Search NASA⌕ Search

SEARCH · Search NASA

Results for “slice sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Using the application visualization system to view HALOE three-dimensional satellite data

The Application Visualization System (AVS) is used to view a three-dimensional data field containing the volume mixing ratios of a chemical species in the middle atmosphere obtained by the Halogen Occultation Experiment (HALOE) aboard the Upper Atmosphere Research Satellite (UARS). Since launch in September 1991, HALOE has been collecting data on approximately 30 sunrise/sunset events in two narrow latitude bands each day. The vertical volume mixing ratio profiles are retrieved for eight species for each event. The accumulated data for approximately 30 days cover most of the globe (limited by sunlit latitudes), and this monthly data block can be described as the volume mixing ratio of a specific species in the atmosphere as a function of latitude, longitude, and height. The data were remapped using linear interpolation for pressure levels and Gaussian weighted binning from sampling locations to a three-dimensional grid. An AVS network is constructed that allows for viewing the three-dimensional field with rendered slices at constant latitudes, longitudes or pressure levels. Discussions are given on the advantages and some disadvantages learned about from experiences applying AVS to visualize HALOE three dimensional data.

Luo, Mingzhao↗

Global Free-tropospheric NO2 Abundances Derived Using a Cloud Slicing Technique from AURA OMI

We derive free-tropospheric NO2 volume mixing ratios (VMRs) by applying a cloud-slicing technique to data from the Ozone Monitoring Instrument (OMI) on the Aura satellite. In the cloud-slicing approach, the slope of the above-cloud NO2 column versus the cloud scene pressure is proportional to the NO2 VMR. In this work, we use a sample of nearby OMI pixel data from a single orbit for the linear fit. The OMI data include cloud scene pressures from the rotational-Raman algorithm and above-cloud NO2 vertical column density (VCD) (defined as the NO2 column from the cloud scene pressure to the top of the atmosphere) from a differential optical absorption spectroscopy (DOAS) algorithm. We compare OMI-derived NO2 VMRs with in situ aircraft profiles measured during the NASA Intercontinental Chemical Transport Experiment Phase B (INTEX-B) campaign in 2006. The agreement is generally within the estimated uncertainties when appropriate data screening is applied. We then derive a global seasonal climatology of free-tropospheric NO2 VMR in cloudy conditions. Enhanced NO2 in the free troposphere commonly appears near polluted urban locations where NO2 produced in the boundary layer may be transported vertically out of the boundary layer and then horizontally away from the source. Signatures of lightning NO2 are also shown throughout low and middle latitude regions in summer months. A profile analysis of our cloud-slicing data indicates signatures of lightning-generated NO2 in the upper troposphere. Comparison of the climatology with simulations from the global modeling initiative (GMI) for cloudy conditions (cloud optical depth less than10) shows similarities in the spatial patterns of continental pollution outflow. However, there are also some differences in the seasonal variation of free-tropospheric NO2 VMRs near highly populated regions and in areas affected by lightning-generated NOx.

NO2↗

Global Free Tropospheric NO2 Abundances Derived Using a Cloud Slicing Technique Applied to Satellite Observations from the Aura Ozone Monitoring Instrument (OMI)

