Search NASA⌕ Search

SEARCH · Search NASA

Results for “simulator motion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

CT Fluoroscopy-Guided Lung Biopsy with Novel Steerable Biopsy Canula: Ex-Vivo Evaluation in Ventilated Porcine Lung Explants

The purpose was to evaluate ex-vivo a prototype of a novel biopsy canula under CT fluoroscopy-guidance in ventilated porcine lung explants in respiratory motion simulations. Using an established chest phantom for porcine lung explants, n = 24 artificial lesions consisting of a fat-wax-Lipiodol mixture (approx. 70HU) were placed adjacent to sensible structures such as aorta, pericardium, diaphragm, bronchus and pulmonary artery. A piston pump connected to a reservoir beneath a flexible silicone reconstruction of a diaphragm simulated respiratory motion by rhythmic inflation and deflation of 1.5 L water. As biopsy device an 18-gauge prototype biopsy canula with a lancet-like, helically bended cutting edge was used. The artificial lesions were punctured under CT fluoroscopy-guidance (SOMATOM Sensation 64, Siemens, Erlangen, Germany; 30mAs/120 kV/5 mm slice thickness) implementing a dedicated protocol for CT fluoroscopy-guided lung biopsy. The mean-diameter of the artificial lesions was 8.3 {+-} 2.6 mm, and the mean-distance of the phantom wall to the lesions was 54.1 {+-} 13.5 mm. The mean-displacement of the lesions by respiratory motion was 14.1 {+-} 4.0 mm. The mean-duration of CT fluoroscopy was 9.6 {+-} 5.1 s. On a 4-point scale (1 = central; 2 = peripheral; 3 = marginal; 4 = off target), the mean-targeted precision was 1.9 {+-} 0.9. No misplacement of the biopsy canula affecting adjacent structures could be detected. The novel steerable biopsy canula proved to be efficient in the ex-vivo set-up. The chest phantom enabling respiratory motion and the steerable biopsy canula offer a feasible ex-vivo system for evaluating and training CT fluoroscopy-guided lung biopsy adapted to respiratory motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-CAMPUS-J-01: TG142 Complied Comprehensive Commissioning and Quality Assurance Procedure for Respiratory Gating

Purpose: To develop and establish a comprehensive gating commissioning and quality assurance procedure in compliance with TG142. Methods: Quality assurance tests on three Varian LINACs included beam output and energy constancy, calibration of surrogate, as well as phase and amplitude gating temporal accuracy. A diode array (MapCHECK 2) and film (Gafchromic EBT2) were used to measure the temporal accuracy of phase and amplitude gating windows. A motion simulation device (MotionSim) was used to simulate respiratory motion for both detectors. An end-to-end test was also performed on all three machines. The overall accuracy and uncertainty was analyzed and compared. Results: The end-to-end test using an anthropomorphic lung phantom (CIRS) results in an OSL dose difference reading within 5% (within measurement uncertainty) for both phase and amplitude gated treatment. Film results showed < 1% agreement between profiles for gated delivery and predicted dose. The diode array demonstrated an 80% passing rate for gamma criteria of 2%/0.2 mm, which results in a 111 msec temporal accuracy. However, the diode array is limited by its spatial resolution of measurements, due to its 7.07 mm diode spacing. Film provided higher measuring resolution, thus demonstrated a temporal accuracy of <100 msec. Conclusion: Results showed consistent respiratory gating stability and accuracy. MapCHECK 2 may not be sufficient for the temporal accuracy test in the respiratory gating treatment in order to meet the corresponding tolerance in TG142. One would need to decrease respiratory motion speed from the surrogate or tighten the gating window in order to be within tolerance of 100 msec temporal accuracy per TG-142. The end-to-end test offers insight to the overall accuracy and uncertainties with a gated protocol. Compared to static delivery, respiratory motion increases the overall uncertainty of treatment delivery from 3% to 5% dose difference.

