At least 163 records · Page 9

Inter-Comparison of S-NPP VIIRS and Aqua MODIS Thermal Emissive Bands Using Hyperspectral Infrared Sounder Measurements as a Transfer Reference

This paper compares the calibration consistency of the spectrally-matched thermal emissive bands (TEB) between the Suomi National Polar-orbiting Partnership (S-NPP) Visible Infrared Imaging Radiometer Suite (VIIRS) and the Aqua Moderate Resolution Imaging Spectroradiometer (MODIS), using observations from their simultaneous nadir overpasses (SNO). Nearly-simultaneous hyperspectral measurements from the Aqua Atmospheric Infrared Sounder(AIRS) and the S-NPP Cross-track Infrared Sounder (CrIS) are used to account for existing spectral response differences between MODIS and VIIRS TEB. The comparison uses VIIRS Sensor Data Records (SDR) in MODIS five-minute granule format provided by the NASA Land Product and Evaluation and Test Element (PEATE) and Aqua MODIS Collection 6 Level 1 B (L1B) products. Each AIRS footprint of 13.5 km (or CrIS field of view of 14 km) is co-located with multiple MODIS (or VIIRS) pixels. The corresponding AIRS- and CrIS-simulated MODIS and VIIRS radiances are derived by convolutions based on sensor-dependent relative spectral response (RSR) functions. The VIIRS and MODIS TEB calibration consistency is evaluated and the two sensors agreed within 0.2 K in brightness temperature.Additional factors affecting the comparison such as geolocation and atmospheric water vapor content are also discussed in this paper.

Li, Yonghong↗

Gallium arsenide solar cell radiation damage study

A thorough analysis has been made of electron- and proton- damaged GaAs solar cells suitable for use in space. It is found that, although some electrical parametric data and spectral response data are quite similar, the type of damage due to the two types of radiation is different. An I-V analysis model shows that electrons damage the bulk of the cell and its currents relatively more, while protons damage the junction of the cell and its voltages more. It is suggested that multiple defects due to protons in a strong field region such as a p/n junction cause the greater degradation in cell voltage, whereas the individual point defects in the quasi-neutral minority-carrier-diffusion regions due to electrons cause the greater degradation in cell current and spectral response.

Maurer, R. H.↗

Spacelab qualified infrared imager for microgravity science applications

The Lewis Research Center is developing, under contract, a Spacelab (manned module in the Space Shuttle payload bay) qualified infrared imager for noncontact surface temperature measurement in the Surface Tension Driven Convection Experiment, a microgravity fluid physics experiment. A versatile design philosophy was used in order to provide other experiments with essentially an off the shelf Shuttle qualified instrument, eliminating the duplication of the rigorous development and flight qualification processes. An Inframetrics Model 600 Scanning Infrared Radiometer is being modified to satisfy both experimental and flight requirements, while maintaining the basic performance parameters of the commercial instrument. The modifications include an efficient, low power closed cycle cryogenic cooler to cool the detector, a ruggedized scanner mechanism, 8 bit A/D conversion, Mil-STD components (where possible), size and weight optimization, and the addition of a microprocessor to perform automatic gain control. Features such as detector spectral response, the addition of spectral filters, and target temperature ranges could easily be changed to make this instrument useful as both a qualitative and quantitative diagnostic tool for Spacelab microgravity experiments, in combustion and fluid physics.

