Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectrometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Compositional analysis of organosolv poplar lignin by using high-performance liquid chromatography/high-resolution multi-stage tandem mass spectrometry

Organosolv treatment is an efficient and environmentally friendly process to degrade lignin into small compounds. The capability of characterizing the individual compounds in the complex mixtures formed upon organosolv treatment is essential for the optimization of the further lignin conversion processes and for the rational genetic engineering of plants used to produce lignin in order to improve lignin properties. In this study, an organosolv poplar lignin sample was initially analyzed by high-resolution mass spectrometry coupled with negative-ion mode electrospray ionization ((-)ESI HRMS). Lignin monomers and dimers were found to constitute the majority of the compounds in the organosolv lignin sample. Larger lignin oligomers, such as trimers and tetramers, and some not lignin-related compounds, were also detected. A high-performance liquid chromatograph/linear quadrupole ion trap/orbitrap mass spectrometer capable of multi-stage high-resolution tandem mass spectrometry experiments (HRMS n ), equipped with an (-)ESI source (HPLC/(-)ESI HRMS n ), was employed to separate the unknown compounds in the organosolv mixture and to obtain structural information for the deprotonated compounds via collision-activated dissociation (CAD) HRMS n experiments. To improve the understanding of the CAD behavior of deprotonated lignin-related compounds, 16 deprotonated model compounds with different functionalities and linkage types were examined. This approach enabled the assignment of likely structures for several lignin monomers, dimers, trimers, and tetramers, and some not lignin-related compounds, most likely fatty acids. Based on the proposed structures, compounds in the organosolv lignin sample contain β-O-4, 5–5, β-5, and possibly also 4-O-5 linkages. Most compounds contain G- and S-monomeric units although a small amount of H-units were also detected.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A combinatorial droplet microfluidic device integrated with mass spectrometry for enzyme screening

Mass spectrometry (MS) enables detection of different chemical species with a very high specificity; however, it can be limited by its throughput. Integrating MS with microfluidics has a tremendous potential to improve throughput and accelerate biochemical research. In this work, we introduce Drop-NIMS, a combination of a passive droplet loading microfluidic device and a matrix-free MS laser desorption ionization technique called nanostructure-initiator mass spectrometry (NIMS). This platform combines different droplets at random to generate a combinatorial library of enzymatic reactions that are deposited directly on the NIMS surface without requiring additional sample handling. The enzyme reaction products are then detected with MS. Drop-NIMS was used to rapidly screen enzymatic reactions containing low (on the order of nL) volumes of glycoside reactants and glycoside hydrolase enzymes per reaction. MS “barcodes” (small compounds with unique masses) were added to the droplets to identify different combinations of substrates and enzymes created by the device. We assigned xylanase activities to several putative glycoside hydrolases, making them relevant to food and biofuel industrial applications. Overall, Drop-NIMS is simple to fabricate, assemble, and operate and it has potential to be used with many other small molecule metabolites.

47 OTHER INSTRUMENTATION↗

Biomarkers, Proteoforms, and Mass Spectrometry–Based Assays for Diabetes Clinical Research

Abstract The prevalence of diabetes, particularly type 2 diabetes, has reached epidemic proportions globally. The number of patients with type 1 diabetes (T1D) is also increasing rapidly. Despite advancements in understanding the pathogenesis of diabetes, the lack of circulating pancreatic biomarkers and reliable clinical-grade assays remains a major gap in diabetes research, often hindering the ability to adequately assess disease progression and therapeutic responses. This mini-review discusses emerging pancreatic biomarkers, with an emphasis on T1D, the limitations of current immunoassays, and the expanding role of mass spectrometry–based assays. Highlights include the recent work within the NIDDK-funded “Targeted Mass Spectrometry Assays for Diabetes and Obesity Research (TaMADOR)” consortium, which aims to develop robust, quantitative, and transferable assays for translational research. The review also emphasizes the importance of proteoform-specific assays for monitoring pancreatic function, including prohormone processing during disease progression or in responses to therapy.