60 APPLIED LIFE SCIENCES↗

Testing a satellite automatic nutation control system

Testing of a particular nutation control system for the synchronous meteorological satellite (SMS) is described. The test method and principles are applicable to nutation angle control for other satellites with similar requirements. During its ascent to synchronous orbit, a spacecraft like the SMS spins about its minimum-moment-of-inertia axis. An uncontrolled spacecraft in this state is unstable because torques due to fuel motion increase the nutation angle. However, the SMS is equipped with an automatic nutation control (ANC) system which will keep the nutation angle close to zero. Because correct operation of this system is critical to mission success, it was tested on an air-bearing table. The ANC system was mounted on the three-axis air-bearing table which was scaled to the SMS and equipped with appropriate sensors and thrusters. The table was spun up in an altitude chamber and nutation induced so that table motion simulated spacecraft motion. The ANC system was used to reduce the nutation angle. This dynamic test of the ANC system met all its objectives and provided confidence that the ANC system will control the SMS nutation angle.

Hrasiar, J. A.↗

Objective Motion Cueing Criteria Investigation Based on Three Flight Tasks

This paper intends to help establish fidelity criteria to accompany the simulator motion system diagnostic test specified by the International Civil Aviation Organization. Twelve air- line transport pilots flew three tasks in the NASA Vertical Motion Simulator under four different motion conditions. The experiment used three different hexapod motion configurations, each with a different tradeoff between motion filter gain and break frequency, and one large motion configuration that utilized as much of the simulator's motion space as possible. The motion condition significantly affected: 1) pilot motion fidelity ratings, and sink rate and lateral deviation at touchdown for the approach and landing task, 2) pilot motion fidelity ratings, roll deviations, maximum pitch rate, and number of stick shaker activations in the stall task, and 3) heading deviation after an engine failure in the takeoff task. Significant differences in pilot-vehicle performance were used to define initial objective motion cueing criteria boundaries. These initial fidelity boundaries show promise but need refinement.

pilot training↗

Simulation of Motion of H{sub 2} and D{sub 2} Molecules in Sextupole Magnets

We simulate the motion of hydrogen and deuterium molecules in the magnetic system of a setup intended for obtaining nuclear-spin-polarized molecules. Spatial separation of molecules with different magnetic moment projections by the spin filtration method in a nonuniform magnetic field is performed using superconducting sextupole magnets. Calculations are carried out for a magnetic field induction of 3.7 T at the poles and a nozzle temperature of 7 K. Simulation show that the ratio of polarized flux of hydrogen molecules to the detector to the total flux from the source nozzle is 2.3 × 10{sup –6}, nuclear polarization being close to 100%. Calculations performed for deuterium reveal that this ratio is 7 times smaller due to the smallness of the magnetic moment relative to hydrogen molecules. Trajectories of molecules in the magnetic system and their spatial distribution are represented graphically. Mathematical aspects of the algorithm of the computer program developed for this purpose are considered.

74 ATOMIC AND MOLECULAR PHYSICS↗

Effects of Different Heave Motion Components on Pilot Pitch Control Behavior

The study described in this paper had two objectives. The first objective was to investigate if a different weighting of heave motion components decomposed at the center of gravity, allowing for a higher fidelity of individual components, would result in pilot manual pitch control behavior and performance closer to that observed with full aircraft motion. The second objective was to investigate if decomposing the heave components at the aircraft's instantaneous center of rotation rather than at the center of gravity could result in additional improvements in heave motion fidelity. Twenty-one general aviation pilots performed a pitch attitude control task in an experiment conducted on the Vertical Motion Simulator at NASA Ames under different hexapod motion conditions. The large motion capability of the Vertical Motion Simulator also allowed for a full aircraft motion condition, which served as a baseline. The controlled dynamics were of a transport category aircraft trimmed close to the stall point. When the ratio of center of gravity pitch heave to center of gravity heave increased in the hexapod motion conditions, pilot manual control behavior and performance became increasingly more similar to what is observed with full aircraft motion. Pilot visual and motion gains significantly increased, while the visual lead time constant decreased. The pilot visual and motion time delays remained approximately constant and decreased, respectively. The neuromuscular damping and frequency both decreased, with their values more similar to what is observed with real aircraft motion when there was an equal weighting of the heave of the center of gravity and heave due to rotations about the center of gravity. In terms of open- loop performance, the disturbance and target crossover frequency increased and decreased, respectively, and their corresponding phase margins remained constant and increased, respectively. The decomposition point of the heave components only had limited effects on pilot manual control behavior and performance.

manual control↗

Feasibility of the LAMMPS SPH Package for Simulating Bubble Motion in Vibrating Containers

The Smoothed Particle Hydrodynamics (SPH) package within LAMMPS is explored as a possible tool for simulating the motion of bubbles in a vibrating liquid-filled container. As an initial test case, the unphysical but computationally less intense situation of a two-dimensional single bubble rising in a quiescent liquid under the influence of gravity is considered herein. Although physically plausible behavior was obtained under certain conditions, this behavior depends strongly on the system parameters. Moreover, the large density ratio between the liquid and bubble requires extremely small timesteps, which make the simulations undesirably computationally expensive. Ultimately, it was determined that this method is not feasible for providing quantitatively accurate results for the desired application.

