Search NASA⌕ Search

SEARCH · Search NASA

Results for “sludge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

DEMONSTRATION OF THE DWPF FLOWSHEET IN THE SRNL SHIELDED CELLS USING ARP PRODUCT SIMULANT AND SB4 TANK 40 SLUDGE SLURRY

The radioactive startup of two new SRS processing facilities, the Actinide Removal Process (ARP) and the Modular Caustic-Side-Solvent-Extraction Unit (MCU) will add two new waste streams to the Defense Waste Processing Facility (DWPF). The ARP will remove actinides from the 5.6 M salt solution resulting in a sludge-like product that is roughly half monosodium titanate (MST) insoluble solids and half sludge insoluble solids. The ARP product will be added to the Sludge Receipt and Adjustment Tank (SRAT) at boiling and dewatered prior to pulling a SRAT receipt sample. The cesium rich MCU stream will be added to the SRAT at boiling after both formic and nitric acid have been added and the SRAT contents concentrated to the appropriate endpoint. A concern was raised by an external hydrogen review panel that the actinide loaded MST could act as a catalyst for hydrogen generation (Mar 15, 2007 report, Recommendation 9). Hydrogen generation, and it's potential to form a flammable mixture in the off-gas, under SRAT and Slurry Mix Evaporator (SME) processing conditions has been a concern since the discovery that noble metals catalyze the decomposition of formic acid. Radiolysis of water also generates hydrogen, but the radiolysis rate is orders of magnitude lower than the noble metal catalyzed generation. As a result of the concern raised by the external hydrogen review panel, hydrogen generation was a prime consideration in this experiment. Testing was designed to determine whether the presence of the irradiated ARP simulant containing MST caused uncontrolled or unexpected hydrogen production during experiments simulating the DWPF Chemical Process Cell (CPC) due to activation of titanium. A Shielded Cells experiment, SC-5, was completed using SB4 sludge from Tank 405 combined with an ARP product produced from simulants by SRNL researchers. The blend of sludge and MST was designed to be prototypic of planned DWPF SRAT and SME cycles. As glass quality was not an objective in this experiment, no vitrification of the SME product was completed. The results from this experiment were compared to the results from experiment SC-1, a similar experiment with SB4 sludge without added ARP product. This report documents: (1) The preparation and subsequent composition of the ARP product. (2) The preparation and subsequent compositional characterization of the SRAT Receipt sample. Additional details will be presented concerning the noble metal concentration of the ARP product and the SRAT receipt sample. Also, calculations related to the amount of formic and nitric acid added during SRAT processing will be presented as excess formic acid will lead to additional hydrogen generation. (3) Highlights from processing during the SRAT cycle and SME cycle (CPC processing). Hydrogen generation will be discussed since this was the prime objective for this experiment. (4) A comparison of CPC processing between SC-1 (without ARP simulant) and SC-5. This work was controlled by a Task Technical and Quality Assurance Plan (TTQAP)6, and analyses were guided by an Analytical Sample Support Matrix (ASSM)7. This Research and Development (R&D) was completed to support operation of DWPF.

08 HYDROGEN↗

SLUDGE TREATMENT PROJECT ALTERNATIVES ANALYSIS SUMMARY REPORT [VOLUME 1]

Highly radioactive sludge (containing up to 300,000 curies of actinides and fission products) resulting from the storage of degraded spent nuclear fuel is currently stored in temporary containers located in the 105-K West storage basin near the Columbia River. The background, history, and known characteristics of this sludge are discussed in Section 2 of this report. There are many compelling reasons to remove this sludge from the K-Basin. These reasons are discussed in detail in Section1, and they include the following: (1) Reduce the risk to the public (from a potential release of highly radioactive material as fine respirable particles by airborne or waterborn pathways); (2) Reduce the risk overall to the Hanford worker; and (3) Reduce the risk to the environment (the K-Basin is situated above a hazardous chemical contaminant plume and hinders remediation of the plume until the sludge is removed). The DOE-RL has stated that a key DOE objective is to remove the sludge from the K-West Basin and River Corridor as soon as possible, which will reduce risks to the environment, allow for remediation of contaminated areas underlying the basins, and support closure of the 100-KR-4 operable unit. The environmental and nuclear safety risks associated with this sludge have resulted in multiple legal and regulatory remedial action decisions, plans,and commitments that are summarized in Table ES-1 and discussed in more detail in Volume 2, Section 9.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of Sludge Batch 5 Qualification with ISDP Salt Batch 1 Compliance to DWPF Waste Acceptance Criteria

