Search NASA⌕ Search

SEARCH · Search NASA

Results for “signal visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Detection of emetic activity in the cat by monitoring venous pressure and audio signals

To investigate the use of audio signals as a simple, noninvasive measure of emetic activity, the relationship between the somatic events and sounds associated with retching and vomiting was studied. Thoracic venous pressure obtained from an implanted external jugular catheter was shown to provide a precise measure of the somatic events associated with retching and vomiting. Changes in thoracic venous pressure monitored through an indwelling external jugular catheter with audio signals, obtained from a microphone located above the animal in a test chamber, were compared. In addition, two independent observers visually monitored emetic episodes. Retching and vomiting were induced by injection of xylazine (0.66mg/kg s.c.), or by motion. A unique audio signal at a frequency of approximately 250 Hz is produced at the time of the negative thoracic venous pressure change associated with retching. Sounds with higher frequencies (around 2500 Hz) occur in conjunction with the positive pressure changes associated with vomiting. These specific signals could be discriminated reliably by individuals reviewing the audio recordings of the sessions. Retching and those emetic episodes associated with positive venous pressure changes were detected accurately by audio monitoring, with 90 percent of retches and 100 percent of emetic episodes correctly identified. Retching was detected more accurately (p is less than .05) by audio monitoring than by direct visual observation. However, with visual observation a few incidents in which stomach contents were expelled in the absence of positive pressure changes or detectable sounds were identified. These data suggest that in emetic situations, the expulsion of stomach contents may be accomplished by more than one neuromuscular system and that audio signals can be used to detect emetic episodes associated with thoracic venous pressure changes.

A Nagahara↗

On the Visual Input Driving Human Smooth-Pursuit Eye Movements

Current computational models of smooth-pursuit eye movements assume that the primary visual input is local retinal-image motion (often referred to as retinal slip). However, we show that humans can pursue object motion with considerable accuracy, even in the presence of conflicting local image motion. This finding indicates that the visual cortical area(s) controlling pursuit must be able to perform a spatio-temporal integration of local image motion into a signal related to object motion. We also provide evidence that the object-motion signal that drives pursuit is related to the signal that supports perception. We conclude that current models of pursuit should be modified to include a visual input that encodes perceived object motion and not merely retinal image motion. Finally, our findings suggest that the measurement of eye movements can be used to monitor visual perception, with particular value in applied settings as this non-intrusive approach would not require interrupting ongoing work or training.

Stone, Leland S.↗

From 2D to 4D: a containerized workflow and browser to explore dynamic chromatin architecture

Background Characterizing the physical organization of the genome is essential for understanding long-range gene regulation, chromatin compartmentalization, and epigenetic accessibility. Hi-C experiments generate two-dimensional (2D) genome-wide contact maps of chromatin interactions by capturing the spatial proximity between genomic loci, which reveal interaction frequencies but lack the spatial resolution needed to interpret the three-dimensional (3D) genome structure(s). Emerging evidence suggests that epigenetic regulation is closely linked to 3D genome architecture, and that structural changes over time (4D) drive key biological processes in development, disease, and environmental response. Thus, integrating 3D structure with functional data is critical for a more complete understanding of genome regulation. Previous work, most notably the 4DHiC chromosome modeling framework, has shown that physical multi-dimensional modeling approaches rooted in polymer physics and molecular dynamics can resolve these structures at biologically meaningful resolutions by integrating temporal Hi-C data with physical constraints to uncover dynamic chromosome reorganization. Thus, molecular dynamics simulations, constrained by Hi-C contact matrices, can resolve fine-scale structural changes and reveal functionally significant transitions in chromatin conformation. Results Herein, we present the 4D Genome Browser Workflow (4DGBWorkflow) and the 4D Genome Browser (4DGB). The algorithm is based on the 4DHiC method, and the containerized tool is an end-to-end workflow that can transform, filter, and view 4D epigenomics and chromatin datasets, allowing non-specialists to apply three-dimensional modeling principles to diverse datasets and experimental conditions. The software executes on a laptop running macOS, Linux or Windows. From input Hi-C files (.hic), the 4DGBWorkflow produces 3D reconstructions of chromosomes, integrates the reconstruction with track data (e.g., epigenetic marks, transcriptome profiles), and provides comparative visualization of the results in a single workflow. Conclusions The 4DGBWorkflow and 4D Genome Browser are open-source tools for comparative analysis and visualization of 4D chromosome datasets, including chromatin architecture and epigenomic signals. Automatic integration of Hi-C data with molecular dynamics democratizes the construction of time resolved 3D genome structures, simplifying complex simulations and data integration schemes.