Pline, Alexander D.↗

Comparison of Lidar Methods for Remote Measurement of Air Pollutants

This paper presents quantitative comparisons of several single-ended lidar techniques for the remote measurement of gaseous pollutants. These techniques are divided into two groups. The first group is based on the measurement of energy scattered directly by the gas of interest. The gaseous scattering processes considered are ordinary fluorescence, resonance fluorescence (also called resonance scattering), Raman scattering, and resonant (or nearly resonant) Raman scattering. The second group is based on the measurement of a characteristic differential absorption produced by the gas of interest at two discrete wavelengths, using energy scattered back toward the receiver by a remote reflector other than the gas of interest. The remote reflector may be intermixed with the gas of interest, as is the case with aerosols and atmospheric gases (principally nitrogen), or they may be fixed reflectors such as terrestrial objects or retroflectors. The detectability of a given material will depend on the magnitude and characteristics of the optical interaction with that material. The main characteristics of interest are the cross section, the response time, and the spectral response of the material relative to both the transmit and receive functions of the lidar. These characteristics and their implications for remote sensing will be reviewed for the four direct scatter processes and for the differential absorption technique. The characteristic behavior of the direct backscatter technique is different from the differential absorption technique with respect to sensitivity, concentration of material, and the effect of range. For these reasons, the direct backscatter processes cannot be compared directly to the differential absorption technique. The two techniques can be compared for specific material and system configurations, however. This paper describes specific lidar system configurations and gives the calculated performance level for these systems in both the direct backscatter and differential absorption modes for a wide variety of pollutant monitoring situations. The results of this comparison of techniques indicate that the differential- absorption lidar technique can provide adequate range and sensitivity for a wide variety of pollution monitoring applications involving a number of interesting pollutant materials. No other single technique appears to provide these capabilities for such a wide range of materials.

Wright, M. L.↗

A Consistent AVHRR Visible Calibration Record Based on Multiple Methods Applicable for the NOAA Degrading Orbits: Validation - Part 2

Consistent cross-sensor Advanced Very High Resolution Radiometer (AVHRR) calibration coefficients are determined using desert, polar ice, and deep convective cloud (DCC) invariant Earth targets. The greatest AVHRR calibration challenge is the slow orbit degradation of the host satellite, which precesses toward a terminator orbit. This issue is solved by characterizing the invariant targets with NOAA-16 AVHRR observed radiances that have been referenced to the Aqua Moderate Resolution Imaging Spectrometer (MODIS) calibration using simultaneous nadir overpass (SNO) observations. Another benefit of the NOAA-16 invariant target-modeled reflectance method is that, because of the similarities among the AVHRR spectral response functions, a smaller spectral band adjustment factor is required than when establishing calibrations relative to a non-AVHRR reference instrument. The sensor- and band-specific calibration uncertainties, with respect to the calibration reference, are, on average, 2 percent and 3 percent for channels 1 and 2, respectively. The uncertainties are smaller for sensors that are in afternoon orbits, have longer records, and spend less time in terminator conditions. The multiple invariant targets referenced to Aqua MODIS (MITRAM) AVHRR calibration coefficients are evaluated for individual target consistency, compared against Aqua MODIS/AVHRR SNOs, and selected published calibration gains. The MITRAM and SNO relative calibration biases mostly agree to within 1 percent for channels 1 and 2, respectively. The individual invariant target and MITRAM sensor relative calibration biases are mostly consistent to within 1 percent and 2 percent for channels 1 and 2, respectively. The differences between the MITRAM and other published calibrations are mostly attributed to the reference instrument calibration differences.

Doelling, David R.↗

Spectroradiometric calibration of the Thematic Mapper and Multispectral Scanner system

The newly built Caste spectropolarimeters gave satisfactory performance during tests in the solar radiometer and helicopter modes. A bandwidth normalization technique based on analysis of the moments of the spectral responsivity curves was used to analyze the spectral bands of the MSS and TM subsystems of LANDSAT 4 and 5 satellites. Results include the effective wavelength, the bandpass, the wavelength limits, and the normalized responsivity for each spectral channel. Temperature coefficients for TM PF channel 6 were also derived. The moments normalization method used yields sensor parameters whose derivation is independent of source characteristics (i.e., incident solar spectral irradiance, atmospheric transmittance, or ground reflectance). The errors expected using these parameters are lower than those expected using other normalization methods.