42 ENGINEERING↗

Motion-base simulator results of advanced supersonic transport handling qualities with active controls

Handling qualities of the unaugmented advanced supersonic transport (AST) are deficient in the low-speed, landing approach regime. Consequently, improvement in handling with active control augmentation systems has been achieved using implicit model-following techniques. Extensive fixed-based simulator evaluations were used to validate these systems prior to tests with full motion and visual capabilities on a six-axis motion-base simulator (MBS). These tests compared the handling qualities of the unaugmented AST with several augmented configurations to ascertain the effectiveness of these systems. Cooper-Harper ratings, tracking errors, and control activity data from the MBS tests have been analyzed statistically. The results show the fully augmented AST handling qualities have been improved to an acceptable level.

Feather, J. B.↗

Illusory self motion and simulator sickness

Presented here is a discussion of simulator sickness (with applications to motion sickness and space sickness) based on the notion of senses as perceptual systems, and the sensory conflict theory. Most forms of the sensory conflict theory unnecessarily propose the existence of a neural store. The neural store is thought to consist of a record of previous perceptual experiences against which currently experienced patterns of stimulation are compared. The authors seek to establish that in its most parsimonious form the sensory conflict theory does not require a construct such as the neural store. In its simpler form, the sensory conflict theory complements and extends Gibson's view of the senses as perceptual systems.

Hettinger, Lawrence J.↗

Transfer-of-Training Research at NASA Ames Research Center

In this presentation, I will first give an overview of some of the research being performed at the Human Systems Integration Division of NASAs Ames Research Center. In the second part of the presentation, I will discuss two studies that investigate the effects of simulator motion on pilot transfer of training. In a study funded by the Federal Aviation Administration, task performance is used to investigate the effects of motion on the training of 4 challenging tasks in a transport category aircraft. In addition, the effectiveness of recently proposed objective motion cueing criteria for training simulators are evaluated. The second study, part of the NASA Aeronautics Research Program, focuses on optimizing simulator motion for maximum transfer of stall recovery training and utilizes a cybernetic approach to measure transfer of training.

Zaal, Peter M. T.↗

Motion-Base Simulator Evaluation of an Aircraft Using an External Vision System

Twelve air transport-rated pilots participated as subjects in a motion-base simulation experiment to evaluate the use of eXternal Vision Systems (XVS) as enabling technologies for future supersonic aircraft without forward facing windows. Three head-up flight display concepts were evaluated -a monochromatic, collimated Head-up Display (HUD) and a color, non-collimated XVS display with a field-of-view (FOV) equal to and also, one significantly larger than the collimated HUD. Approach, landing, departure, and surface operations were conducted. Additionally, the apparent angle-of-attack (AOA) was varied (high/low) to investigate the vertical field-of-view display requirements and peripheral, side window visibility was experimentally varied. The data showed that lateral approach tracking performance and lateral landing position were excellent regardless of AOA, display FOV, display collimation or whether peripheral cues were present. However, the data showed glide slope approach tracking appears to be affected by display size (i.e., FOV) and collimation. The monochrome, collimated HUD and color, uncollimated XVS with Full FOV display had (statistically equivalent) glide path performance improvements over the XVS with HUD FOV display. Approach path performance results indicated that collimation may not be a requirement for an XVS display if the XVS display is large enough and employs color. Subjective assessments of mental workload and situation awareness also indicated that an uncollimated XVS display may be feasible. Motion cueing appears to have improved localizer tracking and touchdown sink rate across all displays.

Kramer, Lynda J.↗

Modelling atmospheric turbulence for a motion-based simulator

The background information in establishing several proposed atmospheric turbulence models for use on motion based aircraft simulators was documented. A specific model was proposed which, in addition to varying turbulence intensity (rms velocity), varies the atmospheric turbulence scale length to achieve compatibility with real atmospheric turbulence. With a suitable combination of scale length and intensity distribution, the model will simulate various atmospheric conditions characterized by altitude, stability, and terrain. The model is mechanized to be included in a flight simulator experiment in order to determine to what extent the pilots are sensitive to changes in atmospheric conditions and the realism of the model. The following topics were covered: literature survey, presently used techniques, proposed model, and simulation details.