We derive free-tropospheric NO2 volume mixing ratios (VMRs) and stratospheric column amounts of NO2 by applying a cloud slicing technique to data from the Ozone Monitoring Instrument (OMI) on the Aura satellite. In the cloud-slicing approach, the slope of the above-cloud NO2 column versus the cloud scene pressure is proportional to the NO2 VMR. In this work, we use a sample of nearby OMI pixel data from a single orbit for the linear fit. The OMI data include cloud scene pressures from the rotational-Raman algorithm and above-cloud NO2 vertical column density (VCD) (defined as the NO2 column from the cloud scene pressure to the top-of-the-atmosphere) from a differential optical absorption spectroscopy (DOAS) algorithm. Estimates of stratospheric column NO2 are obtained by extrapolating the linear fits to the tropopause. We compare OMI-derived NO2 VMRs with in situ aircraft profiles measured during the NASA Intercontinental Chemical Transport Experiment Phase B (INTEX-B) campaign in 2006. The agreement is generally within the estimated uncertainties when appropriate data screening is applied. We then derive a global seasonal climatology of free-tropospheric NO2 VMR in cloudy conditions. Enhanced NO2 in the free troposphere commonly appears near polluted urban locations where NO2 produced in the boundary layer may be transported vertically out of the boundary layer and then horizontally away from the source. Signatures of lightning NO2 are also shown throughout low and middle latitude regions in summer months. A profile analysis of our cloud slicing data indicates signatures of uplifted and transported anthropogenic NO2 in the middle troposphere as well as lightning-generated NO2 in the upper troposphere. Comparison of the climatology with simulations from the Global Modeling Initiative (GMI) for cloudy conditions (cloud optical thicknesses > 10) shows similarities in the spatial patterns of continental pollution outflow. However, there are also some differences in the seasonal variation of free-tropospheric NO2 VMRs near highly populated regions and in areas affected by lightning-generated NOx. Stratospheric column NO2 obtained from cloud slicing agrees well with other independently-generated estimates, providing further confidence in the free-tropospheric results.

NO2↗

Time-Domain Terahertz Computed Axial Tomography NDE System

NASA has identified the need for advanced non-destructive evaluation (NDE) methods to characterize aging and durability in aircraft materials to improve the safety of the nation's airline fleet. 3D THz tomography can play a major role in detection and characterization of flaws and degradation in aircraft materials, including Kevlar-based composites and Kevlar and Zylon fabric covers for soft-shell fan containment where aging and durability issues are critical. A prototype computed tomography (CT) time-domain (TD) THz imaging system has been used to generate 3D images of several test objects including a TUFI tile (a thermal protection system tile used on the Space Shuttle and possibly the Orion or similar capsules). This TUFI tile had simulated impact damage that was located and the depth of damage determined. The CT motion control gan try was designed and constructed, and then integrated with a T-Ray 4000 control unit and motion controller to create a complete CT TD-THz imaging system prototype. A data collection software script was developed that takes multiple z-axis slices in sequence and saves the data for batch processing. The data collection software was integrated with the ability to batch process the slice data with the CT TD-THz image reconstruction software. The time required to take a single CT slice was decreased from six minutes to approximately one minute by replacing the 320 ps, 100-Hz waveform acquisition system with an 80 ps, 1,000-Hz waveform acquisition system. The TD-THZ computed tomography system was built from pre-existing commercial off-the-shelf subsystems. A CT motion control gantry was constructed from COTS components that can handle larger samples. The motion control gantry allows inspection of sample sizes of up to approximately one cubic foot (.0.03 cubic meters). The system reduced to practice a CT-TDTHz system incorporating a COTS 80- ps/l-kHz waveform scanner. The incorporation of this scanner in the system allows acquisition of 3D slice data with better signal-to-noise using a COTS scanner rather than the gchirped h scanner. The system also reduced to practice a prototype for commercial CT systems for insulating materials where safety concerns cannot accommodate x-ray. A software script was written to automate the COTS software to collect and process TD-THz CT data.

Zimdars, David↗

MULTI-SCALE MORPHOLOGICAL ANALYSIS OF SDSS DR5 SURVEY USING THE METRIC SPACE TECHNIQUE

Following the novel development and adaptation of the Metric Space Technique (MST), a multi-scale morphological analysis of the Sloan Digital Sky Survey (SDSS) Data Release 5 (DR5) was performed. The technique was adapted to perform a space-scale morphological analysis by filtering the galaxy point distributions with a smoothing Gaussian function, thus giving quantitative structural information on all size scales between 5 and 250 Mpc. The analysis was performed on a dozen slices of a volume of space containing many newly measured galaxies from the SDSS DR5 survey. Using the MST, observational data were compared to galaxy samples taken from N-body simulations with current best estimates of cosmological parameters and from random catalogs. By using the maximal ranking method among MST output functions, we also develop a way to quantify the overall similarity of the observed samples with the simulated samples.