3D Genome Browser↗

Enhanced Lighting Signals for Safety and Efficiency - Experiments With Addressable LEDs

For enhanced roadway safety, clear and immediate visual cues are essential for preventing accidents between drivers and pedestrians. At intersections, however, the line of sight to other roadway users may be obstructed by vehicles and infrastructure. Additionally, adverse conditions, including low visibility, poor weather, or inadequate lighting can increase the potential for collisions. Distracted drivers and pedestrians can further exacerbate the risk of accidents, particularly when using a smartphone, rather than focusing on roadway surroundings. These issues demonstrate the need for infrastructure upgrades that enhance visibility and awareness at crosswalks. A potential solution is through enhanced lighting signals integrated into the roadway infrastructure. One such example is the use of addressable LEDs, individually controllable lights that can change color and brightness instantaneously through programmable microcontrollers. They can be installed and integrated into crosswalks to maintain visibility in conditions where pedestrians may be difficult to see, while also offering peripheral cues to pedestrians who may be distracted by their phones or other objects rather than the road. Such a system (as one example) that is integrated into a traffic intersection digital twin that tracks all roadway users accurately, has the potential to enhance visibility of vulnerable road users, and thus enhance safety. This paper examines the potential implementation and feasibility of this technology, as well as the safety benefits it could provide. Laboratory experiments with addressable LEDs reveal the capabilities and challenges of this technology for roadway infrastructure safety. These findings could pave the way for more integrated lighting in infrastructure for vehicles and pedestrians at intersections, merge and diverge locations, and other areas where complex interactions present safety hazards. Such lighting solutions, enabled by modern computation and communications, could enhance safety and efficiency in our transportation system and improve overall mobility.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Enhanced Lighting Signals for Safety and Efficiency - Experiments with Addressable LEDs

For enhanced roadway safety, clear and immediate visual cues are essential for preventing accidents between drivers and pedestrians. At intersections, however, the line of sight to other roadway users may be obstructed by vehicles and infrastructure. Additionally, adverse conditions, including low visibility, poor weather, or inadequate lighting can increase the potential for collisions. Distracted drivers and pedestrians can further exacerbate the risk of accidents, particularly when using a smartphone, rather than focusing on roadway surroundings. These issues demonstrate the need for infrastructure upgrades that enhance visibility and awareness at crosswalks. A potential solution is through enhanced lighting signals integrated into the roadway infrastructure. One such example is the use of addressable LEDs, individually controllable lights that can change color and brightness instantaneously through programmable microcontrollers. They can be installed and integrated into crosswalks to maintain visibility in conditions where pedestrians may be difficult to see, while also offering peripheral cues to pedestrians who may be distracted by their phones or other objects rather than the road. Such a system (as one example) that is integrated into a traffic intersection digital twin that tracks all roadway users accurately, has the potential to enhance visibility of vulnerable road users, and thus enhance safety. This paper examines the potential implementation and feasibility of this technology, as well as the safety benefits it could provide. Laboratory experiments with addressable LEDs reveal the capabilities and challenges of this technology for roadway infrastructure safety. These findings could pave the way for more integrated lighting in infrastructure for vehicles and pedestrians at intersections, merge and diverge locations, and other areas where complex interactions present safety hazards. Such lighting solutions, enabled by modern computation and communications, could enhance safety and efficiency in our transportation system and improve overall mobility.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Technique for improving solid state mosaic images

Method identifies and corrects mosaic image faults in solid state visual displays and opto-electronic presentation systems. Composite video signals containing faults due to defective sensing elements are corrected by a memory unit that contains the stored fault pattern and supplies the appropriate fault word to the blanking circuit.