Jacobson, I. D.↗

ANOPP/VMS HSCT ground contour system

This viewgraph shows the integration of the Visual Motion Simulator with ANOPP. ANOPP is an acronym for the Aircraft NOise Prediction Program. It is a computer code consisting of dedicated noise prediction modules for jet, propeller, and rotor powered aircraft along with flight support and noise propagation modules, all executed under the control of an executive system. The Visual Motion Simulator (VMS) is a ground based motion simulator with six degrees of freedom. The transport-type cockpit is equipped with conventional flight and engine-thrust controls and with flight instrument displays. Control forces on the wheel, column, and rudder pedals are provided by a hydraulic system coupled with an analog computer. The simulator provides variable-feel characteristics of stiffness, damping, coulomb friction, breakout forces, and inertia. The VMS provides a wide range of realistic flight trajectories necessary for computing accurate ground contours. The NASA VMS will be discussed in detail later in this presentation. An equally important part of the system for both ANOPP and VMS is the engine performance. This will also be discussed in the presentation.

Rawls, John, Jr.↗

SU-E-J-60: Evaluation of Temporal Lag in Radiotherapy Gating for Tumor Motion Trajectories

Purpose: Evaluating timing differences between LINAC beam ON/OFF and the estimation of tumor positioning using gating systems is essential for establishing confidence when treating with gating during radiotherapy, and is an annual requirement of TG-142. Temporal discrepancies between the trajectories of external marker surrogates and beam delivery may vary depending upon the type of external marker motion, which is quantified in this work for several trajectories. Methods: A precise robotic 3D motion stage performed several trajectories typically used for gating phantoms, including sinusoidal and Lujan-type motion; a commercial respiratory motion simulator was also employed. The true motions were monitored using variable resistors. The beam ON/OFF was controlled separately by two RPM (Varian) systems, an integrated version delivered by a Varian Truebeam LINAC and version 1.6 delivered by a Varian Trilogy, and measured using a diode. The resistor and diode signals were read by a multichannel digital oscilloscope, and timing differences between beam ON/OFF as measured by the diode and the phantom motion were determined using a peak detection algorithm. Results: Timing differences between beam ON/OFF and 3D stage motion peaks (diode—true motion timing) were computed to be 79.4 & 57.7ms for sinusoidal motion and 109.1 & 63.6ms for Lujan-type motion on the Truebeam LINAC, for beam ON and OFF, respectively. Timing differences for the Trilogy LINAC were 34.4 & 55.2ms for the sinusoidal motion and 29.0 & 26.3ms for the Lujan-type motion, for beam ON and OFF, respectively. With the commercial motion simulator, the timing differences were found to be −9ms and −78ms for beam ON/OFF, respectively, with the Truebeam, and −97.6ms and −60.9ms for beam ON/OFF, respectively, with the Trilogy. Conclusion: Setup-dependent temporal lags were found using this methodology. These discrepancies have the potential to influence quality assurance on gating systems and ultimately the treatment dose during radiotherapy. NIH National Institute of Biomedical Imaging and Bioengineering grant T32 EB002103-21.

60 APPLIED LIFE SCIENCES↗

Sensory perception

The effect of motion on the ability of men to perform a variety of control actions was investigated. Special attention was given to experimental and analytical studies of the dynamic characteristics of the otoliths and semicircular canals using a two axis angular motion simulator and a one axis linear motion simulator.

Source record↗

Reducing Frequency Bias of Fourier Neural Operators in 3D Seismic Wavefield Simulations Through Multistage Training

The recent development of neural operator (NeurOp) learning for solutions to the elastic wave equation shows promising results and provides the basis for fast large-scale simulations for different seismological applications. In this article, we use the Fourier neural operator (FNO) model to directly solve the 3D Helmholtz wave equation for fast seismic ground-motion simulations on different frequencies and show the frequency bias of the FNO model, that is, it learns the lower frequencies better comparing to the higher frequencies. To reduce the frequency bias, we adopt the multistage FNO training, that is, after training a stage 1 FNO model for estimating the ground motion, we use a second FNO model as the stage 2 to learn from the residual, which greatly reduced the errors on the higher frequencies. By adopting this multistage training, the FNO models show reduced biases on higher frequencies, which enhanced the overall results of the ground-motion simulations. Thus the multistage training FNO improves the accuracy and realism of the ground-motion simulations.

