Search NASA⌕ Search

SEARCH · Search NASA

Results for “selective contacts”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Nanopinhole Passivating Contact Si Solar Cells Fabricated with Metal-Assisted Chemical Etching

Monocrystalline Si (c-Si) solar cells with passivating contacts based on doped polycrystalline Si (poly-Si) on ≈2.0 nm silicon oxide (SiO x ) require >1000 °C thermal processing to create conducting pinholes in the SiO x layer. However, this high thermal budget can induce bulk defects in the Czochralski c-Si wafers used as the cell absorber layer. We demonstrate that pinholes can instead be created using metal-assisted chemical etching on planar or textured morphologies, at room temperature. This wet process creates up to 200 nm wide conducting pinholes that are directly observed with transmission electron and atomic force microscopies. High-performance hole-selective poly-Si/SiN y /SiO x and electron-selective poly-Si/SiO x passivating contacts are fabricated and implemented in laboratory-scale solar cells. This process development significantly broadens the range of passivation layer materials, their thicknesses, and surface morphologies, which enables the design of poly-Si contacts with superior passivating quality.

14 SOLAR ENERGY↗

Vapor‐Phase Infiltrated Organic–Inorganic Positive‐Tone Hybrid Photoresist for Extreme UV Lithography

Abstract Continuing extreme downscaling of semiconductor devices, essential for high performance and energy efficiency of future microelectronics, hinges on extreme ultraviolet lithography (EUVL) and addressing associated challenges. One of such challenges is a need for improved EUV photoresists featuring simultaneously high sensitivity, resolution, and etch selectivity. Here, a new, positive‐tone, organic–inorganic hybrid EUV photoresist is demonstrated that delivers a high‐resolution EUVL and electron‐beam lithography (EBL) patterning capability combined with high sensitivity and etch resistance. The new resist, poly(methyl methacrylate) infiltrated with indium oxide (PMMA‐InO x ), is synthesized via vapor‐phase infiltration (VPI), a material hybridization technique derived from atomic layer deposition. The weak binding of the gaseous indium precursor, trimethylindium, to the carbonyl group in PMMA allows the synthesis of hybrids with inorganic content distributed uniformly in the resist, enabling high EUVL and EBL sensitivities (18 mJ cm −2 and 300 µC cm −2 , respectively) and high‐resolution positive‐tone EUVL patterning (e.g., 40 nm half‐pitch line‐space and 50 nm diameter contact hole patterns) with high Si etch selectivity (>30–40). The low exposure doses required to pattern the PMMA‐InO x hybrid resist, high etch resistance, and processing strategies, which are developed, can pave the way for using infiltration‐synthesized hybrid thin films as reliable positive‐tone EUV photoresists for future semiconductor patterning.

36 MATERIALS SCIENCE↗

Solid Surface Wetting and the Deployment of Drops in Microgravity

The complete or partial deployment of liquid samples in low gravity is primarily influenced by the interfacial properties of the specific liquid and solid materials used because the overwhelming bias of the Earth gravitational acceleration is removed. This study addresses the engineering aspects of injecting and deploying drops of prescribed volume into an acoustic positioning chamber in microgravity. The specific problems of interest are the design, testing, and implementation of injector tips to be used in a simuttaneously retracting dual-injector system used in the Drop Physics Module microgravity experiment facility. Prior to release, the liquid to be deployed must be retained within a restricted area at the very end of the injectors even under dynamic stimuli due to continuous injection flow as well as to the stepped motion of the injectors, and the final released drop must have a well determined volume as well as negligible residual linear or angular momentum from the deployment process. The outcome of Earthbased short-duration low gravity experiments had been the selection of two types of injector tips which were flown as back-up parts and were successfully utilized during the USML-1 Spacelab mission. The combination of a larger contact surface, liquid pinning with a sharp edge, and selective coating of strategic tip surfaces with a non-wetting compound has allowed a significant increase in the success rate of deployment of simple and compound drops of aqueous solutions of glycerol and silicone oil. The diameter of the samples studied in the Drop Physics Module ranged between 0.3 and 2.7 cm. The tests conducted onsrbit with a manually operated small device have allowed the calibration of the volume deployed for a few drop sizes. The design for improved tips to be used during the next USML flight is based on these results.