79 ASTRONOMY AND ASTROPHYSICS↗

Investigating the Depth of Penetration of Radionuclides in Concrete - 16292

This paper focuses on some chemical and structural aspects for mature concrete structural substrate that functions as a barrier to radioactive material migration. Exposure to radioactive material may be a consequence of surface contact, such as resulting from exposure by spills or leaks. In properly-prepared waste storage areas, undamaged paint and sealant helps to protect the structural cement. However, damaged surfaces, cracks, and relatively porous slab seams can offer a preferred migration pathway for spilled contaminates, including radionuclides. The cost of remediation of concrete structures is directly related to the amount of concrete that must be removed and subsequently disposed. A carefully implemented investigative plan can be utilized to determine how much concrete must be removed and the approximate level of volumetric radiological contamination can be used to estimate disposal costs. Normal concrete pore solution is saturated with calcium hydroxide and also contains sodium and potassium hydroxide; the pH is typically 13 to 14. Contaminants (such as uranium) that hydrolyze in alkaline media that form precipitant phases and tend to deposit at the near-surface. However, more soluble contaminants, such as Cs-137 (as Cs{sup +}) and Tc-99 (as the pertechnetate anion TcO{sub 4}{sup -}) diffuse more rapidly (and deeply) into the porous substrate. Profiling the migration of the water-soluble radionuclides into a cure (hardened) cement surface is a challenge, since water-cooled saws, borers and similar implements are often used to excise and/or slice the core. Alternately, dry mechanical fracturing for excavation of cement may introduce the possibility of material cross-contamination and uncertainty for the average sampling depth for the sample collection event, potentially yielding non-representative samples, and may preclude determination of crack formation that may have been present in the native (non-fractured) substrate. Structural concrete is comprised of cement and pozzolan paste, relatively impervious aggregate (typically stone and/or sand), and rebar (iron reinforcement). Near-surface aggregate may act as a hydrolytic barrier, causing contaminants leached into the pore water to by-pass the impervious grains, causing deeper-than expected penetration, especially if there are grain boundary cracks also present to facilitate migration. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of a remote laser-induced breakdown spectroscopy system for investigation of calcified tissue samples

The development of a remote laser-induced breakdown spectroscopy (LIBS) setup with an off-axis Newtonian collection optics, Galilean-based focusing telescope, and a 532 nm flattop laser beam source is presented. The device was tested at a 6 m distance on a slice of bone to simulate its possible use in the field, e.g., during archaeological excavations. It is shown that this setup is sufficiently sensitive to both major (P, Mg) and minor elements (Na, Zn, Sr). The measured quantities of Mg, Zn, and Sr correspond to the values obtained by reference laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) measurements within an approximately 20% range of uncertainty. A single point calibration was performed by use of a bone meal standard . The radial element distribution is almost invariable by use of LA-ICP-MS, whereas the LIBS measurement showed a strong dependence on the sample porosity. Based on these results, this remote LIBS setup with a relatively large (350 mm) collecting mirror is capable of semiquantitative analysis at the level of units of mg kg{sup -1}.

74 ATOMIC AND MOLECULAR PHYSICS↗

The clustering of galaxies in the completed SDSS-III Baryon Oscillation Spectroscopic Survey: cosmological analysis of the DR12 galaxy sample