Palmer, J. M.↗

JPSS-2 VIIRS Version 1 spectral characterization and performance assessment

The JPSS-2 VIIRS instrument is set to be the third VIIRS instrument when it launches in 2022 following S-NPP and NOAA-20 VIIRS which launched in October 2011and November 2017, respectively. To date JPSS-2 VIIRS has undergone extensive pre-launch testing at the instrument system level to determine the radiometric, spatial, and spectral performance. Spectral testing was conducted by the instrument vendor, Raytheon Corporation, at their test facility in mid-to-late 2017 with a test configuration that utilized a double monochrometer with illumination provided by tungsten lamp and ceramic glow bar to cover the full spectral range. The purpose of these measurements was to measure the relative spectral response curve and assess the spectral characteristics necessary to determine compliance with the sensor design requirements. In addition to Raytheon team, the spectral measurements were analyzed by an independent government team with members from NASA, the University of Wisconsin, and Aerospace Corporation. Two RSR curves were released by the government team from this data set: a version 0 release which was the verified RSR as calculated by Raytheon, and version 1 which was the RSR assessment from the government team. The results discussed here are those of the government team (version 1) including the independent assessment of sensor compliance and a comparison of the JPSS-2 VIIRS spectral characteristics with the two previous VIIRS instruments. The version 1 RSR was publicly released to the science community in the fall of 2018, and remains available for their use.

VIIRS↗

An evaluation of random analysis methods for the determination of panel damping

An analysis is made of steady-state and non-steady-state methods for the measurement of panel damping. Particular emphasis is placed on the use of random process techniques in conjunction with digital data reduction methods. The steady-state methods considered use the response power spectral density, response autocorrelation, excitation-response crosspower spectral density, or single-sided Fourier transform (SSFT) of the response autocorrelation function. Non-steady-state methods are associated mainly with the use of rapid frequency sweep excitation. Problems associated with the practical application of each method are evaluated with specific reference to the case of a panel exposed to a turbulent airflow, and two methods, the power spectral density and the single-sided Fourier transform methods, are selected as being the most suitable. These two methods are demonstrated experimentally, and it is shown that the power spectral density method is satisfactory under most conditions, provided that appropriate corrections are applied to account for filter bandwidth and background noise errors. Thus, the response power spectral density method is recommended for the measurement of the damping of panels exposed to a moving airflow.

Bhat, W. V.↗

Wheat signature modeling and analysis for improved training statistics

The author has identified the following significant results. The spectral, spatial, and temporal characteristics of wheat and other signatures in LANDSAT multispectral scanner data were examined through empirical analysis and simulation. Irrigation patterns varied widely within Kansas; 88 percent of wheat acreage in Finney was irrigated and 24 percent in Morton, as opposed to less than 3 percent for western 2/3's of the State. The irrigation practice was definitely correlated with the observed spectral response; wheat variety differences produced observable spectral differences due to leaf coloration and different dates of maturation. Between-field differences were generally greater than within-field differences, and boundary pixels produced spectral features distinct from those within field centers. Multiclass boundary pixels contributed much of the observed bias in proportion estimates. The variability between signatures obtained by different draws of training data decreased as the sample size became larger; also, the resulting signatures became more robust and the particular decision threshold value became less important.

Nalepka, R. F.↗

A multispectral analysis of algal bloom in the Gulf of Mexico

Skylab multispectral scanner data acquired on January 21, 1974, were used to study the spectral characteristics of an algal bloom in the Gulf of Mexico west of Fort Myers, Florida. Radiance profiles of the water and algae were prepared with data from ten bands of the S192 scanner covering the spectral range from .42 to 2.35 micrometers. The high spectral response in the near-infrared spectral bands implies a possible classification and discrimination parameter for detection of blooms of phytoplankton concentrations such as the so-called red tides of Florida.

Johnson, W. R.↗

Results of the 1978 NASA/JPL balloon flight solar cell calibration program

The 1978 scheduled solar cell calibration balloon flight was successfully completed. Thirty six modules were carried to an altitude of above 36 kilometers. Recovery of telemetry and flight packages was without incident. These calibrated standard cells are used as reference standards in simulator testing of cells and arrays with similar spectral response characteristics. The factors affecting the spectral transmission of the atmosphere at various altitudes are summarized.

