Search NASA⌕ Search

SEARCH · Search NASA

Results for “software compatibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

"Reducing Detailed Vehicle Energy Dynamics to Physics-Like Models"

The energy demand of vehicles, particularly in unsteady drive cycles, is affected by complex dynamics internal to the engine and other powertrain components. Yet, in many applications, particularly macroscopic traffic flow modeling and optimization, structurally simple approximations to the complex vehicle dynamics are needed that nevertheless reproduce the correct effective energy behavior. This work presents a systematic model reduction pipeline that starts from complex vehicle models based on the Autonomie software and derives a hierarchy of simplified models that are fast to evaluate, easy to disseminate in open-source frameworks, and compatible with optimization frameworks. The pipeline, based on a virtual chassis dynamometer and subsequent approximation strategies, is reproducible and is applied to six different vehicle classes to produce concrete explicit energy models that represent an average vehicle in each class and leverage the accuracy and validation work of the Autonomie software.

Khoudari, Nour↗

Wireless Demand Response Controls for HVAC Systems

The objectives of this scoping study were to develop and test control software and wireless hardware that could enable closed-loop, zone-temperature-based demand response in buildings that have either pneumatic controls or legacy digital controls that cannot be used as part of a demand response automation system. We designed a SOAP client that is compatible with the Demand Response Automation Server (DRAS) being used by the IOUs in California for their CPP program, design the DR control software, investigated the use of cellular routers for connecting to the DRAS, and tested the wireless DR system with an emulator running a calibrated model of a working building. The results show that the wireless DR system can shed approximately 1.5 Watts per design CFM on the design day in a hot, inland climate in California while keeping temperatures within the limits of ASHRAE Standard 55: Thermal Environmental Conditions for Human Occupancy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

In Vivo Dosimetry of High-Dose-Rate Interstitial Brachytherapy in the Pelvic Region: Use of a Radiophotoluminescence Glass Dosimeter for Measurement of 1004 Points in 66 Patients With Pelvic Malignancy

Purpose: To perform the largest in vivo dosimetry study for interstitial brachytherapy yet to be undertaken using a new radiophotoluminescence glass dosimeter (RPLGD) in patients with pelvic malignancy and to study the limits of contemporary planning software based on the results. Patients and Methods: Sixty-six patients with pelvic malignancy were treated with high-dose-rate interstitial brachytherapy, including prostate (n = 26), gynecological (n = 35), and miscellaneous (n = 5). Doses for a total of 1004 points were measured by RPLGDs and calculated with planning software in the following locations: rectum (n = 549), urethra (n = 415), vagina (n = 25), and perineum (n = 15). Compatibility (measured dose/calculated dose) was analyzed according to dosimeter location. Results: The compatibility for all dosimeters was 0.98 {+-} 0.23, stratified by location: rectum, 0.99 {+-} 0.20; urethra, 0.96 {+-} 0.26; vagina, 0.91 {+-} 0.08; and perineum, 1.25 {+-} 0.32. Conclusions: Deviations between measured and calculated doses for the rectum and urethra were greater than 20%, which is attributable to the independent movements of these organs and the applicators. Missing corrections for inhomogeneity are responsible for the 9% negative shift near the vaginal cylinder (specific gravity = 1.24), whereas neglect of transit dose contributes to the 25% positive shift in the perineal dose. Dose deviation of >20% for nontarget organs should be taken into account in the planning process. Further development of planning software and a real-time dosimetry system are necessary to use the current findings and to achieve adaptive dose delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

OpenFlow arbitrated programmable network channels for managing quantum metadata

Quantum networks must classically exchange complex metadata between devices in order to carry out information for protocols such as teleportation, super-dense coding, and quantum key distribution. Demonstrating the integration of these new communication methods with existing network protocols, channels, and data forwarding mechanisms remains an open challenge. Software-defined networking (SDN) offers robust and flexible strategies for managing diverse network devices and uses. We adapt the principles of SDN to the deployment of quantum networks, which are composed from unique devices that operate according to the laws of quantum mechanics. We show how quantum metadata can be managed within a software-defined network using the OpenFlow protocol, and we describe how OpenFlow management of classical optical channels is compatible with emerging quantum communication protocols. We next give an example specification of the metadata needed to manage and control quantum physical layer (QPHY) behavior and we extend the OpenFlow interface to accommodate this quantum metadata. Here, we conclude by discussing near-term experimental efforts that can realize SDN’s principles for quantum communication.