The purpose of this report is to document the acceptability of Sludge Batch 5 with the initial macrobatch operation of the Interim Salt Disposition Project (ISDP) waste to the Defense Waste Processing Facility (DWPF). This report was prepared to comply with the requirements listed in the Waste Acceptance Criteria for Sludge, Actinide Removal Process (ARP), and Modular Caustic Side Solvent Extraction Unit (MCU) Process Transfers to 512-S and DWPF. The requirements for transfers to 512-S were evaluated during ISDP Salt Batch 1 qualification. The calculations of sludge concentrations are based entirely on the Tank 51 sample processed at SRNL. This is conservative because Tank 51 is blended with the dilute feed in the DWPF Feed Tank (Tank 40). This report documents the acceptability of sludge only as well as Sludge Batch 5 sludge slurry combined with ARP/MCU products for feed to DWPF. All criteria were met for unblended Tank 51 material.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

AK Re-evaluation of Rocky Flats Pond Sludge: Planning for Surprises - 16218

The Advanced Mixed Waste Treatment Project (AMWTP) uses the Sludge Repack Process (SRP) to treat prohibited liquids in retrieved containers of sludge originally stored in the early 1970's. Many of these containers were generated in the Rocky Flats Plant 2. Stage Sludge process. In June, 2015, operators at SRP identified containers of waste with historical IDs beginning with the prefix 742, indicating they were from the 2. stage process, but which were marked with the words 'Pond Sludge' and contained unusual waste such as rolled asphalt and plant material. This event required a reevaluation of the AK, which concluded that the pond sludge containers were from the same generating process as the rest of the 2. stage sludge, and did not change the hazardous waste numbers, waste material parameters or waste matrix code. This case study demonstrated the uncertainty inherent in all AK because of the long time period between generation of the waste and current characterization. Records are missing, unreadable, and difficult to interpret; memories are faulty; and containers continue to surprise us with unexpected waste. AK must be continually reevaluated and updated throughout the life of the project. When disposing of legacy waste, conditions such as that described in this case study should be expected and planned for. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Protecting the Columbia River through Removal and Packaging of Radioactive Sludge in Hanford's K Area - 16572

The Columbia River once provided power and cooling water to operations on the Hanford Site; today, more than a million people downstream from Hanford rely on the river for agriculture, fishing and recreation. The Department of Energy and contractor CH2M HILL Plateau Remediation Company (CH2M) is making significant progress in protecting that vital resource. Eight of nine reactors along the river have been cocooned and soil and groundwater remediation is successfully reducing the concentration of contaminants in groundwater. The 100-K area is the last area where significant work remains to protect the river. CH2M has accomplished much in the past ten years, including demolishing the K East reactor fuel storage basin in 2009. Prior to demolition of the basin, highly radioactive sludge from that basin was transferred into containers located in the nearby K West reactor fuel storage basin. Today, the K East reactor is in interim surveillance mode, and work is underway in the K West basin to remove the sludge, which is a mixture of tiny fuel corrosion particles, fuel rod and metal fragments and soil and sand less than 1/4-inch in diameter. CH2M has designed a sludge removal system that will safely and efficiently remove the sludge from the K West basin and deposit it into specially designed containers which will be relocated to a storage facility on Hanford's Central Plateau. Procurement, fabrication and delivery of the sludge removal system is underway, with extensive testing and training planned for 2016 and 2017 ahead of the goal of removing sludge from the river by September 30, 2018. This project must account for many technical and safety considerations that render the project very challenging. Several safety measures have been incorporated as a result of safety evaluations. This paper will describe the issues facing the project team in developing the safety basis requirements and incorporating them into the design of the process equipment and construction of the facility to house the repackaging operations. This paper will allow CH2M and DOE-RL to share lessons learned and progress to date with other complex and hazardous projects across the DOE complex. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Disposal of a pretreated oil sludge by the cementation method