Saboe, J. M.↗

Comet Sugano-Saigusa-Fujikawa (1983V) - A small, puzzling comet

Spectroscopic and infrared observations of Comet Sugano-Saigusa-Fujikawa (1983V) were obtained during its close approach to the earth on June 11-14, 1983. The forbidden O I production rates of 1.8 + or - 0.9 x 10 to the 26th atoms/s observed on June 12.3 and 7 + or - 3.5 x 10 to the 26th atoms/s on June 13.4 lead to derived water-production rates of 3 x 10 to the 27th mol/s on June 12 and 1.1 x 10 to the 28th mol/s on June 13. The abundances of the minor species NH2, CN, C2, and C3 are unusually low relative to forbidden O I. The upper limit to the average nuclear radius from infrared and visual photometry on June 12-13 (assuming that the entire signal came from the nucleus) is about 370 m. The dust/gas mass ratio was less than 0.01 on June 12 and less than 0.005 on June 13.

Hanner, M. S.↗

Cooperative control in telerobotics

It is argued that autonomous robotics is not yet feasible, and that instantaneous human control may be difficult because of communication delay and expensive because of labor costs. Therefore, it is argued, human supervisory control with cooperation between man and a partially autonomous distant robot is the most viable engineering solution. Model control of image processing enables efficient visual displays. Cooperative control in paired manipulators required rapid controller signal information to be passed over a cross-filter in a heuristic study.

Stark, Lawrence W.↗

Remote Advanced Payload Test Rig (RAPTR) Portable Payload Test System for the International Space Station (ISS)

The RAPTR was developed to test ISS payloads for NASA. RAPTR is a simulation of the Command and Data Handling (C&DH) interfaces of the ISS (MIL-STD 1553B, Ethernet and TAXI) and is designed to facilitate rapid testing and deployment of payload experiments to the ISS. The ISS Program's goal is to reduce the amount of time it takes a payload developer to build, test and fly a payload, including payload software. The RAPTR meets this need with its user oriented, visually rich interface. Additionally, the Analog and Discrete (A&D) signals of the following payload types may be tested with RAPTR: (1) EXPRESS Sub Rack Payloads; (2) ELC payloads; (3) External Columbus payloads; (4) External Japanese Experiment Module (JEM) payloads. The automated payload configuration setup and payload data inspection infrastructure is found nowhere else in ISS payload test systems. Testing can be done with minimal human intervention and setup, as the RAPTR automatically monitors parameters in the data headers that are sent to, and come from the experiment under test.

Calvert, John↗

Saccades to remembered targets: the effects of smooth pursuit and illusory stimulus motion