97 MATHEMATICS AND COMPUTING↗

Towards Vendor and Operating System Independence of USB-based portable multi-channel analyzers

The nuclear measurements group is called on to develop portable, user friendly systems that performs at, or near, laboratory standards. These systems typically consist of a detector and a USB-based multi-channel analyzer. An ORTEC digi-Base is an example of a USB-based portable multi-channel analyzer with 14-pin photomultiplier tube base for gamma-ray spectroscopy applications with NaI(Tl) and other scintillation detectors. Operating system independence - we want to be able to develop applications that are 'future-proof' and can run on the best hardware for the job: desktop, laptop, tablet, phone, or embedded device. To do that we need our software to be operating system independent. Hardware vendor independence - to use the most appropriate equipment for the job, while still maintaining our rapid method development, we would like our software that uses this equipment to be independent of the specific vendor or model of the hardware. To do that we need a common interface to each vendor's equipment (high voltage, gain, start, stop, clear, etc.) In prior work, we were able to use an existing library to communicate with an ORTEC digi-base via Linux and Android. However the application developed did not have a user friendly front-end. Part of this work was to develop a simple user interface to control the settings of the hardware from Android. While OS independence is the final goal, another goal is standardized software for user-application development. For current purposes those standard systems are Windows 7, Windows 10, and Python 3. Our next step was to develop a common software interface between a front-end user interface and back-end hardware communication software. This was done using Python's Ctypes library. Ctypes is a foreign function library for Python. It provides C compatible data types, and allows calling functions in DLLs or shared libraries. It can be used to wrap these libraries in pure Python. Ctypes exports the cdll, and Windows windll and oledll objects, for loading dynamic link libraries. You load libraries by accessing them as attributes of these objects. cdll loads libraries which export functions using the standard cdecl calling convention. The first steps of developing the common software interface have been done. Once the software interface has been developed the next goal will be to develop hardware specific back-end software that way rapid user facing software can be developed using equipment that is 'on-hand' and once finished prototyping, the 'best' hardware can be chosen for the specific implementation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characteristic Performance Evaluation of a new SAGe Well Detector for Small and Large Sample Geometries

Environmental scientific research requires a detector that has sensitivity low enough to reveal the presence of any contaminant in the sample at a reasonable counting time. Canberra developed the germanium detector geometry called Small Anode Germanium (SAGe) Well detector, which is now available commercially. The SAGe Well detector is a new type of low capacitance germanium well detector manufactured using small anode technology capable of advancing many environmental scientific research applications. The performance of this detector has been evaluated for a range of sample sizes and geometries counted inside the well, and on the end cap of the detector. The detector has energy resolution performance similar to semi-planar detectors, and offers significant improvement over the existing coaxial and Well detectors. Energy resolution performance of 750 eV Full Width at Half Maximum (FWHM) at 122 keV γ-ray energy and resolution of 2.0 - 2.3 keV FWHM at 1332 keV γ-ray energy are guaranteed for detector volumes up to 425 cm{sup 3}. The SAGe Well detector offers an optional 28 mm well diameter with the same energy resolution as the standard 16 mm well. Such outstanding resolution performance will benefit environmental applications in revealing the detailed radionuclide content of samples, particularly at low energy, and will enhance the detection sensitivity resulting in reduced counting time. The detector is compatible with electric coolers without any sacrifice in performance and supports the Canberra Mathematical efficiency calibration method (In situ Object Calibration Software or ISOCS, and Laboratory Source-less Calibration Software or LABSOCS). In addition, the SAGe Well detector supports true coincidence summing available in the ISOCS/LABSOCS framework. The improved resolution performance greatly enhances detection sensitivity of this new detector for a range of sample sizes and geometries counted inside the well. This results in lower minimum detectable concentrations compared to Traditional Well detectors. The SAGe Well detectors are compatible with Marinelli beakers and compete very well with semi-planar and coaxial detectors for large samples in many applications. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

One dimensional spatial resolution optimization on a hybrid low field MRI-gamma detector