Radioactive oil sludge is generated in oil production rigs worldwide and in large quantities. However, in Brazil, there is no disposal route or well-defined treatment option for this waste. This sludge is classified as TENORM due to the presence of Potassium-40 and the radionuclides of the natural decay chains of thorium and uranium. The management of this radioactive waste has been in situ packaging on the offshore platforms, followed by its transport to storage facilities onshore. Long term storage is problematic due to the high content of hydrocarbons, sulfur and water, which generates the toxic gas H{sub 2}S and the corrosive sulfuric acid. Ozonation, an advanced oxidation process (AOP) can be considered an attractive option of treatment, and followed by cementation can improve safety in long-term storage. This work aims at investigating if the ozone process was able to enhance the immobilization capacity of oil sludge. Oil sludge from different drums and mixed oil sludge (obtained by mixing equal parts of each drum) were analyzed by ICP. Solidification of oil sludge with Portland cement enhances safety of the waste disposal. In addition, ozonation treatment is efficient in the degradation of organic compounds, increasing the resistance of the solidified material.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Actual Waste Demonstration of the Nitric-Glycolic Flowsheet for Sludge Batch 9 Qualification

For each sludge batch that is processed in the Defense Waste Processing Facility (DWPF), the Savannah River National Laboratory (SRNL) performs qualification testing to demonstrate that the sludge batch is processable. Testing performed by the Savannah River National Laboratory has shown glycolic acid to be effective in replacing the function of formic acid in the DWPF chemical process. The nitric-glycolic flowsheet reduces mercury, significantly lowers the catalytic generation of hydrogen and ammonia which could allow purge reduction in the Sludge Receipt and Adjustment Tank (SRAT), stabilizes the pH and chemistry in the SRAT and the Slurry Mix Evaporator (SME), allows for effective rheology adjustment, and is favorable with respect to melter flammability. In order to implement the new flowsheet, SRAT and SME cycles, designated SC-18, were performed using a Sludge Batch (SB) 9 slurry blended from SB8 Tank 40H and Tank 51H samples. The SRAT cycle involved adding nitric and glycolic acids to the sludge, refluxing to steam strip mercury, and dewatering to a targeted solids concentration. Data collected during the SRAT cycle included offgas analyses, process temperatures, heat transfer, and pH measurements. The SME cycle demonstrated the addition of glass frit and the replication of six canister decontamination additions. The demonstration concluded with dewatering to a targeted solids concentration. Data collected during the SME cycle included offgas analyses, process temperatures, heat transfer, and pH measurements. Slurry and condensate samples were collected for subsequent analysis

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Selection of Glasses in Support of the Sludge Batch 9 Sulfate Solubility Limit for Coupled Operation with the Salt Waste Processing Facility

For Sludge Batches 3 through 8, the sulfate (SO 4 2- )solubility limit for the Defense Waste Processing Facility (DWPF) has been determined by laboratory-scale crucible testing. In preparation for Sludge Batch 9 (SB9) processing, a comparison demonstrated that minor compositional differences existed between the Sludge Batch 8 (SB8)-Frit 803 and SB9-Frit 803 glass composition regions for sludge-only and coupled operations with the Actinide Removal Process (ARP) and Modular Caustic Side Solvent Extraction Unit (MCU). Thus, no experimental testing was necessary and the SB8 SO 4 2- limit of 0.65 wt.% was recommended for SB9 processing. This previous SB9 assessment did not address coupled processing with streams from the Salt Waste Processing Facility (SWPF), which is anticipated to start operations in November 2019. These high activity streams will include monosodium titanate (MST) and sludge solids from the Sludge Solids Receipt Tank (SSRT) as well as Cs-containing strip effluent (SE). The incorporation of these SWPF streams is expected to reach TiO 2 concentrations in glass greater than 2 wt.% based on single and double MST strike scenarios. In support of coupled operation with SWPF, the DWPF Product Composition Control System was revised and allows a TiO 2 concentration of up to 6 wt.% (minus measurement uncertainty) in glass. For the SB8-Frit 803 SO 4 2- solubility study, the maximum TiO 2 concentration evaluated was 0.94 wt.%. Since the influence of increased TiO 2 on the retention of SO 4 2- in the SB9 glass region is unknown, a test matrix of ten glass compositions has been proposed to determine whether the 0.65 wt.% SO 4 2- limit is still appropriate for SB9 coupled operation with SWPF. This report documents the development of a test matrix that will support this study.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sludge Batch 10 Flowsheet Testing with Non-radioactive Simulants