1. Measurements were made in four normal human subjects of the accuracy of saccades to remembered locations of targets that were flashed on a 20 x 30 deg random dot display that was either stationary or moving horizontally and sinusoidally at +/-9 deg at 0.3 Hz. During the interval between the target flash and the memory-guided saccade, the "memory period" (1.4 s), subjects either fixated a stationary spot or pursued a spot moving vertically sinusoidally at +/-9 deg at 0.3 Hz. 2. When saccades were made toward the location of targets previously flashed on a stationary background as subjects fixated the stationary spot, median saccadic error was 0.93 deg horizontally and 1.1 deg vertically. These errors were greater than for saccades to visible targets, which had median values of 0.59 deg horizontally and 0.60 deg vertically. 3. When targets were flashed as subjects smoothly pursued a spot that moved vertically across the stationary background, median saccadic error was 1.1 deg horizontally and 1.2 deg vertically, thus being of similar accuracy to when targets were flashed during fixation. In addition, the vertical component of the memory-guided saccade was much more closely correlated with the "spatial error" than with the "retinal error"; this indicated that, when programming the saccade, the brain had taken into account eye movements that occurred during the memory period. 4. When saccades were made to targets flashed during attempted fixation of a stationary spot on a horizontally moving background, a condition that produces a weak Duncker-type illusion of horizontal movement of the primary target, median saccadic error increased horizontally to 3.2 deg but was 1.1 deg vertically. 5. When targets were flashed as subjects smoothly pursued a spot that moved vertically on the horizontally moving background, a condition that induces a strong illusion of diagonal target motion, median saccadic error was 4.0 deg horizontally and 1.5 deg vertically; thus the horizontal error was greater than under any other experimental condition. 6. In most trials, the initial saccade to the remembered target was followed by additional saccades while the subject was still in darkness. These secondary saccades, which were executed in the absence of visual feedback, brought the eye closer to the target location. During paradigms involving horizontal background movement, these corrections were more prominent horizontally than vertically. 7. Further measurements were made in two subjects to determine whether inaccuracy of memory-guided saccades, in the horizontal plane, was due to mislocalization at the time that the target flashed, misrepresentation of the trajectory of the pursuit eye movement during the memory period, or both. 8. The magnitude of the saccadic error, both with and without corrections made in darkness, was mislocalized by approximately 30% of the displacement of the background at the time that the target flashed. The magnitude of the saccadic error also was influenced by net movement of the background during the memory period, corresponding to approximately 25% of net background movement for the initial saccade and approximately 13% for the final eye position achieved in darkness. 9. We formulated simple linear models to test specific hypotheses about which combinations of signals best describe the observed saccadic amplitudes. We tested the possibilities that the brain made an accurate memory of target location and a reliable representation of the eye movement during the memory period, or that one or both of these was corrupted by the illusory visual stimulus. Our data were best accounted for by a model in which both the working memory of target location and the internal representation of the horizontal eye movements were corrupted by the illusory visual stimulus. We conclude that extraretinal signals played only a minor role, in comparison with visual estimates of the direction of gaze, in planning eye movements to remembered targ.

Clinical Trial↗

Signal-to-noise ratio for the wide field-planetary camera of the Space Telescope

Signal-to-noise ratios for the Wide Field Camera and Planetary Camera of the Space Telescope were calculated as a function of integration time. Models of the optical systems and CCD detector arrays were used with a 27th visual magnitude point source and a 25th visual magnitude per arc-sq. second extended source. A 23rd visual magnitude per arc-sq. second background was assumed. The models predicted signal-to-noise ratios of 10 within 4 hours for the point source centered on a signal pixel. Signal-to-noise ratios approaching 10 are estimated for approximately 0.25 x 0.25 arc-second areas within the extended source after 10 hours integration.

Zissa, D. E.↗

On the detectability of infrared echo arcs around supernova 1987A

The ring-like interstellar visual echoes of radii 33 and 54 arcsec detected around SN 1987A should coincide with infrared echoes (thermal reradiation) from dust at T approximately equal to 15 to 30 K. Whether these infrared echoes are detectable at present is considered. They will be brightest at approximately 100 microns, the range of the Texas infrared photometer. Detectability depends on the ratio zeta congruent to tan(sub a)/tan(sub s)P(theta), where tan(sub a) and tan(sub s) are the visual absorption and scattering optical thicknesses of the echo layer, and P is the phase function function for small-angle scattering (theta approximately equal to 2 to 4 degrees). Zeta approximately greater than 1 is needed for a detectable signal (approximately 0.3 Jy), but zeta cannot be much less than 1; otherwise the visual echoes could not be as bright as they are. Typical dust mixtures of Mathis-Rumpl-Nordsieck type have zeta much less than 1. Zeta remains small even if a population of very small grains with power-law index as steep as approximately 5.5 is added. A population with even more small grains and/or fewer large grains could have a zeta similar to 1 and be detectable at present, but this seems unlikely. The echoes will move, but should remain accessible for many years and should be detected eventually.