Hybrid systems like Positron Emission Tomography/Magnetic Resonance Imaging (PET/MRI) and MRI/gamma camera, offer advantages combining the resolution and contrast capability of MRI with the better contrast and functional information of nuclear medicine techniques. However, the radiation detectors are expensive and need an electronic set-up, which can interfere with the MRI acquisition process or viceversa. In order to improve these drawbacks, in this work it is presented the design of a low field NMR system made up of permanent magnets compatible with a gamma radiation detector based on gel dosimetry. The design is performed using the software FEMM for estimation of the magnetic field, and GEANT4 for the physical process involved in radiation detection and effect of magnetic field. The homogeneity in magnetic field is achieved with an array of NbFeB magnets in a linear configuration with a separation between the magnets, minimizing the effect of Compton back scattering compared with a no-spacing linear configuration. The final magnetic field in the homogeneous zone is ca. 100 mT. In this hybrid proposal, although the gel detector do not have spatial resolution per se, it is possible to obtain a dose profile (1D image) as a function of the position by using a collimator array. As a result, the gamma detector system described allows a complete integrated radiation detector within the low field NMR (lfNMR) system. Finally we present the better configuration for the hybrid system considering the collimator parameters such as height, thickness and distance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anchoring

This software provides methods and functions for training deep image classification models based on the principle of anchoring. It features a user-friendly PyTorch wrapper that facilitates the easy conversion of any model into an anchored model. The software supports various standard datasets and includes scripts for conducting evaluations. Developed with PyTorch, it is compatible with common neural network architectures used for image data. Additionally, it offers tools for computing evaluation metrics to assess model performance.

Narayanaswamy, Vivek Sivaraman↗

Mu2e otsdaq Documentation and Online Reconstruction Analytics

This report outlines the results of the DOE-funded SULI (Science Undergraduate Laboratory Internship) research completed over the summer 2024 on site at Fermilab. The project focused on the \textit{otsdaq} software responsible for data acquisition. The project included drafting updated documentation for new users including new procedures relevant for the Alma-Linux 9 operating system update, and the UPS package managing system replacement with spack (scientific software package manager). A new \textit{art} module (ReadTriggerCounts) to track trigger rates was created, with compatibility to be displayed via a Grafana server. The author also assisted in calorimeter cable installation in the detector hall.

Saarinen, Talia↗

Novel principal component analysis tool based on python for analysis of complex spectra of time-of-flight secondary ion mass spectrometry

Time-of-flight secondary ion mass spectrometry (ToF-SIMS) is a powerful surface analysis tool, which can simultaneously provide elemental, isotopic, and molecular information with part per million (ppm) sensitivity. However, each spectrum may be composed of hundreds of ion signals, which makes the spectra data complex. Principal component analysis (PCA) is a multivariate analysis technique that has been widely used to figure out the variances among samples in ToF-SIMS spectra data analysis and is showing great success in the explanation of complex ToF-SIMS spectra. So far, several software tools have been developed for PCA of ToF-SIMS spectra; however, none of them are freely available. Such a situation leads to some difficulties in extending applications of PCA to various research fields. More importantly, it has long been challenging for common researchers to understand PCA plots and extract chemical differences among samples. In this work, we developed a new and flexible software tool (named “advanced spectra pca toolbox”) based on python for PCA of complex ToF-SIMS spectra along with an easy-to-read manual. It can generate data analysis reports automatically to explain chemical differences among samples, allowing less experienced researchers to easily understand tricky PCA results. Moreover, it is expandable and compatible with artificial intelligence/machine learning functions. Pure goethite and different lignin adsorbed goethite samples were used as a model system to demonstrate our new software tool, proving that our software tool can be readily used in complex spectra data processing. Our new software tool is open-source, convenient, flexible, and expandable. We expect this open-source tool will benefit the ToF-SIMS community.

47 OTHER INSTRUMENTATION↗

HighIQ

This software is for the processing of raw IQ data from radars and lidars that uses CUDA-compatible GPUs such as those in the Array of Things.