Endocrinology & Metabolism↗

Development of Direct Injection/Ionization Mass Spectrometry Methods for Whole Molecule Characterization

The objective of this work is to adapt ambient ionization mass spectrometry (AMS) techniques for the rapid analysis of intact uranium complexes, stable strontium, cerium, and explosive compounds. The methods used were “soft ionization” techniques, which facilitate the detection of whole molecule complexes. The soft ionization mass spectrometry (MS) techniques that were investigated include paper spray ionization (PSI), matrix-assisted ionization (MAI), electrospray ionization (ESI) and direct analysis in real time (DART). For the first time, PSI-MS methods were successfully developed for whole molecule uranium-containing analytes (uranyl acetate, uranyl nitrate, and uranyl-tributylphosphate complexes). This was also the first demonstration of uranium complex detection and characterization and one of the few examples of inorganic analysis using MAI techniques. Proof of concept experiments also putatively identified matrix-derived ions and ion complexes that have not previously been described in the literature. Additionally, PSI-MS on cotton swipe samples doped with a multi-element standard containing μg levels of U, Bi, Pb, Cd, Fe, and Zn were directly analyzed without purification, representing a major improvement over existing methods. Both PSI and MAI methods demonstrated limits of detection (LODs) in the 10 - 100’s ng for various uranyl species within a range of 10’s ppm - 100’s ppb, dependent on analytical method and analyte species. AMS methods were also developed for other inorganics, including Ce and Sr, and organic explosive residues to address specific challenges in environmental monitoring and forensics. Further refinement and qualification of the AMS techniques developed within this effort would lead to significant cost reduction and timeliness by facilitating the triage and queueing of samples for subsequent more sensitive and time-consuming analyses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

National User Resource for Biological Accelerator Mass Spectrometry (Annual Report)

The National User Resource for Biological Accelerator Mass Spectrometry (User Resource) will provide isotopic analysis (primarily radiocarbon or 14C) by accelerator mass spectrometry (AMS) for NIH- funded researchers across the United States and will be the only User Resource of its type in the United States. The User Resource will provide measurement capability and expertise to a research community that requires highly sensitive, quantitative isotope analyses. Since commissioning a new accelerator mass spectrometer in June 2014, we have measured over 4000 samples a year for collaborators and service users. The User Resource will enable us to continue to meet these research needs, as well as provide for new users whose research programs would benefit from AMS as a measurement tool.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of imaging and mass spectrometry-based capabilities to describe microbiome interactions (Q4 Performance Metric Report, 2021)

The LLNL “Microbes Persist” Soil Microbiome Scientific Focus Area (SFA) seeks to determine how microbial soil ecophysiology, population dynamics, and microbe-mineral-organic matter interactions regulate the persistence of microbial residues and formation of soil carbon (C). In much of our research, we use imaging, mass spectrometry, and related methods to study plantmicrobe-mineral interactions, viral and microbial particles from soil, and the signatures plant and microbial necromass contribute as part of soil organic matter (SOM). Our project’s signature techniques include NanoSIMS-enabled approaches (to understand cell-cell and OM-mineral interactions at the single cell and even viral particle scale), radiocarbon (14C) analyses (to determine both the age and turnover time of soil organic matter), and a suite of soil chemical characterization techniques we describe below, and collectively refer to as ‘Multi- dimensional SOM-mineral characterization’ (SEM, TEM, STXM, NEXAFS, NMR, FTICR-MS, LC-MS). In this report, we focus on how imaging, NMR, beamline and mass spectrometry approaches can deepen our understanding of soil microbiomes and their engagement with the soil matrix.

54 ENVIRONMENTAL SCIENCES↗

National User Resource for Biological Accelerator Mass Spectrometry Annual Report

The National User Resource for Biological Accelerator Mass Spectrometry (User Resource) will provide isotopic analysis (primarily radiocarbon or 14C) by accelerator mass spectrometry (AMS) for NIH-funded researchers across the United States and will be the only User Resource of its type in the United States. The User Resource will provide measurement capability and expertise to a research community that requires highly sensitive, quantitative isotope analyses. Since commissioning a new accelerator mass spectrometer in June 2014, we have measured over 4000 samples a year for collaborators and service users. The User Resource will enable us to continue to meet these research needs, as well as provide for new users whose research programs would benefit from AMS as a measurement tool.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