Here we present cosmological results from the final galaxy clustering data set of the Baryon Oscillation Spectroscopic Survey, part of the Sloan Digital Sky Survey III. Our combined galaxy sample comprises 1.2 million massive galaxies over an effective area of 9329 deg 2 and volume of 18.7 Gpc 3 , divided into three partially overlapping redshift slices centred at effective redshifts 0.38, 0.51 and 0.61. We measure the angular diameter distance DM and Hubble parameter H from the baryon acoustic oscillation (BAO) method, in combination with a cosmic microwave background prior on the sound horizon scale, after applying reconstruction to reduce non-linear effects on the BAO feature. Using the anisotropic clustering of the pre-reconstruction density field, we measure the product DMH from the Alcock–Paczynski (AP) effect and the growth of structure, quantified by fσ8(z), from redshift-space distortions (RSD). We combine individual measurements presented in seven companion papers into a set of consensus values and likelihoods, obtaining constraints that are tighter and more robust than those from any one method; in particular, the AP measurement from sub-BAO scales sharpens constraints from post-reconstruction BAOs by breaking degeneracy between DM and H. Combined with Planck 2016 cosmic microwave background measurements, our distance scale measurements simultaneously imply curvature ΩK = 0.0003 ± 0.0026 and a dark energy equation-of-state parameter w = -1.01 ± 0.06, in strong affirmation of the spatially flat cold dark matter (CDM) model with a cosmological constant (ΛCDM). Our RSD measurements of fσ8, at 6 per cent precision, are similarly consistent with this model. When combined with supernova Ia data, we find H0 = 67.3 ± 1.0 km s -1 Mpc -1 even for our most general dark energy model, in tension with some direct measurements. Adding extra relativistic species as a degree of freedom loosens the constraint only slightly, to H0 = 67.8 ± 1.2km s -1 Mpc -1 . Assuming flat ΛCDM, we find Ωm = 0.310 ± 0.005 and H0 = 67.6 ± 0.5 km s -1 Mpc -1 , and we find a 95 per cent upper limit of 0.16 eV c -2 on the neutrino mass sum.

79 ASTRONOMY AND ASTROPHYSICS↗

Sparse coding of pathology slides compared to transfer learning with deep neural networks

Background Histopathology images of tumor biopsies present unique challenges for applying machine learning to the diagnosis and treatment of cancer. The pathology slides are high resolution, often exceeding 1GB, have non-uniform dimensions, and often contain multiple tissue slices of varying sizes surrounded by large empty regions. The locations of abnormal or cancerous cells, which may constitute a small portion of any given tissue sample, are not annotated. Cancer image datasets are also extremely imbalanced, with most slides being associated with relatively common cancers. Since deep representations trained on natural photographs are unlikely to be optimal for classifying pathology slide images, which have different spectral ranges and spatial structure, we here describe an approach for learning features and inferring representations of cancer pathology slides based on sparse coding. Results We show that conventional transfer learning using a state-of-the-art deep learning architecture pre-trained on ImageNet (RESNET) and fine tuned for a binary tumor/no-tumor classification task achieved between 85% and 86% accuracy. However, when all layers up to the last convolutional layer in RESNET are replaced with a single feature map inferred via a sparse coding using a dictionary optimized for sparse reconstruction of unlabeled pathology slides, classification performance improves to over 93%, corresponding to a 54% error reduction. Conclusions We conclude that a feature dictionary optimized for biomedical imagery may in general support better classification performance than does conventional transfer learning using a dictionary pre-trained on natural images.

59 BASIC BIOLOGICAL SCIENCES↗

The effect of gravity level on the average primary dendritic spacing of a directionally solidified superalloy

The effect of alternating low (0.01 g) and high (1.8 g) gravity force on the primary spacings in the dendrite structure in a directionally solidified Ni-based superalloy (PWA 1480, containing 5 pct Co, 10 pct Cr, 4 pct W, 12 pct Ta, 5 pct Al, 1.5 pct Ti, and the balance Ni) was investigated using samples solidified in a directional solidification furnace aboard the NASA KC-135 aircraft that made a series of low-g parabolas. The cross-section slices for each growth rate were polished and etched with Kallings II, and the primary dendritic arm spacings were measured using the method of Jacobi and Schwerdtfeger (1976). The arm spacings were found to fluctuate with gravity force, increasing as the gravity level decreased, and growing finer as gravity increased.