Trinh, E. H.↗

Development of a Flotation Simulator That Can Predict Grade vs. Recovery Curves from Mineral Liberation Data

Flotation is a kinetic process designed to separate mineral fines by control of hydrophobicity. In general, both the recovery and selectivity of a flotation process increase with contact angle. It is difficult, however, to model flotation kinetics using the thermodynamic parameter. In the present work, we consider flotation as heterocoagulation so that the bubble-particle interactions occurring in the pulp phase of a flotation cell can be modeled using the hydrophobic force as a kinetic parameter that can represent the role of contact angles in flotation. Here, the pulp-phase model developed in this manner has been combined with a froth-phase model developed earlier by considering the effect of particles in film thinning kinetics and bubble coarsening (Park et al, 2018). The combined model has been used to develop a flotation simulator that can be used to construct grade vs. recovery curves from feed characteristics (e.g., mineral liberation and particle size) and various operating parameters. The simulator has been tested successfully against a set of bench-scale continuous flotation test results reported in the literature (dos Santos and Galery, 2018).

58 GEOSCIENCES↗

AlN/AlGaN/AlN quantum well channel HEMTs

We present a compositional dependence study of electrical characteristics of AlxGa1−xN quantum well channel-based AlN/AlGaN/AlN high electron mobility transistors (HEMTs) with x=0.25,0.44, and 0.58. This ultra-wide bandgap heterostructure is a candidate for next-generation radio frequency and power electronics. The use of selectively regrown n-type GaN Ohmic contacts results in contact resistance that increases as the Al content of the channel increases. The DC HEMT device characteristics reveal that the maximum drain current densities progressively reduce from 280 to 30 to 1.7 mA/mm for x=0.25,0.44, and 0.58, respectively. This is accompanied by a simultaneous decrease (in magnitude) in threshold voltage from −5.2 to −4.9 to −2.4 V for the three HEMTs. This systematic experimental study of the effects of Al composition x on the transistor characteristics provides valuable insights for engineering AlGaN channel HEMTs on AlN for extreme electronics at high voltages and high temperatures.

Physics↗

Spin-induced asymmetry reaction—The formation of asymmetric carbon by electropolymerization

We describe the spin polarization–induced chirogenic electropolymerization of achiral 2-vinylpyridine, which forms a layer of enantioenhanced isotactic polymer on the electrode. The product formed is enantioenriched in asymmetric carbon polymer. To confirm the chirality of the polymer film formed on the electrode, we also measured its electron spin polarization properties as a function of its thickness. Two methods were used: First, spin polarization was measured by applying magnetic contact atomic force microscopy, and second, magnetoresistance was assessed in a sandwich-like four-point contact structure. We observed high spin-selective electron transmission, even for a layer thickness of 120 nm. A correlation exists between the change in the circular dichroism signal and the change in the spin polarization, as a function of thickness. The spin-filtering efficiency increases with temperature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dialysis system

The improved hemodialysis system utilizes a second polymeric membrane having dialyzate in contact with one surface and a urea decomposition solution in contact with the other surface. The membrane selectively passes urea from the dialyzate into the decomposition solution, while preventing passage of positively charged metal ions from the dialyzate into the solution and ammonium ions from the solution into the dialyzate.

Mueller, W. A.↗

Active heat exchange system development for latent heat thermal energy storage

Various active heat exchange concepts were identified from among three generic categories: scrapers, agitators/vibrators and slurries. The more practical ones were given a more detailed technical evaluation and an economic comparison with a passive tube-shell design for a reference application (300 MW sub t storage for 6 hours). Two concepts were selected for hardware development: (1) a direct contact heat exchanger in which molten salt droplets are injected into a cooler counterflowing stream of liquid metal carrier fluid, and (2) a rotating drum scraper in which molten salt is sprayed onto the circumference of a rotating drum, which contains the fluid salt is sprayed onto the circumference of a rotating drum, which contains the fluid heat sink in an internal annulus near the surface. A fixed scraper blade removes the solidified salt from the surface which was nickel plated to decrease adhesion forces. In addition to improving performance by providing a nearly constant transfer rate during discharge, these active heat exchanger concepts were estimated to cost at least 25% less than the passive tube-shell design.