Felten, James E.↗

New Applications for the Testing and Visualization of Wireless Networks

Traditional techniques for examining wireless networks use physical link characteristics such as Signal-to-Noise (SNR) ratios to assess the performance of wireless networks. Such measurements may not be reliable indicators of available bandwidth. This work describes two new software applications developed at NASA Glenn Research Center for the investigation of wireless networks. GPSIPerf combines measurements of Transmission Control Protocol (TCP) throughput with Global Positioning System (GPS) coordinates to give users a map of wireless bandwidth for outdoor environments where a wireless infrastructure has been deployed. GPSIPerfView combines the data provided by GPSIPerf with high-resolution digital elevation maps (DEM) to help users visualize and assess the impact of elevation features on wireless networks in a given sample area. These applications were used to examine TCP throughput in several wireless network configurations at desert field sites near Hanksville, Utah during May of 2004. Use of GPSIPerf and GPSIPerfView provides a geographically referenced picture of the extent and deterioration of TCP throughput in tested wireless network configurations. GPSIPerf results from field-testing in Utah suggest that it can be useful in assessing other wireless network architectures, and may be useful to future human-robotic exploration missions.

Griffin, Robert I.↗

Femtosecond two-photon-resonant parametric four-wave mixing detection of atomic hydrogen

Here, we demonstrate an ultrafast parametric four-wave mixing method for the collisional-quenching-free detection of atomic hydrogen. Two photons of 243 nm light resonantly excite the n = 1 to n = 2 transition of atomic hydrogen, and a third probe photon scatters from the electronic coherence to generate the parametric emission of a degenerate signal photon. Laser-induced photofragmentation fluorescence from water, also excited with the same 243 nm pulses, is used as a convenient method to visualize beam overlap in space and time. The femtosecond time resolution enables the suppression of unwanted nonresonant contributions to the signal and separation from resonant mixing in water molecules because of the significantly different coherence lifetimes. A folded BOXCARS phase-matching configuration yields a spatially isolated, laser-like, signal beam, amenable to measurements in highly luminous backgrounds. Measurements in an H 2 /CH 4 /air flame demonstrate quantitative agreement with simulated H-atom concentration profiles. A coherence decay time constant of 42 ps is recorded in the atmospheric pressure flame.

Kliewer, Christopher Jesse [Sandia National Labora↗

Vestibular Stochastic Resonance as a Method to Improve Balance Function: Optimization of Stimulus Characteristics

Stochastic resonance (SR) is a mechanism by which noise can assist and enhance the response of neural systems to relevant sensory signals. Application of imperceptible SR noise coupled with sensory input through the proprioceptive, visual, or vestibular sensory systems has been shown to improve motor function. Specifically, studies have shown that that vestibular electrical stimulation by imperceptible stochastic noise, when applied to normal young and elderly subjects, significantly improved their ocular stabilization reflexes in response to whole-body tilt as well as balance performance during postural disturbances. The goal of this study was to optimize the characteristics of the stochastic vestibular signals for balance performance during standing on an unstable surface. Subjects performed a standardized balance task of standing on a block of 10 cm thick medium density foam with their eyes closed for a total of 40 seconds. Stochastic electrical stimulation was applied to the vestibular system through electrodes placed over the mastoid process behind the ears during the last 20 seconds of the test period. A custom built constant current stimulator with subject isolation delivered the stimulus. Stimulation signals were generated with frequencies in the bandwidth of 1-2 Hz and 0.01-30 Hz. Amplitude of the signals were varied in the range of 0- +/-700 micro amperes with the RMS of the signal increased by 30 micro amperes for each 100 micro amperes increase in the current range. Balance performance was measured using a force plate under the foam block and inertial motion sensors placed on the torso and head segments. Preliminary results indicate that balance performance is improved in the range of 10-25% compared to no stimulation conditions. Subjects improved their performance consistently across the blocks of stimulation. Further the signal amplitude at which the performance was maximized was different in the two frequency ranges. Optimization of the frequency and amplitude of the signal characteristics of the stochastic noise signals on maximizing balance performance will have a significant impact in its development as a unique system to aid recovery of function in astronauts after long duration space flight or for people with balance disorders.

Mulavara, Ajitkumar↗