Mccay, M. H.↗

CT reconstruction techniques for improved accuracy of lung CT airway measurement

Purpose: To determine the impact of constrained reconstruction techniques on quantitative CT (qCT) of the lung parenchyma and airways for low x-ray radiation dose. Methods: Measurement of small airways with qCT remains a challenge, especially for low x-ray dose protocols. Images of the COPDGene quality assurance phantom (CTP698, The Phantom Laboratory, Salem, NY) were obtained using a GE discovery CT750 HD scanner for helical scans at x-ray radiation dose-equivalents ranging from 1 to 4.12 mSv (12–100 mA s current–time product). Other parameters were 40 mm collimation, 0.984 pitch, 0.5 s rotation, and 0.625 mm thickness. The phantom was sandwiched between 7.5 cm thick water attenuating phantoms for a total length of 20 cm to better simulate the scatter conditions of patient scans. Image data sets were reconstructed using STANDARD (STD), DETAIL, BONE, and EDGE algorithms for filtered back projection (FBP), 100% adaptive statistical iterative reconstruction (ASIR), and Veo reconstructions. Reduced (half) display field of view (DFOV) was used to increase sampling across airway phantom structures. Inner diameter (ID), wall area percent (WA%), and wall thickness (WT) measurements of eight airway mimicking tubes in the phantom, including a 2.5 mm ID (42.6 WA%, 0.4 mm WT), 3 mm ID (49.0 WA%, 0.6 mm WT), and 6 mm ID (49.0 WA%, 1.2 mm WT) were performed with Airway Inspector (Surgical Planning Laboratory, Brigham and Women’s Hospital, Boston, MA) using the phase congruency edge detection method. The average of individual measures at five central slices of the phantom was taken to reduce measurement error. Results: WA% measures were greatly overestimated while IDs were underestimated for the smaller airways, especially for reconstructions at full DFOV (36 cm) using the STD kernel, due to poor sampling and spatial resolution (0.7 mm pixel size). Despite low radiation dose, the ID of the 6 mm ID airway was consistently measured accurately for all methods other than STD FBP. Veo reconstructions showed slight improvement over STD FBP reconstructions (4%–9% increase in accuracy). The most improved ID and WA% measures were for the smaller airways, especially for low dose scans reconstructed at half DFOV (18 cm) with the EDGE algorithm in combination with 100% ASIR to mitigate noise. Using the BONE + ASIR at half BONE technique, measures improved by a factor of 2 over STD FBP even at a quarter of the x-ray dose. Conclusions: The flexibility of ASIR in combination with higher frequency algorithms, such as BONE, provided the greatest accuracy for conventional and low x-ray dose relative to FBP. Veo provided more modest improvement in qCT measures, likely due to its compatibility only with the smoother STD kernel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-362: Quantification and Modelling of the Ionization Chamber Simulation Effective Points On Monaco Treatment Planning System

Purpose: Because of statistical noise in Monte Carlo dose calculations, effective point doses may not be accurate. Volume spheres are useful for evaluating dose in Monte Carlo plans, which have an inherent statistical uncertainty.We use a user-defined sphere volume instead of a point, take sphere sampling around effective point make the dose statistics to decrease the stochastic errors. Methods: Direct dose measurements were made using a 0.125cc Semiflex ion chamber (IC) 31010 isocentrically placed in the center of a homogeneous Cylindric sliced RW3 phantom (PTW, Germany).In the scanned CT phantom series the sensitive volume length of the IC (6.5mm) were delineated and defined the isocenter as the simulation effective points. All beams were simulated in Monaco in accordance to the measured model. In our simulation using 2mm voxels calculation grid spacing and choose calculate dose to medium and request the relative standard deviation ≤0.5%. Taking three different assigned IC over densities (air electron density(ED) as 0.01g/cm3 default CT scanned ED and Esophageal lumen ED 0.21g/cm3) were tested at different sampling sphere radius (2.5, 2, 1.5 and 1 mm) statistics dose were compared with the measured does. Results: The results show that in the Monaco TPS for the IC using Esophageal lumen ED 0.21g/cm3 and sampling sphere radius 1.5mm the statistical value is the best accordance with the measured value, the absolute average percentage deviation is 0.49%. And when the IC using air electron density(ED) as 0.01g/cm3 and default CT scanned EDthe recommented statistical sampling sphere radius is 2.5mm, the percentage deviation are 0.61% and 0.70%, respectivly. Conclusion: In Monaco treatment planning system for the ionization chamber 31010 recommend air cavity using ED 0.21g/cm3 and sampling 1.5mm sphere volume instead of a point dose to decrease the stochastic errors. Funding Support No.C201505006.