Alario, J.↗

Active heat exchange system development for latent heat thermal energy storage

Various active heat exchange concepts were identified from among three generic categories: scrapers, agitators/vibrators and slurries. The more practical ones were given a more detailed technical evaluation and an economic comparison with a passive tube-shell design for a reference application. Two concepts selected for hardware development are a direct contact heat exchanger in which molten salt droplets are injected into a cooler counterflowing stream of liquid metal carrier fluid, and a rotating drum scraper in which molten salt is sprayed onto the circumference of a rotating drum, which contains the fluid heat sink in an internal annulus near the surface. A fixed scraper blade removes the solidified salt from the surface which has been nickel plated to decrease adhesion forces. Suitable phase change material (PCM) storage media with melting points in the temperature range of interest (250 C to 400 C) were investigated. The specific salt recommended for laboratory tests was a chloride eutectic (20.5KCl-24/5 NaCl-55.0MgCl 2% by wt.), with a nominal melting point of 385 C.

Alario, J.↗

Integrated Arrays of Ion-Sensitive Electrodes

The figure depicts an example of proposed compact water-quality sensors that would contain integrated arrays of ion-sensitive electrodes (ISEs). These sensors would serve as electronic "tongues": they would be placed in contact with water and used to "taste" selected dissolved ions (that is, they would be used to measure the concentrations of the ions). The selected ions could be any or all of a variety of organic and inorganic cations and anions that could be regarded as contaminants or analytes, depending on the specific application. In addition, some of the ISEs could be made sensitive to some neutral analytes

Buehler, Martin↗

Investigation of Spiral Bevel Gear Condition Indicator Validation via AC-29-2C Combining Test Rig Damage Progression Data with Fielded Rotorcraft Data

This is the final of three reports published on the results of this project. In the first report, results were presented on nineteen tests performed in the NASA Glenn Spiral Bevel Gear Fatigue Test Rig on spiral bevel gear sets designed to simulate helicopter fielded failures. In the second report, fielded helicopter HUMS data from forty helicopters were processed with the same techniques that were applied to spiral bevel rig test data. Twenty of the forty helicopters experienced damage to the spiral bevel gears, while the other twenty helicopters had no known anomalies within the time frame of the datasets. In this report, results from the rig and helicopter data analysis will be compared for differences and similarities in condition indicator (CI) response. Observations and findings using sub-scale rig failure progression tests to validate helicopter gear condition indicators will be presented. In the helicopter, gear health monitoring data was measured when damage occurred and after the gear sets were replaced at two helicopter regimes. For the helicopters or tails, data was taken in the flat pitch ground 101 rotor speed (FPG101) regime. For nine tails, data was also taken at 120 knots true airspeed (120KTA) regime. In the test rig, gear sets were tested until damage initiated and progressed while gear health monitoring data and operational parameters were measured and tooth damage progression documented. For the rig tests, the gear speed was maintained at 3500RPM, a one hour run-in was performed at 4000 in-lb gear torque, than the torque was increased to 8000 in-lbs. The HUMS gear condition indicator data evaluated included Figure of Merit 4 (FM4), Root Mean Square (RMS) or Diagnostic Algorithm 1(DA1), + 3 Sideband Index (SI3) and + 1 Sideband Index (SI1). These were selected based on their sensitivity in detecting contact fatigue damage modes from analytical, experimental and historical helicopter data. For this report, the helicopter dataset was reduced to fourteen tails and the test rig data set was reduced to eight tested gear sets. The damage modes compared were separated into three cases. For case one, both the gear and pinion showed signs of contact fatigue or scuffing damage. For case two, only the pinion showed signs of contact fatigue damage or scuffing. Case three was limited to the gear tests when scuffing occurred immediately after the gear run-in. Results of this investigation highlighted the importance of understanding the complete monitored systems, for both the helicopter and test rig, before interpreting health monitoring data. Further work is required to better define these two systems that include better state awareness of the fielded systems, new sensing technologies, new experimental methods or models that quantify the effect of system design on CI response and new methods for setting thresholds that take into consideration the variance of each system.