Jackson, RobertClyde↗

ASCR Science Network Requirements

The Energy Sciences Network (ESnet) is the primary provider of network connectivity for the US Department of Energy Office of Science, the single largest supporter of basic research in the physical sciences in the United States. In support of the Office of Science programs, ESnet regularly updates and refreshes its understanding of the networking requirements of the instruments, facilities, scientists, and science programs that it serves. This focus has helped ESnet to be a highly successful enabler of scientific discovery for over 20 years. In April 2009 ESnet and the Office of Advanced Scientific Computing Research (ASCR), of the DOE Office of Science, organized a workshop to characterize the networking requirements of the programs funded by ASCR. The ASCR facilities anticipate significant increases in wide area bandwidth utilization, driven largely by the increased capabilities of computational resources and the wide scope of collaboration that is a hallmark of modern science. Many scientists move data sets between facilities for analysis, and in some cases (for example the Earth System Grid and the Open Science Grid), data distribution is an essential component of the use of ASCR facilities by scientists. Due to the projected growth in wide area data transfer needs, the ASCR supercomputer centers all expect to deploy and use 100 Gigabit per second networking technology for wide area connectivity as soon as that deployment is financially feasible. In addition to the network connectivity that ESnet provides, the ESnet Collaboration Services (ECS) are critical to several science communities. ESnet identity and trust services, such as the DOEGrids certificate authority, are widely used both by the supercomputer centers and by collaborations such as Open Science Grid (OSG) and the Earth System Grid (ESG). Ease of use is a key determinant of the scientific utility of network-based services. Therefore, a key enabling aspect for scientists beneficial use of high performance networks is a consistent, widely deployed, well-maintained toolset that is optimized for wide area, high-speed data transfer (e.g. GridFTP) that allows scientists to easily utilize the services and capabilities that the network provides. Network test and measurement is an important part of ensuring that these tools and network services are functioning correctly. One example of a tool in this area is the recently developed perfSONAR, which has already shown its usefulness in fault diagnosis during the recent deployment of high-performance data movers at NERSC and ORNL. On the other hand, it is clear that there is significant work to be done in the area of authentication and access control - there are currently compatibility problems and differing requirements between the authentication systems in use at different facilities, and the policies and mechanisms in use at different facilities are sometimes in conflict. Finally, long-term software maintenance was of concern for many attendees. Scientists rely heavily on a large deployed base of software that does not have secure programmatic funding. Software packages for which this is true include data transfer tools such as GridFTP as well as identity management and other software infrastructure that forms a critical part of the Open Science Grid and the Earth System Grid.

97 MATHEMATICS AND COMPUTING↗

Development of Updated ABsorption SIMulation Software (ABSIM)

ABsorption SIMulation, ABSIM, was developed for the simulation of absorption systems by The Oak Ridge National Laboratory during 1980s and 1990s. ABSIM provides a platform for users to investigate various cycle configurations and working fluids, to calculate their operating parameters, to predict their performance, and to compare them with each other on a uniform basis. ABSIM is indeed a very useful and accurate tool for researchers to investigate various absorption systems. However, it has not been well maintained: it is incompatible with recent operating systems; the interface needs improved user-friendliness, and the system needs better parameter setting and debugging tools to help achieve convergence. Therefore, it is highly needed to update and improve ABSIM. The paper presents recent efforts to improve ABSIM s compatibility with current operating systems, user interface, and analysis capabilities. The paper details the features and functions of the newly updated ABSIM software. The new ABSIM still uses the previously validated calculation engine of the old ABSIM. The new graphic user interfaces (GUI) were developed in Qt, which is an open source license GUI software based on C++. XML was used as the database for data storage in the new ABSIM. The new ABSIM has been designed to be easily learned and used. It has enhanced editing and construction functions, plus enhanced analysis features including parametric tables, plotting, property plots, and master panels for debugging. A single effect water/LiBr absorption system is used as a case study in this paper to illustrate the features, capabilities, and functions of the new ABSIM. This case study was actually an example system available in the old ABSIM. The new version of ABSIM will be continuously developed to include additional subroutines for the components in liquid desiccant systems. The new ABSIM will be available to public for free. The ultimate goal of the new ABSIM is to allow it to become a simulation platform for both absorption heat pump and liquid desiccant systems.

ABSIM↗

RELAP5-3D Developer Guidelines and Programming Practices

Our ultimate goal is to create and maintain RELAP5-3D as the best software tool available to analyze nuclear power plants. This begins with writing excellent programming and requires thorough testing. This document covers development of RELAP5-3D software, the behavior of the RELAP5-3D program that must be maintained, and code testing. RELAP5-3D must perform in a manner consistent with previous code versions with backward compatibility for the sake of the users. Thus file operations, code termination, input and output must remain consistent in form and content while adding appropriate new files, input and output as new features are developed. As computer hardware, operating systems, and other software change, RELAP5-3D must adapt and maintain performance. The code must be thoroughly tested to ensure that it continues to perform robustly on the supported platforms. The coding must be written in a consistent manner that makes the program easy to read to reduce the time and cost of development, maintenance and error resolution. The programming guidelines presented her are intended to institutionalize a consistent way of writing FORTRAN code for the RELAP5-3D computer program that will minimize errors and rework. A common format and organization of program units creates a unifying look and feel to the code. This in turn increases readability and reduces time required for maintenance, development and debugging. It also aids new programmers in reading and understanding the program. Therefore, when undertaking development of the RELAP5-3D computer program, the programmer must write computer code that follows these guidelines. This set of programming guidelines creates a framework of good programming practices, such as initialization, structured programming, and vector-friendly coding. It sets out formatting rules for lines of code, such as indentation, capitalization, spacing, etc. It creates limits on program units, such as subprograms, functions, and modules. It establishes documentation guidance on internal comments. The guidelines apply to both existing and new subprograms. They are written for both FORTRAN 77 and FORTRAN 95. The guidelines are not so rigorous as to inhibit a programmer’s unique style, but do restrict the variations in acceptable coding to create sufficient commonality that new readers will find the coding in each new subroutine familiar. It is recognized that this is a “living” document and must be updated as languages, compilers, and computer hardware and software evolve.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