60 APPLIED LIFE SCIENCES↗

EBSD and TEM Characterization of High Burn-up Mixed Oxide Fuel

Understanding and studying the irradiation behavior of high burn-up oxide fuel is critical to licensing of future fast breeder reactors. Advancements in experimental techniques and equipment are allowing for new insights into previously irradiated samples. In this work dual column focused ion beam (FIB)/scanning electron microscope (SEM) was utilized to prepared transmission electron microscope samples from mixed oxide fuel with a burn-up of 6.7% FIMA. Utilizing the FIB/SEM for preparation resulted in samples with a dose rate of <0.5 mRem/h compared to approximately 1.1 R/h for a traditionally prepared TEM sample. The TEM analysis showed that the sample taken from the cooler rim region of the fuel pellet had approximately 2.5x higher dislocation density than that of the sample taken from the mid-radius due to the lower irradiation temperature of the rim. The dual column FIB/SEM was additionally used to prepared and serially slice approximately 25 um cubes. High quality electron back scatter diffraction (EBSD) were collected from the face at each step, showing, for the first time, the ability to obtain EBSD data from high activity irradiated fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A novel cosmic filament catalogue from SDSS data

Here, in this work, we present a new catalogue of cosmic filaments obtained from the latest Sloan Digital Sky Survey (SDSS) public data. In order to detect filaments, we implement a version of the Subspace-Constrained Mean-Shift algorithm that is boosted by machine learning techniques. This allows us to detect cosmic filaments as one-dimensional maxima in the galaxy density distribution. Our filament catalogue uses the cosmological sample of SDSS, including Data Release 16, and therefore inherits its sky footprint (aside from small border effects) and redshift coverage. In particular, this means that, taking advantage of the quasar sample, our filament reconstruction covers redshifts up to z = 2.2, making it one of the deepest filament reconstructions to our knowledge. We follow a tomographic approach and slice the galaxy data in 269 shells at different redshift. The reconstruction algorithm is applied to 2D spherical maps. The catalogue provides the position and uncertainty of each detection for each redshift slice. The quality of our detections, which we assess with several metrics, show improvement with respect to previous public catalogues obtained with similar methods. We also detect a highly significant correlation between our filament catalogue and galaxy cluster catalogues built from microwave observations of the Planck Satellite and the Atacama Cosmology Telescope.

79 ASTRONOMY AND ASTROPHYSICS↗

WHOLE CELL TOMOGRAPHY/MOLECULAR BIOLOGY/STRUCTURAL BIOLOGY: Affordable x-ray microscopy with nanoscale resolution

Biological research spans 10 orders of magnitude from angstroms to meters. While electron microscopy can reveal structural details at most of these spatial length scales, transmission electron tomography only reliably reconstructs three-dimensional (3-D) volumes of cellular material with a spatial resolution between 1-5 nm from samples less than 500 nm thick1. Most biological cells are 2-30 times thicker than this threshold, which means that a cell must be cut into consecutive slices with each slice reconstructed individually in order to approximate the contextual information of the entire cell. Fortunately, due to a larger penetration depth2, X-ray computed tomography bypasses the need to physically section a cell and enables imaging of intact cells and tissues on the micrometer or larger scale with tens to hundreds of nanometer spatial resolution. While the technique of soft x-ray microscopy has been extensively developed in synchrotron facilities, advancements in laboratory x-ray source designs now increase its accessibility by supporting commercial systems suitable for a standard laboratory. In this paper, we highlight a new commercial compact cryogenic soft x-ray microscope designed for a standard laboratory setting and explore its capabilities for mesoscopic investigations of intact prokaryotic and eukaryotic cells.