High resolution mobility spectrometry in a co-axial platform

Ion mobility spectrometry is an analytical technique that separate ions in the gas phase based on their interaction with a neutral buffer gas. Ion mobility spectrometry performs separations quickly (typically less than a second) and the ion mobilities are very reproducible across different laboratories. This project aimed at evaluating the performance of a new ion mobility device. The new device relies on conducting ion mobility separation in a curved geometry. The project explored the operation landscape of the device using ion trajectory simulations then fabricated and experimentally demonstrated the device's performance. Ion trajectory simulations on a set of tetraalkylammonium and phosphazene ions indicate that ions traveling a curved path length undergo mobility separation that is similar to a straight path. The ion mobility resolution of the curved device was found to be similar to that of a straight path of a similar length. The experimental validation of the new device confirmed the device's ability to separate ions according to their mobilities. Sets of mixtures (tetraalkylammonium ions, phosphazene ions, and peptide ions) were evaluated for separation and transmission.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Applications of Alternate Actinide Calibration on Inductively Coupled Plasma Mass Spectrometry (ICPMS) Analysis of H-Canyon Highly Enriched Uranium Legacy Material at the Savannah River Site (SRS)

The Savannah River National Laboratory (SRNL) uses Inductively Coupled Plasma Mass Spectrometry (ICPMS) to support numerous programs at the Savannah River Site (SRS). As part of an objective to prepare high assay low enriched uranium (HALEU), the SRS H-Canyon needed analysis of legacy uranyl nitrate that is stored at its Outside Facilities (HOF). With the application of a standard practice for alternate actinide calibration on ICP-MS, SRNL has successfully demonstrated its capability to characterize the uranium/actinide composition of the HOF tanks that are intended for consolidation prior to preparation of the HALEU. A comparison of the uranium analytical results between recently upgraded SRNL ICP-MS and Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) instrumentation shows the alternate actinide calibration is a valid complementary method when used in conjunction with other analytical techniques (Davies-Gray Potentiometric Titration). The methods, instrumentation, and ongoing developments on ICP-MS at SRNL will be discussed.

Jones, Mark A.↗

Algorithms and file structures to enhance software workflows for ion mobility mass spectrometry (IM-MS)

Support customizations of algorithms and raw data file structures to enhance software workflows for liquid chromatography (LC), mass spectrometry (MS) and ion mobility mass spectrometry (IM-MS)-based metabolite characterization. Evaluate and improve the integration of ion mobility to existing MS analysis methods of the Mass Profiler Professional workflow (Mass Profiler, ID Browser and Mass Profiler Professional).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using Separation-Enhanced Isotope Ratio Mass Spectrometry to Enable Increased Renewable Carbon Content in Transportation Fuels (CRADA 525)

