onset. Two series of samples consisting of three samples drawn at 3-min intervals were obtained during motion. The first series was initiated at emesis, and the second 25 min after emesis. Results show that levels of circulating AVP were elevated (2 to 27 times the control and pre-motion levels) in the samples taken during emesis and decreased, but remained 1 to 6 times above the pre-motion or control levels within 25 min. The results of these two studies indicate that AVP is elevated during motion-produced emesis than is C. These findings are in general agreement with those obtained from humans under motion sickness conditions, and indicate that it is appropriate to continue to use the cat in studies of hormone changes during motion sickness.

R Fox↗

Remote Measurement of Atmospheric Temperatures By Raman Lidar

The Raman shifted return of a lidar, or optical radar, system has been utilized to make atmospheric temperature measurements. These measurements were made along a horizontal path at temperatures between -20 C and +30 C and at ranges of about 100 meters. The temperature data were acquired by recording the intensity ratio of two portions of the Raman spectrum which were simultaneously sampled from a preset range. The lidar unit employed in this testing consisted of a 4 joule-10ppm laser operating at 694.3 nm, a 10-inch Schmidt-Cassegrain telescope, and a system of time-gated detection and signal processing electronics. The detection system processed three return signal wavelength intervals - two intervals along the rotational Raman scattered spectrum and one interval centered at the Rayleigh-Mie scattered wavelength. The wavelength intervals were resolved by using a pellicle beam splitter and three optical interference filters. Raman return samples were taken from one discrete range segment during each test shot and the signal intensities were displayed in digital format. The Rayleigh-Mie techniques. The test site utilized to evaluate this measurement technique encompassed a total path length of 200 meters. Major components of the test site included a trailer-van housing the lidar unit, a controlled environment test zone, and a beam terminator. The control zone which was located about 100 meters from the trailer was 12 meters in length, 2.4 meters in diameter, and was equipped with hinged doors at each end. The temperature of the air inside the zone could be either raised or lowered with respect to ambient air through the use of infrared heaters or a liquid-nitrogen cooling system. Conditions inside the zone were continuously monitored with a thermocouple rake assembly. The test path length was terminated by a 1.2 meter square array of energy absorbing cones and a flat black screen. Tests were initially conducted at strictly ambient conditions utilizing the normal outside air temperatures as a test parameter. These tests provided a calibration of the Raman intensity ratio as a function of' temperature for the particular optical-filter arrangement used in this system while also providing a test of' the theoretical prediction formulated in the design of the system. Later tests utilized zone temperatures above and below ambient to provide temperature gradient data. These tests indicate that ten shots, or one minute of' data acquisition, from a 100 meter range can provide absolute temperature measurements with an accuracy of + 30 C and a range resolution of about 5 meters. Because this measurement accuracy compares well with that predicted for this particular unit, it is suggested that a field-application system could be built with signif'icant improvements in both absolute accuracy and range.

Salzman, Jack A.↗

Delta L: An Apparatus for Measuring Macromolecule Crystal Growth Rates in Microgravity

Strongly diffracting high quality macromolecule crystals of suitable volume are keenly sought for X-ray diffraction analysis so that high-resolution molecular structure data can be obtained. Such data is of tremendous value to medical research, agriculture and commercial biotechnology. In previous studies by many investigators microgravity has been reported in some instances to improve biological macromolecule X-ray crystal quality while little or no improvement was observed in other cases. A better understanding of processes effecting crystal quality improvement in microgravity will therefore be of great benefit in optimizing crystallization success in microgravity. In ground based research with the protein lysozyme we have previously shown that a population of crystals grown under the same solution conditions, exhibit a variation in X-ray diffraction properties (Judge et al., 1999). We have also observed that under the same solution conditions, individual crystals will grow at slightly different growth rates. This phenomenon is called growth rate dispersion. For small molecule materials growth rate dispersion has been directly related to crystal quality (Cunningham et al., 1991; Ristic et al., 1991). We therefore postulate that microgravity may act to improve crystal quality by reducing growth rate dispersion. If this is the case then as different, Materials exhibit different degrees of growth rate dispersion on the ground then growth rate dispersion could be used to screen which materials may benefit the most from microgravity crystallization. In order to assess this theory the Delta L hardware is being developed so that macromolecule crystal growth rates can be measured in microgravity. Crystal growth rate is defined as the change or delta in crystal size (defined as a characteristic length, L) over time; hence the name of the hardware. Delta L will consist of an optics, a fluids, and a data acquisition sub-assemblies. The optics assembly will consist of a video microscope camera mounted on three axis computer controlled translation stages. The fluids assembly consists of macromolecule and precipitant reservoirs, a temperature controlled growth cell and waste container, The data acquisition is achieved by using a frame-gabber, with images being stored on a hard drive. In operation, macromolecule and precipitant solution will be injected into the temperature controlled growth cell. As macromolecule crystals grow, the video microscope camera controlled by the translation stages, will be used to locate and record images of individual crystals, returning to the same crystals at specific time intervals. The images will be stored on the hard drive and used to calculate the crystal growth rate. To prevent vibrations interfering in the crystal growth rate measurements (Snell et al., 1997) Delta L will be used in connection with the Glovebox Integrated Microgravity Isolation Technology (g-LIMIT) inside the Microgravity Science Glovebox (MSG), onboard the International Space Station (ISS).

Judge, Russell A.↗

July 2008 monitoring results for Barnes, Kansas.

The Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) operated a grain storage facility at Barnes, Kansas, during most of the interval 1949-1974. Carbon tetrachloride contamination was initially detected in 1986 in the town's public water supply wells. In 2006-2007, the CCC/USDA conducted a comprehensive targeted investigation at and near its former property in Barnes to characterize this contamination. Those results were reported previously (Argonne 2008a). In November 2007, the CCC/USDA began quarterly groundwater monitoring at Barnes. The monitoring is being conducted on behalf of the CCC/USDA by Argonne National Laboratory, in accord with the recommendations made in the report for the 2006-2007 targeted investigation (Argonne 2008a). The objective is to monitor the carbon tetrachloride contamination identified in the groundwater at Barnes. The sampling is presently conducted in a network of 28 individual monitoring wells (at 19 distinct locations), 2 public water supply wells, and 1 private well (Figure 1.1). The results of the 2006-2007 targeted investigation and the subsequent monitoring events in November 2007 (Argonne 2008b) and March 2008 (Argonne 2008c) demonstrated the presence of carbon tetrachloride contamination in groundwater at levels slightly exceeding the Kansas Department of Health and Environment (KDHE) Tier 2 risk-based screening level (RBSL) of 5.0 {micro}g/L for this compound. The contaminant plume appears to extend from the former CCC/USDA property northwestward, toward the Barnes public water supply wells. Information obtained during the 2006-2007 investigations indicates that at least one other potential source might have contributed to the groundwater contaminant plume (Argonne 2008a). This current report presents the results of the third monitoring event, conducted in July 2008. During this third monitoring event, low-flow sampling methods were used to purge and sample all wells. This was the second event at Barnes during which low-flow sampling methods were used.

54 ENVIRONMENTAL SCIENCES↗

Empirical correlations for prediction of minimum miscible pressure and near-miscible pressure interval for oil and CO 2 systems

Although near-miscible CO 2 flooding has recently received considerable attention, no criteria are available to predict its applicability to a specific reservoir. Evaluating the viability of near-miscible flooding requires experimental exploration of a specific region in pressure–temperature space. The near-miscible pressure field is bounded on one side in P, T space by the MMP (minimum miscible pressure). This paper provides robust empirical correlations to estimate the MMP for both pure and impure CO 2 and for prediction of the near-miscible pressure region for CO 2 -oil. Many slim tube analyses, lacking high density data points, systematically underestimate the MMP, when the near miscible region is not accounted for. They are based on 147 published data sets that include: slim tube experimental determination of MMP; interfacial tension (IFT) between oil and CO 2 ; concentration of solution gas; and purity of the CO 2 . This paper is the first to begin a systematic exploration of the pressure-temperature space within which near-miscible effects characterize CO 2 floods. Our new correlations provide a basis for identifying and investigating the nature of near miscible effects associated with existing CO 2 floods. For a case study of an offshore field we determined that lower and upper pressure boundaries for effective near-miscible flooding, are 0.87 MMP and 1.07 MMP at reservoir temperatures. The proposed model is the first empirical correlation for the prediction of near-miscible pressure region, it will provide the basis for both screening the relative potential of oil reservoirs for economically viable miscible or near-miscible CO 2 -flooding.

42 ENGINEERING↗

Real-Time Dynamic Brake Assessment Proof of Concept Final Report

This proof-of-concept research was performed to explore the feasibility of using real-world braking data from commercial motor vehicles to make a diagnosis of brake condition similar to that of the performance-based brake tester (PBBT). This was done by determining the relationship between pressure and brake force (P-BF), compensating for the gross vehicle weight (GVW). The nature of this P-BF relationship (e.g., low braking force for a given brake application pressure) may indicate brake system problems. In order to determine the relationship between brake force and brake application pressure, a few key parameters of duty cycle information were collected. Because braking events are often brief, spanning only a few seconds, a sample rate of 10 Hz was needed. The algorithm under development required brake application pressure and speed (from which deceleration was calculated). Accurate weight estimation was also needed to properly derive the braking force from the deceleration. In order to ensure that braking force was the predominant factor in deceleration for the segments of data used in analysis, the data was screened for grade as well. Also, the analysis needed to be based on pressures above the crack pressure. The crack pressure is the pressure below which the individual brakes are not applied due the nature of the mechanical system. This value, which may vary somewhat from one wheel end to another, is approximately 10 psi. Therefore, only pressures 15 psi and above were used in the analysis. The Department of Energy s Medium Truck Duty Cycle research has indicated that under the real-world circumstances of the test vehicle brake pressures of up to approximately 30 psi can be expected. Several different types of data were collected during the testing task of this project. Constant-pressure stopping tests were conducted at several combinations of brake application pressure (15, 20, 25, and 30 psi), load conditions (moderately and fully laden), and speeds (20 and 30 mph). Data was collected at 10 Hz. Standard and stepped-pressure performance-based brake tests with brake pressure transducers were performed for each loading condition. The stepped-pressure test included the constant-pressure intervals of brake application at 15, 20, 25, and 30 psi. The PBBT data files included 10 Hz streaming data collected during the testing of each axle. Two weeks of real-world duty cycle (driving and braking) data was also collected at 10 Hz. Initial analysis of the data revealed that the data collected in the field (i.e., day-to-day operations) provided the same information as that obtained from the controlled tests. Analysis of the data collected revealed a strong linear relationship between brake application pressure and deceleration for given GVWs. As anticipated, initial speed was not found to be a significant factor in the deceleration-pressure relationship, unlike GVW. The positive results obtained from this proof of concept test point to the need for further research to expand this concept. A second phase should include testing over a wider range of speeds and include medium brake application pressures in addition to the low pressures tested in this research. Testing on multiple vehicles would also be of value. This future phase should involve testing to determine how degradation of braking performance affects the pressure-deceleration relationship.

99 GENERAL AND MISCELLANEOUS↗