dfnWorks, Version 1.0

DFNWorks is a suite of software for generating and solving flow and transport physics on a Discrete Fracture Network (DFN). The suite is composed of three components: DFNGen: Stochastic fracture generation, mesh generation, model setup; DFNFlow: Flow solution using PFLOTRAN or FEHM control volume formulation solver; DFNTrans: Particle tracking transport; DFNGen Algorithm Description: This is a workflow that uses Mathematica software, Python scripts written by the authors and the LaGriT software to generate; DFNFlow; The solution of flow in porous media is accomplished by coupling DFNGen output with the existing software packages FEHM and PFLOTRAN. The DFNWorks workflow involves modules and scripts that translate DFNGen output to formats compatible with FEHM and PFLOTRAN input. FEHM LA-CC-2012-083 PFLOTRAN LA-CC-09-047 LaGriT LA-CC-07-38 DFNTrans Stand alone particle tracking algorithm that takes FEHM/PFLOTRAN flow solution as output and computes velocity field and advects particles.

Makedonska, Nataliia↗

dfnWorks, Version 2.0

DFNWorks is a suite of software for generating and solving flow and transport physics on a Discrete Fracture Network (DFN). The suite is composed of three components: DFNGen: Stochastic fracture generation, mesh generation, model setup; DFNFlow: Flow solution using PFLOTRAN or FEHM control volume formulation solver; DFNTrans: Particle tracking transport; DFNGen Algorithm Description: This is a workflow that uses C++ software version for fracture generation, Python scripts written by the authors and the LaGriT software to generate computational mesh. DFNFlow The solution of flow in porous media is accomplished by coupling DFNGen output with the existing software packages FEHM and PFLOTRAN. The DFNWorks workflow involves modules and scripts that translate DFNGen output to formats compatible with FEHM and PFLOTRAN input. FEHM LA-CC-2012-083 PFLOTRAN LA-CC-09-047 LaGriT LA-CC-07-38 DFNTrans Stand-alone particle tracking algorithm that takes FEHM/PFLOTRAN flow solution as output and computes velocity field and advects particles.

Makedonska, Nataliia↗

Snippet Open-Source Specification. Use and application

Snippet is a collaborative software code auditing tool developed at Sandia National Laboratories (Sandia) in conjunction with several sponsoring government agencies to enable software analysts, individually or in groups, to non-destructively audit large codebases, share files and comments from those audits, and develop Snippet plugins for use with other text editing software applications. This specification defines the requirements and the reasoning behind the requirements for tools developed to be compatible with the technology and purpose of Snippet. A condensation of the requirements is given in the companion document, "Snippet Open-Source Specification Synopsis" also generated by Sandia National Laboratories. Snippet's approach to browsing through codebases is similar to a web browser navigating the internet.

97 MATHEMATICS AND COMPUTING↗

dfnWorks, Version 1.0

DFNWorks is a suite of software for generating and solving flow and transport physics on a Discrete Fracture Network (DFN). The suite is composed of three components: DFNGen: Stochastic fracture generation, mesh generation, model setup; DFNFlow: Flow solution using PFLOTRAN or FEHM control volume formulation solver; DFNTrans: Particle tracking transport; DFNGen Algorithm Description: This is a workflow that uses Mathematica software, Python scripts written by the authors and the LaGriT software to generate; DFNFlow; The solution of flow in porous media is accomplished by coupling DFNGen output with the existing software packages FEHM and PFLOTRAN. The DFNWorks workflow involves modules and scripts that translate DFNGen output to formats compatible with FEHM and PFLOTRAN input. FEHM LA-CC-2012-083 PFLOTRAN LA-CC-09-047 LaGriT LA-CC-07-38 DFNTrans Stand alone particle tracking algorithm that takes FEHM/PFLOTRAN flow solution as output and computes velocity field and advects particles.

Makedonska, Nataliia↗