Fourteen Chemical Processing Cell (CPC) simulations were performed with nonradioactive sludge simulants at the Aiken County Technology Laboratory in Aiken, SC. Four of these experiments were performed with Tank 51 sludge simulant. The remaining ten were performed with Tank 40 sludge simulant. The purpose of these experiments was to elucidate the chemistry and characteristics of Sludge Batch (SB) 10 as anticipated in the Defense Waste Processing Facility (DWPF). Experiments were performed at acid stoichiometries between 76% and 138% of the Koopman Minimum Acid requirement (85% - 144% of the Hsu acid requirement) and at REDuction/OXidation (REDOX) targets between 0.1 and 0.3. Testing examined the impact of coupled operations and sludge-only operations during Sludge Receipt and Adjustment Tank (SRAT) and Slurry Mix Evaporator (SME) processing at both design basis and nominal boilup rates. This report shares conclusions made as a result of this testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Corrosion Testing of Carbon Steel Exposed to Sludge Heel Chemical Cleaning Solutions - 16109

As efforts continue to treat and dispose of millions of gallons of legacy radioactive materials from the production of nuclear weapons, non-compliant waste storage tanks will gradually be emptied of the bulk waste volume leaving heel materials requiring removal prior to tank closure. The waste heel slurries are distributed on the floor of large, million gallon tanks, which frequently contain numerous obstructions that limit the effectiveness of mechanical removal methods. As a result, chemical cleaning methods are needed for the effective removal of the heels as well as chemical scales that are present on the tank walls and other interior surfaces. Two tank cleaning technologies have already been implemented at the Savannah River Site (SRS): Low Temperature Aluminum Dissolution (LTAD) and Bulk Oxalic Acid Cleaning (BOAC). Recent chemical cleaning efforts on SRS Tank 12 were very successful with regard to bulk sludge heel (especially for Al, Fe, and U phases) and beta/gamma radionuclide removal. Although chemical cleaning using these technologies has been shown to be effective, no disposition path has been identified for oxalate added during BOAC, and insoluble oxalate salts are accumulating within the SRS tank farm and waste processing facilities (evaporators, etc.). Extensive sludge washing is also required to remove moderately soluble sodium oxalate salts prior to sludge vitrification in the SRS Defense Waste Processing Facility (DWPF). As a result, oxalate additions to the tank farm need to be minimized by the use of supplementary acids to assist sludge removal in OA or the use of other cleaning reagents or processing strategies. Previous SRNL testing revealed the importance of pH control for BOAC and recommended the use of a supplementary acid (dilute HNO{sub 3}) with OA to minimize oxalate additions. Primary drivers in SRS Tank Closure Performance Assessments, which evaluate the fate and impact of tank sludge residuals on a geological timescale, are the removal of alpha emitting radionuclides present at low concentrations such as Pu, Am, and Np, which are not highly soluble in currently utilized chemical cleaning reagents. Scoping studies conducted at SRNL revealed promising methods to dissolve the actinides within the HLW tank heels. Oxidation of the actinides with permanganate in either strong caustic (10 M NaOH) or dilute acidic (0.2 M HNO{sub 3}) solutions was shown to result in dissolution of oxy/hydroxide phases of these metals in the absence of major sludge phases. The waste tanks at SRS and Hanford are constructed of carbon steel. Carbon steel corrodes rapidly in most acidic and/or oxidizing environments. Previous electrochemical corrosion testing indicated that the corrosion rates in dilute HNO{sub 3} with OA may result in manageable corrosion rates, over short exposure periods. Additional corrosion testing was performed to provide data for the nitric acid/OA blend as well as the acid/permanganate and caustic permanganate based chemical cleaning solutions. Corrosion rates from the passive coupon tests for the nitric acid/oxalic acid blend were significantly greater than those observed previously with the electrochemical testing. This result may be due to simultaneous electrochemical and chemical dissolution of the steel. The corrosion rate data from the coupon tests in the nitric acid/oxalic acid blend were evaluated to determine the degree of potential structural damage. The corrosion rates, although relatively high, would not be expected to cause damage that would reduce the capacity of the tank primary wall if the process is completed within a month. The corrosivity of sodium permanganate in four proposed cleaning solutions, 1 nitric acid solution and 3 sodium hydroxide solutions, was studied by electrochemical methods at room temperature. The corrosion rates were significantly less aggressive than in the nitric acid/oxalic acid blend corrosion tests. Passive coupon tests needs to be performed in these solutions to ensure that chemical dissolution of the metal is not occurring simultaneously. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Deployment of Low Temperature Aluminum Dissolution (LTAD) Technology to Retrieve H-Modified (HM) Sludge in SRS Tank 15 – 25672