femtosecond crystallography↗

SU-E-I-46: Sample-Size Dependence of Model Observers for Estimating Low-Contrast Detection Performance From CT Images

Purpose: Recently, task-based assessment of diagnostic CT systems has attracted much attention. Detection task performance can be estimated using human observers, or mathematical observer models. While most models are well established, considerable bias can be introduced when performance is estimated from a limited number of image samples. Thus, the purpose of this work was to assess the effect of sample size on bias and uncertainty of two channelized Hotelling observers and a template-matching observer. Methods: The image data used for this study consisted of 100 signal-present and 100 signal-absent regions-of-interest, which were extracted from CT slices. The experimental conditions included two signal sizes and five different x-ray beam current settings (mAs). Human observer performance for these images was determined in 2-alternative forced choice experiments. These data were provided by the Mayo clinic in Rochester, MN. Detection performance was estimated from three observer models, including channelized Hotelling observers (CHO) with Gabor or Laguerre-Gauss (LG) channels, and a template-matching observer (TM). Different sample sizes were generated by randomly selecting a subset of image pairs, (N=20,40,60,80). Observer performance was quantified as proportion of correct responses (PC). Bias was quantified as the relative difference of PC for 20 and 80 image pairs. Results: For n=100, all observer models predicted human performance across mAs and signal sizes. Bias was 23% for CHO (Gabor), 7% for CHO (LG), and 3% for TM. The relative standard deviation, σ(PC)/PC at N=20 was highest for the TM observer (11%) and lowest for the CHO (Gabor) observer (5%). Conclusion: In order to make image quality assessment feasible in the clinical practice, a statistically efficient observer model, that can predict performance from few samples, is needed. Our results identified two observer models that may be suited for this task.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SLICING AND DICING THE MILKY WAY DISK IN THE SLOAN DIGITAL SKY SURVEY

We use the Stripe 82 proper-motion catalog of Bramich et al. to study the kinematics of Galactic disk stars in the solar neighborhood. We select samples of dwarf stars with reliable spectra and proper motions. They have cylindrical polar radii between 7 {<=} R {<=} 9 kpc, heights from the Galactic plane satisfying |z| {<=} 2 kpc, and span a range of metallicities -1.5 {<=} [Fe/H] {<=} 0. We develop a method for calculating and correcting for the halo contamination in our sample using the distribution of rotational velocities. Two Gaussians representing disk and halo populations are used to fit the radial (v{sub R} ) and vertical (v{sub z} ) velocity distributions via maximum likelihood methods. For the azimuthal velocities (v{sub {phi}}) the same technique is used, except that a skewed non-Gaussian functional form now represents the disk velocity distribution. This enables us to compute the dispersions {sigma}{sub R}, {sigma}{sub z}, {sigma}{sub {phi}}, and cross-terms (the tilt {sigma}{sub Rz} and the vertex deviation {sigma}{sub R{phi}}) of the velocity ellipsoid as a function of height and metallicity. We also investigate the rotation lag of the disk, finding that the more metal-poor stars rotate significantly slower than the metal-rich stars. These samples provide important constraints on heating mechanisms in the Galactic disk and can be used for a variety of applications. We present one such application employing the Jeans equations to provide a simple model of the potential close to the disk. Our model is in excellent agreement with others in the literature and provides an indication that the disk, rather than the halo, dominates the circular speed at the solar neighborhood. We obtain a surface mass density within 1.1 kpc of around 66 M{sub Sun} pc{sup -2} and estimate a local halo density of 0.015 M{sub Sun} pc{sup -3} = 0.57 GeV cm{sup -3}.

79 ASTRONOMY AND ASTROPHYSICS↗