Seaman, C. H.↗

Design Through Integration of On-Board Calibration Device with Imaging Spectroscopy Instruments

The main purpose of the Airborne Visible and Infrared Imaging Spectroscopy (AVIRIS) project is to "identify, measure, and monitor constituents of the Earth's surface and atmosphere based on molecular absorption and particle scattering signatures." The project designs, builds, and tests various imaging spectroscopy instruments that use On-Board Calibration devices (OBC) to check the accuracy of the data collected by the spectrometers. The imaging instrument records the spectral signatures of light collected during flight. To verify the data is correct, the OBC shines light which is collected by the imaging spectrometer and compared against previous calibration data to track spectral response changes in the instrument. The spectral data has the calibration applied to it based on the readings from the OBC data in order to ensure accuracy.

imaging spectroscopy↗

Evaluation of the Surface Reflectance Long-Term Data Record from AVHRR over Multiple Land Surface Types

In this work, we evaluate the performance of the AVHRR surface reflectance LTDR V4 using Landsat-5 Thematic Mapper (TM5) Collection-1 surface reflectance data over 440 globally distributed sites, which give a representative set of land surface types and climate conditions. Surface reflectance anisotropy effects were normalized using the VJB method, and spectral response differences were accounted for with spectral band adjustment factors (SBAFs) computed as a function of the Normalized Difference Vegetation Index (NDVI) from a set of over 100,000 hyperspectral spectra from Hyperion. The performance of the AVHRR record is reported in terms of the accuracy, precision, and uncertainty, as compared to the specifications of the reference product. Results show that the AVHRR record performance is close to the 0.071ρ+0.0071 specification defined in the original TM5 product evaluation.

LTDR↗

Landsat 9 Thermal Infrared Sensor 2 Pre-Launch Characterization: Initial Imaging & Spectral Performance Results

The Thermal Infrared Sensor-2 (TIRS-2) scheduled to launch in December 2020 aboard Landsat 9 will continue Landsat's four decade-long legacy of providing moderate resolution thermal imagery from low earth orbit (at 705 km) for environmental applications. Like the Thermal Infrared Sensor aboard Landsat 8, it is a pushbroom sensor with a cross-track field of view of 15 and provides two spectral channels at 10.8 and 12 um. To ensure radiometric, spatial, and spectral performance, a comprehensive pre-launch testing program is being conducted at NASA Goddard Space Flight Center at the component, subsystem, and instrument level. This effort will focus on the results from the subsystem level testing to assess TIRS-2 imaging performance including focus, spatial performance, and stray light rejection. It is also used to provide a preliminary assessment of spectral performance. The TIRS-2 subsystem is placed in a thermal vacuum chamber with the calibration ground support equipment, which provides a flexible blackbody illumination source and optics to assess imaging performance. Spectral performance is tested using a spectral response test setup with its own illumination source outside the chamber that propagates through the calibration ground support equipment in an optical configuration designed for this purpose. The results show that TIRS-2 performance is expected to meet all of its performance requirements with few waivers and deviations.

scatter↗

In-flight validation and calibration of the spectral and radiometric characteristics of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)

Through an in-flight calibration experiment at Rogers Dry Lake, California on September 20, 1989, the radiometric and spectral properties of AVIRIS were determined. In-flight spectral channel positions and the spectral response function in 10 regions of the AVIRIS spectral range, taking in all four spectrometers, are shown to agree closely with the corresponding parameters measured in the laboratory. The intraflight stability for the Rogers Dry Lake calibration site is better than 2 percent with the exception of the strong atmospheric water absorptions where the measured radiance is close to zero. This experiment has provided both direct generation of an in-flight spectral and radiometric calibration and validation of the laboratory calibration at the reported level accuracy.

Green, Robert O.↗

Predicting LANDSAT MSS endmember signatures from corresponding higher resolution TM fraction images

The approach to predicting Landsat Multispectral Scanner System (MSS) endmember signatures from fraction images derived from high resolution Landsat Thematic Mapper (TM) data is presented. The purpose, conducted in the Mogi-Guacu study site located in Sao Paulo State, Brazil, was to determine if information derived from a mixture model applied to higher resolution TM data could serve as ground truth for the lower resolution MSS sensor. The Constrained Least Squares (CLS) method was used to generate vegetation, soil, and shade fraction images from the TM data. The resulting images were then used to estimate the endmember spectral response for MSS data by regressing each MSS spectral channel against the corresponding proportion values estimated for the same resolution cells from the TM mixture model. The evaluation of the predicted signatures was performed by comparing the corresponding fraction images derived from both the MSS and TM data acquired on 14 Sep. 1986. The techniques serves as a potential tool for integrating information in global studies where remote sensors with different spectral and spatial resolutions were used.

Shimabukuro, Yosio E.↗