Tank 15 is a 4,234,000-liter (1,118,500-gallon) Type 2 high-level waste storage tank located in H Tank Farm at the Savannah River Site. It was put into service in 1960 to receive high-activity, H-Modified (HM) waste from H Canyon. Between June 1964 and November 1972, the waste tank was filled six times, and supernate was decanted five times, leaving behind the sludge solids. Tank 15 also received a mixture of high-activity and low-activity HM waste from Tank 16. Tank 15 has more recently undergone several mixing campaigns to remove much of the sludge waste; however, the effectiveness of suspending the sludge heel via mechanical mixing has significantly diminished. Low Temperature Aluminum Dissolution (LTAD) is a process developed for the dissolution of suspended aluminum solids in a large waste storage tank. Originally intended for deployment during the preparation of sludge batches in H Tank Farm for the Defense Waste Processing Facility (DWPF), the process involves maintaining the waste storage tank at a slightly elevated temperature and highly alkaline chemistry to facilitate dissolution of aluminum solids. As mechanical heel removal efforts diminished in effectiveness in Tank 15, LTAD was selected to both reduce the volume of sludge solids remaining in the heel and to modify the sludge rheology to facilitate the suspension of additional solids using the installed mixing devices.

Campbell, Seth G.↗

Degradation of triclosan and triclocarban and formation of transformation products in activated sludge using benchtop bioreactors

Highlights: • Benchtop bioreactors were run with activated sludge for 122 – 196 h. • Extended HRT and SRT and increased temperatures on TCS, TCC, and their byproducts were studied. • Prolonged HRT and SRT resulted in more efficient TCS and TCC removal. • Increases in reactor temperature improved TCS and TCC degradation. • Significant MeTCS formation was observed. Benchtop bioreactors were run aerobically with activated sludge samples collected from a large municipal wastewater treatment plant (WWTP) to understand how increased hydraulic retention time (HRT), sludge retention time (SRT), and varying treatment temperatures (21 °C and 30 °C) impact concentrations of the endocrine disrupting antimicrobials triclosan (TCS), triclocarban (TCC), and their transformation products. Samples from the reactors were collected periodically over a 122–196 h period and the solid and liquid fraction were separately quantitated for TCS, TCC, and methyltriclosan (MeTCS) and scanned qualitatively for six other transformation products. Results indicated that TCS, TCC and MeTCS were predominately associated with the solids fraction of the activated sludge with only nominal concentrations in the liquids fraction. TCS was degraded in the solids fraction, with increased rates at 30 °C (−0.0224 ± 0.007 h{sup −1}) when compared to reactors run at 21 °C (− 0.0170 ± 0.003 h{sup −1}). Conversely, TCC concentrations did not significantly change in solids samples from reactors run at 21 °C, while an increase in reactor temperature to 30 °C resulted in TCC degradation at an average rate of − 0.0158 ± 0.012 h{sup −1}. Additionally, MeTCS formation in the solids fraction was observed in three out of four reactors run - indicating a notable transformation of TCS. Qualitative appearance of 2,4-dichlorophenol and 4-chloroanaline was observed in the liquids fraction of all reactor samples. The remaining four qualitatively scanned compounds were not detected. These experiments demonstrate that increased HRT, SRT, and temperature result in enhanced removal of TCS and TCC from wastewater during the activated sludge process. Furthermore, a substantial formation of TCS into MeTCS was observed.

54 ENVIRONMENTAL SCIENCES↗

Modeling of the reburning process using sewage sludge-derived syngas

Highlights: Black-Right-Pointing-Pointer Gasification provides an attractive method for sewage sludges treatment. Black-Right-Pointing-Pointer Gasification generates a fuel gas (syngas) which can be used as a reburning fuel. Black-Right-Pointing-Pointer Reburning potential of sewage sludge gasification gases was defined. Black-Right-Pointing-Pointer Numerical simulation of co-combustion of syngases in coal fired boiler has been done. Black-Right-Pointing-Pointer Calculation shows that analysed syngases can provide higher than 80% reduction of NO{sub x}. - Abstract: Gasification of sewage sludge can provide clean and effective reburning fuel for combustion applications. The motivation of this work was to define the reburning potential of the sewage sludge gasification gas (syngas). A numerical simulation of the co-combustion process of syngas in a hard coal-fired boiler was done. All calculations were performed using the Chemkin programme and a plug-flow reactor model was used. The calculations were modelled using the GRI-Mech 2.11 mechanism. The highest conversions for nitric oxide (NO) were obtained at temperatures of approximately 1000-1200 K. The combustion of hard coal with sewage sludge-derived syngas reduces NO emissions. The highest reduction efficiency (>90%) was achieved when the molar flow ratio of the syngas was 15%. Calculations show that the analysed syngas can provide better results than advanced reburning (connected with ammonia injection), which is more complicated process.