earthquakes↗

Evaluating Sensory Augmentation as A Non-Pharmaceutical Tool to Mitigate Motion Sickness and Enhance Sensorimotor Task Performance: A Pilot Study Using Simulated Capsule Wave Motion

Wave motion during capsule recovery operations can result in motion sickness and performance decrements exacerbating reentry sickness following long duration spaceflight. The purpose of this pilot study was (1) to validate a capsule wave motion simulation as a platform to evaluate motion sickness countermeasures and (2) to evaluate a sensory augmentation belt providing vibrotactile feedback of gravitational upright. Ten healthy subjects ages 38.0 ± 10.1 (6M|4F) were exposed to complex wave motions on a six degree-of-freedom platform that included pitch, roll, and heave at provocative stimulus frequencies (0.1-0.25 Hz) while seated in an illuminated cabin deprived of external visual cues. Subjects reported acute symptoms for up to three consecutive 15 min trials or until they reached a motion sickness endpoint of 8 pts on the Pensacola Diagnostic Index (PDI). Five subjects were randomly assigned to the Sensory Augmentation (SA) group while the other five served as controls (CN group). Based on a Motion Sickness Susceptibility Questionnaire, the two groups had similar motion sickness histories (susceptibility percentile ranking of CN group = 27.5 ± 63.6 in the CN group versus 27.5 ± 37.0 in the SA group, median ± IQR). The vibrotactile feedback consisted of a single array of 8 electromechanical tactors positioned around the torso on an adjustable belt (Engineering Acoustics, Inc) that utilized an integrated inertial measurement unit (IMU) to indicate the direction of upright (e.g., subject’s back tactor on during forward tilt). During each wave motion trial subjects performed a battery of four different tasks: tracking Earth vertical using a joystick with and without a secondary task (Paced Auditory Serial Addition Test), an eye-hand target acquisition task on a cabin-fixed tablet, and the psychomotor vigilance test (PVT). All ten subjects reported varying levels of motion sickness with 6 of 10 reaching a symptom endpoint. Interestingly, subjects anecdotally reported that engagement in the joystick tracking task was less provocative than tasks involving the cabin-fixed tablet or periods of no activity. Sensory augmentation appeared to delay symptom onset, with 2 of 5 subjects reaching an endpoint within the first 15 min trial in the CN group versus none in the SA group (PDI after 15 min = 6.0 ± 2.5 in the CN group versus 3.4 ± 2.5 in the SA group, mean ±std). Sensory augmentation also improved performance on the joystick tracking task at lower stimulus frequencies (0.1 Hz in roll and 0.2 Hz in pitch). Both CN and SA groups maintained a consistent level of performance on the eye-hand target acquisition and PVT throughout the baseline (no motion) and wave motion periods. Our results validated that the simulated capsule wave motion paradigm provides an effective motion sickness stressor. This paradigm is currently being used to investigate the efficacy of intranasal scopolamine to mitigate motion sickness. Sensory augmentation using vibrotactile feedback appears to improve spatial awareness and delay symptom onset during complex passive motion. One advantage of this portable belt design is that it incorporates all tactor drive and IMU circuitry and therefore could continue to be worn by crewmembers and serve as a balance aid during egress and ambulation with recovery operations.

A M Bollinger↗

Comparison of Flight Simulators Based on Human Motion Perception Metrics

In flight simulation, motion filters are used to transform aircraft motion into simulator motion. When looking for the best match between visual and inertial amplitude in a simulator, researchers have found that there is a range of inertial amplitudes, rather than a single inertial value, that is perceived by subjects as optimal. This zone, hereafter referred to as the optimal zone, seems to correlate to the perceptual coherence zones measured in flight simulators. However, no studies were found in which these two zones were compared. This study investigates the relation between the optimal and the coherence zone measurements within and between different simulators. Results show that for the sway axis, the optimal zone lies within the lower part of the coherence zone. In addition, it was found that, whereas the width of the coherence zone depends on the visual amplitude and frequency, the width of the optimal zone remains constant.

Valente Pais, Ana R.↗