spiral bevel gears↗

Solid surface wetting and the deployment of drops in microgravity

The complete or partial deployment of liquid samples in low gravity is primarily influenced by the interfacial properties of the specific liquid and solid materials used because the overwhelming bias of the Earth gravitational acceleration is removed. This study addresses the engineering aspects of injecting and deploying drops of prescribed volume into an acoustic positioning chamber in microgravity. The specific problems of interest are the design, testing, and implementation of injector tips to be used in a simultaneously retracting dual-injector system in the Drop Physics Module microgravity experiment facility. Prior to release, the liquid to be deployed must be retained within a restricted area at the very end of the injectors under dynamic stimuli from the continuous injection flow as well as from the stepped motion of the injectors. The final released drop must have a well determined volume and negligible residual linear or angular momentum. The outcome of Earth-based short-duration low gravity experiments had been the selection of two types of injector tips which were flown as back-up parts. They were successfully utilized during the USML-1 Spacelab mission as the primary tips. The combination of a larger contact surface, liquid pinning with a sharp edge, and selective coating of strategic tip surfaces with a non-wetting compound has allowed a significant increase in the success rate of deployment of simple and compound drops of aqueous solutions of glycerol and silicone oil. The diameter of the samples studied in the Drop Physics Module range between 0.3 and 2.7 cm. The tests conducted on-orbit with a manually operated small device have allowed the calibration of the volume deployed for a few drop sizes. The design for improved tips to be used during the next USML flight is based on these results.

Trinh, E. H.↗

Microwell Arrays for Studying Many Individual Cells

"Laboratory-on-a-chip" devices that enable the simultaneous culturing and interrogation of many individual living cells have been invented. Each such device includes a silicon nitride-coated silicon chip containing an array of micromachined wells sized so that each well can contain one cell in contact or proximity with a patch clamp or other suitable single-cell-interrogating device. At the bottom of each well is a hole, typically 0.5 m wide, that connects the well with one of many channels in a microfluidic network formed in a layer of poly(dimethylsiloxane) on the underside of the chip. The microfluidic network makes it possible to address wells (and, thus, cells) individually to supply them with selected biochemicals. The microfluidic channels also provide electrical contact to the bottoms of the wells.

Folch, Albert↗

Active heat exchange system development for latent heat thermal energy storage

Five tasks to select, design, fabricate, test and evaluate candidate active heat exchanger modules for future applications to solar and conventional utility power plants were discussed. Alternative mechanizations of active heat exchange concepts were analyzed for use with heat of fusion phase change materials (PCMs) in the temperature range of 250 to 350 C. Twenty-six heat exchange concepts were reviewed, and eight were selected for detailed assessment. Two candidates were selected for small-scale experimentation: a coated tube and shell heat exchanger and a direct contact reflux boiler. A dilute eutectic mixture of sodium nitrate and sodium hydroxide was selected as the PCM from over 50 candidate inorganic salt mixtures. Based on a salt screening process, eight major component salts were selected initially for further evaluation. The most attractive major components in the temperature range of 250 to 350 C appeared to be NaNO3, NaNO2, and NaOH. Sketches of the two active heat exchange concepts selected for test are given.