Stable isotope ratio measurements of carbon atoms using isotope ratio mass spectrometry (IRMS) can be an effective tool for quantifying biogenic carbon in co-processed fuels, with results approaching the precision and accuracy of accelerator mass spectrometry (AMS). The lower cost of an IRMS may enable deployment to refineries, improving access and analysis turnaround times (≤2 hours), and, by extension, provide data that can allow process optimization to maximize renewable carbon in desired refinery products. This project explored the integration of chemical separation with IRMS analyses to enable highly detailed tracking of biogenic carbon into fuel product streams separated by boiling point range, chemical class, or specific compound. Forty-nine fuels and fuel components of fossil and biogenic origin, spanning gasoline and diesel boiling point ranges, were received from three refiners and were analyzed for their δ 13 C values via IRMS. Results spanned a 13 C range from ca. 10‰ to 44‰ and reflect materials derived from sustainable sources (e.g., C4 or C3 plants, animal-based pathways, syngas) or from fossil-derived fuels. Common ranges are approximately 18‰ to 9‰ and approximately 30‰ to 20‰ for C4 and C3 plants, respectively, and approximately 34‰ to 24‰ and approximately 70‰ to 33‰ for petroleum-derived fuels and methane, respectively. Fuel-like standards were developed and tested using direct-injection elemental analyzer (EA) IRMS for liquid fuels. This method was compared with the published methods, yielding statistically similar results. Four blend curve sets were produced ranging from 0% to 100% of a fuel containing biogenic carbon, focusing on 0% to 10% biogenic carbon. Linear fits were the most applicable for two of the four blend curve sets; however, two sets were found to exhibit slightly quadratic behavior, which was more pronounced in low biogenic blend samples, necessitating second-order fits. The origin of the slight quadratic behavior remains unclear; however, the discussion points to possible interpretations. CanmetENERGY thoroughly characterized a majority of the samples using one- and two-dimensional gas chromatography (GC and GC×GC, respectively) and other analyses. Selected samples were subjected to solid phase extraction (SPE) for saturate, olefin, aromatic, and polar (SOAP) analysis, and the resulting solvent-diluted fractions containing saturates and aromatics were returned to Pacific Northwest National Laboratory (PNNL), where the solvent was removed via evaporation or physical separation using GC techniques. Characterization and separations provided an understanding of saturate and aromatic content, as well as boiling point ranges for each sample and sample fraction. Samples resulting from SPE were examined using EA-IRMS and gas chromatography combustion IRMS (GC-C-IRMS) analyses. Both approaches suggest that the range in values between end-members can be increased by selecting the paraffinic or aromatic fraction of the end-member or by selecting among individual compounds resulting from GC separation of the paraffinic fractions. Considerable work remains to put these approaches into practice and statistically validate the benefit for using a fraction or individual compound over bulk analysis of a sample. However, initial results suggest that separations provide advantages for samples having blend ratios of less than 10% biogenic blendstocks. 13 C results showed statistically similar biofuel blend results to those obtained at PNNL, although additional work is needed to obtain better reproducibility. Select samples were sent to Los Alamos National Laboratory (LANL) for IRMS measurements and Beta Analytics for AMS measurements. This work suggests that IRMS and AMS yield closely comparable results and in some circumstances, IRMS could serve as a surrogate for AMS. While additional work is needed to better resolve statistical advantages for separations and better show the comparable nature of IRMS and AMS in both the biogenic carbon analysis of bulk chemical classes, initial results from this study suggest that these should be pursued in order to proliferate this approach for quantifying biogenic carbon in transportation fuels to the refinery level, thereby potentially enabling process optimization in co-processing scenarios.

09 BIOMASS FUELS↗

DEIMoS: An Open-Source Tool for Processing High-Dimensional Mass Spectrometry Data

We present DEIMoS: Data Extraction for Integrated Multidimensional Spectrometry, a Python application programming interface and command-line tool for high-dimensional mass spectrometry data analysis workflows, offering ease of development and access to efficient algorithmic implementations. Functionality includes feature detection, feature alignment, collision cross section calibration, isotope detection, and MS/MS spectral deconvolution, with the output comprising detected features aligned across study samples and characterized by mass, CCS, tandem mass spectra, and isotopic signature. Notably, DEIMoS operates on N-dimensional data, largely agnostic to acquisition instrumentation: algorithm implementations utilize all dimensions simultaneously to (i) offer greater separation between features, improving detection sensitivity, (ii) increase alignment/feature matching confidence among datasets, and (iii) mitigate convolution artifacts in tandem mass spectra. We demonstrate DEIMoS with LC-IMS-MS/MS data, demonstrating the advantages of a multidimensional approach in each data processing step.

Colby, Sean M↗

Studying Interfacial Dark Reactions of Glyoxal and Hydrogen Peroxide Using Vacuum Ultraviolet Single Photon Ionization Mass Spectrometry