01 COAL, LIGNITE, AND PEAT↗

Degradation and environmental risk of surfactants after the application of compost sludge to the soil

Highlights: Black-Right-Pointing-Pointer Degradation of surfactants in soil amended with sewage sludge during 100 days. Black-Right-Pointing-Pointer Temperature influences on the degradation of the studied compounds. Black-Right-Pointing-Pointer Overall, the LAS degradation is faster than the NP compounds degradation. Black-Right-Pointing-Pointer Therefore, the LAS presented lower environmental risk than the NP compounds. - Abstract: In this work, the degradation of anionic and non-ionic surfactants in agricultural soil amended with sewage sludge is reported. The compounds analysed were: linear alkylbenzene sulphonates (LAS) with a 10-13 carbon alkylic chain, and nonylphenolic compounds (NPE), including nonylphenol (NP) and nonylphenol ethoxylates with one and two ethoxy groups (NP1EO and NP2EO). The degradation studies were carried out under winter (12.7 Degree-Sign C) and summer (22.4 Degree-Sign C) conditions in Andalusia region. The concentration of LAS was reduced to 2% of the initial concentration 100 day after sludge-application to the soil. The half-life time measured for LAS homologues were ranged between 4 and 14 days at 12.7 Degree-Sign C and between 4 and 7 days at 22.4 Degree-Sign C. With regard to NPE compounds, after 8 and 4 days from the beginning of the experiment at 12.7 and 22.4 Degree-Sign C, respectively, their concentration levels were increased to 6.5 and 13.5 mg/kg dm (dry matter) as consequence of the degradation of nonylphenol polyethoxylates. These concentration levels were reduced to 5% after 63 and 70 days for 12.7 Degree-Sign C and 22.4 Degree-Sign C, respectively. The half-life times measured for NPEs were from 8 to 16 days at 12.7 Degree-Sign C and from 8 to 18 days at 22.4 Degree-Sign C. Environmental risk assessment revealed that for LAS homologues no environment risk could be expected after 7 and 8 days of sludge application to the soil for 22.4 and 12.7 Degree-Sign C, respectively; however, potential toxic effects could be observed for the nonylphenolic compounds during the first 56 days after sludge application to the soil.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Life-Cycle Assessment of Sustainable Aviation Fuel Derived from Paper Sludge

Converting waste paper sludge to sustainable aviation fuel (SAF) offers a circular economy strategy to decarbonize the aviation sector. Here, this study develops a life-cycle assessment (LCA) for converting high-ash paper sludge to SAF in the U.S. using a catalytic sugar upgrading system that consists of ash removal, enzymatic hydrolysis, dehydration, aldol condensation, and hydroprocessing. The LCA is coupled with a process simulation for an industrial-scale biorefinery based on experimental data. We quantified the carbon intensity as 35.7–41.8 gCO 2 eq MJ –1 SAF (–636 to –584 gCO 2 eq per dry kg paper sludge) with acetone as a solvent, renewable fuel, and biobased chemicals; this is further reduced to 5.1–11.1 gCO 2 eq MJ –1 (–925 to –873 gCO 2 eq per dry kg paper sludge) if ash is recycled and used for substituting cement. Converting 1 dry kg paper sludge to SAF with acetone, renewable fuel, and biobased chemicals (–925 to –584 gCO 2 eq) is more climate beneficial than landfilling without landfill gas recovery (791 gCO 2 eq) and with landfill gas recovery (–294 gCO 2 eq). More than 330 million gallons of SAF can be produced annually (>4 million dry t paper sludge/year in the U.S.), resulting in a reduction of 2–7 million tCO 2 eq.