Lefrois, R. T.↗

High Performance Torso Cooling Garment

The concept proposed in this paper is to improve thermal efficiencies of the liquid cooling and ventilation garment (LCVG) in the torso area, which could facilitate removal of LCVG tubing from the arms and legs, thereby increasing suited crew member mobility. EVA space suit mobility in micro-gravity is challenging, and it becomes even more challenging in the gravity of Mars. By using shaped water tubes that greatly increase the contact area with the skin in the torso region of the body, the heat transfer efficiency can be increased. This increase in efficiency could provide the required liquid cooling via torso tubing only; no arm or leg LCVG tubing would be required. Benefits of this approach include increased crewmember mobility, enhanced evaporation cooling, increased comfort during Mars EVA tasks, and easing of the overly dry condition in the helmet associated with the Advanced Extravehicular Mobility Unit (EMU) ventilation loop currently under development. This report describes analysis and test activities performed to evaluate the potential improvements to the thermal performance of the LCVG. Analyses evaluated potential tube shapes for improving the thermal performance of the LCVG. The analysis results fed into the selection of flat flow strips to improve thermal contact with the skin of the suited test subject. Testing of small segments was performed to compare thermal performance of the tubing approach of the current LCVG to the flat flow strips proposed as the new concept. Results of the testing is presented along with recommendations for future development of this new concept.

Conger, Bruce↗

High Performance Torso Cooling Garment

The concept proposed in this paper is to improve thermal efficiencies of the liquid cooling and ventilation garment (LCVG) in the torso area, which could facilitate removal of LCVG tubing from the arms and legs, thereby increasing suited crew member mobility. EVA space suit mobility in micro-gravity is challenging, and it becomes even more challenging in the gravity of Mars. By using shaped water tubes that greatly increase the contact area with the skin in the torso region of the body, the heat transfer efficiency can be increased. This increase in efficiency could provide the required liquid cooling via torso tubing only; no arm or leg LCVG tubing would be required. Benefits of this approach include increased crewmember mobility, reduced LCVG mass, enhanced evaporation cooling, increased comfort during Mars EVA tasks, and easing of the overly dry condition in the helmet associated with the Advanced Extravehicular Mobility Unit (EMU) ventilation loop currently under development. This report describes analysis and test activities performed to evaluate the potential improvements to the thermal performance of the LCVG. Analyses evaluated potential tube shapes for improving the thermal performance of the LCVG. The analysis results fed into the selection of flat flow strips to improve thermal contact with the skin of the suited test subject. Testing of small segments was performed to compare thermal performance of the tubing approach of the current LCVG to the flat flow strips proposed as the new concept. Results of the testing is presented along with recommendations for future development of this new concept.

Conger, Bruce↗

Transmission of Human Influenza A Virus in Pigs Selects for Adaptive Mutations on the HA Gene

Influenza A viruses (FLUAV) cause respiratory diseases in many host species, including humans and pigs. The spillover of FLUAV between swine and humans has been a concern for both public health and the swine industry. With the emergence of the triple reassortant internal gene (TRIG) constellation, establishment of human-origin FLUAVs in pigs has become more common, leading to increased viral diversity. However, little is known about the adaptation processes that are needed for a human-origin FLUAV to transmit and become established in pigs. Here, we generated a reassortant FLUAV (VIC11pTRIG) containing surface gene segments from a human FLUAV strain and internal gene segments from the 2009 pandemic and TRIG FLUAV lineages and demonstrated that it can replicate and transmit in pigs. Sequencing and variant analysis identified three mutants that emerged during replication in pigs, which were mapped near the receptor binding site of the hemagglutinin (HA). The variants replicated more efficiently in differentiated swine tracheal cells compared to the virus containing the wildtype human-origin HA, and one of them was present in all contact pigs. These results show that variants are selected quickly after replication of human-origin HA in pigs, leading to improved fitness in the swine host, likely contributing to transmission.

60 APPLIED LIFE SCIENCES↗

Controlling Catalyst–Semiconductor Contacts: Interfacial Charge Separation in p-InP Photocathodes

Charge-carrier-selective interfaces between electrocatalyst particles and semiconductor light absorbers are critical for solar photochemistry but controlling their properties is challenging. Using thin films and nanoparticle arrays of Pt hydrogen-evolution catalysts on p-InP (a high-performance photocathode material), along with macroscopic and nanoscopic electrical and chemical analysis, we show how hydrogen alloying, the pinch-off effect for nanoscale contacts, and the formation of a native surface oxides all play different roles in creating charge-carrier-selective junctions. As a result, the new insights can be broadly applied to photocathodes, photoanodes, and overall water-splitting systems to control charge-carrier selectivity and improve performance.

14 SOLAR ENERGY↗