Aqueous secondary organic aerosol (aqSOA) formation from volatile and semivolatile organic compounds at the air–liquid interface is considered as an important source of fine particles in the atmosphere. However, due to the lack of in situ detecting techniques, the detailed interfacial reaction mechanism and dynamics still remain uncertain. In this study, synchrotron-based vacuum ultraviolet single-photon ionization mass spectrometry (VUV SPI-MS) was coupled with the System for Analysis at the Liquid Vacuum Interface (SALVI) to investigate glyoxal dark oxidation products at the aqueous surface. Mass spectral analysis and determination of appearance energies (AEs) suggest that the main products of glyoxal dark interfacial aging are carboxylic acid related oligomers. Furthermore, the VUV SPI-MS results were compared and validated against those of in situ liquid time-of-flight secondary ion mass spectrometry (ToF-SIMS). The reaction mechanisms of the dark glyoxal interfacial oxidation, obtained using two different approaches, indicate that differences in ionization and instrument operation principles could contribute to their abilities to detect different oligomers. Therefore, the mechanistic differences revealed between the VUV SPI-MS and ToF-SIMS indicate that more in situ and real-time techniques are needed to investigate the contribution of the air–liquid interfacial reactions leading to aqSOA formation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reviews and syntheses: Opportunities for robust use of peak intensities from high-resolution mass spectrometry in organic matter studies

Abstract. Earth's biogeochemical cycles are intimately tied to the biotic and abiotic processing of organic matter (OM). Spatial and temporal variations in OM chemistry are often studied using direct infusion, high-resolution Fourier transform mass spectrometry (FTMS). An increasingly common approach is to use ecological metrics (e.g., within-sample diversity) to summarize high-dimensional FTMS data, notably Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS). However, problems can arise when FTMS peak-intensity data are used in a way that is analogous to abundances in ecological analyses (e.g., species abundance distributions). Using peak-intensity data in this way requires the assumption that intensities act as direct proxies for concentrations. Here, we show that comparisons of the same peak across samples (within-peak) may carry information regarding variations in relative concentration, but comparing different peaks (between-peak) within or between samples does not. We further developed a simulation model to study the quantitative implications of using peak intensities to compute ecological metrics (e.g., intensity-weighted mean properties and diversity) that rely on information about both within-peak and between-peak shifts in relative abundance. We found that, despite analytical limitations in linking concentration to intensity, ecological metrics often perform well in terms of providing robust qualitative inferences and sometimes quantitatively accurate estimates of diversity and mean molecular characteristics. We conclude with recommendations for the robust use of peak intensities for natural organic matter studies. A primary recommendation is the use and extension of the simulation model to provide objective guidance on the degree to which conceptual and quantitative inferences can be made for a given analysis of a given dataset. Broad use of this approach can help ensure rigorous scientific outcomes from the use of FTMS peak intensities in environmental applications.

54 ENVIRONMENTAL SCIENCES↗

Zero voltage mass spectrometry probes and systems

The invention generally relates to zero volt mass spectrometry probes and systems. In certain embodiments, the invention provides a system including a mass spectrometry probe including a porous material, and a mass spectrometer (bench-top or miniature mass spectrometer). The system operates without an application of voltage to the probe. In certain embodiments, the probe is oriented such that a distal end faces an inlet of the mass spectrometer. In other embodiments, the distal end of the probe is 5 mm or less from an inlet of the mass spectrometer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimization Of In-field Alpha Spectrometry For Uranium Enrichment Determination In Uranium Hexafluoride

In response to needs identified by the International Atomic Energy Agency (IAEA) research is underway to develop In-Field Alpha Spectrometry (IFAS) as a method to allow IAEA safeguards inspectors to collect samples of uranium hexafluoride (UF6) at processing facilities to assess and verify uranium enrichment. For sample collection, the IFAS method uses Single-Use Destructive Assay (SUDA) samplers, which contain thin zeolite coatings that trap UF6 gas and convert it to the safer, more stable form uranyl fluoride (as a dihydrate, UO2F2·2H2O). For alpha spectrometry, the IFAS instrument employs a large area silicon semiconductor transducer to detect and record alpha particle energy-deposition events. Over the past year optimization work has significantly increased the diameter of useful SUDA samples (from 12.7 mm to 48 mm), improved the manufacturability and reproducibility of SUDA samples, increased the area of the IFAS alpha spectrometer sensor from 1.2 cm to 3.1 cm, and improved source positioning within the IFAS. This paper will report on this optimization work, its impacts on IFAS performance, and future plans for IFAS miniaturization, improvements, and testing.

Chichester, David↗