09 BIOMASS FUELS↗

Experimental Investigation of the Impact of Cathode Grade on Sludge Formation at the Cathode Block-Aluminum Interface of Hall–Héroult Cells

The presence of resistive sludge on the cathode surface in Hall–Héroult cells can increase the aluminum production costs and reduces cell lifetime. Modern cells with graphitized cathode blocks generally operate satisfactorily but some are exhibiting excessive deposit formation, thus lower performances. Little attention has ever been given to the role of the cathode grade and its properties on sludge formation. In this investigation, five graphitized industrial cathode grades with varying properties are tested on a bench scale aluminum electrolysis setup with cathodic current density of 0.9 A/cm{sup 2}, under a nitrogen atmosphere at 1233 K (960 °C) for 8 hours with initial bath composition of 10 pct alumina, cryolite ratio of 2.2, 5 pct CaF{sub 2} and no point feeding. Postmortem characterization includes Rietveld refinement of deposits, optical microscopy and SEM-EDS observations of the carbon-aluminum interface. Sludge located near the center of the cathode surface was generated during the experiments despite the absence of point feeding. The sludge profile was variable among grades and could be related to the horizontal and vertical thermal conductivities of the blocks. This study has pushed further the understanding of the mechanisms of sludge formation and dissolution concerning the cathode grade properties.

36 MATERIALS SCIENCE↗

Hydrothermal liquefaction of sewage sludge – effect of four reagents on relevant parameters related to biocrude and $\mathrm{PFAS}$

Catalytic hydrothermal liquefaction (HTL) can convert wet biomass into crude-like oil and has potential to degrade pollutants during the thermal depolymerization process. To avoid negative environmental impacts from per- and polyfluoroalkyl substances (PFAS) in sewage sludge after its final disposal, we comprehensively evaluated catalytic destruction of PFAS in sludge through HTL. Here the results showed that adding red mud to HTL was beneficial for the biocrude yield and significantly increased the carbon conversion efficiency and energy recovery of the hydrothermal process. HTL at 300 °C for 2 h degraded > 96% of spiked perfluorooctanoic acid (PFOA). The mass of spiked perfluorobutanesulfonic acid (PFBS) and perfluorooctanesulfonic acid (PFOS) and pre-existing perfluorohexanoic acid (PFHxA) and perfluoroheptanoic acid (PFHpA), however, increased in the HTL product streams. The remaining PFAS after HTL mainly stayed in the biocrude phase. Our findings indicated that HTL under the studied condition was not able to degrade all PFAS existed in sewage sludge. Although adding red mud could improve the HTL performance with respect to biocrude, this reagent did not improve the removal of perfluoroalkyl acids (PFAAs). As a matter of fact, the hydrothermal process amended with the selected reagents resulted in increased mass of PFBS, PFHxA, and PFHpA in the HTL products due to degradation of PFAA precursors. Thus, other treatment approaches for PFAS removal from sewage sludge need to be identified to prevent possible contamination of environments receiving PFAS-containing sludge.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hydration and leaching characteristics of cement pastes made from electroplating sludge

The purpose of this study was to investigate the hydration and leaching characteristics of the pastes of belite-rich cements made from electroplating sludge. The compressive strength of the pastes cured for 1, 3, 7, 28, and 90 days was determined, and the condensation of silicate anions in hydrates was examined with the {sup 29}Si nuclear magnetic resonance (NMR) technology. The leachabilities of the electroplating sludge and the hardened pastes were studied with the multiple toxicity characteristic leaching procedure (MTCLP) and the tank leaching test (NEN 7345), respectively. The results showed that the electroplating sludge continued to leach heavy metals, including nickel, copper, and zinc, and posed a serious threat to the environment. The belite-rich cement made from the electroplating sludge was abundant in hydraulic {beta}-dicalcium silicate, and it performed well with regard to compressive-strength development when properly blended with ordinary Portland cements. The blended cement containing up to 40% the belite-rich cement can still satisfy the compressive-strength requirements of ASTM standards, and the pastes cured for 90 days had comparable compressive strength to an ordinary Portland cement paste. It was also found that the later hydration reaction of the blended cements was relatively more active, and high fractions of belite-rich cement increased the chain length of silicate hydrates. In addition, by converting the sludge into belite-rich cements, the heavy metals became stable in the hardened cement pastes. This study thus indicates a viable alternative approach to dealing with heavy metal bearing wastes, and the resulting products show good compressive strength and heavy-metal stability.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